Database Coverage
  • Scilit
  • DOAJ
Journal Articles
All-time journal articles
210
2025 journal articles
51
Subject
  • Concrete

Publications Analysis

Publications in 2016-2026
Open Access Publications in 2016-2026
Top Subjects

Publications in 2016-2026.

SubjectPublications
Concrete
92
Manufacturing
29
Sustainability Studies
23
Mechanics
19
Reliability Engineering
16
Human Geography
15
Geotechnical Engineering
15
Social Justice & Reform
14
Art
12
Asphalt
10

Top Countries

Publications in 2016-2026.

CountryPublications
Ukraine
31

Citation analysis
Publications published in 2023-2024 and cited in 2025.
Total Citations
14
Total Publications
99
Average Citations
0.14
Cited Publications
11
Cited Publications %
11.1%
Self Citations
0
Self Citations %
0%

Metrics
2025 Integrated Impact Indicators
I3
12
I3/N
0.86
h5_index
3
Monthly Citation Metric (MCM)
0.14

Monthly Citation Metric

Citations per year
All citations in 2016-2026

Citation Distribution
All citations to publications in 2023-2024.
Q1
0
Med
0
Q3
0
99%
4
Max
5

Citation Origins
Publications published in 2023-2024 and cited in 2025.
Citing Source Titles
Citing Publishers

Latest Publications

  • Open Access

    LOW-CARBON MODIFIED POZZOLANIC CEMENT FOR CONCRETE OF MASSIVE STRUCTURES

    by M.A. Sanytsky, O.R. Kotsii, I.M. Hevyuk, R.O. Kolodrub

    The possibility of using low-carbon modified sulfate-resistant pozzolanic cement for concretes of massive structures has been shown. It is established that pozzolanic cement CEM IV/B(P-V) 32.5 R-SR produced by PJSC "Ivano-Frankivskcement" provides a sufficiently high standard compressive strength (46.0 MPa) with a lower heat of hydration (254.1 J/g) compared to slag cement CEM III/A (267.7 J/g); in this case the specific carbon dioxide emission is 362 kg/t. The influence of organic-mineral additives of various types on the physical and mechanical characteristics of low-carbon pozzolanic cements and their heat release kinetics has been investigated. Modification of pozzolanic cement with an organo-mineral additive contributes to increasing the flowability of the mortar mixture and increasing the standard strength to 50.0 MPa, while the temperature maximum during the hydration process is shifted by 80 min. Modified pozzolanic cement provides a decrease in the W/C ratio of the concrete mixture and an increase in the compressive strength of concrete at the age of 28 days from 35.1 to 40.7 MPa; at the same time, reduced heat release contributes to limiting temperature gradients and the risk of thermal cracks in the concrete of massive structures. For concrete based on modified pozzolanic cement, the carbon footprint is 123.1 kg CO₂/m³ of concrete, while the CO₂ intensity is 3.0 kg CO₂/(m³·MPa), and the clinker intensity is 3.6 kg clinker/(m³·MPa). It is established that for concrete of class C25/30, the maximum temperature value T=33.9°C is reached 18 h after mixing the mixture. The obtained results confirm the prospects of using modified pozzolanic cement with a low heat of hydration of the CEM IV/B(P-V) type for producing low-carbon concretes of massive structures.

  • Open Access

    MODEL AND RESULTS OF SCIENTIFIC AND TECHNICAL SUPPORT FOR REPAIR AND RESTORATION WORKS AT THE MONUMENT OF URBAN PLANNING AND ARCHITECTURE THE RUSOV HOUSE IN ODESA

    by A.V. Kovrov, K.I. Anisimov, D.I. Yakushev, B.M. Panov

    The house of the Odesa entrepreneur A. Rusov is one of the dominant architectural features of the historic development in the central part of the city. The main causes that led to the deterioration and partial loss of individual elements of the building include: reconstruction and alterations to the internal layout, fires, the absence of major and routine repairs, differential settlement, and other factors. As a result of fire exposure and fire suppression activities, the building was left virtually without its principal stiffness elements ‒ the floor diaphragms ‒ which, in turn, resulted in a hazardous unsupported height of the remaining walls. The above factors contributed to the structural fragmentation of the building into separate sections. In 2018-2019, a sequential model of scientific and technical support was implemented during the repair and restoration works at the Rusov House in order to ensure its load-bearing capacity and durability while preserving its authenticity. One of the areas of scientific and technical support during the repair and restoration works involved monitoring the condition of Group "A" building structures based on the results of numerical modelling and dynamic surveys. Verification of the computational model was performed by comparing the frequencies of the lower natural vibration modes obtained from modal analysis with those measured directly in situ on the actual structure. During the foundation strengthening works, a decrease in the natural frequencies (an increase in the periods) of the first natural vibration modes was observed at the monitored points, without changes in their mode shapes, indicating a reduction in the stiffness of the structural elements while the mass values and structural geometry remained unchanged. As the restoration of the floor structures acting as rigid diaphragms progressed, a "convergence" of the measured values was observed, indicating the development of integrated structural behaviour among the building sections being connected. Based on the monitoring results and analysis of the computational models, recommendations were developed for adjusting the design solutions for the floor structures. Their implementation improved the structural efficiency of these elements.

