KTKerim Ture

Kerim Ture

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kerim Ture has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An Implantable Wireless System for Remote Hemodynamic Monitoring of Heart Failure Patients

    by Mustafa Besirli, Kerim Ture, Maurice Beghetti, Franco Maloberti, Catherine Dehollain, Marco Mattavelli, Diego Barrettino

    This paper presents an implantable wireless system for remote hemodynamic monitoring, which enables direct, continuous (24/7), and simultaneous measurement of pulmonary arterial pressure (PAP) and cross-sectional area (CSA) of the artery. The implantable device, which measures 3.2 mm × 2 mm × 10 mm, comprises a piezoresistive pressure sensor, an ASIC implemented in 180-nm CMOS, a piezoelectric ultrasound (US) transducer, and a nitinol anchoring loop. An energy-efficient pressure monitoring system, which employs duty-cycling and spinning excitation technique, achieves 0.44 mmHg resolution in a pressure range from –135 mmHg to +135 mmHg and consumes 1.1 nJ conversion energy. The artery diameter monitoring system utilizes the inductive characteristic of the implant's anchoring loop and achieves 0.24 mm resolution within a diameter range of 20 mm to 30 mm, four times higher than echocardiography lateral resolution. The wireless US power and data platform enables simultaneous power and data transfer employing a single piezoelectric transducer in the implant. The system is characterized with an 8.5 cm tissue phantom and achieves a US link efficiency of 1.8%. The uplink data is transmitted by using an ASK modulation scheme parallel to the power transfer and achieves a modulation index of 26%. The implantable system is tested in an in-vitro experimental setup, which emulates the arterial blood flow, and accurately detects fast pressure peaks for systolic and diastolic pressure changes at both 1.28 MHz and 1.6 MHz US powering frequencies, with corresponding uplink data rates of 40 kbps and 50 kbps.


  • Open Access

    An Energy-Efficient Bridge-to-Digital Converter for Implantable Pressure Monitoring Systems

    by Mustafa Besirli, Kerim Ture, Maurice Beghetti, Catherine Dehollain, Marco Mattavelli, Franco Maloberti, Diego Barrettino

    This paper presents an energy-efficient, duty-cycled, and spinning excitation bridge-to-digital converter (BDC) designed for implantable pressure sensing systems. The circuit provides the measure of the pulmonary artery pressure that is particularly relevant for the monitoring of heart failure and pulmonary hypertension patients. The BDC is made of a piezoresistive pressure sensor and a readout integrated circuit (IC) that comprises an instrumentation amplifier (IA) followed by an analog-to-digital converter (ADC). The proposed design spins both the bridge excitation and the ADC’s sampling input voltages simultaneously and exploits duty cycling to reduce the static power consumption of the bridge sensor and IA while cancelling the IA’s offset and 1/f noise at the same time. The readout IC has been designed and fabricated in a standard 180-nm CMOS process and achieves 8.4 effective number of bits (ENOB) at 1 kHz sampling rate while drawing 0.53 µA current from a 1.2 V supply. The BDC, built with the readout IC and a differential pressure sensor having 5 k$\Omega$ bridge resistances, achieves 0.44 mmHg resolution in a 270 mmHg pressure range at 1 ms conversion time. The current consumption of the bridge sensor by employing duty cycling is reduced by 99.8% thus becoming 0.39 µA from a 1.2 V supply. The total conversion energy of the pressure sensing system is 1.1 nJ, and achieves a figure-of-merit (FoM) of 3.3 pJ/conversion, which both represent the state of the art.


  • A 16-Channel Neural Recording System-on-Chip With CHT Feature Extraction Processor in 65-nm CMOS

    by Arda Uran, Kerim Ture, Cosimo Aprile, Alix Trouillet, Florian Fallegger, Emilie C. M. Revol, Azita Emami, Stephanie P. Lacour, Catherine Dehollain, Yusuf Leblebici, et al.

    Next-generation invasive neural interfaces require fully implantable wireless systems that can record from a large number of channels simultaneously. However, transferring the recorded data from the implant to an external receiver emerges as a significant challenge due to the high throughput. To address this challenge, this article presents a neural recording system-on-chip that achieves high resource and wireless bandwidth efficiency by employing on-chip feature extraction. Energy–area-efficient 10-bit 20-kS/s front end amplifies and digitizes the neural signals within the local field potential (LFP) and action potential (AP) bands. The raw data from each channel are decomposed into spectral features using a compressed Hadamard transform (CHT) processor. The selection of the features to be computed is tailored through a machine learning algorithm such that the overall data rate is reduced by 80% without compromising classification performance. Moreover, the CHT feature extractor allows waveform reconstruction on the receiver side for monitoring or additional post-processing. The proposed approach was validated through in vivo and off-line experiments. The prototype fabricated in 65-nm CMOS also includes wireless power and data receiver blocks to demonstrate the energy and area efficiency of the complete system. The overall signal chain consumes 2.6 $\mu \text{W}$ and occupies 0.021 mm 2 per channel, pointing toward its feasibility for 1000-channel single-die neural recording systems.


