Thomas Siegemund
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thomas Siegemund has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
A. Siegemund
MVZ Lab Dr. Reising-Ackermann and Colleagues, Center of Coagulation Disorders, Leipzig, Germany
16 shared publicationsU. Scholz
MVZ Lab Dr. Reising-Ackermann and Colleagues, Center of Coagulation Disorders, Leipzig, Germany
9 shared publicationsS. Petros
Medical ICU and Clinical Haemostaseology, Department of Internal Medicine, University of Leipzig, Leipzig
8 shared publicationsL. Engelmann
Centre of Internal Medicine, Clinical Haemostaseology and Adult Haemophilia Care Centre
7 shared publicationsAnnelie Siegemund
5 shared publicationsLothar Engelmann
3 shared publications
Latest Publications
- Open Access
- 23 April 2020
- Published by Elsevier in Research and Practice in Thrombosis and Haemostasis
- Vol. 4 (4) , 610-618
Inhibition of thrombin generation 12 hours after intake of direct oral anticoagulants
- 23 April 2020
- Published by Elsevier in Research and Practice in Thrombosis and Haemostasis
- Vol. 4 (4) , 610-618
Open AccessInhibition of thrombin generation 12 hours after intake of direct oral anticoagulants
- 1 January 2015
- Published by Georg Thieme Verlag KG in Hamostaseologie
- Vol. 35 (02) , 181-186
Thrombin generation and rotational thromboelastometry in the healthy adult population
Summary: Published data on thrombin generation variables and their correlation with thrombo - elastometry in the healthy population are scarce. This study aimed at assessing thrombin generation in adults and its correlation to classical rotational thromboelastometry (ROTEM).Thrombin generation was measured in platelet-poor plasma from healthy volunteers using the calibrated automated thrombogram (CAT) with 1 and 5 pmol/l tissue factor final concentration. Lag time, thrombin peak, time to thrombin peak and endogenous thrombin potential (ETP) were analyzed. ROTEM was performed without activator (NATEM) and data for clotting time, alpha angle, clot formation time and maximum clot firmness were correlated with those of thrombin generation.Altogether 132 persons (72 men, 60 women; median age: 48.0 years) were included. There was a positive non-linear correlation for age versus lag time (p < 0.001) and time to peak (p = 0.001), and almost linear correlation for age versus thrombin peak (p = 0.024) and ETP (p = 0.001), although with a moderate regression slope. Regarding ROTEM, there was a positive correlation between age and maximum clot firmness and alpha angle (p = 0.001), but a negative correlation between age and clotting time (p = 0.039). Comparing both assays, thrombin peak and ETP measured with a final tissue factor concentration of 5 pmol/l correlated significantly with alpha angle and maximum clot firmness.The age-related changes in CAT and ROTEM variables among adults are not linear. There is a significant correlation, although with a moderate slope, between data from CAT measured with 5 pmol/l tissue factor and ROTEM.
- 1 January 2015
- Published by Georg Thieme Verlag KG in Hamostaseologie
- Vol. 35 (02) , 181-186
Thrombin generation and rotational thromboelastometry in the healthy adult population
Summary: Published data on thrombin generation variables and their correlation with thrombo - elastometry in the healthy population are scarce. This study aimed at assessing thrombin generation in adults and its correlation to classical rotational thromboelastometry (ROTEM).Thrombin generation was measured in platelet-poor plasma from healthy volunteers using the calibrated automated thrombogram (CAT) with 1 and 5 pmol/l tissue factor final concentration. Lag time, thrombin peak, time to thrombin peak and endogenous thrombin potential (ETP) were analyzed. ROTEM was performed without activator (NATEM) and data for clotting time, alpha angle, clot formation time and maximum clot firmness were correlated with those of thrombin generation.Altogether 132 persons (72 men, 60 women; median age: 48.0 years) were included. There was a positive non-linear correlation for age versus lag time (p < 0.001) and time to peak (p = 0.001), and almost linear correlation for age versus thrombin peak (p = 0.024) and ETP (p = 0.001), although with a moderate regression slope. Regarding ROTEM, there was a positive correlation between age and maximum clot firmness and alpha angle (p = 0.001), but a negative correlation between age and clotting time (p = 0.039). Comparing both assays, thrombin peak and ETP measured with a final tissue factor concentration of 5 pmol/l correlated significantly with alpha angle and maximum clot firmness.The age-related changes in CAT and ROTEM variables among adults are not linear. There is a significant correlation, although with a moderate slope, between data from CAT measured with 5 pmol/l tissue factor and ROTEM.
