Jurnal Media Elektrik

Published by Fakultas Teknik, Universitas Negeri Makassar

Abbrev: J. Media Elektr.
ISSN 1907-1728EISSN 2721-9100
Database Coverage
  • Scilit
Journal Articles
All-time journal articles
289
2025 journal articles
34
Subject
  • Power Systems & Electric Vehicles
  • Energy Systems & Technologies
  • AI & Machine Learning
  • Computer Vision & Graphics
  • Remote Learning & Research
  • Cybersecurity

Publications Analysis

Publications in 2016-2026
Open Access Publications in 2016-2026
Top Subjects

Publications in 2016-2026.

SubjectPublications
Power Systems & Electric Vehicles
21
AI & Machine Learning
20
Energy Systems & Technologies
18
Remote Learning & Research
17
Software Design
13
Computer Vision & Graphics
12
Human-Machine Interaction
9
Education & Pedagogy
8
Cybersecurity
8
Control & Automation Engineering
7

Top Countries

Publications in 2016-2026.

CountryPublications
Indonesia
145
Singapore
1
Saudi Arabia
1
Malaysia
1
China
1
Netherlands
1
Bangladesh
1
Iraq
1

Citation analysis
Publications published in 2023-2024 and cited in 2025.
Total Citations
26
Total Publications
94
Average Citations
0.28
Cited Publications
21
Cited Publications %
22.3%
Self Citations
1
Self Citations %
3.8%

Metrics
2025 Integrated Impact Indicators
I3
34
I3/N
1.17
h5_index
4
Monthly Citation Metric (MCM)
0.08

Monthly Citation Metric

Citations per year
All citations in 2016-2026

Citation Distribution
All citations to publications in 2023-2024.
Q1
0
Med
0
Q3
1
99%
5
Max
5

Citation Origins
Publications published in 2023-2024 and cited in 2025.
Citing Source Titles
Citing Publishers

Latest Publications

  • Open Access

    Evaluation And Improvement of the Grounding System to Reduce Grounding Resistance Using ETAP in a Retail Warehouse

    by Muh. Aditya Fathur Rahman, Asminar Asminar, Abdul Djohar, Tambi Tambi, Yuni Aryani Koedoes, Adhi Setiawan Samsul

    The grounding system is a critical component of an electrical installation because it diverts fault currents to the ground and limits potentially hazardous voltages. This study aimed to evaluate the condition of the existing grounding system in a retail warehouse, analyze the initial effectiveness of a mixture of limonite, wood charcoal, and gypsum as a soil treatment material, and evaluate a recommended grounding design using ETAP. This study employed a quantitative approach through field experiments and simulations. Grounding resistance was measured using an Earth Tester with the three-point method. Five grounding points were treated with a mixture of 2 kg per point, consisting of 40% limonite, 30% wood charcoal, and 30% gypsum. Preliminary results showed an average resistance of 10.46 Ω across the five points. After treatment, the average resistance decreased to 2.23 Ω with an initial effectiveness of 78.68%, and all treated points were below 5 Ω. In the ETAP simulation of the PLN power source, Grounding 1 produced an Rg of 3.295 Ω, GPR of 2,871.8 V, touch voltage of 1,256.1 V, and step voltage of 422.4 V. The touch voltage still exceeded the tolerance limit of 1,141.4 V. Grounding 2 reduced Rg to 1.860 Ω, GPR to 1,621.0 V, touch voltage to 648.3 V, and step voltage to 219.8 V. These results indicate that the grounding treatment effectively reduced the resistance under the test conditions, whereas Grounding 2 improved the safety of the grounding system in the PLN power source simulation scenario. Keywords: grounding system, grounding resistance, soil treatment, ETAP, touch voltage.

  • Open Access

    Comparative Forecasting of Antam Gold Prices Using LSTM, GRU, and Hybrid LSTM–GRU with Adam and SGD Optimizers

    by Yuris Alkhalifi

    People commonly invest in gold to protect their assets because of its role as a stable, safe-haven asset against economic volatility. However, the uncertainty of future gold price movements creates challenges, making the ability to predict gold prices beneficial for analysis. This study proposes a comparative approach to forecasting PT Antam's gold prices, evaluating the performance of three architectures: Long Short-Term Memory (LSTM), Gated Recurrent Unit (GRU), and Hybrid LSTM-GRU. The study uses historical daily price data from 2010 to early 2025, chronologically split into 80% training and 20% testing sets. Data is processed through a 60-day sliding window framework, and recursive multi-step forecasting is applied for a 30-day horizon. Two optimization techniques, Adam and Stochastic Gradient Descent (SGD), are evaluated. The experimental results show that the Hybrid LSTM-GRU model with Adam optimization achieved the best performance among the evaluated configurations, evidenced by an R-Squared (R²) value of 0.9972, a Mean Square Error (MSE) of 9.553542e+07, and a Root Mean Square Error (RMSE) of 9,774.22. An RMSE of 9,774.22 indicates that the standard deviation of the prediction errors is approximately IDR 9,774. When contextualized with the latest actual gold price, this yields an error ratio of 0.64%. The 30-day projection indicates a downward trend in prices until the end of January 2025. However, due to the univariate nature of the model, it should be viewed as a supplementary analytical tool rather than a sole basis for financial decision-making.

