Turkish Journal of Electrical Power and Energy Systems
Published by Türkiye Elektrik Sanayi Birliği Derneği
- Scilit
- Power Systems & Electric Vehicles
Publications Analysis
Publications in 2016-2026
Open Access Publications in 2016-2026
- Total Citations
- 45
- Total Publications
- 38
- Average Citations
- 1.18
- Cited Publications
- 18
- Cited Publications %
- 47.4%
- Self Citations
- 0
- Self Citations %
- 0%
- Q1
- 0
- Med
- 2
- Q3
- 5
- 99%
- 11.3
- Max
- 12
- Citing Source Titles
- Citing Publishers
Latest Publications
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 203-215
Optimal Allocation of Battery Energy Storage Systems in Solar Integrated Distribution Networks Using Particle Swarm Optimization Technique
This study presents an efficient methodology for the optimal sizing and placement of Battery Energy Storage Systems (BESS) in distribution networks with pre-installed solar PV Distributed Generators (DGs). High solar photovoltaic (PV) penetration in distribution networks often leads to challenges such as voltage rise, reverse power flow, and increased daytime losses, thereby motivating the integration of BESS to effectively mitigate these issues. However, some of these issues can be exacerbated when the capacity and placement of BESS are not correctly optimized. The proposed approach employs Particle Swarm Optimization (PSO) to determine optimal BESS locations and capacities, aiming at minimizing energy losses while adhering to technical constraints such as feeder voltage and current limits, power balance, and BESS state of charge (SOC) boundaries. The methodology is validated through two case studies: a modified IEEE 33-bus network with integrated solar PV DGs and a practical feeder located in Kurunegala, Sri Lanka. The convergence statistics of this study confirm the effectiveness of the developed PSO algorithm in identifying optimal results, justifying its computational efficiency and robustness. Results of two case studies demonstrate that the optimal BESS placement significantly reduces daily energy losses while improving the voltage profile of the network. Therefore, the proposed framework provides a practical solution for improving reliability, energy efficiency, and solar PV hosting capacity in modern distribution networks through effective BESS integration while mitigating challenges associated with high solar PV penetration.
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 203-215
Optimal Allocation of Battery Energy Storage Systems in Solar Integrated Distribution Networks Using Particle Swarm Optimization Technique
This study presents an efficient methodology for the optimal sizing and placement of Battery Energy Storage Systems (BESS) in distribution networks with pre-installed solar PV Distributed Generators (DGs). High solar photovoltaic (PV) penetration in distribution networks often leads to challenges such as voltage rise, reverse power flow, and increased daytime losses, thereby motivating the integration of BESS to effectively mitigate these issues. However, some of these issues can be exacerbated when the capacity and placement of BESS are not correctly optimized. The proposed approach employs Particle Swarm Optimization (PSO) to determine optimal BESS locations and capacities, aiming at minimizing energy losses while adhering to technical constraints such as feeder voltage and current limits, power balance, and BESS state of charge (SOC) boundaries. The methodology is validated through two case studies: a modified IEEE 33-bus network with integrated solar PV DGs and a practical feeder located in Kurunegala, Sri Lanka. The convergence statistics of this study confirm the effectiveness of the developed PSO algorithm in identifying optimal results, justifying its computational efficiency and robustness. Results of two case studies demonstrate that the optimal BESS placement significantly reduces daily energy losses while improving the voltage profile of the network. Therefore, the proposed framework provides a practical solution for improving reliability, energy efficiency, and solar PV hosting capacity in modern distribution networks through effective BESS integration while mitigating challenges associated with high solar PV penetration.
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 216-230
Impact of Non-Technical Losses on The Electricity Grid in Smart Grids: The Case of Dicle Electric Ditribution Company
Non-technical losses (NTL) in electricity distribution networks are not only a economic and commercial issue but also a critical engineering problem that shortens the life of network equipment, degrades power quality, and threatens system reliability. In cases where individual subscriber consumption data is inaccessible or privacy constraints exist, detecting illegal usage poses a significant challenge. The main objective of this study is to empirically prove that macro-level electrical anomalies carry the characteristics of non-technical losses by using the Automated Meter Reading System (AMR) secondary data belonging to a specific distribution transformer located in the responsibility area of Dicle Electricity Distribution Corporation. Within the scope of the study; load profiles, power factor collapses, net reactive power asymmetry, inter-phase current-voltage unbalances, and voltage sags were analyzed in depth. As a result of the analyses, it was determined that uncompensated and single-phase loaded illegal usages reduce the power factor of the transformer to dangerous levels, create severe phase asymmetry causing overloads on the neutral line, and push voltage profiles out of standards. The findings demonstrate that without direct household-based data, non-technical losses can be detected with high accuracy by processing macro anomalies solely in transformer output parameters using statistical analysis methods.