  • Open Access

    TECHNOLOGICAL JUSTIFICATION OF OPERATING PARAMETERS OF A SEQUENCING BATCH REACTOR WITH EXPANDED POLYSTYRENE FLOATING CARRIERS FOR DAIRY WASTEWATER TREATMENT

    by I.V. Kobylko

    The paper presents the results of a numerical investigation of the design parameters of a sequencing batch reactor (SBR) with expanded polystyrene (ePS) floating carriers for dairy wastewater treatment. Dairy-plant wastewater is a highly-concentrated, carbon-rich flow (ratio of chemical oxygen demand to total nitrogen COD/N_tot ≈ 90), so denitrification in it is not carbon-limited; the bottleneck of the classical spatially-separated denitrification–nitrification scheme is its energy intensity — the need for a separate anoxic reactor, nitrate recirculation and a high dissolved-oxygen level. The goal of the work is to substantiate the operating ranges of the design parameters and to assess the economic feasibility of the proposed solution. The methodology is based on the ASM3_2N mathematical model with a lumped biofilm description (Wanner et al.), implemented in Python (NumPy, SciPy) and calibrated on laboratory data. Series of numerical experiments were carried out to evaluate the influence of the dissolved-oxygen concentration (DO), the volumetric fraction of the floating carrier (F) and the S_S/NH₄⁺-N ratio on the total-nitrogen removal efficiency. At the reference conditions (DO = 1.0 mg O₂/L; F = 30 % v/v) TN removal reaches 86.5 % for the carrier system against 76.0 % for the control reactor; the dependence on DO is non-monotonic, with an optimum at 1.0 mg/L (operating window 0.8–1.2). A two-dimensional operating window (DO × F) was constructed with efficiency levels of 70, 80 and 85 %. Design recommendations are formulated: operating DO 0.8–1.2 mg O₂/L; F = 25–35 %; minimum required S_S/NH₄⁺-N ≥ 5. A techno-economic assessment for a 300 m³/day treatment facility, using DP «Ruzhin-Moloko» (Zhytomyr region) as an example, shows a reduction of capital costs of about 15 %, of operating costs of about 32 %, and of the specific aeration energy of 37.5 %. The obtained estimates are the result of model-based prediction consistent with a laboratory experiment and require further industrial verification.

  • Open Access

    REHABILITATION INSTITUTIONS FOR MILITARY SERVANTS AND CIVILIAN POPULATION IN UKRAINE AND THE WORLD

    by I. Lynnyk, A. Simonova

    The creation of a modern rehabilitation system is a strategic priority of the state policy of Ukraine and a basic element of medical support for the Armed Forces of Ukraine, which directly affects the restoration of the country's labor and defense potential. The work systematizes the classification of rehabilitation institutions, which are divided into three main types: inpatient, outpatient and specialized. The main areas of their functioning are outlined: medical and physical, psychological, social and professional. Modern architectural and construction principles of their design are formulated: rational choice of location; environmental friendliness; ergonomics; energy efficiency; smart technologies; aesthetics; universal design and barrier-free design; safety. A comparative analysis of domestic and international experience was carried out, which allowed to identify systemic problems in the functioning of Ukrainian centers and determine promising vectors for their modernization in conditions of prolonged martial law. It was found that the domestic rehabilitation industry is in a rather difficult situation, largely due to prolonged hostilities. Currently, the network of centers is expanding due to the re-profiling of Soviet sanatoriums and recreation centers, which do not always meet modern standards. The situation is complicated by the outflow of qualified personnel abroad. The lack of budget funding limits the possibilities of implementing innovative technologies, purchasing robotic equipment and training personnel. In addition, ongoing hostilities and constant security risks restrain foreign direct investment in the construction of new facilities within the country. In Ukraine, there is a disproportion in the spatial location of institutions: most of them are concentrated in large cities, while in regions and small settlements such services remain inaccessible. In addition, there is a shortage of specialized military medicine centers, and the available equipment is often outdated. At the same time, in recent years, reforms have been intensified in Ukraine: the regulatory framework is being modernized, new standards of care are being created, and a state network of veteran hospitals is being deployed. The UN, the Red Cross, and other international institutions provide strong financial and methodological support.

