Al-Rafidain Engineering Journal (AREJ)
Published by University of Mosul
- Scopus
- Scilit
- DOAJ
- Power Systems & Electric Vehicles
- Telecommunications
- Concrete
- Energy Systems & Technologies
- Climate Change
- Water Resources
- Asphalt
Publications Analysis
Publications in 2016-2026
Open Access Publications in 2016-2026
- Total Citations
- 80
- Total Publications
- 139
- Average Citations
- 0.58
- Cited Publications
- 48
- Cited Publications %
- 34.5%
- Self Citations
- 10
- Self Citations %
- 12.5%
- Q1
- 0
- Med
- 1
- Q3
- 2
- 99%
- 11.1
- Max
- 14
- Citing Source Titles
- Citing Publishers
Latest Publications
- Open Access
- 1 September 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (3) , 72-83
LR-Aided Linear Detection Combined with Adaptive QRD-M in MIMO-OFDM Systems
This paper proposes an LR-aided adaptive QRD-M detector for complexity reduction in MIMO-OFDM systems. The proposed approach integrates lattice-reduction preprocessing with an adaptive candidate selection strategy to control the search width of the QRD-M algorithm. Unlike the conventional QRD-M detector with a fixed candidate size, the proposed method dynamically adjusts the number of surviving paths to limit unnecessary computations while preserving detection reliability. Simulation results demonstrate that the proposed detector achieves near-optimal detection performance in frequency-selective MIMO-OFDM channels, reaching a symbol error rate (SER) of 10⁻⁵ for an 8×8 system using 16-QAM modulation at high SNR. For a 4×4 configuration, the proposed method reduces computational complexity by approximately 26% in terms of average squared Euclidean distance (SED) computations compared with the conventional QRD-M detector. Analytical FLOP evaluation further confirms consistent complexity savings as the antenna dimension increases. These results demonstrate an improved performance–complexity trade-off and strong scalability for practical large-scale MIMO deployments.
- 1 September 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (3) , 72-83
Open AccessLR-Aided Linear Detection Combined with Adaptive QRD-M in MIMO-OFDM Systems
This paper proposes an LR-aided adaptive QRD-M detector for complexity reduction in MIMO-OFDM systems. The proposed approach integrates lattice-reduction preprocessing with an adaptive candidate selection strategy to control the search width of the QRD-M algorithm. Unlike the conventional QRD-M detector with a fixed candidate size, the proposed method dynamically adjusts the number of surviving paths to limit unnecessary computations while preserving detection reliability. Simulation results demonstrate that the proposed detector achieves near-optimal detection performance in frequency-selective MIMO-OFDM channels, reaching a symbol error rate (SER) of 10⁻⁵ for an 8×8 system using 16-QAM modulation at high SNR. For a 4×4 configuration, the proposed method reduces computational complexity by approximately 26% in terms of average squared Euclidean distance (SED) computations compared with the conventional QRD-M detector. Analytical FLOP evaluation further confirms consistent complexity savings as the antenna dimension increases. These results demonstrate an improved performance–complexity trade-off and strong scalability for practical large-scale MIMO deployments.
- Open Access
- 1 September 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (3) , 64-71
Stacked Ensemble Learning for Effective Flow-Based Intrusion Detection System
As developing cyber threats complexity and sophistication, traditional Network Intrusion Detection Systems (NIDS) face difficulties in detecting attacks within an acceptable time. For these challenges, this paper presents a new flow-based NIDS framework utilizing the benefits of Advanced Machine Learning methods, specifically the heterogeneous stacking ensemble. That leads to enhancing the detection performance in different attack scenarios. The proposed system merges three different base learner algorithms: Naïve Bayes (NB), Random Forest (RF), and eXtreme Gradient Boosting (XGBoost) with two different stackers(meta-learners): J48 decision tree and Logistic Regression (LR). The proposed system uses the comprehensive benchmark CSE-CIC-IDS-2018 dataset for testing and evaluation. In order to reduce the dimension of the feature space and to improve the model efficiency, feature selection is used with the aid of Mutual Information (MI). The experimental results showed that the LR-based meta-learner outperforms J48, achieving superior results of 97.98%, 98.90%, 93.92%, and 96.34% for accuracy, precision, recall, and f1-score, respectively. These results represent significant enhancements over the individual base classifiers and traditional ensemble methods. This can be used to build modern, effective cybersecurity applications that combine diverse machine learning algorithms with strategic feature engineering.
