Xiaoqi Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xiaoqi Li has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Huabei Jiang
Department of Medical Engineering University of South Florida Tampa Florida USA
10 shared publications Lei Yao
Department of Biomedical Engineering, University of Florida, Gainesville, Florida 32611
5 shared publications- Lei Xi
Department of Biomedical Engineering Southern University of Science and Technology Shenzhen Guangdong China
4 shared publications - Coy Don Heldermon
Department of Medicine, University of Florida, Gainesville, FL 32611, USA
3 shared publications Huabei Jiang
2 shared publicationsLei Xi
Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611
2 shared publications
Latest Publications
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 744-749
End-Effector Force Estimation for Robotic Manipulators from Motor Current Measurements
End-effector force of the robotic manipulator plays an important role in force control. Generally, conventional end-effector force measurement approaches need additional sensors, e.g., the force/torque (F/T) sensor and the joint torque sensor, which raise the cost and introduce complexity into manipulators’ mechanical and electrical design. Therefore, we propose an approach to estimate the end-effector contact force of a manipulator utilizing the motor current measurement without any additional sensors. By building the dynamics model of the manipulator with external wrench, the proposed approach utilizes the friction torque model of the joints to improve the precise of the wrench estimation. Additionally, In order to identify the parameters of motors and the friction torque model, a parameter identification method based on non-linear least squares regression is introduced. The experiments are implemented on the robot IRIC-I which is developed in our lab. Experimental results indicate that the end-effector force can be reliably estimated without any extra sensors, and show the potential of utilizing the estimated end-effector force in force control of the robotic manipulator.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 744-749
End-Effector Force Estimation for Robotic Manipulators from Motor Current Measurements
End-effector force of the robotic manipulator plays an important role in force control. Generally, conventional end-effector force measurement approaches need additional sensors, e.g., the force/torque (F/T) sensor and the joint torque sensor, which raise the cost and introduce complexity into manipulators’ mechanical and electrical design. Therefore, we propose an approach to estimate the end-effector contact force of a manipulator utilizing the motor current measurement without any additional sensors. By building the dynamics model of the manipulator with external wrench, the proposed approach utilizes the friction torque model of the joints to improve the precise of the wrench estimation. Additionally, In order to identify the parameters of motors and the friction torque model, a parameter identification method based on non-linear least squares regression is introduced. The experiments are implemented on the robot IRIC-I which is developed in our lab. Experimental results indicate that the end-effector force can be reliably estimated without any extra sensors, and show the potential of utilizing the estimated end-effector force in force control of the robotic manipulator.
- 18 August 2015
- Published by Wiley in Medical Physics
- Vol. 42 (9) , 5321-5328
High resolution functional photoacoustic tomography of breast cancer
Purpose: To evaluate the feasibility of functional photoacoustic tomography (fPAT) for high resolution detection and characterization of breast cancer and to demonstrate for the first time quantitative hemoglobin concentration and oxygen saturation images of breasts that were formed with model‐based reconstruction of tomographic photoacoustic data.Methods: The study was HIPAA compliant and was approved by the university institutional review board. Written informed consents were obtained from all the participants. Ten cases, including six cancer and four healthy (mean age = 50 yr; age range = 41–66 yr), were examined. Functional images of breast tissue including absolute total hemoglobin concentration (HbT) and oxygen saturation (StO2%) were obtained by fPAT and cross validated with magnetic resonance imaging (MRI) readings and/or histopathology.Results: HbT and StO2% maps from all six pathology‐confirmed cancer cases (60%) show clear detection of tumor, while MR images indicate clear detection of tumor for five of six cancer cases; one small tumor was read as near‐complete‐resolution by MRI. The average HbT and StO2% value of suspicious lesion area for the cancer cases was 61.6 ± 18.9 μM/l and 67.5% ± 5.2% compared to 25.6 ± 7.4 μM/l and 65.2% ± 3.8% for background normal tissue.Conclusions: fPAT has the potential to be a significant add‐on in breast cancer detection and characterization as it provides submillimeter resolution functional images of breast lesions.
