Bradley A. Reinholz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bradley A. Reinholz has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Rudolf J. Seethaler
Department of School of Engineering, The University of British Columbia, Kelowna, Canada
3 shared publications- Taco Niet
Simon Fraser University
2 shared publications - Devin K. Reinholz
School of Engineering, University of British Columbia, Kelowna, Canada
1 shared publication - Gustavo L. Aschidamini
School of Sustainable Energy Engineering, Faculty of Applied Sciences, Simon Fraser University, Surrey Campus, Surrey, BC, Canada
1 shared publication Kamran Tehranchi
1 shared publicationMalcolm Metcalfe
1 shared publication
Latest Publications
- Open Access
- 8 May 2026
- Published by Public Library of Science (PLoS) in PLOS Climate
- Vol. 5 (5) , e0000918
Multi-sector demand response for cost optimal energy transitions
Demand response is consistently highlighted as an important solution in electricity planning literature to help reduce costs throughout the energy transition. We build on these results and investigate how demand response performs in multi-sector energy planning studies. We implement two different demand response pricing strategies, one that is energy carrier independent and one that is energy carrier specific, and apply it to the open-source PyPSA-USA energy system optimization model. A case study of California and New England is performed for a future 2030 energy system. System-level metrics and net-load characteristics are analyzed. The results show that both electrical and thermal demand response offer cost savings in capacity constrained systems by acting as a flexible resource. Moreover, pricing demand response separately for each energy carrier and energy sector is most effective in reducing system costs. Finally, thermal demand response significantly reduces service sector space heating capacity, providing investment cost savings. A sensitivity analysis indicates that significant cost savings can be achieved with minimal demand response adoption. We conclude by highlighting how the pricing strategy implemented favours short-term load shifting and discuss where applying this method is appropriate.
- 8 May 2026
- Published by Public Library of Science (PLoS) in PLOS Climate
- Vol. 5 (5) , e0000918
Open AccessMulti-sector demand response for cost optimal energy transitions
Demand response is consistently highlighted as an important solution in electricity planning literature to help reduce costs throughout the energy transition. We build on these results and investigate how demand response performs in multi-sector energy planning studies. We implement two different demand response pricing strategies, one that is energy carrier independent and one that is energy carrier specific, and apply it to the open-source PyPSA-USA energy system optimization model. A case study of California and New England is performed for a future 2030 energy system. System-level metrics and net-load characteristics are analyzed. The results show that both electrical and thermal demand response offer cost savings in capacity constrained systems by acting as a flexible resource. Moreover, pricing demand response separately for each energy carrier and energy sector is most effective in reducing system costs. Finally, thermal demand response significantly reduces service sector space heating capacity, providing investment cost savings. A sensitivity analysis indicates that significant cost savings can be achieved with minimal demand response adoption. We conclude by highlighting how the pricing strategy implemented favours short-term load shifting and discuss where applying this method is appropriate.
- Open Access
- 13 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 85927-85950
Comprehensive Review on the Control of Heat Pumps for Energy Flexibility in Distribution Networks
Decarbonization plans promote the transition to heat pumps (HPs), creating new opportunities for their energy flexibility in demand response programs, solar photovoltaic integration, and optimization of distribution networks. This paper reviews scheduling-based and real-time optimization methods for controlling HPs with a focus on energy flexibility in distribution networks. Scheduling-based methods fall into two categories: rule-based controllers (RBCs), which rely on predefined control rules without explicitly seeking optimal solutions, and optimization models, which are designed to determine the optimal scheduling of operations. Real-time optimization is achieved through model predictive control (MPC), which relies on a predictive model to optimize decisions over a time horizon, and reinforcement learning (RL), which takes a model-free approach by learning optimal strategies through direct interaction with the environment. The paper also examines studies on the impact of HPs on distribution networks, particularly those leveraging energy flexibility strategies. Key takeaways suggest the need to validate control strategies for extreme cold-weather regions that require backup heaters, as well as develop approaches designed for demand charge schemes that integrate HPs with other controllable loads. From a grid impact assessment perspective, studies have focused primarily on RBCs for providing energy flexibility through HP operation, without addressing more advanced methods such as real-time optimization using MPC or RL-based algorithms. Incorporating these advanced control strategies could help identify key limitations, including the impact of varying user participation levels and the cost-benefit trade-offs associated with their implementation.