  • Open Access

    INTERACTION OF BUILDING MATERIALS WITH AIR FLOWS IN PNEUMATIC CONVEYING AND ASPIRATION SYSTEMS

    by E.A. Geraskina, O.I. Khomenko, A.A. Khomenko

    The article examines the features of the interaction of flows of bulk building materials with air flows in pneumatic transport and aspiration systems of construction industry enterprises. The relevance of the study is due to the fact that the processes of receiving, transporting and overloading bulk materials are accompanied by intensive dust emission, which is largely determined by the nature of the interaction of material and air streams. In modern practice of designing receiving devices and aspiration systems, these processes are mostly considered separately, without taking into account their interconnection, which leads to a decrease in the efficiency of aspiration installations and deterioration of operating conditions of production equipment. Based on the conducted research, the kinematic patterns of the addition of air masses to flows of bulk materials during their gravitational movement in gravity pipelines were determined. Analytical dependencies were obtained for determining the ejection pressure, volumes and air velocities that arise in the process of transporting the material. It is shown that the magnitude of the ejection pressure and the volume of air moving through gravity pipelines depend on the geometric parameters of the pipelines, the physical and mechanical properties of the material, the mass flow rate and the degree of tightness of the system. The patterns of static pressure distribution along the transport elements are established and the conditions for the formation of zones of excess and reduced pressure that affect the processes of dust emission are determined. Based on the results obtained, a scientifically substantiated method for calculating the aerodynamic parameters of aspiration sampling is proposed, which takes into account the ejection properties of bulk materials and the conditions of their transportation in gravity pipelines and transfer units. The proposed approach allows you to determine the required volumes of aspiration air, evaluate the parameters of dust air flows and increase the efficiency of aspiration systems. The results of the study can be used in engineering calculations and design of dust removal and pneumatic transport systems at construction industry enterprises.

  • Open Access

    INFLUENCE OF GROUND BLAST-FURNACE SLAG ON THE PROPERTIES OF CEMENT-BASED COMPOSITIONS

    by K.O. Streltsov, I.V. Barabash, N.R. Antoniuk, D.O. Volynskyi

    In the production of blended mineral binders, one of the key challenges is establishing optimal proportions between Portland cement and a mineral addition. This article examines a blended binder produced by mixing Portland cement without mineral additions with ground blast-furnace slag dried to constant mass, with the slag content ranging from 0% to 35%. This binder meets the requirements of DSTU B V.2.7-46:2010, General-Purpose Cements. Specifications, and, according to its type and composition, is classified as Portland cement with slag. The article examines the effects of ground slag on the bulk density and true density, normal consistency, setting times, exothermic temperature rise, and compressive strength of hardened cement paste. The experimental results showed that incorporating up to 35% blast-furnace slag into Portland cement causes a slight decrease in the bulk density of the blended binder, as well as in true density, specific surface area, and the normal consistency of cement paste. With regard to the effect of ground blast-furnace slag content on the setting times of cement paste, increasing the slag content from 0% to 35% extends both setting times: the initial setting time increases from 3 h 20 min to 4 h 50 min, while the final setting time increases from 4 h 50 min to 7 h 10 min. Increasing the amount of ground blast-furnace slag in the blended binder reduces the exothermic temperature rise from 45.6 °C, in the absence of slag, to 31 °C when the binder contains 35% blast-furnace slag. The experimental results indicate that incorporating blast-furnace slag into Portland cement reduces the compressive strength of hardened cement paste at all tested curing ages. It should be noted that as the curing period increases from 3 to 28 days, the difference in strength between cement pastes made with cement without mineral additions and that made with cement containing 35% blast-furnace slag decreases. This indicates the high reactivity of the blast-furnace slag.