- 1 September 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (3) , 64-71
Open AccessStacked Ensemble Learning for Effective Flow-Based Intrusion Detection System
As developing cyber threats complexity and sophistication, traditional Network Intrusion Detection Systems (NIDS) face difficulties in detecting attacks within an acceptable time. For these challenges, this paper presents a new flow-based NIDS framework utilizing the benefits of Advanced Machine Learning methods, specifically the heterogeneous stacking ensemble. That leads to enhancing the detection performance in different attack scenarios. The proposed system merges three different base learner algorithms: Naïve Bayes (NB), Random Forest (RF), and eXtreme Gradient Boosting (XGBoost) with two different stackers(meta-learners): J48 decision tree and Logistic Regression (LR). The proposed system uses the comprehensive benchmark CSE-CIC-IDS-2018 dataset for testing and evaluation. In order to reduce the dimension of the feature space and to improve the model efficiency, feature selection is used with the aid of Mutual Information (MI). The experimental results showed that the LR-based meta-learner outperforms J48, achieving superior results of 97.98%, 98.90%, 93.92%, and 96.34% for accuracy, precision, recall, and f1-score, respectively. These results represent significant enhancements over the individual base classifiers and traditional ensemble methods. This can be used to build modern, effective cybersecurity applications that combine diverse machine learning algorithms with strategic feature engineering.
- Open Access
- 1 September 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (3) , 44-63
Feature-Driven Electrical Load Prediction Using Interpretable Machine Learning Models and Meta-Ensemble Learning: Evidence from Mosul’s 132 kV Grid Energy
Accurate forecasting of electrical load plays a critical role in enhancing the efficiency, reliability, and operational planning of power distribution systems—particularly in regions facing infrastructure limitations and volatile consumption patterns. This study proposes a robust forecasting framework based on real daily load data obtained from the 132 kV Al-Intisar substation in Mosul, Iraq, covering the years 2022 to 2024. The dataset, sourced in collaboration with the Nineveh Electricity Distribution Directorate, provides a practical foundation for modeling realistic demand behavior in emerging grid environments.A domain-informed and carefully engineered set of 21 predictive features was designed by the authors, integrating temporal dynamics, statistical indicators, and thermo-sensitive variables such as load-to-temperature ratios, multi-scale lag features, and moving averages. Nine machine learning models were selected to represent diverse algorithmic paradigms—ranging from tree-based methods and classical regressors to ensemble learners. Among them, the Gradient Boosting model achieved the highest accuracy Coefficient of Determination= 0.986, Mean Absolute Error= 0.260 MW, followed closely by the Meta-Learner (Coefficient of Determination = 0.983), strategically introduced in this study as a novel stacked ensemble, which demonstrated strong generalization by integrating multiple high-performing base learners. Explainability was addressed through Shapley Additive Explanations analysis and feature importance visualization, confirming the predictive value of the engineered features and enabling interpretable insights into model behavior. The findings affirm that hybrid and tree-based models, when coupled with purposeful feature design and interpretability tools, offer scalable and high-performing solutions for long-term load forecasting in real-world power systems.
- 1 September 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (3) , 44-63
Open AccessFeature-Driven Electrical Load Prediction Using Interpretable Machine Learning Models and Meta-Ensemble Learning: Evidence from Mosul’s 132 kV Grid Energy
Accurate forecasting of electrical load plays a critical role in enhancing the efficiency, reliability, and operational planning of power distribution systems—particularly in regions facing infrastructure limitations and volatile consumption patterns. This study proposes a robust forecasting framework based on real daily load data obtained from the 132 kV Al-Intisar substation in Mosul, Iraq, covering the years 2022 to 2024. The dataset, sourced in collaboration with the Nineveh Electricity Distribution Directorate, provides a practical foundation for modeling realistic demand behavior in emerging grid environments.A domain-informed and carefully engineered set of 21 predictive features was designed by the authors, integrating temporal dynamics, statistical indicators, and thermo-sensitive variables such as load-to-temperature ratios, multi-scale lag features, and moving averages. Nine machine learning models were selected to represent diverse algorithmic paradigms—ranging from tree-based methods and classical regressors to ensemble learners. Among them, the Gradient Boosting model achieved the highest accuracy Coefficient of Determination= 0.986, Mean Absolute Error= 0.260 MW, followed closely by the Meta-Learner (Coefficient of Determination = 0.983), strategically introduced in this study as a novel stacked ensemble, which demonstrated strong generalization by integrating multiple high-performing base learners. Explainability was addressed through Shapley Additive Explanations analysis and feature importance visualization, confirming the predictive value of the engineered features and enabling interpretable insights into model behavior. The findings affirm that hybrid and tree-based models, when coupled with purposeful feature design and interpretability tools, offer scalable and high-performing solutions for long-term load forecasting in real-world power systems.