- 1 January 2014
- Published by Georg Thieme Verlag KG in Hamostaseologie
- Vol. 34 (S 01) , S48-S62
Clot waveform analysis in patients with haemophilia A
Summary: Clot waveform analysis extends the interpretation of aPTT measurement curves. The curve is mathematically processed to obtain information about fibrin formation kinetics including semiquantitative determination of thrombin, prothrombinase and tenase activity. Patients, method: In this study the feasibility of clot waveform analysis for monitoring of haemophilia A was investigated using blood samples from healthy controls as well as haemophilia A patients under various clinical conditions. Results: Thrombin, prothrombinase and tenase activity show a high correlation to factor VIII levels. Tenase activity was found to exhibit a linear relationship to factor VIII levels over a very large concentration range and was able to discriminate patients with severe, moderate and mild haemophilia. Conclusion: Clot waveform analysis is an easy, fast and cheap method to access disturbances in clot formation and can be done without any additional measurements beside an aPTT.
- 1 January 2014
- Published by Georg Thieme Verlag KG in Hamostaseologie
- Vol. 34 (S 01) , S48-S62
Clot waveform analysis in patients with haemophilia A
Summary: Clot waveform analysis extends the interpretation of aPTT measurement curves. The curve is mathematically processed to obtain information about fibrin formation kinetics including semiquantitative determination of thrombin, prothrombinase and tenase activity. Patients, method: In this study the feasibility of clot waveform analysis for monitoring of haemophilia A was investigated using blood samples from healthy controls as well as haemophilia A patients under various clinical conditions. Results: Thrombin, prothrombinase and tenase activity show a high correlation to factor VIII levels. Tenase activity was found to exhibit a linear relationship to factor VIII levels over a very large concentration range and was able to discriminate patients with severe, moderate and mild haemophilia. Conclusion: Clot waveform analysis is an easy, fast and cheap method to access disturbances in clot formation and can be done without any additional measurements beside an aPTT.
- 1 June 2012
- Published by Elsevier in Thrombosis Research
- Vol. 129 (6) , 797-800
Thrombin generation in severe sepsis
- 1 June 2012
- Published by Elsevier in Thrombosis Research
- Vol. 129 (6) , 797-800
Thrombin generation in severe sepsis
- 1 April 2010
- Published by Elsevier in Thrombosis Research
- Vol. 125 (4) , 353-356
Standardisation of thrombin generation test - which reference plasma for TGT?: An international multicentre study
- 1 April 2010
- Published by Elsevier in Thrombosis Research
- Vol. 125 (4) , 353-356
Standardisation of thrombin generation test - which reference plasma for TGT?: An international multicentre study
- 9 December 2008
- Published by Elsevier in Brain Research
- Vol. 1244, 53-64
Immunohistochemical characterization and quantitative analysis of neurons in the myenteric plexus of the equine intestine
- 9 December 2008
- Published by Elsevier in Brain Research
- Vol. 1244, 53-64
Immunohistochemical characterization and quantitative analysis of neurons in the myenteric plexus of the equine intestine
- 1 November 2008
- Published by Elsevier in Journal of Thrombosis and Haemostasis
- Vol. 6 (11) , 1985-1987
Thrombin generation assay in a patient with acquired factor V inhibitor
- 1 November 2008
- Published by Elsevier in Journal of Thrombosis and Haemostasis
- Vol. 6 (11) , 1985-1987
Thrombin generation assay in a patient with acquired factor V inhibitor
- 1 January 2008
- Published by Springer Nature
- p. 212-216
Thrombin Generation — Comparison of ROTEM and Technothrombin TGA
- 1 January 2008
- Published by Springer Nature
- p. 212-216
Thrombin Generation — Comparison of ROTEM and Technothrombin TGA
- 1 January 2008
- Published by Springer Nature
- p. 71-74
Thrombin Generation in Children with Hemophilia and VWD — Comparing a Fluorimetric Method and ROTEM
- 1 January 2008
- Published by Springer Nature
- p. 71-74
Thrombin Generation in Children with Hemophilia and VWD — Comparing a Fluorimetric Method and ROTEM
- 30 June 2007
- Published by Wiley in Haemophilia
- Vol. 13 (5) , 677-679
Coagulation monitoring with thrombin generation test during endoscopic extraperitoneal radical prostatectomy for prostate cancer in a patient with severe haemophilia B
- 30 June 2007
- Published by Wiley in Haemophilia
- Vol. 13 (5) , 677-679
Coagulation monitoring with thrombin generation test during endoscopic extraperitoneal radical prostatectomy for prostate cancer in a patient with severe haemophilia B