Luke Anthony Jardine
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Luke Anthony Jardine has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
- Mark William Davies
Neonatology; Royal Brisbane and Women's Hospital; Brisbane Australia
17 shared publications - Garry Dt Inglis
Department of Paediatrics & Child Health, The University of Queensland
4 shared publications - Judith Hough
Australian Catholic University
4 shared publications Garry Dt Inglis
Department of Paediatrics & Child Health, The University of Queensland; Grantley Stable Neonatal Unit, Royal Brisbane and Women's Hospital; Butterfield Street Herston Brisbane Queensland Australia 4029
3 shared publicationsDavid Cartwright
Royal Brisbane and Women’s Hospital
2 shared publicationsKimble Robert Dunster
Queensland University of Technology
2 shared publications
Latest Publications
- Open Access
- 23 October 2026
- Published by Springer Nature in Research Square
Concordance with CDC criteria and antibiotic prescribing for suspected ventilator-associated pneumonia in a neonatal intensive care unit: a retrospective audit
Background Ventilator-associated pneumonia (VAP) is difficult to diagnose in neonates because clinical, radiological and microbiological findings are non-specific and no universally accepted neonatal gold standard exists. Diagnostic uncertainty may contribute to avoidable antimicrobial exposure. Objective To determine the proportion of mechanically ventilated neonates treated for suspected VAP who met Centers for Disease Control and Prevention (CDC) criteria, and to describe antibiotic prescribing, clinical findings and post-treatment respiratory change. Methods A retrospective audit was conducted using records from 1 January 2016 to 1 May 2020. Neonates were eligible if they were mechanically ventilated for at least 48 hours and received antibiotics for a suspected lower respiratory tract infection. Recorded clinical, radiological and laboratory findings were assessed against CDC criteria for infants aged 1 year or younger. Antibiotic regimens, organisms identified and respiratory status following treatment were described. Results Forty neonates were included; 23 (57.5%) met the applied CDC criteria. Piperacillin-tazobactam was the most frequently prescribed regimen (20/40, 50.0%); 11 of these 20 cases met CDC criteria. Post-treatment respiratory information was available for 38 neonates, of whom 29 (76.3%) had reduced respiratory support requirements or improved oxygenation. Meeting CDC criteria was associated with documented added breath sounds, leukopenia or leukocytosis, and apnoea or tachypnoea. Conclusions Just over half of the neonates treated for suspected VAP met the CDC criteria, highlighting the challenges of diagnosing neonatal VAP. These findings suggest that diagnostic uncertainty remains a significant issue and may influence treatment decisions. More accurate diagnostic approaches are needed to support antimicrobial stewardship, optimise antibiotic use and minimise unnecessary antimicrobial exposure in neonates.
- 23 October 2026
- Published by Springer Nature in Research Square
Open AccessConcordance with CDC criteria and antibiotic prescribing for suspected ventilator-associated pneumonia in a neonatal intensive care unit: a retrospective audit
Background Ventilator-associated pneumonia (VAP) is difficult to diagnose in neonates because clinical, radiological and microbiological findings are non-specific and no universally accepted neonatal gold standard exists. Diagnostic uncertainty may contribute to avoidable antimicrobial exposure. Objective To determine the proportion of mechanically ventilated neonates treated for suspected VAP who met Centers for Disease Control and Prevention (CDC) criteria, and to describe antibiotic prescribing, clinical findings and post-treatment respiratory change. Methods A retrospective audit was conducted using records from 1 January 2016 to 1 May 2020. Neonates were eligible if they were mechanically ventilated for at least 48 hours and received antibiotics for a suspected lower respiratory tract infection. Recorded clinical, radiological and laboratory findings were assessed against CDC criteria for infants aged 1 year or younger. Antibiotic regimens, organisms identified and respiratory status following treatment were described. Results Forty neonates were included; 23 (57.5%) met the applied CDC criteria. Piperacillin-tazobactam was the most frequently prescribed regimen (20/40, 50.0%); 11 of these 20 cases met CDC criteria. Post-treatment respiratory information was available for 38 neonates, of whom 29 (76.3%) had reduced respiratory support requirements or improved oxygenation. Meeting CDC criteria was associated with documented added breath sounds, leukopenia or leukocytosis, and apnoea or tachypnoea. Conclusions Just over half of the neonates treated for suspected VAP met the CDC criteria, highlighting the challenges of diagnosing neonatal VAP. These findings suggest that diagnostic uncertainty remains a significant issue and may influence treatment decisions. More accurate diagnostic approaches are needed to support antimicrobial stewardship, optimise antibiotic use and minimise unnecessary antimicrobial exposure in neonates.