- 18 August 2015
- Published by Wiley in Medical Physics
- Vol. 42 (9) , 5321-5328
High resolution functional photoacoustic tomography of breast cancer
Purpose: To evaluate the feasibility of functional photoacoustic tomography (fPAT) for high resolution detection and characterization of breast cancer and to demonstrate for the first time quantitative hemoglobin concentration and oxygen saturation images of breasts that were formed with model‐based reconstruction of tomographic photoacoustic data.Methods: The study was HIPAA compliant and was approved by the university institutional review board. Written informed consents were obtained from all the participants. Ten cases, including six cancer and four healthy (mean age = 50 yr; age range = 41–66 yr), were examined. Functional images of breast tissue including absolute total hemoglobin concentration (HbT) and oxygen saturation (StO2%) were obtained by fPAT and cross validated with magnetic resonance imaging (MRI) readings and/or histopathology.Results: HbT and StO2% maps from all six pathology‐confirmed cancer cases (60%) show clear detection of tumor, while MR images indicate clear detection of tumor for five of six cancer cases; one small tumor was read as near‐complete‐resolution by MRI. The average HbT and StO2% value of suspicious lesion area for the cancer cases was 61.6 ± 18.9 μM/l and 67.5% ± 5.2% compared to 25.6 ± 7.4 μM/l and 65.2% ± 3.8% for background normal tissue.Conclusions: fPAT has the potential to be a significant add‐on in breast cancer detection and characterization as it provides submillimeter resolution functional images of breast lesions.
- 1 January 2014
- Published by Optica Publishing Group
- p. BS3A.66
Monitoring neoadjuvant chemotherapy in breast cancer using quantitative photoacoustic tomography
Quantitative photoacoustic tomography effectively monitor tumor response to neoadjuvant chemotherapy in breast cancer is presented. Recovered absolute total hemoglobin concentration and oxygen saturation maps are strongly correlated with MRI and ultrasound images.
- 1 January 2014
- Published by Optica Publishing Group
- p. BS3A.66
Monitoring neoadjuvant chemotherapy in breast cancer using quantitative photoacoustic tomography
Quantitative photoacoustic tomography effectively monitor tumor response to neoadjuvant chemotherapy in breast cancer is presented. Recovered absolute total hemoglobin concentration and oxygen saturation maps are strongly correlated with MRI and ultrasound images.
- 1 January 2014
- Published by Optica Publishing Group
- p. BS3A.63
Functional photoacoustic tomography of breast cancer: Pilot clinical results
We present a pilot clinical study for breast cancer diagnosis and neoadjuvant chemotherapy monitoring using quantitative multispectral photoacoustic tomography. Absolute total hemoglobin concentration and oxygen saturation maps from several breast cancer patients are obtained for the first time and compared with the MR images and biopsy reports.
- 1 January 2014
- Published by Optica Publishing Group
- p. BS3A.63
Functional photoacoustic tomography of breast cancer: Pilot clinical results
We present a pilot clinical study for breast cancer diagnosis and neoadjuvant chemotherapy monitoring using quantitative multispectral photoacoustic tomography. Absolute total hemoglobin concentration and oxygen saturation maps from several breast cancer patients are obtained for the first time and compared with the MR images and biopsy reports.
- 1 January 2014
- Published by Optica Publishing Group
- p. BS3A.68
Spatially variant total variation minimization improves photoacoustic tomography
We present a new method that can enhance quantitative recovery of optical absorption coefficient in heterogeneous media from noisy photoacoustic data by incorporating spatially variant information into total variation minimization with the finite element method.
- 1 January 2014
- Published by Optica Publishing Group
- p. BS3A.68
Spatially variant total variation minimization improves photoacoustic tomography
We present a new method that can enhance quantitative recovery of optical absorption coefficient in heterogeneous media from noisy photoacoustic data by incorporating spatially variant information into total variation minimization with the finite element method.
