XHXiao-Juan Hu

Xiao-Juan Hu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiao-Juan Hu has a total of 66 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Data-knowledge feature fusion for PPG-based blood pressure prediction: Low-dimensional extraction via functional data analysis and knowledge constraint

    by Qingfeng Tang, Huihui Hu, Chao Tao, Pengcheng Ding, Guowei Dai, Guangjun Wang, Xiaojuan Hu, Benyue Su, Jiatuo Xu, Hui An


  • Open Access

    A short recorded pulse dataset for vascular age prediction in China

    by Qingfeng Tang, Pengcheng Ding, Guowei Dai, Liangliang Zhang, Guangjun Wang, Benyue Su, Xiaojuan Hu, Ji Cui, Haoyu Qu, Hui An

    Early assessment of cardiovascular disease risk plays an important role in preventing cardiovascular disease, vascular age (VA) is an important indicator for early screening of cardiovascular disease risk. This study presents a pulse signal-based dataset for VA prediction. The dataset comprises 226 subjects with 1364 pulse cycles, spanning both sexes (49.6% male, 50.4% female) and an age range of 20 to 69 years. Pulse signals were denoised by Savitzky-Golay filters, and 4th-order derivatives were calculated to extract the features of pulse signal. We applied the classic statistical model Klemera Doubal method (KDM) and five artificial intelligence models to predict VA. The experimental results showed that these models can predict VA with high accuracy and stability. It indicates that using pulse signals to predict VA is a simple, non-invasive, and effective method for assessing vascular health.


  • Open Access

    A Risk Warning Model for Anemia Based on Facial Visible Light Reflectance Spectroscopy: Cross-Sectional Study

    by Yahan Zhang, Yi Chun, Hongyuan Fu, Wen Jiao, Jizhang Bao, Tao Jiang, Longtao Cui, Xiaojuan Hu, Ji Cui, Xipeng Qiu, et al.

    Background: Anemia is a global public health issue causing symptoms such as fatigue, weakness, and cognitive decline. Furthermore, anemia is associated with various diseases and increases the risk of postoperative complications and mortality. Frequent invasive blood tests for diagnosis also pose additional discomfort and risks to patients. Objective: This study aims to assess the facial spectral characteristics of patients with anemia and to develop a predictive model for anemia risk using machine learning approaches. Methods: Between August 2022 and September 2023, we collected facial image data from 78 anemic patients who met the inclusion criteria from the Hematology Department of Shanghai Hospital of Traditional Chinese Medicine. Between March 2023 and September 2023, we collected data from 78 healthy adult participants from Shanghai Jiading Community Health Center and Shanghai Gaohang Community Health Center. A comprehensive statistical analysis was performed to evaluate differences in spectral characteristics between the anemic patients and healthy controls. Then, we used 10 different machine learning algorithms to create a predictive model for anemia. The least absolute shrinkage and selection operator was used to analyze the predictors. We integrated multiple machine learning classification models to identify the optimal model and developed Shapley additive explanations (SHAP) for personalized risk assessment. Results: The study identified significant differences in facial spectral features between anemic patients and healthy controls. The support vector machine classifier outperformed other classification models, achieving an accuracy of 0.875 (95% CI 0.825-0.925) for distinguishing between the anemia and healthy control groups. In the SHAP interpretation of the model, forehead-570 nm, right cheek-520 nm, right zygomatic-570 nm, jaw-570 nm, and left cheek-610 nm were the features with the highest contributions. Conclusions: Facial spectral data demonstrated clinical significance in anemia diagnosis, and the early warning model for anemia risk constructed based on spectral information demonstrated a high accuracy rate.


  • Open Access

    Objective Evaluation of Pulse Width Using an Array Pulse Diagram

    by Zi-Juan Bi, Ji Cui, Xing-Hua Yao, Xiao-Juan Hu, Si-Han Wang, Meng-Chen Liang, Zhi-Hui Zhou, Jia-Tuo Xu