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 216-230
Impact of Non-Technical Losses on The Electricity Grid in Smart Grids: The Case of Dicle Electric Ditribution Company
Non-technical losses (NTL) in electricity distribution networks are not only a economic and commercial issue but also a critical engineering problem that shortens the life of network equipment, degrades power quality, and threatens system reliability. In cases where individual subscriber consumption data is inaccessible or privacy constraints exist, detecting illegal usage poses a significant challenge. The main objective of this study is to empirically prove that macro-level electrical anomalies carry the characteristics of non-technical losses by using the Automated Meter Reading System (AMR) secondary data belonging to a specific distribution transformer located in the responsibility area of Dicle Electricity Distribution Corporation. Within the scope of the study; load profiles, power factor collapses, net reactive power asymmetry, inter-phase current-voltage unbalances, and voltage sags were analyzed in depth. As a result of the analyses, it was determined that uncompensated and single-phase loaded illegal usages reduce the power factor of the transformer to dangerous levels, create severe phase asymmetry causing overloads on the neutral line, and push voltage profiles out of standards. The findings demonstrate that without direct household-based data, non-technical losses can be detected with high accuracy by processing macro anomalies solely in transformer output parameters using statistical analysis methods.
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 155-166
Optimal Power Flow Control and Emergency Voltage Control with A Unified Power Flow Controller (UPFC) to Improve The Performance of The Power System
The increasing global energy demand has intensified pressure on existing transmission infrastructure, giving rise to thermal overloads, voltage instability, and elevated power losses. Flexible Alternating Current Transmission System (FACTS) devices have emerged as a technically viable solution to enhance the controllability and power transfer capability of existing networks without significant infrastructural expansion. Among FACTS controllers, the Unified Power Flow Controller (UPFC) is distinguished as the most versatile device, capable of regulating active power flow, reactive power flow, and bus voltage magnitude simultaneously. This paper presents a comprehensive simulation study of UPFC performance using the IEEE 9-bus benchmark transmission network, which was modeled in DIgSILENT PowerFactory. The voltage stability indices and line stability factors identify Bus 8 as the optimal point for UPFC installation. Four simulation scenarios are investigated: the base case without UPFC, UPFC integrated at Bus 8 under normal full-load conditions, N-1 line contingency with three compensation strategies compared, and a generator outage response. The findings indicate that the integration of UPFC results in a 19.64% decrease in active power losses and a 32.74% decrease in reactive power losses. In the context of the N-1 line contingency, the uncompensated system permits a voltage collapse of Bus 8 to 0.909 pu. However, UPFC effectively restores the voltage to above 1.020 pu within approximately 20 seconds, thereby demonstrating a substantial performance enhancement in comparison to the fixed capacitor bank compensation. During generator outages, the UPFC has been shown to limit the Bus 7 voltage dip to 0.986 pu with rapid stabilization in comparison to a sustained depression to 0.967 pu without compensation. The findings confirm the technical superiority of UPFC as a multi-functional FACTS controller for modernizing voltage-constrained transmission networks.