- 23 January 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (4) , 999-1011
Impact of inhomogeneous optical scattering coefficient distribution on recovery of optical absorption coefficient maps using tomographic photoacoustic data
We present a study through extensive simulation that considers the impact of inhomogeneous optical scattering coefficient distribution on recovery of optical absorption coefficient maps using tomographic photoacoustic data collected from media mimicking breast tissue. We found that while the impact of scattering heterogeneities/targets is modest on photoacoustic recovery of optical absorption coefficients, the impact of scattering contrast caused by adipose tissue, a layer of normal tissue along the boundary of the breast, is dramatic on reconstruction of optical absorption coefficients using photoacoustic data-up to 25.8% relative error in recovering the absorption coefficient is estimated in such cases. To overcome this problem, we propose a new method to enhance photoacoustic recovery of the optical absorption coefficient in heterogeneous media by considering inhomogeneous scattering coefficient distribution provided by diffuse optical tomography (DOT). Results from extensive simulations show that photoacoustic recovery of absorption coefficient maps can be improved considerably with a priori scattering information from DOT.
- 23 January 2013
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (4) , 999-1011
Impact of inhomogeneous optical scattering coefficient distribution on recovery of optical absorption coefficient maps using tomographic photoacoustic data
We present a study through extensive simulation that considers the impact of inhomogeneous optical scattering coefficient distribution on recovery of optical absorption coefficient maps using tomographic photoacoustic data collected from media mimicking breast tissue. We found that while the impact of scattering heterogeneities/targets is modest on photoacoustic recovery of optical absorption coefficients, the impact of scattering contrast caused by adipose tissue, a layer of normal tissue along the boundary of the breast, is dramatic on reconstruction of optical absorption coefficients using photoacoustic data-up to 25.8% relative error in recovering the absorption coefficient is estimated in such cases. To overcome this problem, we propose a new method to enhance photoacoustic recovery of the optical absorption coefficient in heterogeneous media by considering inhomogeneous scattering coefficient distribution provided by diffuse optical tomography (DOT). Results from extensive simulations show that photoacoustic recovery of absorption coefficient maps can be improved considerably with a priori scattering information from DOT.
- 22 October 2012
- Published by AIP Publishing in Applied Physics Letters
- Vol. 101 (17) , 173702
Variable-thickness multilayered polyvinylidene fluoride transducer with improved sensitivity and bandwidth for photoacoustic imaging
The performance of photoacoustic imaging (PAI) is critically dependent on the sensitivity and bandwidth of the transducer. Here, we report the design and fabrication of a polyvinylidene fluoride ultrasonic transducer with variable-thickness layers that demonstrates significantly improved sensitivity and bandwidth. We show that the multilayered transducer provides more than 2-fold increase in sensitivity and more than 65% improvement in bandwidth compared with the conventional single-layer transducer. Photoacoustic imaging of mouse brain with the intact skull and scalp is conducted to demonstrate the power of the multilayered transducer for resolving brain structure in an in vivo setting.
- 22 October 2012
- Published by AIP Publishing in Applied Physics Letters
- Vol. 101 (17) , 173702
Variable-thickness multilayered polyvinylidene fluoride transducer with improved sensitivity and bandwidth for photoacoustic imaging
The performance of photoacoustic imaging (PAI) is critically dependent on the sensitivity and bandwidth of the transducer. Here, we report the design and fabrication of a polyvinylidene fluoride ultrasonic transducer with variable-thickness layers that demonstrates significantly improved sensitivity and bandwidth. We show that the multilayered transducer provides more than 2-fold increase in sensitivity and more than 65% improvement in bandwidth compared with the conventional single-layer transducer. Photoacoustic imaging of mouse brain with the intact skull and scalp is conducted to demonstrate the power of the multilayered transducer for resolving brain structure in an in vivo setting.