- 15 October 2026
- Published by Wiley in Pediatric Pulmonology
- Vol. 61 (10) , e71860
Effects of Gastroschisis Reduction on Pulmonary Function
Aim: Neonates who have gastroschisis may be at risk of a deterioration in their pulmonary function as the lesion is reduced. Electrical Impedance Tomography (EIT) is a non‐invasive tool that can be used to examine respiratory function. The aim of this study was to examine the effects of bowel reduction in gastroschisis on respiratory function. We hypothesized that as the gastroschisis was reduced, End‐Expiratory Lung Impedance (EELI) would also be reduced. Methods: A Sentec LuMon EIT monitor was used to measure End‐Expiratory Lung Impedance (EELI) pre and post bowel reduction. Results: Eight patients, four female and four male, with an average gestational age of 36 + 6 weeks, and average birth weight of 2710 g were studied. Of the six patients that received a primary reduction, there was an average decrease in EELI of 17% in the first 48 h post reduction. The two patients that received staged silo reduction also saw a drop in EELI over the course of their reductions. Five patients took more than 2 days for their pulmonary function to return to their prereduction baseline. Conclusion: This data are consistent with a decrease in lung function with bowel reduction in gastroschisis. It also adds to the growing body of evidence of the utility of EIT in neonatal research.
- 15 October 2026
- Published by Wiley in Pediatric Pulmonology
- Vol. 61 (10) , e71860
Effects of Gastroschisis Reduction on Pulmonary Function
Aim: Neonates who have gastroschisis may be at risk of a deterioration in their pulmonary function as the lesion is reduced. Electrical Impedance Tomography (EIT) is a non‐invasive tool that can be used to examine respiratory function. The aim of this study was to examine the effects of bowel reduction in gastroschisis on respiratory function. We hypothesized that as the gastroschisis was reduced, End‐Expiratory Lung Impedance (EELI) would also be reduced. Methods: A Sentec LuMon EIT monitor was used to measure End‐Expiratory Lung Impedance (EELI) pre and post bowel reduction. Results: Eight patients, four female and four male, with an average gestational age of 36 + 6 weeks, and average birth weight of 2710 g were studied. Of the six patients that received a primary reduction, there was an average decrease in EELI of 17% in the first 48 h post reduction. The two patients that received staged silo reduction also saw a drop in EELI over the course of their reductions. Five patients took more than 2 days for their pulmonary function to return to their prereduction baseline. Conclusion: This data are consistent with a decrease in lung function with bowel reduction in gastroschisis. It also adds to the growing body of evidence of the utility of EIT in neonatal research.
- Open Access
Video Laryngoscopes in Simulated Neonatal Intubation: Usability Study
Background/Objectives: Neonatal intubation is a complex procedure, often associated with low first-pass success rates and a high incidence of complications. Video laryngoscopes provide several advantages, including higher success rates, especially for novice clinicians, a magnified airway view that can be shared with supervisors, and the ability to record still or video images for debriefing and education. However, video laryngoscope devices vary, raising the possibility of differences in usability. Methods: The study used mixed methodology, including observations, semi-structured interviews, think-aloud techniques, high-fidelity simulations, function tests, and questionnaires to assess usability, defined by the clinician satisfaction, efficacy, and efficiency of six video laryngoscope devices; (1) C-MAC® with Miller blade, (2) GlideScope® CoreTM with Miller blade, (3) GlideScope® CoreTM with hyperangle LoPro blade, (4) Koala® Vision Ultra with Miller blade, (5) Koala® Handheld with Miller blade, and (6) Parker Neonatal with Miller blade. Clinician satisfaction was determined by the System Usability Scale (SUS), National Aeronautics and Space Administration Task Load Index (NASA-TLX), and clinician preference. Device efficacy was determined by first-pass success, number of attempts, and overall success. Efficiency was assessed by time to successful intubation and function test completion rates. Results: Neonatal video laryngoscopes varied considerably in design, impacting usability. All devices were deemed suitable for neonatal intubation, with the Koala® Handheld, C-MAC®, and GlideScope® Core TM Miller demonstrating the highest usability. Conclusions: This simulation-based study highlights substantial variability in neonatal video laryngoscope usability, indicating the need for further research into usability in the clinical setting.