- Open Access
- 1 September 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (3) , 28-43
Lightweight Quantized CNN for Real-Time Histopathological Diagnosis on Edge Devices in Digital Pathology
There is a goal to develop a fundamental deep learning system for histopathological image categorization, which operates in real-time while keeping a lightweight design to facilitate better cancer diagnostics in mobile health settings with limited resources. Accurate deep learning models are not well-suited for low-power edge devices, as they require high computational power and memory capacity and do not integrate well with user interfaces for real-time diagnostic applications. A CNN with optimization for inference latency reduction and power efficiency was achieved through a design approach that included quantization-aware network pruning to maintain performance and decrease model size. The proposed model implements grouped convolutional processing while decreasing its filter width, together with mixed-precision quantization, which enables INT8 convolutions combined with FP16 batch normalization and FP32 fully connected layer operation through a MATLAB graphical user interface that enables users to select images, along with automatic diagnostic report generation with label watermarking. The experimental results show that the system achieves 99.14% classification precision, with a model dimension of 263 KB and a runtime of 2.63 milliseconds, producing better or equivalent results compared to the lightweight ShuffleNet and MobileNetV2 architectures based on F1-score, throughput, and energy efficiency metrics. This work takes the concept of deep learning closer to practice by introducing an effective end-to-end prototype, but additional cross-dataset validation, on-edge device benchmarking, and interpretability to clinicians will be needed to make it clinically ready
- 1 September 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (3) , 28-43
Open AccessLightweight Quantized CNN for Real-Time Histopathological Diagnosis on Edge Devices in Digital Pathology
There is a goal to develop a fundamental deep learning system for histopathological image categorization, which operates in real-time while keeping a lightweight design to facilitate better cancer diagnostics in mobile health settings with limited resources. Accurate deep learning models are not well-suited for low-power edge devices, as they require high computational power and memory capacity and do not integrate well with user interfaces for real-time diagnostic applications. A CNN with optimization for inference latency reduction and power efficiency was achieved through a design approach that included quantization-aware network pruning to maintain performance and decrease model size. The proposed model implements grouped convolutional processing while decreasing its filter width, together with mixed-precision quantization, which enables INT8 convolutions combined with FP16 batch normalization and FP32 fully connected layer operation through a MATLAB graphical user interface that enables users to select images, along with automatic diagnostic report generation with label watermarking. The experimental results show that the system achieves 99.14% classification precision, with a model dimension of 263 KB and a runtime of 2.63 milliseconds, producing better or equivalent results compared to the lightweight ShuffleNet and MobileNetV2 architectures based on F1-score, throughput, and energy efficiency metrics. This work takes the concept of deep learning closer to practice by introducing an effective end-to-end prototype, but additional cross-dataset validation, on-edge device benchmarking, and interpretability to clinicians will be needed to make it clinically ready
- Open Access
- 1 September 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (3) , 16-27
Evaluating the Mechanical and Durability Performance of Carbon-Sulfur Mix Asphalt Modified with SBS and SZ additives
The rising quantities of the blowdown (carbon-sulfur) hydrocarbon waste generated in the production of sulfur posed challenges to the environment in Iraq. This research paper explored the application of blowdown as a sustainable filler in asphalt mix that had been modified with SBS polymer and synthetic zeolite (SZ) additives. Six asphalt mixtures were prepared with blowdown and traditional fillers of CaCO3 and were tested concerning mechanical and durability performances, using Marshall stability, indirect tensile strength, and deformation strength tests. Findings indicated that the SBS-modified blowdown mixtures had better strength, cracking, and rutting resistance than any other mixtures. These results proved that blowdown waste can be a good filler to be used in sustainable pavements to provide improved performance and environmental advantages
