Christian Peest
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christian Peest has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Carsten Schinke
Institute for Solar Energy Research Hamelin (ISFH), Am Ohrberg 1, 31860 Emmerthal, Germany
2 shared publications- Jan Schmidt
Institute for Solar Energy Research Hamelin (ISFH), Emmerthal, Germany
2 shared publications Karsten Bothe
Institute for Solar Energy Research Hamelin (ISFH), Am Ohrberg 1, 31860 Emmerthal, Germany
2 shared publications- Maarten Baes
Universiteit Gent, Department of Physics and Astronomy
2 shared publications - Peter Camps
Department of Physics and Astronomy, Universiteit Gent
2 shared publications Rolf Brendel
Institute for Solar Energy Research Hamelin (ISFH), Am Ohrberg 1, 31860 Emmerthal, Germany
2 shared publications
Latest Publications
- Open Access
- 29 October 2023
- Published by Elsevier in Journal of Computational Physics: X
- Vol. 17
Monte Carlo radiative transfer peel off mechanism for spatially extended detectors
- 29 October 2023
- Published by Elsevier in Journal of Computational Physics: X
- Vol. 17
Open AccessMonte Carlo radiative transfer peel off mechanism for spatially extended detectors
- Open Access
- 16 May 2023
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 673, A112
Paradigmatic examples for testing models of optical light polarization by spheroidal dust
We present a general framework on how the polarization of radiation due to scattering, dichroic extinction, and birefringence of aligned spheroidal dust grains can be implemented and tested in 3D Monte Carlo radiative transfer (MCRT) codes. We derive a methodology for solving the radiative transfer equation governing the changes of the Stokes parameters in dust-enshrouded objects. We utilize the Müller matrix and the extinction, scattering, linear, and circular polarization cross sections of spheroidal grains as well as electrons. An established MCRT code is used, and its capabilities are extended to include the Stokes formalism. We compute changes in the polarization state of the light by scattering, dichroic extinction, and birefringence on spheroidal grains. The dependency of the optical depth and the albedo on the polarization is treated. The implementation of scattering by spheroidal grains both for random walk steps as well as for directed scattering (peel-off) are described. The observable polarization of radiation of the objects is determined through an angle binning method for photon packages that leaves the model space as well as through an inverse ray-tracing routine for the generation of images. We present paradigmatic examples for which we derive analytical solutions of the optical light polarization by spheroidal dust particles. These tests are suited for benchmark verification of MCPOLand other such codes and allow the numerical precision reached by these codes to be quantified. We demonstrate that MCPOLis in excellent agreement (within ~0.1%) of the Stokes parameters when compared to the analytical solutions.
- 16 May 2023
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 673, A112
Open AccessParadigmatic examples for testing models of optical light polarization by spheroidal dust
We present a general framework on how the polarization of radiation due to scattering, dichroic extinction, and birefringence of aligned spheroidal dust grains can be implemented and tested in 3D Monte Carlo radiative transfer (MCRT) codes. We derive a methodology for solving the radiative transfer equation governing the changes of the Stokes parameters in dust-enshrouded objects. We utilize the Müller matrix and the extinction, scattering, linear, and circular polarization cross sections of spheroidal grains as well as electrons. An established MCRT code is used, and its capabilities are extended to include the Stokes formalism. We compute changes in the polarization state of the light by scattering, dichroic extinction, and birefringence on spheroidal grains. The dependency of the optical depth and the albedo on the polarization is treated. The implementation of scattering by spheroidal grains both for random walk steps as well as for directed scattering (peel-off) are described. The observable polarization of radiation of the objects is determined through an angle binning method for photon packages that leaves the model space as well as through an inverse ray-tracing routine for the generation of images. We present paradigmatic examples for which we derive analytical solutions of the optical light polarization by spheroidal dust particles. These tests are suited for benchmark verification of MCPOLand other such codes and allow the numerical precision reached by these codes to be quantified. We demonstrate that MCPOLis in excellent agreement (within ~0.1%) of the Stokes parameters when compared to the analytical solutions.
- 23 September 2019
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 630, A61
Optical depth in polarised Monte Carlo radiative transfer
Context. The Monte Carlo method is the most widely used method to solve radiative transfer problems in astronomy, especially in a fully general 3D geometry. A crucial concept in any Monte Carlo radiative transfer code is the random generation of the next interaction location. In polarised Monte Carlo radiative transfer with aligned non-spherical grains, the nature of dichroism complicates the concept of optical depth. Aims. We investigate, in detail, the relation between optical depth and the optical properties and density of the attenuating medium in polarised Monte Carlo radiative transfer codes that take dichroic extinction into account. Methods. Based on solutions for the radiative transfer equation, we discuss the optical depth scale in polarised radiative transfer with spheroidal grains. We compare the dichroic optical depth to the extinction and total optical depth scale. Results. In a dichroic medium, the optical depth is not equal to the usual extinction optical depth, nor to the total optical depth. For representative values of the optical properties of dust grains, the dichroic optical depth can differ from the extinction or total optical depth by several tens of percent. A closed expression for the dichroic optical depth cannot be given, but it can be derived efficiently through an algorithm that is based on the analytical result corresponding to elongated grains with a uniform grain alignment. Conclusions. Optical depth is more complex in dichroic media than in systems without dichroic attenuation, and this complexity needs to be considered when generating random free path lengths in Monte Carlo radiative transfer simulations. There is no benefit in using approximations instead of the dichroic optical depth.