- 25 July 2012
- Published by Elsevier in Optics Communications
- Vol. 285 (21-22) , 4632-4637
Morphological characterization of cells in concentrated suspensions using multispectral diffuse optical tomography
- 25 July 2012
- Published by Elsevier in Optics Communications
- Vol. 285 (21-22) , 4632-4637
Morphological characterization of cells in concentrated suspensions using multispectral diffuse optical tomography
- 18 April 2012
- Published by Wiley in Medical Physics
- Vol. 39 (5) , 2584-2594
Design and evaluation of a hybrid photoacoustic tomography and diffuse optical tomography system for breast cancer detection
Purpose: : The authors present the design and evaluation of a second‐generation (G2) hybrid photoacoustic tomography (PAT) and diffuse optical tomography (DOT) imaging system for detection of breast cancer. The combined PAT/DOT system takes full advantages of two different modalities to provide complementary information and most accurate recovery of tissue optical properties.Methods: : This system was designed to produce cross‐section images of breast tissue with a ring‐shaped home‐made array of 64 wideband acoustic transducers combined with an array of 16/16 source/detector optical fiber bundles. A scanning light delivery system was built to illuminate a large area of breast tissue for optimized tissue penetration. Finite element reconstruction methods for quantitative PAT and DOT were utilized to recover absorption and scattering coefficients of tissue‐mimicking phantoms andex vivo tumor tissue.Results: : Performances of the acoustic transducer array and the PAT/DOT system were investigated in detail. Frequency response of the transducers is from 380 kHz to 1.48 MHz and maximum frequency response is up to 2 MHz. Directivity of a single element in the array is ±30°. The PAT/DOT system offers a spatial resolution of ∼0.5 mm for PAT and of ∼4.0 mm for DOT. Quantitatively accurate absorption and scattering coefficients were obtained from both the phantom andex vivo experiments.Conclusions: : The PAT/DOT system provided better PAT images when the targets were smaller in size and located near the center of the background phantom, while better DOT images were obtained when the targets were larger in size and located away from the center of the background. The successful results obtained from both the phantom andex vivo experiments will allow us to test the hybrid system in humans with breast cancer in the near future.
- 18 April 2012
- Published by Wiley in Medical Physics
- Vol. 39 (5) , 2584-2594
Design and evaluation of a hybrid photoacoustic tomography and diffuse optical tomography system for breast cancer detection
Purpose: : The authors present the design and evaluation of a second‐generation (G2) hybrid photoacoustic tomography (PAT) and diffuse optical tomography (DOT) imaging system for detection of breast cancer. The combined PAT/DOT system takes full advantages of two different modalities to provide complementary information and most accurate recovery of tissue optical properties.Methods: : This system was designed to produce cross‐section images of breast tissue with a ring‐shaped home‐made array of 64 wideband acoustic transducers combined with an array of 16/16 source/detector optical fiber bundles. A scanning light delivery system was built to illuminate a large area of breast tissue for optimized tissue penetration. Finite element reconstruction methods for quantitative PAT and DOT were utilized to recover absorption and scattering coefficients of tissue‐mimicking phantoms andex vivo tumor tissue.Results: : Performances of the acoustic transducer array and the PAT/DOT system were investigated in detail. Frequency response of the transducers is from 380 kHz to 1.48 MHz and maximum frequency response is up to 2 MHz. Directivity of a single element in the array is ±30°. The PAT/DOT system offers a spatial resolution of ∼0.5 mm for PAT and of ∼4.0 mm for DOT. Quantitatively accurate absorption and scattering coefficients were obtained from both the phantom andex vivo experiments.Conclusions: : The PAT/DOT system provided better PAT images when the targets were smaller in size and located near the center of the background phantom, while better DOT images were obtained when the targets were larger in size and located away from the center of the background. The successful results obtained from both the phantom andex vivo experiments will allow us to test the hybrid system in humans with breast cancer in the near future.
- 1 January 2012
- Published by Optica Publishing Group
- p. BSu3A.50
Quantitative photoacoustic tomography assisted by diffuse optical tomography: A simulation study
We present a new method that can enhance quantitative recovery of optical absorption coefficient in heterogeneous media from photoacoustic data by considering inhomogeneous scattering coefficient distribution provided by diffuse optical tomography.
- 1 January 2012
- Published by Optica Publishing Group
- p. BSu3A.50
Quantitative photoacoustic tomography assisted by diffuse optical tomography: A simulation study
We present a new method that can enhance quantitative recovery of optical absorption coefficient in heterogeneous media from photoacoustic data by considering inhomogeneous scattering coefficient distribution provided by diffuse optical tomography.