Open AccessVideo Laryngoscopes in Simulated Neonatal Intubation: Usability Study
Background/Objectives: Neonatal intubation is a complex procedure, often associated with low first-pass success rates and a high incidence of complications. Video laryngoscopes provide several advantages, including higher success rates, especially for novice clinicians, a magnified airway view that can be shared with supervisors, and the ability to record still or video images for debriefing and education. However, video laryngoscope devices vary, raising the possibility of differences in usability. Methods: The study used mixed methodology, including observations, semi-structured interviews, think-aloud techniques, high-fidelity simulations, function tests, and questionnaires to assess usability, defined by the clinician satisfaction, efficacy, and efficiency of six video laryngoscope devices; (1) C-MAC® with Miller blade, (2) GlideScope® CoreTM with Miller blade, (3) GlideScope® CoreTM with hyperangle LoPro blade, (4) Koala® Vision Ultra with Miller blade, (5) Koala® Handheld with Miller blade, and (6) Parker Neonatal with Miller blade. Clinician satisfaction was determined by the System Usability Scale (SUS), National Aeronautics and Space Administration Task Load Index (NASA-TLX), and clinician preference. Device efficacy was determined by first-pass success, number of attempts, and overall success. Efficiency was assessed by time to successful intubation and function test completion rates. Results: Neonatal video laryngoscopes varied considerably in design, impacting usability. All devices were deemed suitable for neonatal intubation, with the Koala® Handheld, C-MAC®, and GlideScope® Core TM Miller demonstrating the highest usability. Conclusions: This simulation-based study highlights substantial variability in neonatal video laryngoscope usability, indicating the need for further research into usability in the clinical setting.
- Open Access
- 18 February 2022
- Published by Wiley
Perinatal antecedents of moderate and severe neonatal hypoxic ischemic encephalopathy: an Australian birth cohort study
Objective: The aim of this study was to investigate key antecedents of moderate and severe neonatal hypoxic ischemic encephalopathy (HIE) in a large contemporary Australian birth cohort. Design: A retrospective cohort study of all births meeting the inclusion criteria between 2016-2020. Setting: The Mater Mothers’ Hospital, Brisbane, Australia. This is a quarternary perinatal center and Australia’s largest maternity hospital. Population: All non-anomalous, singleton liveborn infants, >35+0 weeks gestation. Methods: Univariate and multivariate firth logistic regression were used to account for imbalanced frequency classes. Main outcome measure: Neonatal moderate and severe HIE. Results: Overall, 133/46041 (0.29%) infants were diagnosed with HIE, and 56 (0.12%) were diagnosed with moderate/severe HIE. Nulliparity, type 1 diabetes mellitus and maternal intensive care unit admission were associated with increased odds of moderate/severe HIE. Intrapartum risk factors included emergency cesarean birth, emergency cesarean for non-reassuring fetal status or failure to process, intrapartum hemorrhage, and an intrapartum sentinel event (shoulder dystocia, cord prolapse, uterine rupture, placental abruption). Neonatal risk factors included male sex, birth at late preterm gestation (35+0 – 36+6 weeks), Apgar score <4 at 5 minutes, severe respiratory distress requiring ventilatory support and severe acidosis at birth. Conclusions: This cohort study identified a series of potentially modifiable maternal and obstetric risk factors for HIE. Risk factors for HIE do not appear to have changed significantly despite recent advances in obstetric care. Key words: pregnancy, fetus, fetal distress, intrapartum hypoxia, hypoxic ischemic encephalopathy, cerebral palsy Funding source: The authors acknowledge research support by the Mater Foundation.
- 18 February 2022
- Published by Wiley
Open AccessPerinatal antecedents of moderate and severe neonatal hypoxic ischemic encephalopathy: an Australian birth cohort study
Objective: The aim of this study was to investigate key antecedents of moderate and severe neonatal hypoxic ischemic encephalopathy (HIE) in a large contemporary Australian birth cohort. Design: A retrospective cohort study of all births meeting the inclusion criteria between 2016-2020. Setting: The Mater Mothers’ Hospital, Brisbane, Australia. This is a quarternary perinatal center and Australia’s largest maternity hospital. Population: All non-anomalous, singleton liveborn infants, >35+0 weeks gestation. Methods: Univariate and multivariate firth logistic regression were used to account for imbalanced frequency classes. Main outcome measure: Neonatal moderate and severe HIE. Results: Overall, 133/46041 (0.29%) infants were diagnosed with HIE, and 56 (0.12%) were diagnosed with moderate/severe HIE. Nulliparity, type 1 diabetes mellitus and maternal intensive care unit admission were associated with increased odds of moderate/severe HIE. Intrapartum risk factors included emergency cesarean birth, emergency cesarean for non-reassuring fetal status or failure to process, intrapartum hemorrhage, and an intrapartum sentinel event (shoulder dystocia, cord prolapse, uterine rupture, placental abruption). Neonatal risk factors included male sex, birth at late preterm gestation (35+0 – 36+6 weeks), Apgar score <4 at 5 minutes, severe respiratory distress requiring ventilatory support and severe acidosis at birth. Conclusions: This cohort study identified a series of potentially modifiable maternal and obstetric risk factors for HIE. Risk factors for HIE do not appear to have changed significantly despite recent advances in obstetric care. Key words: pregnancy, fetus, fetal distress, intrapartum hypoxia, hypoxic ischemic encephalopathy, cerebral palsy Funding source: The authors acknowledge research support by the Mater Foundation.