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 155-166
Optimal Power Flow Control and Emergency Voltage Control with A Unified Power Flow Controller (UPFC) to Improve The Performance of The Power System
The increasing global energy demand has intensified pressure on existing transmission infrastructure, giving rise to thermal overloads, voltage instability, and elevated power losses. Flexible Alternating Current Transmission System (FACTS) devices have emerged as a technically viable solution to enhance the controllability and power transfer capability of existing networks without significant infrastructural expansion. Among FACTS controllers, the Unified Power Flow Controller (UPFC) is distinguished as the most versatile device, capable of regulating active power flow, reactive power flow, and bus voltage magnitude simultaneously. This paper presents a comprehensive simulation study of UPFC performance using the IEEE 9-bus benchmark transmission network, which was modeled in DIgSILENT PowerFactory. The voltage stability indices and line stability factors identify Bus 8 as the optimal point for UPFC installation. Four simulation scenarios are investigated: the base case without UPFC, UPFC integrated at Bus 8 under normal full-load conditions, N-1 line contingency with three compensation strategies compared, and a generator outage response. The findings indicate that the integration of UPFC results in a 19.64% decrease in active power losses and a 32.74% decrease in reactive power losses. In the context of the N-1 line contingency, the uncompensated system permits a voltage collapse of Bus 8 to 0.909 pu. However, UPFC effectively restores the voltage to above 1.020 pu within approximately 20 seconds, thereby demonstrating a substantial performance enhancement in comparison to the fixed capacitor bank compensation. During generator outages, the UPFC has been shown to limit the Bus 7 voltage dip to 0.986 pu with rapid stabilization in comparison to a sustained depression to 0.967 pu without compensation. The findings confirm the technical superiority of UPFC as a multi-functional FACTS controller for modernizing voltage-constrained transmission networks.
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 143-154
Performance Assessment of FCS-MPCC and DPCC for PMSM Drives Under Matched Average Switching Frequency Conditions
Finite Control Set Model Predictive Current Control (FCS-MPCC) and Deadbeat Predictive Current Control (DPCC) for Permanent Magnet Synchronous Machine (PMSM) drives are comparatively evaluated in this study. To ensure a fair comparison, both control techniques are evaluated using the same machine model and under a variety of operating conditions, including different speed and current commands. The FCS-MPCC method operates with a variable switching frequency, whereas the DPCC method has a constant switching frequency. Therefore, the average switching frequency of the FCS-MPCC method is measured for each operating condition and used to determine the appropriate switching frequency for the DPCC method. This enables a consistent comparison to be made under equivalent switching effort. A comparative analysis is conducted across multiple operating points in order to capture the performance variations of the two control strategies under different speed and current commands. Simulation results indicate that, under identical switching frequency and sampling constraints, the DPCC method generally achieves lower current tracking errors and reduced current Total Harmonic Distortion (THD) compared to the FCS-MPCC method. However, it has also been revealed by the results that the performance of FCS-MPCC is dependent on the selected sampling period. A thorough investigation of the effect of sampling time reveals that reducing the sampling interval greatly improves the current tracking accuracy and harmonic performance of the FCS-MPCC. When the sampling period is small enough, FCS-MPCC can perform comparably to, or even better than, DPCC. However, this comes with a higher switching frequency and more computational burden. Overall, the findings emphasise the trade-off between control performance, switching effort, and implementation complexity. The selection of predictive current control strategies for PMSM drives can be approached via these comparative studies.
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 143-154
Performance Assessment of FCS-MPCC and DPCC for PMSM Drives Under Matched Average Switching Frequency Conditions
Finite Control Set Model Predictive Current Control (FCS-MPCC) and Deadbeat Predictive Current Control (DPCC) for Permanent Magnet Synchronous Machine (PMSM) drives are comparatively evaluated in this study. To ensure a fair comparison, both control techniques are evaluated using the same machine model and under a variety of operating conditions, including different speed and current commands. The FCS-MPCC method operates with a variable switching frequency, whereas the DPCC method has a constant switching frequency. Therefore, the average switching frequency of the FCS-MPCC method is measured for each operating condition and used to determine the appropriate switching frequency for the DPCC method. This enables a consistent comparison to be made under equivalent switching effort. A comparative analysis is conducted across multiple operating points in order to capture the performance variations of the two control strategies under different speed and current commands. Simulation results indicate that, under identical switching frequency and sampling constraints, the DPCC method generally achieves lower current tracking errors and reduced current Total Harmonic Distortion (THD) compared to the FCS-MPCC method. However, it has also been revealed by the results that the performance of FCS-MPCC is dependent on the selected sampling period. A thorough investigation of the effect of sampling time reveals that reducing the sampling interval greatly improves the current tracking accuracy and harmonic performance of the FCS-MPCC. When the sampling period is small enough, FCS-MPCC can perform comparably to, or even better than, DPCC. However, this comes with a higher switching frequency and more computational burden. Overall, the findings emphasise the trade-off between control performance, switching effort, and implementation complexity. The selection of predictive current control strategies for PMSM drives can be approached via these comparative studies.