  • Open Access

    Development of an ESP32-Based Flood Monitoring and Early Warning System Using HC-SR04

    by Hilda Ashari, Dessy Ana Laila Sari

    This study aims to develop and implement an ESP32-based flood monitoring and early warning system capable of monitoring water level changes in real time. The system utilizes an HC-SR04 ultrasonic sensor to measure water levels, an OLED display for data visualization, and a buzzer along with smartphone notifications through Alarm Manager as early warning mechanisms. The research employed an experimental method consisting of hardware and software design, system programming using Arduino IDE, and performance testing using an aquarium model with water level variations ranging from 0 to 21 cm and an initial sensor to water surface distance of 5 cm. Water levels were classified into three conditions: Safe (19-21 cm), Warning (15-18 cm and 11-14 cm), and Danger (7-10 cm and 0-6 cm). The experimental results demonstrate that the ultrasonic sensor was able to detect water level changes consistently and reliably. Although an average measurement difference of 4,92 cm was observed compared to manual measurements, this discrepancy can be minimized through software calibration. Furthermore, the integrated warning system, consisting of a buzzer and smartphone notifications, performed effectively, with warning and danger alerts being delivered approximately one second after water level changes were detected. These findings indicate that the proposed system is capable of monitoring water levels and providing automatic real-time flood early warnings, making it a promising solution for flood risk mitigation and disaster preparedness.

  • Open Access

    IoT-Based Tele-ECG Systems: A Systematic Review of Architecture, Signal Quality, and Transmission Reliability

    by Rahma Ajeng Puspitasari, Dio Alif Pradana, Agoes Santika Hyperastuty

    Objective: Cardiovascular disease remains the leading cause of death worldwide, and early arrhythmia detection through electrocardiography (ECG) is critical; however, access to conventional ECG equipment at primary healthcare facilities remains limited. Portable Internet of Things (IoT)-based tele-electrocardiography (tele-ECG) systems have been proposed to close this gap; however, evidence on their architecture, signal quality, and transmission reliability remains scattered, with no integrated synthesis available. This review maps IoT-based Tele-ECG architecture, signal quality methods, and transmission reliability challenges, identifying gaps relative to prior scoping reviews on wearable and home-use ECG devices. Method: A Systematic Literature Review was conducted following PRISMA, searching Scopus and IEEE Xplore on 9 July 2026. Three independent reviewers screened the records and assessed full-text eligibility, with study quality appraised using the Mixed Methods Appraisal Tool. From 55 initial records, 31 studies (2020–2026) met the full-text verified inclusion criteria. Results: Low-cost architectures were dominated by AD8232/AD823X/MAX30003 sensors paired with ESP32/ESP8266/ STM32/nRF-series microcontrollers (48.4% of studies), which transmitted data via Bluetooth Low Energy, Wi-Fi, or cloud platforms. Signal quality evaluation relies on Signal Quality Index metrics or deep learning classifiers (29.0%), while reported challenges span latency, packet loss, power consumption, and data security. Novelty: Unlike prior reviews addressing device technology or clinical validation separately, this review is the first to jointly synthesize architecture, signal quality, and transmission reliability evidence for IoT-based Tele-ECG systems, revealing that no study has evaluated all three dimensions within one integrated protocol under realistic, resource-limited network conditions, which is a gap with direct implications for future low-cost Tele-ECG system design and validation.