- 1 November 2021
- Published by Elsevier in Australian Critical Care
- Vol. 34 (6) , 524-529
A quality appraisal using the AGREE II instrument of endotracheal tube suction guidelines in neonatal intensive care units
- 1 November 2021
- Published by Elsevier in Australian Critical Care
- Vol. 34 (6) , 524-529
A quality appraisal using the AGREE II instrument of endotracheal tube suction guidelines in neonatal intensive care units
- 27 August 2021
- Published by Wiley in Journal of Paediatrics and Child Health
- Vol. 58 (1) , 163-169
Decreasing delivery room intubations: A quality improvement project
Aim: The delivery room intubation rate for babies born less than 32 weeks postmenstrual age (PMA) at the Mater Mothers' Hospital in 2017 was 51%. Delivery room intubation of preterm infants may be associated with an increased risk of developing bronchopulmonary dysplasia. This quality improvement project aimed to decrease the rate of delivery room intubation for infants born less than 32 weeks PMA.Methods: A quality improvement process using the evidence‐based practice for improving quality framework and Plan‐Do‐Study‐Act cycles was undertaken from October 2018 to December 2019. Commencing bubble continuous positive airway pressure for initial resuscitation in the delivery room was the principal change idea.Results: The delivery room intubation rate for infants born less than 32 weeks PMA before the commencement of this project was 48% (cohort 1, n = 221). There was a significant decrease in the rate to 37.2% while the project was being conducted (cohort 2, n = 277) and a further significant reduction to 28.2% after introducing bubble continuous positive airway pressure in the delivery room (cohort 3, n = 202). There was a significant improvement in admission temperatures and a significant decrease in mortality rate between cohort 1 and cohort 2 but not between cohort 2 and cohort 3. There was no change in the rate of discharge home on oxygen between cohorts.Conclusions: This quality improvement project led to a significantly decreased delivery room intubation rate in infants born less than 32 weeks PMA. There was no evidence of any adverse outcomes with this approach.
- 27 August 2021
- Published by Wiley in Journal of Paediatrics and Child Health
- Vol. 58 (1) , 163-169
Decreasing delivery room intubations: A quality improvement project
Aim: The delivery room intubation rate for babies born less than 32 weeks postmenstrual age (PMA) at the Mater Mothers' Hospital in 2017 was 51%. Delivery room intubation of preterm infants may be associated with an increased risk of developing bronchopulmonary dysplasia. This quality improvement project aimed to decrease the rate of delivery room intubation for infants born less than 32 weeks PMA.Methods: A quality improvement process using the evidence‐based practice for improving quality framework and Plan‐Do‐Study‐Act cycles was undertaken from October 2018 to December 2019. Commencing bubble continuous positive airway pressure for initial resuscitation in the delivery room was the principal change idea.Results: The delivery room intubation rate for infants born less than 32 weeks PMA before the commencement of this project was 48% (cohort 1, n = 221). There was a significant decrease in the rate to 37.2% while the project was being conducted (cohort 2, n = 277) and a further significant reduction to 28.2% after introducing bubble continuous positive airway pressure in the delivery room (cohort 3, n = 202). There was a significant improvement in admission temperatures and a significant decrease in mortality rate between cohort 1 and cohort 2 but not between cohort 2 and cohort 3. There was no change in the rate of discharge home on oxygen between cohorts.Conclusions: This quality improvement project led to a significantly decreased delivery room intubation rate in infants born less than 32 weeks PMA. There was no evidence of any adverse outcomes with this approach.
- 5 September 2016
- Published by Wiley in Cochrane Clinical Answers
What are the benefits and harms of cooling in newborns with hypoxic ischemic encephalopathy?
- 5 September 2016
- Published by Wiley in Cochrane Clinical Answers
What are the benefits and harms of cooling in newborns with hypoxic ischemic encephalopathy?