- 1 September 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (3) , 16-27
Open AccessEvaluating the Mechanical and Durability Performance of Carbon-Sulfur Mix Asphalt Modified with SBS and SZ additives
The rising quantities of the blowdown (carbon-sulfur) hydrocarbon waste generated in the production of sulfur posed challenges to the environment in Iraq. This research paper explored the application of blowdown as a sustainable filler in asphalt mix that had been modified with SBS polymer and synthetic zeolite (SZ) additives. Six asphalt mixtures were prepared with blowdown and traditional fillers of CaCO3 and were tested concerning mechanical and durability performances, using Marshall stability, indirect tensile strength, and deformation strength tests. Findings indicated that the SBS-modified blowdown mixtures had better strength, cracking, and rutting resistance than any other mixtures. These results proved that blowdown waste can be a good filler to be used in sustainable pavements to provide improved performance and environmental advantages
- Open Access
- 1 September 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (3) , 1-15
Influence of EV Charging Stations on the Performances of Three-Phase Distribution Transformers in Residential Grids
Electric vehicle charging stations significantly impact the performance of three-phase (11/0.4 kV) distribution transformers, as unbalanced and variable loads lead to higher temperatures and increased power loss. They also contribute to reduced transformer life and increased risk of failure. This paper demonstrates the impact by analyzing the challenges arising from the nonlinear and variable nature of electric vehicle charging loads, such as harmonic distortions, electrical stresses, and voltage imbalance. The electrical network was simulated using the Electrical Transient Analyzer Program (ETAP) software, and the potential risks to (11/0.4 kV) distribution transformers due to nonlinear and variable charging loads were identified. The results revealed that the distribution transformer's capacitance near to the loads (T3) suffered a 12.40 % voltage drop at full load. On the other hand, the total distortion on the secondary side of the transformer (T3) reached 55.71% for a six-pulse, single-harmonic IEEE source and 40.53% for a twelve-pulse, single-harmonic IEEE source. This analysis indicates a potential risk to transformer performance, which calls for consideration of adding harmonic filters to improve power quality. It also aims to enhance the reliability and efficiency of converters by providing accurate analyses and simulations of the impact of electric vehicle charging stations on converter performance.
- 1 September 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (3) , 1-15
Open AccessInfluence of EV Charging Stations on the Performances of Three-Phase Distribution Transformers in Residential Grids
Electric vehicle charging stations significantly impact the performance of three-phase (11/0.4 kV) distribution transformers, as unbalanced and variable loads lead to higher temperatures and increased power loss. They also contribute to reduced transformer life and increased risk of failure. This paper demonstrates the impact by analyzing the challenges arising from the nonlinear and variable nature of electric vehicle charging loads, such as harmonic distortions, electrical stresses, and voltage imbalance. The electrical network was simulated using the Electrical Transient Analyzer Program (ETAP) software, and the potential risks to (11/0.4 kV) distribution transformers due to nonlinear and variable charging loads were identified. The results revealed that the distribution transformer's capacitance near to the loads (T3) suffered a 12.40 % voltage drop at full load. On the other hand, the total distortion on the secondary side of the transformer (T3) reached 55.71% for a six-pulse, single-harmonic IEEE source and 40.53% for a twelve-pulse, single-harmonic IEEE source. This analysis indicates a potential risk to transformer performance, which calls for consideration of adding harmonic filters to improve power quality. It also aims to enhance the reliability and efficiency of converters by providing accurate analyses and simulations of the impact of electric vehicle charging stations on converter performance.