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 231-240
GridMind: Issue-Time-Safe Cross-Country Load Forecasting with Conformal Uncertainty and Operator-Aware Model Selection
Operational electricity forecasting must be accurate, uncertainty-aware, and protected against future-information leakage. This study presents GridMind, an operator-oriented champion-challenger framework combining a forecast-origin feature ledger, Light Gradient Boosting Machine point forecasts, rolling split-conformal intervals, reproducible feature evidence, and an explicit retain-or-replace decision. The framework was evaluated on complementary national datasets from Panama and Spain. For Panama, the exact 14 published 168-hour test weeks and the prescribed 72-hour unseen gap were reproduced. Target-week realized weather was excluded, and only completed-week load lags and known calendar variables were used. The model achieved 4.193% pooled MAPE, 63.796 MWh RMSE, and a 28.26% reduction in mean weekly MAPE relative to a safe 336-hour seasonal-naive benchmark. It improved 11 of 14 weeks; the mean paired improvement was 1.652 percentage points (bootstrap 95% CI 0.670-2.903; one-sided Wilcoxon p=0.002625). Nominal 90% split-conformal intervals attained 89.97% pooled coverage. For Spain, the public operator forecast remained the champion: H2-2018 MAPE was 0.8855%, compared with 0.8947% after forecast-origin-safe residual correction. GridMind therefore provides an auditable pattern for feature availability, accuracy, calibrated uncertainty, and operational model governance without assuming that a machine-learning challenger must replace the incumbent.
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 231-240
GridMind: Issue-Time-Safe Cross-Country Load Forecasting with Conformal Uncertainty and Operator-Aware Model Selection
Operational electricity forecasting must be accurate, uncertainty-aware, and protected against future-information leakage. This study presents GridMind, an operator-oriented champion-challenger framework combining a forecast-origin feature ledger, Light Gradient Boosting Machine point forecasts, rolling split-conformal intervals, reproducible feature evidence, and an explicit retain-or-replace decision. The framework was evaluated on complementary national datasets from Panama and Spain. For Panama, the exact 14 published 168-hour test weeks and the prescribed 72-hour unseen gap were reproduced. Target-week realized weather was excluded, and only completed-week load lags and known calendar variables were used. The model achieved 4.193% pooled MAPE, 63.796 MWh RMSE, and a 28.26% reduction in mean weekly MAPE relative to a safe 336-hour seasonal-naive benchmark. It improved 11 of 14 weeks; the mean paired improvement was 1.652 percentage points (bootstrap 95% CI 0.670-2.903; one-sided Wilcoxon p=0.002625). Nominal 90% split-conformal intervals attained 89.97% pooled coverage. For Spain, the public operator forecast remained the champion: H2-2018 MAPE was 0.8855%, compared with 0.8947% after forecast-origin-safe residual correction. GridMind therefore provides an auditable pattern for feature availability, accuracy, calibrated uncertainty, and operational model governance without assuming that a machine-learning challenger must replace the incumbent.
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 178-191
Modeling and Simulation of Reactive Power Compensation Using a Synchronous Motor with Excitation Control in MATLAB/Simulink
This study investigates reactive power compensation using a synchronous motor in a three-phase electrical power system without conventional capacitor banks through MATLAB/Simulink-based modeling and simulation. The proposed system consists of inductive loads and a 15 kVA synchronous motor operating as a dynamic reactive power compensator via excitation current control. Different operating conditions were analyzed by varying the excitation voltage and current parameters. The simulation results demonstrated that the proposed compensation method significantly reduced reactive power demand and improved the overall system power factor to nearly unity (PF ≈ 1.00). In addition, the apparent power demand decreased from 24 kVA to 21.63 kVA under optimized operating conditions, resulting in lower transmission line current, reduced power losses, improved voltage stability, and enhanced overall system efficiency. The findings confirm that synchronous motor-based reactive power compensation provides a flexible, reliable, and dynamically controllable alternative to conventional capacitor bank systems under varying load conditions.