  • Open Access

    COMPARATIVE ANALYSIS OF THE THERMAL EFFICIENCY AND CARBON FOOTPRINT OF MODERN ENVELOPE MATERIALS

    by A. Myronchuk

    The modern construction sector remains one of the largest consumers of energy resources and a significant source of greenhouse gas emissions. Due to the increasing requirements for building energy efficiency and the need for decarbonization of the construction industry, the selection of envelope materials capable of providing not only high thermal protection but also minimal environmental impact throughout the entire life cycle has become especially relevant. Under current conditions, the assessment of materials can no longer be based solely on thermal conductivity, as approaches related to embodied carbon and operational emissions of buildings are becoming increasingly widespread. The purpose of this article is to provide a comparative assessment of the thermal efficiency and carbon footprint of modern envelope materials in order to determine their suitability for energy-efficient and low-carbon construction. The study analyzes mineral wool, polystyrene foam, aerated concrete, ceramic blocks, CLT structures, SIP panels, and bio-based materials. The research was carried out using comparative analysis, thermal engineering calculations, and the Life Cycle Assessment (LCA) methodology. The study considered thermal conductivity, thermal resistance, durability, embodied carbon levels, and the influence of materials on reducing the operational energy consumption of buildings. The regulatory framework of the study was based on the provisions of DBN V.2.6-31:2021 concerning the energy efficiency of buildings. The analysis revealed that the lowest thermal conductivity values are characteristic of polymer insulation materials and mineral wool, which provide a high level of thermal protection with relatively small layer thicknesses. At the same time, these materials differ significantly in terms of carbon impact due to the specifics of production processes and the origin of raw materials. It was determined that wood-based materials and biocomposites have the lowest carbon footprint because of the use of renewable raw materials and their ability to store biogenic carbon. Aerated concrete and ceramic blocks demonstrate stable durability and structural reliability; however, to meet modern thermal protection standards, they require combination with effective insulation materials. The results indicate that the assessment of envelope materials cannot be limited only to thermal conductivity. For example, an aerated concrete wall with an additional insulation layer may provide a better balance between thermal protection, durability, and fire safety than a single-layer structure. Similarly, CLT systems combined with bio-based insulation are characterized by lower embodied carbon levels but require additional moisture protection and careful detailing of joints and connections. It was established that the most balanced solution in terms of energy efficiency, durability, and environmental performance is represented by combined structural systems, particularly the combination of aerated concrete with mineral wool insulation. The obtained results confirm that the assessment of modern envelope materials should be based on a comprehensive approach that considers not only thermal properties but also carbon footprint, durability, reuses potential, and the impact of materials on the operational energy consumption of buildings. A promising direction for the development of energy-efficient construction is the implementation of low-carbon and bio-based materials combined with optimized structural solutions and modern approaches to the life cycle assessment of construction products.

  • Open Access

    DRY BUILDING MIXTURES BASED ON RECYCLED CONSTRUCTION WASTE PRODUCTS FOR THE RESTORATION OF BUILDINGS AND INFRASTRUCTURE

    by A.V. Bondar, L.V. Kucherenko, I.M. Babii, O.V. Bondar

    The paper investigates the potential use of recycled construction waste products in dry building mixtures intended for the restoration of buildings and infrastructure. The relevance of the study is determined by the considerable quantities of construction waste generated as a result of the demolition of obsolete structures, reconstruction of buildings, and destruction caused by military operations in Ukraine. The rational use of secondary mineral raw materials represents a promising approach to resource conservation, reduction of environmental impacts, and improvement of the efficiency of post-war reconstruction. The current state of construction waste recycling in the production of building materials is analysed. The potential application of fillers derived from crushed concrete, brick waste, waste glass, and crushed limestone by-products as components of dry building mixtures is considered. The physical and mechanical characteristics of the raw materials are presented, and a series of experimental compositions with different contents of secondary components is developed. The effect of the amount of recycled materials on the technological and performance properties of dry building mixtures is evaluated. It is established that an increase in the proportion of secondary components contributes to an improvement in the water-retention capacity of the mixtures and a reduction in their average density. At the same time, excessive amounts of recycled raw materials result in a decrease in the strength characteristics of the material. Based on the experimental results, optimal mixture compositions are determined, providing compressive strength of up to 29.5 MPa, flexural strength of up to 6.4 MPa, and adhesion strength of up to 0.86 MPa. The possibility of reducing cement consumption by up to 25% in the optimal compositions without a significant deterioration in the performance properties of the material is investigated. The obtained results confirm the feasibility of using the developed dry building mixtures for repair and restoration works, the construction of levelling layers, the repair of concrete and brick surfaces, as well as the restoration of residential, public, and engineering and transport infrastructure.