- Open Access
- 1 September 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (3) , 84-103
Machine Learning Multi-Class Intrusion DetectionSystem Using Embedded Feature Selection and Multi-Level Hierarchy Classification
In recent years, network security has attracted significant research attention due to the growing frequency of attacks on computer networks. Among existing solutions, “Network Intrusion Detection Systems (NIDS)” play a central role. While binary NIDS effectively distinguish between normal and malicious traffic, they cannot accurately classify specific attack types. Multi-class intrusion detection systems address this limitation by enabling tailored responses for each attack category. This paper presents the development of a “multi-class Intrusion Detection System (IDS)” that integrates “Recursive Feature Addition (RFA)”, an embedded feature selection technique, with multi-level binary classifiers. The proposed system was evaluated using five machine learning algorithms: “Support Vector Machines (SVM)”, “Random Forests”, “J48”, “Random Tree”, and “J48Graft”. A hierarchical binary tree structure was employed to implement the multi-class detection, with performance assessed under two dataset distribution scenarios: “balanced” and “imbalanced”. To construct the overall “multi-class confusion matrix”, a novel estimation method that combines intermediate matrices from each binary sub-tree has been introduced.The ISCX 2012 intrusion detection benchmark dataset was used for evaluation, with results measured across five metrics: “Accuracy”, “F1-score”, “Detection Rate”, “False Alarm Rate (FAR)”, and “Precision”. Experimental findings show that “Random Tree” consistently achieved the best performance across both scenarios. For “balanced” datasets, it excelled in detecting DoS attacks, while for “imbalanced” datasets, it demonstrated superior efficiency in identifying Internal attacks. In addition, the proposed approach has demonstrated superiority over the baseline in terms of time required for (feature selection + classification hierarchy) and key metrics. These results highlight the effectiveness of the proposed multi-class IDS framework for enhancing intrusion detection in complex network environments
- 1 September 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (3) , 84-103
Open AccessMachine Learning Multi-Class Intrusion DetectionSystem Using Embedded Feature Selection and Multi-Level Hierarchy Classification
In recent years, network security has attracted significant research attention due to the growing frequency of attacks on computer networks. Among existing solutions, “Network Intrusion Detection Systems (NIDS)” play a central role. While binary NIDS effectively distinguish between normal and malicious traffic, they cannot accurately classify specific attack types. Multi-class intrusion detection systems address this limitation by enabling tailored responses for each attack category. This paper presents the development of a “multi-class Intrusion Detection System (IDS)” that integrates “Recursive Feature Addition (RFA)”, an embedded feature selection technique, with multi-level binary classifiers. The proposed system was evaluated using five machine learning algorithms: “Support Vector Machines (SVM)”, “Random Forests”, “J48”, “Random Tree”, and “J48Graft”. A hierarchical binary tree structure was employed to implement the multi-class detection, with performance assessed under two dataset distribution scenarios: “balanced” and “imbalanced”. To construct the overall “multi-class confusion matrix”, a novel estimation method that combines intermediate matrices from each binary sub-tree has been introduced.The ISCX 2012 intrusion detection benchmark dataset was used for evaluation, with results measured across five metrics: “Accuracy”, “F1-score”, “Detection Rate”, “False Alarm Rate (FAR)”, and “Precision”. Experimental findings show that “Random Tree” consistently achieved the best performance across both scenarios. For “balanced” datasets, it excelled in detecting DoS attacks, while for “imbalanced” datasets, it demonstrated superior efficiency in identifying Internal attacks. In addition, the proposed approach has demonstrated superiority over the baseline in terms of time required for (feature selection + classification hierarchy) and key metrics. These results highlight the effectiveness of the proposed multi-class IDS framework for enhancing intrusion detection in complex network environments
- Open Access
- 1 June 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (2) , 56-68
Enhancing Single-Phase Transformer Performance with A Pass-Tune Filter Under Various Load Conditions
Although single-phase transformers are crucial parts of contemporary electrical power networks, reactive power demands and harmonic distortions can severely impair their performance under non-linear. In order to improve transformer performance by reducing harmonic distortions and enhancing power quality, this study suggests integrating a pass-tune filter. The study shows how the suggested filter affects transformer efficiency and voltage control under a range of load conditions, such as linear, non-linear, and fluctuating loads. A single-phase transformer (3 KVA, 220 volts, and 50 Hz) is simulated in this work. Different topologies of filters have been used in this work. The results demonstrate the pass-tune filter's potential as an affordable remedy for power quality problems, guaranteeing dependable transformer operation in practical applications. Different loads (linear load and non-linear load) before and after adding the filters were examined. THD due to higher distortion in the R-L load reaches 22% and 49% for the voltage and current, respectively. Fast Fourier Transform (FFT) analysis after applying the filters to both voltage and current shows acceptable total harmonic distortion values within standards (less than 5%). Simulation findings show that the pass-tune filter effectively reduces losses, improves overall operating stability, and lowers total harmonic distortion (THD).