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 178-191
Modeling and Simulation of Reactive Power Compensation Using a Synchronous Motor with Excitation Control in MATLAB/Simulink
This study investigates reactive power compensation using a synchronous motor in a three-phase electrical power system without conventional capacitor banks through MATLAB/Simulink-based modeling and simulation. The proposed system consists of inductive loads and a 15 kVA synchronous motor operating as a dynamic reactive power compensator via excitation current control. Different operating conditions were analyzed by varying the excitation voltage and current parameters. The simulation results demonstrated that the proposed compensation method significantly reduced reactive power demand and improved the overall system power factor to nearly unity (PF ≈ 1.00). In addition, the apparent power demand decreased from 24 kVA to 21.63 kVA under optimized operating conditions, resulting in lower transmission line current, reduced power losses, improved voltage stability, and enhanced overall system efficiency. The findings confirm that synchronous motor-based reactive power compensation provides a flexible, reliable, and dynamically controllable alternative to conventional capacitor bank systems under varying load conditions.
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 241-254
Economic Impacts of Large-Scale Power Outages: Global Blackouts, Reliability Metrics, and Value of Lost Load
Large-scale power outages have become a major concern not only for power-system reliability but also for economic resilience, social continuity, and critical infrastructure security. This review examines the economic impacts of major blackout events by linking outage causes, reliability metrics, sectoral interruption costs, and Value of Lost Load (VoLL)-based assessment methods. To establish a consistent analytical framework, the paper distinguishes customer-based reliability indices from energy-based measures such as Energy Not Supplied (ENS) and Expected Energy Not Served (EENS). It also clarifies the role of adequacy metrics, including Loss of Load Probability (LOLP) and Loss of Load Expectation (LOLE), and microgrid-oriented indicators such as Loss of Power Supply (LPS) and Loss of Power Supply Probability (LPSP). The review emphasizes that probability- or duration-based indices cannot be directly converted into monetary losses unless they are first expressed as energy-not-served quantities. Evidence from major events, including India 2012, North America 2003, Italy 2003, Türkiye 2015, Texas 2021, Iberia 2025, and Chile 2025, shows that outage consequences depend on the interaction between technical failure mechanisms, interruption duration, affected sectors, restoration processes, and infrastructure interdependencies. The study concludes that future outage-cost assessments should rely on transparent data reliability levels, updated sectoral cost data, dynamic VoLL estimates, and dimensionally consistent links between reliability indicators and economic losses.
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 241-254
Economic Impacts of Large-Scale Power Outages: Global Blackouts, Reliability Metrics, and Value of Lost Load
Large-scale power outages have become a major concern not only for power-system reliability but also for economic resilience, social continuity, and critical infrastructure security. This review examines the economic impacts of major blackout events by linking outage causes, reliability metrics, sectoral interruption costs, and Value of Lost Load (VoLL)-based assessment methods. To establish a consistent analytical framework, the paper distinguishes customer-based reliability indices from energy-based measures such as Energy Not Supplied (ENS) and Expected Energy Not Served (EENS). It also clarifies the role of adequacy metrics, including Loss of Load Probability (LOLP) and Loss of Load Expectation (LOLE), and microgrid-oriented indicators such as Loss of Power Supply (LPS) and Loss of Power Supply Probability (LPSP). The review emphasizes that probability- or duration-based indices cannot be directly converted into monetary losses unless they are first expressed as energy-not-served quantities. Evidence from major events, including India 2012, North America 2003, Italy 2003, Türkiye 2015, Texas 2021, Iberia 2025, and Chile 2025, shows that outage consequences depend on the interaction between technical failure mechanisms, interruption duration, affected sectors, restoration processes, and infrastructure interdependencies. The study concludes that future outage-cost assessments should rely on transparent data reliability levels, updated sectoral cost data, dynamic VoLL estimates, and dimensionally consistent links between reliability indicators and economic losses.
