Liming Fan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Liming Fan has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Chong Kang
2 shared publications- Chong Kang
Harbin Engineering University
2 shared publications Hao Hu
Qingdao Research Institute, Northwestern Polytechnical University, Qingdao 266200, China
2 shared publicationsHuigang Wang
Qingdao Research Institute, Northwestern Polytechnical University, Qingdao 266200, China
2 shared publicationsXiaojun Zhang
2 shared publicationsJianguo Liu
1 shared publication
Latest Publications
- Open Access
- 28 August 2020
- Published by Wiley in Journal of Sensors
- Vol. 2020, 1-10
Adaptive Magnetic Anomaly Detection Method with Ensemble Empirical Mode Decomposition and Minimum Entropy Feature
Due to the fast attenuation of the magnetic field along with the distance, the magnetic anomaly generated by the remote magnetic target is usually buried in the magnetic noise. In order to improve the performance of magnetic anomaly detection (MAD) with low SNR, we propose an adaptive method of MAD with ensemble empirical mode decomposition (EEMD) and minimum entropy (ME) feature. The magnetic data is decomposed into the multiple intrinsic modal functions (IMFs) with different scales by EEMD. According to a defined criterion, the magnetic noise and magnetic signal are reconstructed based on IMFs, respectively. Entropy feature of reconstructed magnetic signal is extracted based on the probability density function (PDF) of the noise which is updated by the reconstructed magnetic noise. Compared to the traditional minimum entropy method, the entropy feature extracted by the proposed method is more obvious. The magnetic anomaly is detected whenever the entropy feature drops below the threshold. Thus, it is effective for revealing the weak magnetic anomaly by the proposed method. The measured magnetic noise is used to validate the performance of the proposed method. The results show that the detection probability of the proposed method is higher with low input SNR.
- 28 August 2020
- Published by Wiley in Journal of Sensors
- Vol. 2020, 1-10
Open AccessAdaptive Magnetic Anomaly Detection Method with Ensemble Empirical Mode Decomposition and Minimum Entropy Feature
Due to the fast attenuation of the magnetic field along with the distance, the magnetic anomaly generated by the remote magnetic target is usually buried in the magnetic noise. In order to improve the performance of magnetic anomaly detection (MAD) with low SNR, we propose an adaptive method of MAD with ensemble empirical mode decomposition (EEMD) and minimum entropy (ME) feature. The magnetic data is decomposed into the multiple intrinsic modal functions (IMFs) with different scales by EEMD. According to a defined criterion, the magnetic noise and magnetic signal are reconstructed based on IMFs, respectively. Entropy feature of reconstructed magnetic signal is extracted based on the probability density function (PDF) of the noise which is updated by the reconstructed magnetic noise. Compared to the traditional minimum entropy method, the entropy feature extracted by the proposed method is more obvious. The magnetic anomaly is detected whenever the entropy feature drops below the threshold. Thus, it is effective for revealing the weak magnetic anomaly by the proposed method. The measured magnetic noise is used to validate the performance of the proposed method. The results show that the detection probability of the proposed method is higher with low input SNR.
- 26 August 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (11) , 115105
Gradient signals analysis of scalar magnetic anomaly using orthonormal basis functions
Magnetic anomaly detection is a passive and effective approach for detecting magnetic targets. During detection using one scalar magnetometer, temporal magnetic variations will affect the detection performance. In order to reduce the influence of magnetic variations on detection, we focus on the analysis of magnetic gradient signals and obtain four orthonormal basis functions (OBFs) of gradient signal. Based on the set of OBFs, we propose an improved method using the magnetic gradient signal. Meanwhile, we can also obtain the bearing of the target relative to the survey line in the method. The proposed method is validated by simulation and real-world magnetic noise. The results show that the proposed method has a good detection performance with low signal to noise ratio. Therefore, the proposed method can improve the detection probability of weak magnetic anomalies and also determine the bearing of targets relative to the survey line.
- 26 August 2020
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (11) , 115105
Gradient signals analysis of scalar magnetic anomaly using orthonormal basis functions
Magnetic anomaly detection is a passive and effective approach for detecting magnetic targets. During detection using one scalar magnetometer, temporal magnetic variations will affect the detection performance. In order to reduce the influence of magnetic variations on detection, we focus on the analysis of magnetic gradient signals and obtain four orthonormal basis functions (OBFs) of gradient signal. Based on the set of OBFs, we propose an improved method using the magnetic gradient signal. Meanwhile, we can also obtain the bearing of the target relative to the survey line in the method. The proposed method is validated by simulation and real-world magnetic noise. The results show that the proposed method has a good detection performance with low signal to noise ratio. Therefore, the proposed method can improve the detection probability of weak magnetic anomalies and also determine the bearing of targets relative to the survey line.
- Open Access
- 22 April 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 1-10
An efficient method for tracking a magnetic target using scalar magnetometer array
The position of a magnetic target can be obtained through magnetic anomaly which is measured by a magnetic sensor. Comparing with vector magnetic sensor, the measurement value of the scalar magnetic sensor is almost not influenced by its orientation in measurement coordinate axes. Therefore, scalar magnetic sensors can be easily assembled into an array. Based on analysis of the total scalar magnetic anomaly measured by scalar magnetometer, we present an efficient method for tracking a magnetic target using scalar magnetometer array. In this method, we separate the position information and magnetic moment information of magnetic target by matrix transformation. Then, we can obtain the position of the magnetic target in real time by a scalar magnetometer array and a particle swarm optimization algorithm. In addition, the magnetic moment of the target can be estimated when the target’s position had been calculated. The simulation shows that the position of the target can be calculated accurately and the relative error of the position is <5 %. The calculated magnetic moment of the target is close to the theoretical value. In addition, execution time of each calculation is <1 s. Thus, the position of the magnetic target can be obtained in real-time through this method.
- 22 April 2016
- Published by Springer Nature in SpringerPlus
- Vol. 5 (1) , 1-10
Open AccessAn efficient method for tracking a magnetic target using scalar magnetometer array
The position of a magnetic target can be obtained through magnetic anomaly which is measured by a magnetic sensor. Comparing with vector magnetic sensor, the measurement value of the scalar magnetic sensor is almost not influenced by its orientation in measurement coordinate axes. Therefore, scalar magnetic sensors can be easily assembled into an array. Based on analysis of the total scalar magnetic anomaly measured by scalar magnetometer, we present an efficient method for tracking a magnetic target using scalar magnetometer array. In this method, we separate the position information and magnetic moment information of magnetic target by matrix transformation. Then, we can obtain the position of the magnetic target in real time by a scalar magnetometer array and a particle swarm optimization algorithm. In addition, the magnetic moment of the target can be estimated when the target’s position had been calculated. The simulation shows that the position of the target can be calculated accurately and the relative error of the position is <5 %. The calculated magnetic moment of the target is close to the theoretical value. In addition, execution time of each calculation is <1 s. Thus, the position of the magnetic target can be obtained in real-time through this method.
- 29 January 2016
- Published by Springer Nature in Pure and Applied Geophysics
- Vol. 173 (6) , 2065-2071
Real-Time Tracking Method for a Magnetic Target Using Total Geomagnetic Field Intensity
- 29 January 2016
- Published by Springer Nature in Pure and Applied Geophysics
- Vol. 173 (6) , 2065-2071
Real-Time Tracking Method for a Magnetic Target Using Total Geomagnetic Field Intensity