- 23 September 2019
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 630, A61
Optical depth in polarised Monte Carlo radiative transfer
Context. The Monte Carlo method is the most widely used method to solve radiative transfer problems in astronomy, especially in a fully general 3D geometry. A crucial concept in any Monte Carlo radiative transfer code is the random generation of the next interaction location. In polarised Monte Carlo radiative transfer with aligned non-spherical grains, the nature of dichroism complicates the concept of optical depth. Aims. We investigate, in detail, the relation between optical depth and the optical properties and density of the attenuating medium in polarised Monte Carlo radiative transfer codes that take dichroic extinction into account. Methods. Based on solutions for the radiative transfer equation, we discuss the optical depth scale in polarised radiative transfer with spheroidal grains. We compare the dichroic optical depth to the extinction and total optical depth scale. Results. In a dichroic medium, the optical depth is not equal to the usual extinction optical depth, nor to the total optical depth. For representative values of the optical properties of dust grains, the dichroic optical depth can differ from the extinction or total optical depth by several tens of percent. A closed expression for the dichroic optical depth cannot be given, but it can be derived efficiently through an algorithm that is based on the analytical result corresponding to elongated grains with a uniform grain alignment. Conclusions. Optical depth is more complex in dichroic media than in systems without dichroic attenuation, and this complexity needs to be considered when generating random free path lengths in Monte Carlo radiative transfer simulations. There is no benefit in using approximations instead of the dichroic optical depth.
- Open Access
- 10 May 2017
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 601, A92
Polarization in Monte Carlo radiative transfer and dust scattering polarization signatures of spiral galaxies
Astronomy & Astrophysics (A&A) is an international journal which publishes papers on all aspects of astronomy and astrophysics
- 10 May 2017
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 601, A92
Open AccessPolarization in Monte Carlo radiative transfer and dust scattering polarization signatures of spiral galaxies
Astronomy & Astrophysics (A&A) is an international journal which publishes papers on all aspects of astronomy and astrophysics
- 1 January 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (1) , 015105
Instrumentation-related uncertainty of reflectance and transmittance measurements with a two-channel spectrophotometer
Spectrophotometers are operated in numerous fields of science and industry for a variety of applications. In order to provide confidence for the measured data, analyzing the associated uncertainty is valuable. However, the uncertainty of the measurement results is often unknown or reduced to sample-related contributions. In this paper, we describe our approach for the systematic determination of the measurement uncertainty of the commercially available two-channel spectrophotometer Agilent Cary 5000 in accordance with the Guide to the expression of uncertainty in measurements. We focus on the instrumentation-related uncertainty contributions rather than the specific application and thus outline a general procedure which can be adapted for other instruments. Moreover, we discover a systematic signal deviation due to the inertia of the measurement amplifier and develop and apply a correction procedure. Thereby we increase the usable dynamic range of the instrument by more than one order of magnitude. We present methods for the quantification of the uncertainty contributions and combine them into an uncertainty budget for the device.
- 1 January 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (1) , 015105
Instrumentation-related uncertainty of reflectance and transmittance measurements with a two-channel spectrophotometer
Spectrophotometers are operated in numerous fields of science and industry for a variety of applications. In order to provide confidence for the measured data, analyzing the associated uncertainty is valuable. However, the uncertainty of the measurement results is often unknown or reduced to sample-related contributions. In this paper, we describe our approach for the systematic determination of the measurement uncertainty of the commercially available two-channel spectrophotometer Agilent Cary 5000 in accordance with the Guide to the expression of uncertainty in measurements. We focus on the instrumentation-related uncertainty contributions rather than the specific application and thus outline a general procedure which can be adapted for other instruments. Moreover, we discover a systematic signal deviation due to the inertia of the measurement amplifier and develop and apply a correction procedure. Thereby we increase the usable dynamic range of the instrument by more than one order of magnitude. We present methods for the quantification of the uncertainty contributions and combine them into an uncertainty budget for the device.
- Top Cited PapersOpen Access
- 1 June 2015
- Published by AIP Publishing in AIP Advances
- Vol. 5 (6) , 067168
Uncertainty analysis for the coefficient of band-to-band absorption of crystalline silicon
We analyze the uncertainty of the coefficient of band-to-band absorption of crystalline silicon. For this purpose, we determine the absorption coefficient at room temperature (295 K) in the wavelength range from 250 to 1450 nm using four different measurement methods. The data presented in this work derive from spectroscopic ellipsometry, measurements of reflectance and transmittance, spectrally resolved luminescence measurements and spectral responsivity measurements. A systematic measurement uncertainty analysis based on the Guide to the expression of uncertainty in measurement (GUM) as well as an extensive characterization of the measurement setups are carried out for all methods. We determine relative uncertainties of the absorption coefficient of 0.4% at 250 nm, 11% at 600 nm, 1.4% at 1000 nm, 12% at 1200 nm and 180% at 1450 nm. The data are consolidated by intercomparison of results obtained at different institutions and using different measurement approaches.
- 1 June 2015
- Published by AIP Publishing in AIP Advances
- Vol. 5 (6) , 067168
Top Cited PapersOpen AccessUncertainty analysis for the coefficient of band-to-band absorption of crystalline silicon
We analyze the uncertainty of the coefficient of band-to-band absorption of crystalline silicon. For this purpose, we determine the absorption coefficient at room temperature (295 K) in the wavelength range from 250 to 1450 nm using four different measurement methods. The data presented in this work derive from spectroscopic ellipsometry, measurements of reflectance and transmittance, spectrally resolved luminescence measurements and spectral responsivity measurements. A systematic measurement uncertainty analysis based on the Guide to the expression of uncertainty in measurement (GUM) as well as an extensive characterization of the measurement setups are carried out for all methods. We determine relative uncertainties of the absorption coefficient of 0.4% at 250 nm, 11% at 600 nm, 1.4% at 1000 nm, 12% at 1200 nm and 180% at 1450 nm. The data are consolidated by intercomparison of results obtained at different institutions and using different measurement approaches.