    Background: Pulse width, which can reflect qi, blood excess, and deficiency, has been used for diagnosing diseases and determining the prognosis in traditional Chinese medicine (TCM). This study aimed to devise an objective method to measure the pulse width based on an array pulse diagram for objective diagnosis. Methods: The channel 6, the region wherein the pulse wave signal is the strongest, is located in the middle of the pulse sensor array and at the guan position of cunkou during data collection. Therefore, the main wave (h1) time of the pulse wave was collected from the channel 6 through calculation. The left h1 time was collected from the remaining 11 channels. The amplitudes at these time points were extracted as the h1 amplitudes for each channel. However, the pulse width could not be calculated accurately at 12 points. Consequently, a bioharmonic spline interpolation algorithm was used to interpolate the h1 amplitude data obtained from the horizontal and vertical points, yielding 651 (31 × 21) h1 amplitude data. The 651 data points were converted into a heat map to intuitively calculate the pulse width. The pulse width was calculated by multiplying the number of grids on the vertical axis with the unit length of the grid. The pulse width was determined by TCM doctors to verify the pulse width measurement accuracy. Meanwhile, a color Doppler ultrasound examination of the volunteers’ radial arteries was performed and the intravascular meridian widths of the radial artery compared with the calculated pulse widths to determine the reliability. Results: The pulse width determined using the maximal h1 amplitude method was comparable with the radial artery intravascular meridian widths measured using color Doppler ultrasound. The h1 amplitude was higher in the high blood pressure group and the pulse width was greater. Conclusions: The pulse width determined using the maximal h1 amplitude was objective and accurate. Comparison between the pulse widths of the normal and high blood pressure groups verified the reliability of the method.


  • Open Access

    Research of the Distribution of Tongue Features of Diabetic Population Based on Unsupervised Learning Technology

    by Jun Li, Longtao Cui, Liping Tu, Xiaojuan Hu, Sihan Wang, Yulin Shi, Jiayi Liu, Changle Zhou, Yongzhi Li, Jingbin Huang, et al.

    Background. The prevalence of diabetes increases year by year, posing a severe threat to human health. Current treatments are difficult to prevent the progression of diabetes and its complications. It is imperative to carry out individualized treatment of diabetes, but current diagnostic methods are difficult to specify an individualized treatment plan. Objective. Clarify the distribution law of tongue features of the diabetic population, and provide the diagnostic basis for individualized treatment of traditional Chinese medicine (TCM) in the treatment of diabetes. Methods. We use the TFDA-1 tongue diagnosis instrument to collect tongue images of people with diabetes and accurately calculate the color features, texture features, and tongue coating ratio features through the Tongue Diagnosis Analysis System (TDAS). Then, we used K-means and Self-organizing Maps (SOM) networks to analyze the distribution of tongue features in diabetic people. Statistical analysis of TDAS features was used to identify differences between clusters. Results. The silhouette coefficient of the K-means clustering result is 0.194, and the silhouette coefficient of the SOM clustering result is 0.127. SOM Cluster 3 and Cluster 4 are derived from K-means Cluster 1, and the intersections account for (76.7% 97.5%) and (22.3% and 70.4%), respectively. K-means Cluster 2 and SOM Cluster 1 are highly overlapping, and the intersection accounts for the ratios of 66.9% and 95.0%. K-means Cluster 3 and SOM Cluster 2 are highly overlaid, and the intersection ratio is 94.1% and 82.1%. For the clustering results of K-means, TB-a and TC-a of Cluster 3 are the highest ( ), TB-a of Cluster 2 is the lowest ( ), and TB-a of Cluster 1 is between Cluster 2 and Cluster 3 ( ). Cluster 1 has the highest TB-b and TC-b ( ), Cluster 2 has the lowest TB-b and TC-b ( ), and TB-b and TC-b of Cluster 3 are between Cluster 1 and Cluster 2 ( ). Cluster 1 has the highest TB-ASM and TC-ASM ( ), Cluster 3 has the lowest TB-ASM and TC-ASM ( ), and TB-ASM and TC-ASM of Cluster 2 are between the Cluster 1 and Cluster 3 ( ). CON, ENT, and MEAN show the opposite trend. Cluster 2 had the highest Per-all ( ). SOM divides K-means Cluster 1 into two categories. There is almost no difference in texture features between Cluster 3 and Cluster 4 in the SOM clustering results. Cluster 3’s TB-L, TC-L, and Per-all are lower than Cluster 4 ( ), Cluster 3’s TB-a, TC-a, TB-b, TC-b, and Per-part are higher than Cluster 4 ( ). Conclusions. The precise tongue image features calculated by TDAS are the basis for characterizing the disease state of diabetic people. Unsupervised learning technology combined with statistical analysis is an important means to discover subtle changes in the tongue features of diabetic people. The machine vision analysis method based on unsupervised machine learning technology realizes the classification of the diabetic population based on fine tongue features. It provides a diagnostic basis for the designated diabetes TCM treatment plan.