  • Open Access

    CAUSES OF ACCELERATED PHYSICAL DETERIORATION OF A REINFORCED CONCRETE EQUALIZATION TANK IN THE BUILDING OF LOCAL WASTEWATER TREATMENT FACILITIES OF A PHARMACEUTICAL ENTERPRISE

    by L.A. Tsyhanenko, V.M. Lutskovskyi, G.M. Tsyhanenko

    The article investigates the causes of accelerated physical deterioration of a reinforced concrete equalization tank in the building of local wastewater treatment facilities (LWTF) of a pharmaceutical enterprise. The study demonstrates that the degradation of concrete structures results from the combined effects of chemical, physicomechanical, biological, and operational factors. The operating features of the equalization tank, which provides the reception, temporary storage, and equalization of industrial wastewater with irregular inflow, are analyzed. The main factors affecting the durability of reinforced concrete structures are identified, including concrete chemical corrosion, reinforcement corrosion, biogenic sulfuric acid corrosion, cyclic hydrostatic loading, deterioration of protective coatings, and violations of the prescribed operating conditions. Based on the analysis of recent national and international studies, together with the results of an in-situ technical inspection, the most vulnerable areas of the equalization tank were identified. These include the variable water level zone, the wall-to-base slab joints, pipeline penetration areas, and the gas space above the wastewater surface. It was determined that the above-water zone exhibits damage to the surface layer of concrete, delamination of the protective waterproofing, condensation, and slimy deposits. Laboratory analysis of corrosion products confirmed the acidic nature of the environment and the presence of sulfate ions. The detected damage and operating conditions indicate the development of biogenic sulfuric acid corrosion associated with the formation of hydrogen sulfide and its subsequent oxidation in the gas space of the tank. The obtained results confirm the necessity of regular technical monitoring, timely restoration of anticorrosion protection, and the application of modern wastewater quality monitoring methods to ensure the reliable long-term operation of reinforced concrete equalization tanks at local wastewater treatment facilities of pharmaceutical enterprises.

  • Open Access

    THREE-FACTOR EXPERIMENTAL MATRIX AND LOW-CYCLE TESTING METHODOLOGY FOR CONCRETE BEAMS WITH WORKING GFRP REINFORCEMENT IN THE TENSION ZONE

    by Ye.V. Klymenko, O.I. Chyhin

    Published repeated-loading programmes for GFRP-reinforced flexural members remain methodologically heterogeneous with respect to cycle limits, number of repetitions, load normalisation, and monitored response variables, which limits direct comparison between datasets. The aim of this methodology paper is to develop and substantiate a formalised experimental programme for concrete beams with working longitudinal GFRP reinforcement in the tension zone under prescribed low-cycle loading regimes. The scientific result is the experimental procedure itself rather than quantitative results from the beam series. The programme comprises 15 specimens and three factors: working GFRP reinforcement level X₁, concrete strength class X₂, and prescribed low-cycle loading regime X₃. The matrix follows the geometric layout of a face-centred central composite design and comprises eight factorial corner points, six face-centred axial points, and one centre point. Reinforcement arrangements 3Ø8, 3Ø12, and 2Ø18 correspond to actual μf=Af/(bh) values of 0.503, 1.130, and 1.697%, while X₂ comprises C16/20, C20/25, and C25/30. X₃ is treated as an ordered composite regime because its levels simultaneously change Mmin, Mmax, mean moment, amplitude, and the load ratio R. Cyclic demand is normalised with respect to the a priori predicted laboratory ultimate flexural capacity Mu,pred, evaluated from strain compatibility and equilibrium of the normal section. Three regimes are prescribed: 0↔0.4Mu,pred, 0.4↔0.6Mu,pred, and 0.6↔0.8Mu,pred, each comprising ten cycles with 10-min holding periods at the upper and lower limits. Four-point bending is used with a 980 mm support span, a 415 mm shear span and a 150 mm constant-moment region; the bending moment is related to the total jack force by M=0.2075P. Instrumentation combines midspan deflection measurement, continuous concrete and GFRP strain acquisition at 62.5 Hz, and manual measurement of the maximum opening of a flexural crack. Predefined procedures are provided for averaging paired GFRP strain gauges, fitting the strain profile ε(y), calculating curvature and neutral-axis position, and evaluating cyclic secant stiffness. Because no identical factor combinations are replicated and only one centre point is available, the matrix is intended for direct comparisons, trend analysis, and exploratory modelling rather than a formal lack-of-fit assessment or a fully validated quadratic response surface. The methodological novelty lies in integrating the factor matrix, composite cyclic regimes, through-depth strain monitoring, and predefined interpretation rules within one protocol.