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 192-202
Model Predictive Control of Doubly Fed Induction Generator (DFIG) Based on Transfer Function
The worldwide need for environmentally friendly and sustainable energy sources is continuously growing and has intensified research efforts toward wind power generation. Among the various generator technologies used in wind energy systems, asynchronous (induction) machines are highly favored due to their mechanical robustness, economic feasibility, and reliable operational characteristics. In particular, the Doubly Fed Induction Generator (DFIG) is extensively employed in variable-speed wind turbines owing to enables flexible power regulation and efficient energy conversion.Accordingly, this research focuses on developing a Model Predictive Control (MPC) scheme derived from a transfer function framework to upgrade operational behavior of DFIG system. The controller design is supported by comprehensive mathematical modeling and simulation analysis to achieve improved dynamic performance and system stability. To achieve this objective, a comprehensive theoretical analysis of DFIG has carried out. MPC based on Transfer Function has been designed, to examine the effectiveness of the proposed technique, a model has been developed using MATLAB/Simulink environment. As indicated by the simulation results, It is evident that transient state has been reduced (about 19.78%), the proposed strategy has reduced fluctuation of speed (165.1-164.9 = 0.2 rad/sec) that means maximum error of speed equal to 0.12%, Vbus has been stabilized at the desired level (1150 v), therefore indicating that proposed strategy has improvements in dynamic response of system.the proposed strategy has reduced the ripple of current for d-q axis ,in addition to achieve Q regulation by managing DC-link voltage level.
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 192-202
Model Predictive Control of Doubly Fed Induction Generator (DFIG) Based on Transfer Function
The worldwide need for environmentally friendly and sustainable energy sources is continuously growing and has intensified research efforts toward wind power generation. Among the various generator technologies used in wind energy systems, asynchronous (induction) machines are highly favored due to their mechanical robustness, economic feasibility, and reliable operational characteristics. In particular, the Doubly Fed Induction Generator (DFIG) is extensively employed in variable-speed wind turbines owing to enables flexible power regulation and efficient energy conversion.Accordingly, this research focuses on developing a Model Predictive Control (MPC) scheme derived from a transfer function framework to upgrade operational behavior of DFIG system. The controller design is supported by comprehensive mathematical modeling and simulation analysis to achieve improved dynamic performance and system stability. To achieve this objective, a comprehensive theoretical analysis of DFIG has carried out. MPC based on Transfer Function has been designed, to examine the effectiveness of the proposed technique, a model has been developed using MATLAB/Simulink environment. As indicated by the simulation results, It is evident that transient state has been reduced (about 19.78%), the proposed strategy has reduced fluctuation of speed (165.1-164.9 = 0.2 rad/sec) that means maximum error of speed equal to 0.12%, Vbus has been stabilized at the desired level (1150 v), therefore indicating that proposed strategy has improvements in dynamic response of system.the proposed strategy has reduced the ripple of current for d-q axis ,in addition to achieve Q regulation by managing DC-link voltage level.
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 167-177
Dynamic Line Rating Forecasting under False Data Injection Attacks Using Hybrid GRU–ELM Model with Hyperband Optimization
Dynamic Line Rating (DLR) forecasting enhances the operational flexibility and safety of overhead transmission lines by adapting ampacity to real-time environmental conditions. However, DLR prediction can be degraded by False Data Injection Attacks (FDIA) that corrupt inputs and threaten secure grid operation. This study presents a cyber-resilient DLR forecasting framework that combines a hybrid Gated Recurrent Unit–Extreme Learning Machine (GRU–ELM) architecture with Hyperband (HB)-based hyperparameter optimization. The proposed GRU–ELM/w HB model is evaluated under clean data and FDIA meteorological input conditions. Its performance is compared against SVM, ELM, LSTM, BiLSTM and GRU using MAE, RMSE, and R2. The proposed GRU-ELM/w HB model achieved substantial performance gains over all individual baseline methods. Although R2 drops sharply for the competing baselines under adversarial perturbations, the proposed model remains highly stable, sustaining R2 above 0.99 in the FDIA case. Compared with the standalone baselines methods, GRU– ELM w/HB reduces the RMSE by 21.57–82.34% under clean conditions and by 70.95–82.42% under FDIA. These results demonstrate that Hyperband-optimized GRU–ELM delivers accurate and FDIA-resilient DLR forecasts, maintaining stable performance under adversarial data conditions.