- Open Access
- 4 March 2015
- Published by Springer Nature in BMC Pediatrics
- Vol. 15 (1) , 1-13
Prem Baby Triple P: a randomised controlled trial of enhanced parenting capacity to improve developmental outcomes in preterm infants
Very preterm birth (<32 weeks gestation) is associated with motor, cognitive, behavioural and educational problems in children and maternal depression and withdrawal. Early interventions that target parenting have the greatest potential to create sustained effects on child development and parental psychopathology. Triple P (Positive Parenting Program) has shown positive effects on child behaviour and adjustment, parenting practices and family functioning. Baby Triple P for Preterm infants, has been developed to target parents of very preterm infants. This study tests the effectiveness of Baby Triple P for Preterm infants in improving child and parent/couple outcomes at 24 months corrected age (CA). Families will be randomised to receive either Baby Triple P for Preterm infants or Care as Usual (CAU). Baby Triple P for Preterm infants involves 4 × 2 hr group sessions at the hospital plus 4 × 30 min telephone consultations soon after transfer (42 weeks C.A.). After discharge participants will be linked to community based Triple P and intervention maintenance up to 24 months C.A. Assessments will be: baseline, post-intervention (6 weeks C.A.), at 12 and 24 months C.A. The primary outcome measure is the Infant Toddler Social & Emotional Assessment (ITSEA) at 24 months C.A. Child behavioural and emotional problems will be coded using the mother-toddler version of the Family Observation Schedule at 24 months C.A. Secondary outcome will be the Bayley Scales of Infant and Toddler Development (BSID III) cognitive development, language and motor abilities. Proximal targets of parenting style, parental self-efficacy, parental mental health, parental adjustment, parent-infant attachment, couple relationship satisfaction and couple communication will also be assessed. Our sample size based on the ITSEA, has 80% power, predicted effect size of 0.33 and an 85% retention rate, requires 165 families are required in each group (total sample of 330 families). This protocol presents the study design, methods and intervention to be analysed in a randomised trial of Baby Triple P for Preterm infants compared to Care as Usual (CAU) for families of very preterm infants. Publications of all outcomes will be published in peer reviewed journals according to CONSORT guidelines. Australian New Zealand Clinical Trials Registry: ACTRN12612000194864 .
- 4 March 2015
- Published by Springer Nature in BMC Pediatrics
- Vol. 15 (1) , 1-13
Open AccessPrem Baby Triple P: a randomised controlled trial of enhanced parenting capacity to improve developmental outcomes in preterm infants
Very preterm birth (<32 weeks gestation) is associated with motor, cognitive, behavioural and educational problems in children and maternal depression and withdrawal. Early interventions that target parenting have the greatest potential to create sustained effects on child development and parental psychopathology. Triple P (Positive Parenting Program) has shown positive effects on child behaviour and adjustment, parenting practices and family functioning. Baby Triple P for Preterm infants, has been developed to target parents of very preterm infants. This study tests the effectiveness of Baby Triple P for Preterm infants in improving child and parent/couple outcomes at 24 months corrected age (CA). Families will be randomised to receive either Baby Triple P for Preterm infants or Care as Usual (CAU). Baby Triple P for Preterm infants involves 4 × 2 hr group sessions at the hospital plus 4 × 30 min telephone consultations soon after transfer (42 weeks C.A.). After discharge participants will be linked to community based Triple P and intervention maintenance up to 24 months C.A. Assessments will be: baseline, post-intervention (6 weeks C.A.), at 12 and 24 months C.A. The primary outcome measure is the Infant Toddler Social & Emotional Assessment (ITSEA) at 24 months C.A. Child behavioural and emotional problems will be coded using the mother-toddler version of the Family Observation Schedule at 24 months C.A. Secondary outcome will be the Bayley Scales of Infant and Toddler Development (BSID III) cognitive development, language and motor abilities. Proximal targets of parenting style, parental self-efficacy, parental mental health, parental adjustment, parent-infant attachment, couple relationship satisfaction and couple communication will also be assessed. Our sample size based on the ITSEA, has 80% power, predicted effect size of 0.33 and an 85% retention rate, requires 165 families are required in each group (total sample of 330 families). This protocol presents the study design, methods and intervention to be analysed in a randomised trial of Baby Triple P for Preterm infants compared to Care as Usual (CAU) for families of very preterm infants. Publications of all outcomes will be published in peer reviewed journals according to CONSORT guidelines. Australian New Zealand Clinical Trials Registry: ACTRN12612000194864 .