  • Toward improving residual limb climate within prostheses for persons with lower limb loss: a technical note

    by Ashley D Knight, Brad D Hendershot, Todd J Sleeman, Christopher L Dearth, Felix Starker, Urs Schneider, Sara R Koehler-McNicholas, Kyle Barrons, Eric Nickel, Spencer Mion, et al.

    Background: Individuals with lower limb loss often wear a gel liner and enclosed socket for connecting to a terminal prosthetic device. Historically, a significant limitation to traditional liners and sockets is that they are thermal insulators, thereby trapping heat and moisture within, which can lead to numerous deleterious issues, including loss of suspension and residual limb skin problems, and, in turn, reductions in mobility, function, and overall quality of life. To mitigate these issues, new approaches are therefore needed to enhance the residual limb climate (e.g. breathability and air permeability), allowing the dispersal of heat and moisture from within the liner and socket. Methods: In this study, a multidisciplinary team sought to establish the feasibility of an innovative prosthetic liner-socket system, designed to improve residual limb climate by capitalizing on passive (i.e. nonpowered) ventilation to reduce temperature/moisture and improve socket comfort for persons with transtibial amputations. Focus group meetings, along with an iterative design approach, were implemented to establish innovative design and development concepts that led to a passively ventilated liner-socket system. Conclusions: Ex vivo design has supported the feasibility of developing a passively ventilated liner-socket. To build on these successes, future development and human subjects testing are needed to finalize a commercially viable system. Implementing a passively ventilated liner-socket system that improves residual limb health and comfort, without compromising function or mobility of the user, into standard clinical care may encourage a more active lifestyle and enhance the quality of life for individuals after lower limb loss.


  • Biomechanical characterization of the foot-ground interaction among Service members with unilateral transtibial limb loss performing unconstrained drop-landings: Effects of drop height and added mass

    by Jonathan M. Elrod, Barri L. Schnall, Timothy C. Mauntel, Nora L. Watson, Sara R. Koehler-McNicholas, Eric A. Nickel, Andrew H. Hansen, Christopher L. Dearth, Brad D. Hendershot

  • Open Access

    Gait and Balance Function Improves After 10 Weeks of Using a Wearable Sensory Neuroprosthesis in Persons with Peripheral Neuropathy and High Fall Risk – the walk2Wellness Trial

    by Lars Ie Oddsson, Teresa Bisson, Helen S Cohen, Laura Jacobs, Mohammad Khoshnoodi, Doris Kung, Lewis A Lipsitz, Brad Manor, Patricia McCracken, Yvonne Rumsey, et al.

    Background: Patients with sensory peripheral neuropathy (PN) commonly present with gait and balance problems increasing their risk of falls. The multi-site walk2Wellness trial investigates effects of long-term, home-based daily use of a wearable lower limb sensory neuroprosthesis on gait function, balance, quality of life and fall rates in a cohort of PN patients. The device (Walkasins®, RxFunction Inc., MN, USA) is designed to replace lost nerve function related to foot pressure sensation by providing directional tactile cues around the ankle reflecting foot pressure measurements during standing and walking activities. We hypothesized that previously shown short-term in-clinic improvements in gait and balance would be sustained after 10 weeks of use. Methods: Participants had a PN diagnosis with loss of plantar sensation associated with gait and balance problems, a Functional Gait Assessment (FGA) score <23 (cut-off for high fall risk), and ability to sense Leg Unit tactile stimuli. Clinical outcomes included FGA, Gait Speed, Timed Up&Go (TUG) and Four-Stage Balance Test. Patient-reported outcomes included Activities-Specific Balance Confidence (ABC) scale, Vestibular Disorders Activities of Daily Living Scale (VADL), PROMIS participation and satisfaction scores, pain rating, and falls. Evaluations were performed at baseline visit and after 2, 6, and 10 weeks. Subjects were not made aware of any changes in outcomes and no additional balance interventions were allowed. Results: Forty-five participants of 52 enrolled across four sites completed all in-clinic assessments. FGA scores improved from 15.0 at baseline to 19.1 at 10 weeks (p<0.000001), normal and fast gait speed from 0.86m/s to 0.95m/s (p<0.00005) and 1.24m/s to 1.33m/s (p<0.002), respectively, and TUG from 13.8s to 12.5s (p<0.012). Four-Stage Balance Test did not improve significantly. Several patient-reported outcomes were in normal range at baseline and remained largely unchanged. Interestingly, while FGA scores improved similarly across the baseline range, subjects with baseline ABC scores lower than 67% (cut-off for high fall risk) showed an increase in their ABC scores (from 49.9% to 59.3%, p<0.01), whereas subjects with baseline ABC scores above 67% showed a decrease (from 76.6% to 71.8%, p<0.019). Subjects who reported falls in the prior six months (n=25) showed a decrease in the number of fall-risk factors (from 5.1 to 4.3, p<0.023) as well as a decrease in fall rate from 13.8 to 7.4 falls/1000 days (p<0.014). Four subjects in the pre-study non-faller group (n=20) fell during the 10 weeks of the study. Conclusion: A wearable sensory neuroprosthesis may provide a new way to treat gait and balance problems and manage falls in high fall-risk patients with PN. Trial registration: ClinicalTrials.gov (# NCT03538756 )