- 13 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 85927-85950
Open AccessComprehensive Review on the Control of Heat Pumps for Energy Flexibility in Distribution Networks
Decarbonization plans promote the transition to heat pumps (HPs), creating new opportunities for their energy flexibility in demand response programs, solar photovoltaic integration, and optimization of distribution networks. This paper reviews scheduling-based and real-time optimization methods for controlling HPs with a focus on energy flexibility in distribution networks. Scheduling-based methods fall into two categories: rule-based controllers (RBCs), which rely on predefined control rules without explicitly seeking optimal solutions, and optimization models, which are designed to determine the optimal scheduling of operations. Real-time optimization is achieved through model predictive control (MPC), which relies on a predictive model to optimize decisions over a time horizon, and reinforcement learning (RL), which takes a model-free approach by learning optimal strategies through direct interaction with the environment. The paper also examines studies on the impact of HPs on distribution networks, particularly those leveraging energy flexibility strategies. Key takeaways suggest the need to validate control strategies for extreme cold-weather regions that require backup heaters, as well as develop approaches designed for demand charge schemes that integrate HPs with other controllable loads. From a grid impact assessment perspective, studies have focused primarily on RBCs for providing energy flexibility through HP operation, without addressing more advanced methods such as real-time optimization using MPC or RL-based algorithms. Incorporating these advanced control strategies could help identify key limitations, including the impact of varying user participation levels and the cost-benefit trade-offs associated with their implementation.
- 27 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (24) , 23997-24005
Sensor Fusion of Self-Sensed Measurements for Position Control of a Constant Air-Gap Solenoid
This paper presents a novel constant air gap solenoid (CAS) actuator design that can perform accurate and wide-bandwidth closed-loop position control with two fused self-sensed plunger measurements. The recently-patented CAS actuator is experimentally validated to be the first electromagnetic actuator with the ability to simultaneously produce two plunger position measurements with complementary bandwidth characteristics. First, a variable reluctance differential solenoid transducer is converted into a stacked CAS actuator through minor geometry modifications. Next, two complementary self-sensing methods that are based on inductance and back electromotive force (BEMF) are selected. Then, a complementary filter design is proposed to fuse the inductance-based and BEMF-based self-sensing methods. Afterwards, the design and fabrication of the prototype CAS actuator and the experimental setup are discussed. The experimental setup is then used to characterize the prototype CAS actuator and observe the performance of the individual self-sensing methods. Finally, the fused measurement is used for feedback in closed-loop position control. The closed-loop position control experiments show the self-sensed feedback performs comparably with a dedicated high-end laser vibrometer. Furthermore, the results show the sensor fusion output performs better than the individual self-sensing methods.
- 27 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (24) , 23997-24005
Sensor Fusion of Self-Sensed Measurements for Position Control of a Constant Air-Gap Solenoid
This paper presents a novel constant air gap solenoid (CAS) actuator design that can perform accurate and wide-bandwidth closed-loop position control with two fused self-sensed plunger measurements. The recently-patented CAS actuator is experimentally validated to be the first electromagnetic actuator with the ability to simultaneously produce two plunger position measurements with complementary bandwidth characteristics. First, a variable reluctance differential solenoid transducer is converted into a stacked CAS actuator through minor geometry modifications. Next, two complementary self-sensing methods that are based on inductance and back electromotive force (BEMF) are selected. Then, a complementary filter design is proposed to fuse the inductance-based and BEMF-based self-sensing methods. Afterwards, the design and fabrication of the prototype CAS actuator and the experimental setup are discussed. The experimental setup is then used to characterize the prototype CAS actuator and observe the performance of the individual self-sensing methods. Finally, the fused measurement is used for feedback in closed-loop position control. The closed-loop position control experiments show the self-sensed feedback performs comparably with a dedicated high-end laser vibrometer. Furthermore, the results show the sensor fusion output performs better than the individual self-sensing methods.