  • Open Access

    A Study of Logistic Regression for Fatigue Classification Based on Data of Tongue and Pulse

    by Yu Lin Shi, Tao Jiang, Xiao Juan Hu, Ji Cui, Long Tao Cui, Li Ping Tu, Xing Hua Yao, Jing Bin Huang, Jia Tuo Xu

    Background and Objective. Fatigue is a subjective symptom which is hard to quantify, it is prevalent in the subhealth and disease population, and there is still no accurate and stable method to distinguish disease fatigue from subhealth fatigue. Tongue diagnosis and pulse diagnosis are the reflection of the overall state of the body, and the modern research of tongue diagnosis and pulse diagnosis has made great progress. This study aims to explore the distribution rules of tongue and pulse data in a disease fatigue and subhealth fatigue population and evaluate the contribution rate of tongue and pulse data to fatigue diagnosis through modeling. Methods. The Tongue and Face Diagnosis Analysis-1 instrument and Pulse Diagnosis Analysis-1 instrument were used to collect the tongue image and sphygmogram of the subhealth fatigue population (n=252) and disease fatigue population (n=1160), and we mainly analyzed the tongue and pulse characteristics and constructed the classification model by using the logistic regression method. Results. The results showed that subhealth fatigue people and disease fatigue people had different characteristics of tongue and pulse, and the logistic regression model based on tongue and pulse data had a good classification effect. The accuracies of models of healthy controls and subhealth fatigue, subhealth fatigue and disease fatigue, and healthy controls and disease fatigue were 68.29, 81.18, and 84.73, and the AUC was 0.698, 0.882, and 0.924, respectively. Conclusion. This study provided a new noninvasive method for the fatigue diagnosis from the perspective of objective tongue and pulse data, and the modern tongue diagnosis and pulse diagnosis have good application prospects.


  • Open Access

    Assessment Parameters for Arrayed Pulse Wave Analysis and Application in Hypertensive Disorders

    by Zi-Juan Bi, Xing-Hua Yao, Xiao-Juan Hu, Pei Yuan, Xiao-Jing Guo, Zhi-Ling Guo, Si-Han Wang, Jun Li, Yu-Lin Shi, Jia-Cai Li, et al.

    Study on the objectivity of pulse diagnosis is inseparable from the instruments to obtain the pulse waves. The single-pulse diagnostic instrument is relatively mature in acquiring and analysing pulse waves, but the pulse information captured by single-pulse diagnostic instrument is limited. The sensor arrays can simulate rich sense of the doctors fingers and catch multipoint and multiparameter array signals. How to analyse the acquired array signals is still a major problem in the objective research of pulse diagnosis. The goal of this study was to establish methods for analysing arrayed pulse waves and preliminarily apply them in hypertensive disorders. While a sensor array can be used for the real-time monitoring of twelve pulse wave channels, for each subject in this study, only the pulse wave signals of the left hand at the guan location were obtained. We calculated the average pulse wave (APW) per channel over a thirty-second interval. The most representative pulse wave (MRPW) and the APW were matched by their correlation coefficient (CC). The features of the MRPW and the features that corresponded to the array pulse volume (APV) parameters were identified manually. Finally, a clinical trial was conducted to detect these feature performance indicators in patients with hypertensive disorders. The independent-samples t-tests and the MannWhitney U-tests were performed to assess the differences in these pulse parameters between the healthy and hypertensive groups. We found that the radial passage (RP) APVh1, APVh3, APVh4, APVh3/h1 (Ph4/h1 (Ph4, APVh3/h1 (Ph4/h1 (Phe mean APVh3, APVh3/h1 (Ph4/h1 (Ph4/h1 (P<0.05) was clearly elevated in the hypertensive group. These results provide a preliminary validation of this novel approach for determining the APV by arrayed pulse wave analysis. In conclusion, we identified effective indicators of hypertensive vascular function. Traditional Chinese medicine (TCM) pulses comprise multidimensional information, and a sensor array could provide a better indication of TCM pulse characteristics. In this study, the validation of the arrayed pulse wave analysis demonstrates that the APV can reliably mirror TCM pulse characteristics.