  • A more compliant prosthetic foot better accommodates added load while walking among Servicemembers with transtibial limb loss

    by Barri L. Schnall, Christopher L. Dearth, Jonathan M. Elrod, Pawel R. Golyski, Sara R. Koehler-McNicholas, Samuel F. Ray, Andrew H. Hansen, Brad D. Hendershot


  • Open Access

    Neuromodulation to improve gait and balance function using a sensory neuroprosthesis in people who report insensate feet – A randomized control cross-over study

    by Sara R Koehler-McNicholas, Lori Danzl, Alana Y Cataldo, Lars I E Oddsson

    Peripheral neuropathy may cause loss of sensory information from plantar cutaneous mechanoreceptors that is important for balance control and falls management. The current study investigated short-term effects of using Walkasins, an external lower-limb sensory neuroprosthesis, on clinical outcomes of balance and gait in persons who reported peripheral neuropathy and balance problems. The device replaces lost plantar sensation with tactile balance information that modulates cutaneous mechanoreceptors above the ankle where sensation is intact. Thirty-one male community-dwelling Veterans, 56–84 years old with insensate feet and balance problems participated. Initial Functional Gait Assessment, gait speed, and 4-Stage Balance Test outcomes were assessed. After initial assessment, subjects were randomly assigned to either wearing Walkasins turned ON, or OFF, and outcomes were re-assessed following a set of standardized balance exercises. Following a one-hour rest and washout period, treatments were crossed-over between groups and a third outcomes assessment was performed. Before cross-over, 10 of 15 subjects in the ON-then-OFF group improved their Functional Gait Assessment score by at least four points, the Minimal Clinically Important Difference, compared to 5 of 16 in the OFF-then-ON group. After cross-over, 7 of 16 subjects in the OFF-then-ON group improved by at least four points versus 2 of 15 in the ON-then-OFF group. ON treatment was associated with a Functional Gait Assessment improvement of 4.4 ± 3.7 points versus 1.5 ± 1.2 for the OFF treatment (p<0.01). Overall, Functional Gait Assessment scores changed from 15.2 ± 4.8 at initial assessment to 21.1 ± 5.2 after final assessment (p<0.001). At the end of the two treatment sessions, 16 of the 31 individuals had improved their Functional Gait Assessment score beyond 23, indicating normal fall-risk status. Future studies should investigate long-term benefits of the device to reduce fall risk and actual falls in patients with peripheral neuropathy and balance problems.