- 1 June 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (2) , 56-68
Open AccessEnhancing Single-Phase Transformer Performance with A Pass-Tune Filter Under Various Load Conditions
Although single-phase transformers are crucial parts of contemporary electrical power networks, reactive power demands and harmonic distortions can severely impair their performance under non-linear. In order to improve transformer performance by reducing harmonic distortions and enhancing power quality, this study suggests integrating a pass-tune filter. The study shows how the suggested filter affects transformer efficiency and voltage control under a range of load conditions, such as linear, non-linear, and fluctuating loads. A single-phase transformer (3 KVA, 220 volts, and 50 Hz) is simulated in this work. Different topologies of filters have been used in this work. The results demonstrate the pass-tune filter's potential as an affordable remedy for power quality problems, guaranteeing dependable transformer operation in practical applications. Different loads (linear load and non-linear load) before and after adding the filters were examined. THD due to higher distortion in the R-L load reaches 22% and 49% for the voltage and current, respectively. Fast Fourier Transform (FFT) analysis after applying the filters to both voltage and current shows acceptable total harmonic distortion values within standards (less than 5%). Simulation findings show that the pass-tune filter effectively reduces losses, improves overall operating stability, and lowers total harmonic distortion (THD).
- Open Access
- 1 June 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (2) , 7-22
Power System Contingency Study of On-Grid Renewable Energy Resources with D.G. in a Different Conditions
Contingency studies are conducted to assess the importance and reliability of power control systems by evaluating unspecified equipment outages under various conditions. This study conducts a comprehensive contingency analysis of a hybrid power system including distributed generators (D.G.s), wind farms, solar photovoltaic arrays, and grid connections to evaluate its resilience under N-1 power outage scenarios. Steady-state, dynamic, and voltage stability analyses are performed using Newton-Raphson and fast power flow simulations. The study presents key performance indicators for steady-state and dynamic responses, addressing voltage stability, thermal overload, and power flow redistribution. Mitigation strategies are proposed, including partial power compensation, ready-to-use generation scheduling, load shedding, and system resilience. The study also highlights the importance of contingency analysis based on reliable NERC/WECC standards and indicates how changing conditions impact grid resilience. The ETAP analysis supports an N-1 evaluation and the strategies used to determine system performance parameters, providing optimized operating thresholds for each component in the power system through the addition of user-defined components and failure scenarios. A hybrid power system was analyzed based on the separation of busbars, cables, distribution generator, transformers, wind generators, and the solar array. The study presents a new composite performance index (CPI) for use with hybrid power systems, integrating four sub-indices: voltage integrity (V/Vsp), real and reactive power deviations (ΔP and ΔQ), and branch overload (S/Ssp) to classify the severity of the contingency. The results show that the power outage on bus 1 (connected to the main grid) is the most severe (CPI = 103.065). In contrast, the outage's impact on the photovoltaic arrays is minimal (CPI < 1), highlighting the system's reliance on centralized generation. The study also shows that proximity to high-power transmission elements enhances the impact of the contingency, while distributed renewable energy sources enhance resilience. This work provides practical insights for grid operators managing hybrid systems amid increasing renewable energy deployment and climate-induced disruptions. A reliable power grid isn’t just about avoiding blackouts, it’s about designing systems that can adapt, recover, and keep electricity flowing even when things go wrong. This paper provides both the tools and the mindset needed to build that future.
- 1 June 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (2) , 7-22
Open AccessPower System Contingency Study of On-Grid Renewable Energy Resources with D.G. in a Different Conditions
Contingency studies are conducted to assess the importance and reliability of power control systems by evaluating unspecified equipment outages under various conditions. This study conducts a comprehensive contingency analysis of a hybrid power system including distributed generators (D.G.s), wind farms, solar photovoltaic arrays, and grid connections to evaluate its resilience under N-1 power outage scenarios. Steady-state, dynamic, and voltage stability analyses are performed using Newton-Raphson and fast power flow simulations. The study presents key performance indicators for steady-state and dynamic responses, addressing voltage stability, thermal overload, and power flow redistribution. Mitigation strategies are proposed, including partial power compensation, ready-to-use generation scheduling, load shedding, and system resilience. The study also highlights the importance of contingency analysis based on reliable NERC/WECC standards and indicates how changing conditions impact grid resilience. The ETAP analysis supports an N-1 evaluation and the strategies used to determine system performance parameters, providing optimized operating thresholds for each component in the power system through the addition of user-defined components and failure scenarios. A hybrid power system was analyzed based on the separation of busbars, cables, distribution generator, transformers, wind generators, and the solar array. The study presents a new composite performance index (CPI) for use with hybrid power systems, integrating four sub-indices: voltage integrity (V/Vsp), real and reactive power deviations (ΔP and ΔQ), and branch overload (S/Ssp) to classify the severity of the contingency. The results show that the power outage on bus 1 (connected to the main grid) is the most severe (CPI = 103.065). In contrast, the outage's impact on the photovoltaic arrays is minimal (CPI < 1), highlighting the system's reliance on centralized generation. The study also shows that proximity to high-power transmission elements enhances the impact of the contingency, while distributed renewable energy sources enhance resilience. This work provides practical insights for grid operators managing hybrid systems amid increasing renewable energy deployment and climate-induced disruptions. A reliable power grid isn’t just about avoiding blackouts, it’s about designing systems that can adapt, recover, and keep electricity flowing even when things go wrong. This paper provides both the tools and the mindset needed to build that future.