  • Open Access

    Study on the syndrome characteristics and classification model of non-small cell lung cancer based on tongue and pulse data (Preprint)

    by Yulin Shi, Jiayi Liu, Xiaojuan Hu, Liping Tu, Ji Cui, Jun Li, Zijuan Bi, Jiacai Li, Ling Xu, Jiatuo Xu

    BACKGROUND Lung cancer is a common malignant tumor that affects people's health seriously. Traditional Chinese medicine (TCM) is one of the effective methods for the treatment of advanced lung cancer, accurate TCM syndrome differentiation is essential to treatment. When the symptoms are not obvious, the traditional symptom-based syndrome differentiation cannot be carried out. There is a close relationship between syndrom and index of western medicine, the combination of micro index and macro symptom can assist syndrome differentiation effectively. OBJECTIVE To explore the characteristics of tongue and pulse data of non-small cell lung cancer (NSCLC) with Qi deficiency syndrome and Yin deficiency syndrome, and to establish syndromes classification model based on tongue and pulse data by using machine learning method, and to evaluate the feasibility of the model. METHODS Tongue and pulse data of non-small cell lung cancer (NSCLC) patients with Qi deficiency syndrome (n=163), patients with Yin deficiency syndrome (n=174) and healthy controls (n=185) were collected by using intelligent Tongue and Face Diagnosis Analysis-1 instrument and Pulse Diagnosis Analysis-1 instrument, respectively. The characteristics of tongue and pulse data were analyzed, the correlation analysis was also made on tongue and pulse data. And four machine learning methods, namely Random Forest, Logistic Regression, Support Vector Machine and Neural Network, were used to establish the classification models based on symptoms, tongue & pulse data, and symptoms & tongue & pulse data, respectively. RESULTS Significant difference indexes of tongue diagnosis between Qi deficiency syndrome and Yin deficiency syndrome were TB-a, TB-S, TB-Cr, TC-a, TC-S, TC-Cr, perAll and the tongue coating texture indexes including TC-Con, TC-ASM, TC-MEAN, and TC-ENT. Significant difference indexes of pulse diagnosis were t4 and t5. The classification performance of each model based on different data sets was as follows: model of tongue & pulse data <model of symptom < model of symptom & tongue & pulse data. The Neural Network model had a better classification performance for the symptom & tongue & pulse data, with an area under the ROC curve and accuracy rate were 0.9401 and 0.8806. CONCLUSIONS This study explored the characteristics of tongue and pulse data of NSCLC with Qi deficiency syndrome and Yin deficiency syndrome, and established syndromes classification model. It was feasible to use tongue and pulse data as one of the objective diagnostic indexes in Qi deficiency syndrome and Yin deficiency syndrome of NSCLC. CLINICALTRIAL Trial registration number: ChiCTR1900026008; ChiCTR-IOR-15006502 Date of registration: Jun. 04th, 2015 URL of trial registry record: http://www.chictr.org.cn/showprojen.aspx?proj=11119; http://www.chictr.org.cn/edit.aspx?pid=38828&htm=4 (This is a retrospective registration)

  • Open Access

    Data Mining of Tongue and Pulse based on Tongue Diagnosis and Pulse Diagnosis Instruments:Evaluation of Machine-Learning Assisting Classification of Fatigue Subjects (Preprint)

    by Shi Yulin, Lan Fang, Yao Xinghua, Hu Xiaojuan, Cui Ji, Cui Longtao, Huang Jingbin, Ma Xuxiang, Jiang Tao, Li Jun, et al.