  • Open Access

    Usability, Motivation, and Acceptance in Web- and AR-Based English Pronunciation Learning: A PLS-SEM TAM–SDT Approach

    by Zelli Ghea Mardi Anugrah, Hadziq Fabroyir

    This study evaluates user acceptance and motivation in English pronunciation learning across web-based and Augmented Reality (AR) platforms Utilizing a comparative design with a sample of 46 students, a web application (developed with Laravel and Livewire) and an AR application (developed with Unity and Vuforia) were constructed, both integrating the SpeechAce API for real-time pronunciation feedback Usability was measured using the System Usability Scale (SUS), while structural associations between technology acceptance and intrinsic motivation variables were evaluated using Partial Least Squares Structural Equation Modeling (PLS-SEM). Both systems demonstrated excellent usability, yielding average SUS scores of 93.33 for the Web platform and 83.54 for the AR platform. Due to initial instrument instability and construct invalidity in the original measurement model, post-hoc model reconstruction was performed, rendering this structural analysis exploratory in nature. In the reconstructed model, Intrinsic Motivation (IM) exhibited a strong, positive structural association with Perceived Ease of Use (PEOU) across both platforms. However, the association between IM and Perceived Usefulness (PU) was significant only on the AR platform. Conversely, the association between PEOU and PU was significant only on the Web platform. On both platforms, Attitude Toward Using (ATU) was primarily driven by PEOU rather than PU, which had no direct significant association with ATU. These exploratory findings suggest that integrating immersive features in AR can align learners’ subjective enjoyment with their perception of functional utility. This highlights the potential of learner-centered design to enhance engagement in digital pronunciation tools.

  • Open Access

    Grid-Connected Solar PV Optimization for Lighting Systems: A Case Study at a Tropical Campus Building in Indonesia

    by Firdaus Firdaus, Mudarris Mudarris

    In an effort to reduce dependence on fossil fuels and increase the use of renewable energy, this study examines the optimization of lighting for the Dean's Building at the Faculty of Engineering, Makassar State University (UNM) using solar panels as the primary energy source. This study includes calculating energy needs, designing an on-grid solar panel system, and analyzing the efficiency and effectiveness of its implementation. Based on observational data, the building's total electricity load reached 2,543 kW with an estimated daily usage of 11.25 kWh. Using the HOMER simulation, an optimal design for a solar power system with a capacity of 6.18 kW was obtained. This system consists of 20 units of Canadian PV modules, two BAE PVS batteries with a capacity of 1.4 kWh, and a SolaX X3 inverter with a capacity of 5 kW. Simulation results indicate that this system can meet lighting demands efficiently, producing 10,749 kWh annually with a PV capacity factor of 19.9%, while reducing operational costs by over IDR 3 million annually and contributing to carbon emission reduction. The implementation of this system also demonstrated a reduction in operational costs and a significant contribution to the reduction of carbon emissions, making it an efficient and sustainable solution for lighting academic buildings.

  • Open Access

    Development of an Augmented Reality and AI-Based SIBI Recognition Application for Deaf Students at a Special School

    by Taufik Bahtiar, Haripuddin Haripuddin, Hasrul Bakri, Ahmad Aiman Sanjaya

    This study aimed to develop and evaluate an Android-based learning application that integrates Augmented Reality (AR) and artificial intelligence to support Indonesian Sign Language System (SIBI) learning for deaf students. The study employed the Research and Development (R&D) method using the Four-D (4D) model consisting of Define, Design, Develop, and Disseminate stages. The gesture recognition module combined MediaPipe for hand landmark detection with MobileNetV2 for gesture classification, achieving an approximate recognition accuracy of 89 %. The model was trained using 80% of the training data and 20% of the testing data. Expert validation involved two content experts and two media experts, while practicality testing involved 12 respondents (nine deaf students and three teachers). Effectiveness was evaluated using a one-group pretest-posttest design involving nine deaf students across four learning sessions. Data were collected through observations, interviews, documentation, questionnaires, and learning achievement assessments. The developed application obtained an overall expert validation score of 4.67 (Very Valid). The software quality evaluation based on the selected ISO/IEC 25010 characteristics showed 100% functional suitability, 80% portability, and 100% compatibility. The practicality testing produced an average score of 4.63 (Very Practical). The effectiveness evaluation indicated a significant improvement in learning outcomes (p = 0.001), with a moderate N-gain (0.56) and 77.78% classical learning mastery. These findings indicate that the developed application is valid, practical, and capable of supporting SIBI learning in preliminary classroom implementation. Nevertheless, the findings should be interpreted within the scope of a limited trial involving a small sample size and the absence of a control group.