- Open Access
- 1 June 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (2) , 23-37
Effect of Attention Mechanisms in a Fuzzified Nested U-Net for Medical Image Segmentation
Accurate segmentation of cardiac structures (right ventricle (RV), left ventricle (LV), and myocardium (Myo)) from cardiac MRI images plays an important role in the diagnosis and treatment of cardiovascular disease. However, despite all this, segmentation of these structures at the micro level remains a major challenge due to the complex anatomical diversity and noise inherent in MRI data. This paper examines the performance of various cardiac MRI segmentation techniques, with a primary focus on the overlapping U-Net structure, attention mechanisms, and fuzzy pooling strategies. This study comprehensively evaluates these methods, both independently and in combination, to determine their effectiveness in improving segmentation quality for the RV, LV, and myocardial regions. Additionally, the effect of thresholding strategies on segmentation accuracy is examined. The experimental results on the Automated Cardiac Diagnosis Challenge (ACDC) dataset show that the proposed model (combining nested U-Net, attention mechanisms, and fuzzy pooling) achieved a dice score of 98.20%, an accuracy of 96.83%, and a recall of 96.83%, superior to other basic methods. In comparison, the best-performing core model, ANU-Net, achieved a Dice score of 94.31%, accuracy of 95.19%, and recall of 93.44%. These findings underscore the superior performance of the hybrid model in terms of segmentation and boundary delineation accuracy. These results confirm the potential of hybrid deep learning models in developing cardiac image analysis. Future work will focus on improving these configurations across diverse datasets and also exploring real-time deployment strategies in clinical settings.
- 1 June 2026
- Published by University of Mosul in Al-Rafidain Engineering Journal (AREJ)
- Vol. 31 (2) , 23-37
Open AccessEffect of Attention Mechanisms in a Fuzzified Nested U-Net for Medical Image Segmentation
Accurate segmentation of cardiac structures (right ventricle (RV), left ventricle (LV), and myocardium (Myo)) from cardiac MRI images plays an important role in the diagnosis and treatment of cardiovascular disease. However, despite all this, segmentation of these structures at the micro level remains a major challenge due to the complex anatomical diversity and noise inherent in MRI data. This paper examines the performance of various cardiac MRI segmentation techniques, with a primary focus on the overlapping U-Net structure, attention mechanisms, and fuzzy pooling strategies. This study comprehensively evaluates these methods, both independently and in combination, to determine their effectiveness in improving segmentation quality for the RV, LV, and myocardial regions. Additionally, the effect of thresholding strategies on segmentation accuracy is examined. The experimental results on the Automated Cardiac Diagnosis Challenge (ACDC) dataset show that the proposed model (combining nested U-Net, attention mechanisms, and fuzzy pooling) achieved a dice score of 98.20%, an accuracy of 96.83%, and a recall of 96.83%, superior to other basic methods. In comparison, the best-performing core model, ANU-Net, achieved a Dice score of 94.31%, accuracy of 95.19%, and recall of 93.44%. These findings underscore the superior performance of the hybrid model in terms of segmentation and boundary delineation accuracy. These results confirm the potential of hybrid deep learning models in developing cardiac image analysis. Future work will focus on improving these configurations across diverse datasets and also exploring real-time deployment strategies in clinical settings.