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 167-177
Dynamic Line Rating Forecasting under False Data Injection Attacks Using Hybrid GRU–ELM Model with Hyperband Optimization
Dynamic Line Rating (DLR) forecasting enhances the operational flexibility and safety of overhead transmission lines by adapting ampacity to real-time environmental conditions. However, DLR prediction can be degraded by False Data Injection Attacks (FDIA) that corrupt inputs and threaten secure grid operation. This study presents a cyber-resilient DLR forecasting framework that combines a hybrid Gated Recurrent Unit–Extreme Learning Machine (GRU–ELM) architecture with Hyperband (HB)-based hyperparameter optimization. The proposed GRU–ELM/w HB model is evaluated under clean data and FDIA meteorological input conditions. Its performance is compared against SVM, ELM, LSTM, BiLSTM and GRU using MAE, RMSE, and R2. The proposed GRU-ELM/w HB model achieved substantial performance gains over all individual baseline methods. Although R2 drops sharply for the competing baselines under adversarial perturbations, the proposed model remains highly stable, sustaining R2 above 0.99 in the FDIA case. Compared with the standalone baselines methods, GRU– ELM w/HB reduces the RMSE by 21.57–82.34% under clean conditions and by 70.95–82.42% under FDIA. These results demonstrate that Hyperband-optimized GRU–ELM delivers accurate and FDIA-resilient DLR forecasts, maintaining stable performance under adversarial data conditions.
- 24 June 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (2) , 132-142
Interpretable Machine Learning for Wind Power Forecasting: A Decision Support Framework with Hybrid ARIMAX Residuals
The integration of wind energy into power grids requires reliable and efficient decision support tools. While complex machine learning models are prevalent for wind power forecasting, their black-box nature and susceptibility to temporal overfitting can limit their operational utility. This study introduces a decision support framework for 10-minute-ahead wind power forecasting. Unlike many prior studies, the framework deliberately retains negative power values to represent turbine idle and auxiliary consumption states. It also applies strict chronological data partitioning to prevent temporal leakage. The framework further employs a novel hybrid feature engineering strategy, incorporating the residuals from the autoregressive integrated moving average with exogenous variables (ARIMAX) model to capture latent temporal structure in the data. The proposed framework evaluates machine learning algorithms—multiple linear regression (MLR), ARIMAX, decision tree, random forest, and extreme gradient boosting. Empirical results from the supervisory control and data acquisition (SCADA) benchmark dataset indicate that the interpretable MLR model consistently outperforms complex tree-based ensemble models on unseen data. Integrating a lagged dependent variable into the MLR model further captures previously unmodeled temporal dependence, reducing the test root mean squared error by 45% (from 361.0 to 200.0) and increasing the coefficient of determination by 5%, outperforming benchmark models reported in the literature for this dataset. The findings suggest that prioritizing statistical transparency, temporal validation, and physically consistent data preprocessing leads to an operationally reliable decision support tool. The proposed framework supports grid operators in improving turbine operational planning.
- 24 June 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (2) , 132-142
Interpretable Machine Learning for Wind Power Forecasting: A Decision Support Framework with Hybrid ARIMAX Residuals
The integration of wind energy into power grids requires reliable and efficient decision support tools. While complex machine learning models are prevalent for wind power forecasting, their black-box nature and susceptibility to temporal overfitting can limit their operational utility. This study introduces a decision support framework for 10-minute-ahead wind power forecasting. Unlike many prior studies, the framework deliberately retains negative power values to represent turbine idle and auxiliary consumption states. It also applies strict chronological data partitioning to prevent temporal leakage. The framework further employs a novel hybrid feature engineering strategy, incorporating the residuals from the autoregressive integrated moving average with exogenous variables (ARIMAX) model to capture latent temporal structure in the data. The proposed framework evaluates machine learning algorithms—multiple linear regression (MLR), ARIMAX, decision tree, random forest, and extreme gradient boosting. Empirical results from the supervisory control and data acquisition (SCADA) benchmark dataset indicate that the interpretable MLR model consistently outperforms complex tree-based ensemble models on unseen data. Integrating a lagged dependent variable into the MLR model further captures previously unmodeled temporal dependence, reducing the test root mean squared error by 45% (from 361.0 to 200.0) and increasing the coefficient of determination by 5%, outperforming benchmark models reported in the literature for this dataset. The findings suggest that prioritizing statistical transparency, temporal validation, and physically consistent data preprocessing leads to an operationally reliable decision support tool. The proposed framework supports grid operators in improving turbine operational planning.