  • Open Access

    Development and Evaluation of an Indonesian Thesis-Title Similarity Detection System Using Hybrid TF-IDF–SBERT Retrieval and LightGBM Reranking

    by Abdul Ma'ARief Al Imran, Mursyid Ardiansyah, Ali Asgar Zainal Abidin

    This study developed and evaluated an Indonesian thesis-title similarity detection system to support the early screening of potentially similar research titles. The reference corpus consisted of 28,117 unique thesis titles collected from a publicly accessible institutional repository. The system integrates TF-IDF-based lexical retrieval, SBERT-based semantic retrieval, Union Top-K candidate selection, and machine learning reranking. Logistic Regression, XGBoost, and LightGBM were trained using threshold-derived pseudo-labels, while the final model performance was evaluated on an independent human-validated dataset constructed from a title-disjoint evaluation partition. A total of 900 candidate title pairs were independently assessed by two academic validators, achieving a Cohen’s kappa of 0.877. LightGBM achieved the best performance, with an accuracy of 94.67% and a macro F1-score of 0.9467. ISO/IEC 25010 evaluation showed a 100% functional pass rate, an 84.17% usability score, performance scores of 92.3% on mobile and 96.8% on desktop, while the automated security assessment categorized the staging deployment as Fairly Secure with two medium-risk findings. The system can support academic title-similarity screening; however, its generalizability remains limited by the use of a single-institution corpus and requires further multi-institutional validation.

  • Open Access

    Multi-Trajectory Performance and Run-to-Run Consistency of GWO-Tuned PID Control for a Differential-Drive Mobile Robot

    by Auliya Nabila, Agung Muhamad Toha

    Accurate trajectory tracking of differential-drive mobile robots is strongly influenced by proportional–integral–derivative (PID) controller parameters, while a single fixed parameter set may exhibit different performance across trajectories with distinct geometric characteristics. This study investigates the multi-trajectory performance and run-to-run consistency of Grey Wolf Optimizer (GWO)-based PID tuning for a differential-drive mobile robot. A kinematic robot model with linear and angular-velocity PID control is evaluated on four reference trajectories: circle, lemniscate, square, and S-curve. A systematically tuned fixed PID controller is employed as the common baseline, while GWO independently optimizes six PID gains for each trajectory using an objective function combining the integral of time-weighted absolute error (ITAE) and control effort. To account for the stochastic nature of GWO, 30 independent optimization runs are performed for each trajectory and performance is assessed using root mean square error (RMSE), ITAE, standard deviation, median, interquartile range, and coefficient of variation. The simulation results show that GWO-PID reduces the mean RMSE from 0.07767 to 0.04979 m for the circle, from 0.08113 to 0.06393 m for the lemniscate, and from 0.09047 to 0.05095 m for the S-curve, corresponding to improvements of 35.90%, 21.20%, and 43.68%, respectively. The square trajectory exhibits an increase in mean RMSE from 0.07728 to 0.08154 m, indicating that optimization does not provide uniform improvement across all trajectory geometries. Run-to-run analysis further reveals substantial differences in optimization consistency with RMSE coefficients of variation of 54.17% for the circle, 85.33% for the lemniscate, and 12.03% for the square, and 0.75% for S-curve. These findings indicate that the effectiveness and repeatability of GWO-based PID tuning are trajectory-dependent, highlighting the importance of multi-run statistical evaluation when assessing metaheuristic controller tuning for mobile robot trajectory tracking.

  • Open Access

    Increasing the Resistance of the Grounding System in the Electrical Engineering Building of the Fakfak State Polytehnic Using Parallel Copper Rods and Additional Materials

    by Naomi Lembang, Herman Hr, Rusliadi Rusliadi, Arif Aminullah, Yulianto La Elo

    T he grounding system is an important component in electrical installations that ensures human safety, protects electrical equipment, and maintains the reliability of the electrical power distribution system. The condition of the grounding system in the Electrical Engineering Building of Fakfak State Polytechnic is still not optimal because the grounding resistance value obtained is relatively high. The grounding resistance value that exceeds the standard can reduce the effectiveness of the grounding system, thereby increasing the risk of interference, equipment damage, and danger of electric shock. This study aimed to analyze the existing condition of the grounding system and evaluate improvement efforts to improve the safety and reliability of electrical installations in the building. The research method used was a quantitative method with an experimental approach through measuring the grounding resistance before and after the improvement. Measurements were carried out using the three-point method with an Earth Tester measuring instrument to obtain accurate soil resistance values. Improvement efforts were made by adding two copper electrodes and utilizing additives in the form of a mixture of bentonite, salt, and charcoal around the electrodes to increase soil conductivity. The initial measurement results showed a grounding resistance value of 10.67 Ω, which still exceeded the maximum limit based on PUIL 2011, which is ≤ 5 Ω for general installations. After the repairs, the grounding resistance value decreased to 6.96 Ω, a decrease of approximately 34.8% from the initial condition. Although these results do not fully meet the 2011 PUIL standards, this study proves that the addition of electrodes and the use of additives can significantly increase the effectiveness of the grounding system. The results of this study are expected to serve as a reference in efforts to improve the quality of grounding systems in educational buildings and similar electrical installations.