  • Adaptive Learning-Based Compressive Sampling for Low-power Wireless Implants

    by Cosimo Aprile, Kerim Ture, Luca Baldassarre, Mahsa Shoaran, Gurkan Yilmaz, Franco Maloberti, Catherine Dehollain, Yusuf Leblebici, Volkan Cevher

    Implantable systems are nowadays being used to interface the human brain with external devices, in order to understand and potentially treat neurological disorders. The most predominant design constraints are the system's area and power. In this paper, we implement and combine advanced compressive sampling algorithms to reduce the power requirements of wireless telemetry. Moreover, we apply variable compression, to dynamically modify the device performance, based on the actual signal need. This paper presents an area-efficient adaptive system for wireless implantable devices, which dynamically reduces the power requirements yielding compression rates from 8x to 64x, with a high reconstruction performance, as qualitatively demonstrated on a human data set. Two different versions of the encoder have been designed and tested, one with and the second without the adaptive compression, requiring an area of 230x235 μm and 200x190 μm, respectively, while consuming only 0.47 μW at 0.8 V. The system is powered by a 4-coil inductive link with measured power transmission efficiency of 36%, while the distance between the external and internal coils is 10 mm. Wireless data communication is established by an OOK modulated narrowband and an IR-UWB transmitter, while consuming 124.2 pJ/bit and 45.2 pJ/pulse, respectively.


  • Area and Power Efficient Ultra-Wideband Transmitter Based on Active Inductor

    by Kerim Ture, Arnout Devos, Franco Maloberti, Catherine Dehollain

    The paper presents the design of an impulse radio ultra-wideband (IR-UWB) transmitter for low-power, short-range, and high-data rate applications such as high density neural recording interfaces. The IR-UWB transmitter pulses are generated by modulating the output of a local oscillator. The large area requirement of the spiral inductor in a conventional on-chip LC tank is overcome by replacing it with an active inductor topology. The circuit has been fabricated in a UMC CMOS 180 nm technology, with a die area of 0.021 mm2. The temporal width of the output waveform is determined by a pulse generator based on logic gates. The measured pulse is compliant with Federal Communications Commission (FCC) power spectral density limits and within the frequency band of 3-6 GHz. For the minimum pulse duration of 1 ns, the energy consumption of the design is 20 pJ per bit, while transmitting at 200 Mbps data rate with an amplitude of 130 mV.


  • Optimization of the data rate of an OOK CMOS medical transmitter based on LC oscillators

    by Kerim Ture, Gurkan Yilmaz, Franco Maloberti, Catherine Dehollain

    This paper presents techniques for increasing communication data rates for OOK modulated signals in the case the carrier frequency is generated by a cross-coupled pair LC oscillator. The proposed circuitry completely turns off the transmitter during the transmission of “0” bit and oscillation occurs only when the data bit is “1” to reduce power consumption. The data bit controls the steady state bias current and the operation of the oscillator. The communication data rate is limited by the turn-on and turn-off time of the LC oscillator. In order to speed up the turn-on time of the oscillator, in addition to bias current, an extra current source is used during the build-up of the oscillator. The decay time of the oscillator when the data is switched from “1” to “0” is accelerated by shortening the inductor connections. The concept is demonstrated through the design of an LC VCO in 0.18 μm CMOS technology. The LC oscillator is designed to oscillate in MedRadio band at 416 MHz frequency. Simulation results show that the proposed architecture shortens the turn-on time from 86.5 ns to 24 ns and the turn-off time from 101 ns to 5.93 ns. With the additional techniques, the maximum achievable communication data rate is increased by more than 6 times.


  • Remotely powered PPM demodulator by inductive coupling for rodent applications

    by Kerim Ture, Enver G. Kilinc, Franco Maloberti, Catherine Dehollain


  • A fully integrated low-power class-E power amplifier for short range communication

    by Kerim Ture, Enver G. Kilinc, Catherine Dehollain

    This paper presents the advantages and drawbacks of designing different power amplifier types. The study also compares the drain efficiencies of the current-source and switch-type power amplifiers. The appropriate power amplifier needs to be chosen for low-power short range data communication. A fully integrated low-power class-E power amplifier at 869 MHz for short range communication is designed. The power amplifier is integrated using a 0.18 μm CMOS technology. Post-layout simulation results show the effectiveness of the power amplifier. The power amplifier consumes only 487.2 μW at 0.2 V supply voltage. The drain efficiency of the power amplifier is 55% at -5.8 dBm output power for 50 Ω load.