  • Open Access

    Bimodal ankle-foot prosthesis for enhanced standing stability

    by Sara R Koehler-McNicholas, Billie C Savvas Slater, Karl Koester, Eric A Nickel, John E Ferguson, Andrew H Hansen

    Previous work suggests that to restore postural stability for individuals with lower-limb amputation, ankle-foot prostheses should be designed with a flat effective rocker shape for standing. However, most commercially available ankle-foot prostheses are designed with a curved effective rocker shape for walking. To address the demands of both standing and walking, we designed a novel bimodal ankle-foot prosthesis that can accommodate both functional modes using a rigid foot plate and an ankle that can lock and unlock. The primary objective of this study was to determine if the bimodal ankle-foot system could improve various aspects of standing balance (static, dynamic, and functional) and mobility in a group of Veterans with lower-limb amputation (n = 18). Standing balance was assessed while subjects completed a series of tests on a NeuroCom Clinical Research System (NeuroCom, a Division of Natus, Clackamas, OR), including a Sensory Organization Test, a Limits of Stability Test, and a modified Motor Control Test. Few statistically significant differences were observed between the locked and unlocked ankle conditions while subjects completed these tests. However, in the absence of visual feedback, the locked bimodal ankle appeared to improve static balance in a group of experienced lower-limb prosthesis users whose PLUS-M mobility rating was higher than approximately 73% of the sample population used to develop the PLUS-M survey. Given the statistically significant increase in mean equilibrium scores between the unlocked and locked conditions (p = 0.004), future testing of this system should focus on new amputees and lower mobility users (e.g., Medicare Functional Classification Level K1 and K2 prosthesis users). Furthermore, commercial implementation of the bimodal ankle-foot system should include a robust control system that can automatically switch between modes based on the user’s activity.


  • Open Access

    Mechanical and dynamic characterization of prosthetic feet for high activity users during weighted and unweighted walking

    by Sara R Koehler-McNicholas, Eric A Nickel, Kyle Barrons, Kathryn E Blaharski, Clifford A Dellamano, Samuel F Ray, Barri L Schnall, Brad D Hendershot, Andrew H Hansen

    Many Service members and Veterans with lower-limb amputations have the potential for high function and the desire to resume physically demanding occupations that require them to carry heavy loads (e.g., military service, firefighters, farmers, ranchers, construction workers). However, it is currently unclear which prosthetic feet best accommodate heavy load carriage while also providing good overall function and mobility during unweighted activities. The main objective of this study was to investigate the ability of currently available prosthetic ankle-foot systems to accommodate weighted walking by examining the mechanical characteristics (i.e., forefoot stiffness) and dynamic function (i.e., rocker radius, effective foot length ratio, and late-stance energy return) of prosthetic feet designed for high activity users. Load versus deflection curves were obtained for nine prosthetic ankle-foot systems using a servohydraulic test frame and load cell. Effective roll-over shape characteristics and late-stance energy return measures were then obtained using quantitative gait analysis for three users with unilateral, transtibial amputation. Results from mechanical and dynamic testing showed that although forefoot stiffness varied across the nine feet investigated in this study, changes measured in roll-over shape radius and effective foot length ratio were relatively small in response to weighted walking. At the same time, prosthetic feet with more compliant forefoot keel structures appeared to provide more late-stance energy return compared to feet with stiffer forefoot keel structures. These results suggest that prosthetic ankle-foot systems with compliant forefoot keel structures may better accommodate weighted walking by reducing the metabolic cost of physically demanding activities. However, to more fully understand the biomechanical and functional implications of these results, other factors, such as the residual-limb strength of the user and the overall stiffness profile of the prosthetic foot, should also be considered.