    BACKGROUND Fatigue is one of the most common subjective symptom,due to lack of objective diagnostic criteria ,it is often neglected,especially in the early stage of disease.It is very important to establish an objective evaluation method for diagnosis of disease fatigue and non-disease fatigue based on tongue and pulse data. Our research team has been engaged in the informatization and intelligentization research of TCM diagnosis technology for more than 30 years, we have been engaged in health evaluation and analysis of large clinical sample data for many years, and accumulated a certain amount of typical data,in this area of research, foundation of our work has outstanding advantages. OBJECTIVE The purposes of this study is to explore a new method for clinical diagnosis of fatigue, by analyzing the characteristic of objective tongue and pulse data of disease fatigue subjects and sub-health fatigue subjects, and establishing the diagnosis and classification models of sub-health fatigue and disease fatigue based on the tongue and pulse data. METHODS In this study,736 subjects were selected from the Physical Examination Center, and were divided into healthy control, sub-health fatigue group and disease fatigue group according to physical examination indexes and health status assessment criteria. TFDA-1 tongue diagnosis instrument and PDA-1 pulse diagnosis instrument independently developed were used to collect the tongue image and sphygmogram of the subjects. Multivariate statistical analysis methods were usded to analyze the tongue and pulse data distribution pattern of the fatigue subjects, and machine learning methods were used to establish the diagnostic classification models of fatigue. RESULTS The tongue feature TB-a,TB-b,TB-H,TB-S,TB-I,TB-Cb,TC-L,TC-H,TC-I,TC-Y,TC-Cr,TC-Cb,perAll and perPart were statistically significant different among three groups (P < 0.05, P < 0.01). The sphygmogram feature t1,t4,h5,W1,W2,W1/t and W2/t showed statistically significant differences among three groups (P < 0.05, P < 0.01). There was a canonical correlation between the tongue and pulse data in the disease fatigue group, and the correlation coefficient was 0.649 (P<0.05). Logistic Regression models showed good classification efficiency for data sets of " tongue ", " basic information "and "tongue + pulse + basic information". The area under ROC curve was 0.7352, 0.9089 and 0.9460, respectively. And the Neural Network models showed better classification efficiency for data sets of " pulse " and "tongue + pulse", the area under ROC curve was 0.7957 and 0.8293, respectively. Besides Logistic Regression and Neural Network, Random Forest and SVM also showed good classification results in the diagnosis models. And the classification efficiency of models based on different data sets had the following trends in the three groups: "tongue"models <"pulse" models <" tongue+pulse"models <" basic information"models <" tongue+pulse+basic information "models. CONCLUSIONS Sub-health fatigue and disease fatigue subjects had different tongue and pulse characteristic. Diagnosis and classification models can be established using basic information, tongue and pulse data to explore a new method for evaluating fatigue state.

  • Open Access

    A Study of Machine-Learning Classifiers for Hypertension Based on Radial Pulse Wave

    by Zhi-Yu Luo, Ji Cui, Xiao-Juan Hu, Li-Ping Tu, Hai-Dan Liu, Wen Jiao, Ling-Zhi Zeng, Cong-Cong Jing, Li-Jie Qiao, Xu-Xiang Ma, et al.

    Objective. In this study, machine learning was utilized to classify and predict pulse wave of hypertensive group and healthy group and assess the risk of hypertension by observing the dynamic change of the pulse wave and provide an objective reference for clinical application of pulse diagnosis in traditional Chinese medicine (TCM). Method. The basic information from 450 hypertensive cases and 479 healthy cases was collected by self-developed H20 questionnaires and pulse wave information was acquired by self-developed pulse diagnostic instrument (PDA-1). H20 questionnaires and pulse wave information were used as input variables to obtain different machine learning classification models of hypertension. This method was aimed at analyzing the influence of pulse wave on the accuracy and stability of machine learning model, as well as the feature contribution of hypertension model after removing noise by K-means. Result. Compared with the classification results before removing noise, the accuracy and the area under the curve (AUC) had been improved. The accuracy rates of AdaBoost, Gradient Boosting, and Random Forest (RF) were 86.41%, 86.41%, and 85.33%, respectively. AUC were 0.86, 0.86, and 0.85, respectively. The maximum accuracy of SVM increased from 79.57% to 83.15%, and the AUC stability increased from 0.79 to 0.83. In addition, the features of importance on traditional statistics and machine learning were consistent. After removing noise, the features with large changes were h1/t1, w1/t, t, w2, h2, t1, and t5 in AdaBoost and Gradient Boosting (top10). The common variables for machine learning and traditional statistics were h1/t1, h5, t, Ad, BMI, and t2. Conclusion. Pulse wave-based diagnostic method of hypertension has significant value in reference. In view of the feasibility of digital-pulse-wave diagnosis and dynamically evaluating hypertension, it provides the research direction and foundation for Chinese medicine in the dynamic evaluation of modern disease diagnosis and curative effect.