- 14 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (22) , 21585-21591
Design and Validation of a Variable Reluctance Differential Solenoid Transducer With an Ironless Stator
This article presents the design methodology, simulation results, and experimental results of a novel variable reluctance differential solenoid transducer (VRDST). The new ironless-stator VRDST (ISVRDST) is designed to mitigate the practical challenges inherent in the VRDST while maintaining its beneficial features compared to other linear inductive differential position sensors. The ISVRDST uses an air stator to reduce cost and increase compactness. FEA and Simulink simulations are used to predict the performance of the ISVRDST and a proof-of-concept prototype is designed to experimentally validate the simulation results. Like the VRDST, the ISVRDST is designed to utilize a complementary filter to fuse a low-speed position measurement with a high-speed velocity measurement, resulting in a single wide-bandwidth position measurement. The experimental results of the prototype ISVRDST prove that it is capable of robustly performing and fusing the two measurements utilized by the VRDST. In addition, the analytically predicted error of the fused measurement is found to be less than 1% different than the actual error relative to a high-precision laser vibrometer. When compared to the VRDST, the ISVRDST prototype is found to have a stroke-to-length ratio that is nearly four times greater and a cost that is over 100 times lower.
- 14 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (22) , 21585-21591
Design and Validation of a Variable Reluctance Differential Solenoid Transducer With an Ironless Stator
This article presents the design methodology, simulation results, and experimental results of a novel variable reluctance differential solenoid transducer (VRDST). The new ironless-stator VRDST (ISVRDST) is designed to mitigate the practical challenges inherent in the VRDST while maintaining its beneficial features compared to other linear inductive differential position sensors. The ISVRDST uses an air stator to reduce cost and increase compactness. FEA and Simulink simulations are used to predict the performance of the ISVRDST and a proof-of-concept prototype is designed to experimentally validate the simulation results. Like the VRDST, the ISVRDST is designed to utilize a complementary filter to fuse a low-speed position measurement with a high-speed velocity measurement, resulting in a single wide-bandwidth position measurement. The experimental results of the prototype ISVRDST prove that it is capable of robustly performing and fusing the two measurements utilized by the VRDST. In addition, the analytically predicted error of the fused measurement is found to be less than 1% different than the actual error relative to a high-precision laser vibrometer. When compared to the VRDST, the ISVRDST prototype is found to have a stroke-to-length ratio that is nearly four times greater and a cost that is over 100 times lower.
- 9 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (23) , 11063-11071
Design and Validation of a Variable Reluctance Differential Solenoid Transducer
This paper presents a novel variable reluctance differential solenoid transducer (VRDST) that offers improved high-speed sensing performance over linear voltage differential transformers (LVDTs) and differential variable reluctance transformers (DVRTs). The VRDST has the unique ability to measure both position and velocity simultaneously using two independent measurements. This paper investigates a basic geometry for a VRDST. The position and velocity measurement methods are derived and implemented in a Simulink simulation. The simulated VRDST model is augmented with an FEA simulation to predict the magnetic characteristics of the investigated design. The results and predictions established by the simulation and analytical models are validated experimentally with a physical prototype. The similarity between the experimental and simulated results suggest the proposed FEA and Simulink simulations can be used to accurately predict the performance of a physical VRDST. The findings from the analytical modeling, simulation study and experimental validation all unanimously prove the position measurement performs well when measuring low-speed displacements, while the integrated-velocity measurement is useful for measuring high-speed displacements. The differing frequency ranges of these two independent measurements are found to complement each other and suggest the VRDST is superior compared to DVRTs or LVDTs for applications requiring wide bandwidth position measurements.
- 9 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (23) , 11063-11071
Design and Validation of a Variable Reluctance Differential Solenoid Transducer
This paper presents a novel variable reluctance differential solenoid transducer (VRDST) that offers improved high-speed sensing performance over linear voltage differential transformers (LVDTs) and differential variable reluctance transformers (DVRTs). The VRDST has the unique ability to measure both position and velocity simultaneously using two independent measurements. This paper investigates a basic geometry for a VRDST. The position and velocity measurement methods are derived and implemented in a Simulink simulation. The simulated VRDST model is augmented with an FEA simulation to predict the magnetic characteristics of the investigated design. The results and predictions established by the simulation and analytical models are validated experimentally with a physical prototype. The similarity between the experimental and simulated results suggest the proposed FEA and Simulink simulations can be used to accurately predict the performance of a physical VRDST. The findings from the analytical modeling, simulation study and experimental validation all unanimously prove the position measurement performs well when measuring low-speed displacements, while the integrated-velocity measurement is useful for measuring high-speed displacements. The differing frequency ranges of these two independent measurements are found to complement each other and suggest the VRDST is superior compared to DVRTs or LVDTs for applications requiring wide bandwidth position measurements.