  • Open Access

    Improving Automatic Control of an Ankle-Foot Prosthesis Using Machine Learning Algorithms

    by Stuart R. Fairhurst, Sara R. Koehler-McNicholas, Billie C. S. Slater, Eric A. Nickel, Karl A. Koester, Gregory O. Voss, Andrew H. Hansen, John E. Ferguson

    Most commercially available lower-limb prostheses are designed for walking, not for standing. The Minneapolis VA Health Care System has developed a bimodal prosthetic ankle-foot system with distinct modes for walking and standing [1]. With this device, a prosthesis user can select standing or walking mode in order to maximize standing stability or walking functionality, depending on the activity and context. Additionally, the prosthesis was designed to allow for an “automatic mode” to switch between standing and walking modes based on readings from an onboard Inertial Measurement Unit (IMU) without requiring user interaction to manually switch modes. A smartphone app was also developed to facilitate changing between walking, standing and automatic modes. The prosthesis described in [1] was used in a pilot study with 18 Veterans with lower-limb amputations to test static, dynamic, and functional postural stability. As part of the study, 17 Veterans were asked for qualitative feedback on the bimodal ankle-foot system (Table 1). The majority of participants (82%) expressed an interest in having an automatic mode. The participants also indicated that the automatic mode would need to reach walking mode on their first step and to lock the ankle quickly once the standing position was achieved. When asked about how they wanted to control the modes of the prosthesis, 82% wanted to use a physical switch and only 12% wanted to use a smartphone app. The results indicated that the following major design changes would be needed: 1) A fast and accurate automatic mode 2) A physical switch for mode changes This paper describes the use of machine learning algorithms to create an improved automatic mode and the use of stakeholder feedback to design a physical switch for the bimodal ankle-foot system.


  • Open Access

    The influence of a hydraulic prosthetic ankle on residual limb loading during sloped walking

    by Sara R. Koehler-McNicholas, Eric A. Nickel, Joseph Medvec, Kyle Barrons, Spencer Mion, Andrew H. Hansen

    In recent years, numerous prosthetic ankle-foot devices have been developed to address the demands of sloped walking for individuals with lower-limb amputation. The goal of this study was to compare the performance of a passive, hydraulic ankle-foot prosthesis to two related, non-hydraulic ankles based on their ability to minimize the socket reaction moments of individuals with transtibial amputation during a range of sloped walking tasks. After a two-week accommodation period, kinematic data were collected on seven subjects with a transtibial amputation walking on an instrumented treadmill set at various slopes. Overall, this study was unable to find significant differences in the torque at the distal end of the prosthetic socket between an ankle-foot prosthesis with a hydraulic range-of-motion and other related ankle-foot prosthesis designs (rigid ankle, multiaxial ankle) during the single-support phase of walking. In addition, socket comfort and perceived exertion were not significantly different for any of the ankle-foot prostheses tested in this study. These results suggest the need for further work to determine if more advanced designs (e.g., those with microprocessor control of hydraulic features, powered ankle-foot designs) can provide more biomimetic function to prosthesis users.


  • The biomechanical response of persons with transfemoral amputation to variations in prosthetic knee alignment during level walking

    by Sara R. Koehler-McNicholas, Robert D. Lipschutz, Steven A. Gard

    Prosthetic alignment is an important factor in the overall fit and performance of a lower-limb prosthesis. However, the association between prosthetic alignment and control strategies used by persons with transfemoral amputation to coordinate the movement of a passive prosthetic knee is poorly understood. This study investigated the biomechanical response of persons with transfemoral amputation to systematic perturbations in knee joint alignment during a level walking task. Quantitative gait data were collected for three alignment conditions: bench alignment, 2 cm anterior knee translation (ANT), and 2 cm posterior knee translation (POST). In response to a destabilizing alignment perturbation (i.e., the ANT condition), participants significantly increased their early-stance hip extension moment, confirming that persons with transfemoral amputation rely on a hip extensor strategy to maintain knee joint stability. However, participants also decreased the rate at which they loaded their prosthesis, decreased their affected-side step length, increased their trunk flexion, and maintained their prosthesis in a more vertical posture at the time of opposite toe off. Collectively, these results suggest that persons with transfemoral amputation rely on a combination of strategies to coordinate stance-phase knee flexion. Further, comparatively few significant changes were observed in response to the POST condition, suggesting that a bias toward posterior alignment may have fewer implications in terms of stance-phase, knee joint control.