American Journal of Innovation in Science and Engineering

Published by E-palli

Abbrev: Am. J. Innov. Sci. Eng.
EISSN 2158-7205
Database Coverage
  • Scilit
Journal Articles
All-time journal articles
119
2025 journal articles
32
Subject
  • Multidisciplinary

Publications Analysis

Publications in 2016-2026
Open Access Publications in 2016-2026
Top Subjects

Publications in 2016-2026.

SubjectPublications
AI & Machine Learning
24
Cybersecurity
17
Sustainability Studies
10
Power Systems & Electric Vehicles
8
Climate Change
8
Concrete
6
Manufacturing
6
Energy Systems & Technologies
5
Telecommunications
5
Facilities Management
5

Top Countries

Publications in 2016-2026.

CountryPublications
Nigeria
22
Bangladesh
18
United States
16
Philippines
7
China
5
Kenya
5
India
5
Indonesia
4
Pakistan
3
France
2

Citation analysis
Publications published in 2023-2024 and cited in 2025.
Total Citations
32
Total Publications
40
Average Citations
0.80
Cited Publications
19
Cited Publications %
47.5%
Self Citations
4
Self Citations %
12.5%

Metrics
2025 Integrated Impact Indicators
I3
10
I3/N
0.56
h5_index
6
Monthly Citation Metric (MCM)
1.3

Monthly Citation Metric

Citations per year
All citations in 2016-2026

Citation Distribution
All citations to publications in 2023-2024.
Q1
0
Med
1
Q3
3
99%
8.6
Max
9

Citation Origins
Publications published in 2023-2024 and cited in 2025.
Citing Source Titles
Citing Publishers

Latest Publications

  • Open Access

    Autonomous Water Infrastructure Management for High-Demand Facilities: A Hierarchical AI Framework Integrating Physics-Informed Digital Twins and Risk-Sensitive Reinforcement Learning

    by Konstantin Korvyakov Korvyakov

    Municipal water distribution systems operating under conventional SCADA-based supervisory control lose between 28% and 35% of treated production volume before delivery to registered consumer meters, a failure rate attributable to static hydraulic model parameterization and decoupled subsystem architectures rather than to any fundamental physical constraint. This paper presents a unified framework coupling a continuously self-calibrating physics-informed digital twin, a hierarchical reinforcement learning controller decomposed via Lagrangian relaxation across three operational tiers, and a temporal fusion transformer whose probabilistic quantile outputs propagate directly into the controller’s risk-sensitive reward function. Evaluated on a 1,847-node, 312 km distribution network serving four hyperscale data center facilities over a 12-month period, the framework achieves a 33.3% reduction in non-revenue water loss, a 29.3% reduction in specific energy consumption, and a 90.7% reduction in pipe burst detection latency relative to the SCADA baseline operating on identical sensor and tariff infrastructure.

  • Open Access

    Hierarchical Shrinkage Baselines with Independent Absolute Thresholds for Context-Adaptive Evaluation of Commercial Driver Behavior

    by Bair Nurbaev

    A driver’s history serves as a reference for flagging unsafe behavior until it absorbs the behavior. Under a shrinkage profile with pseudo-count κ0 = 30 segments, the expected gap between the profile and a stable braking-composite mean of 2.82 (population mean 2.35) falls from 0.29 at 18 accumulated segments to 0.043 at 300, and the deviation test loses the signal. To prevent this degradation, the proposed architecture couples an empirical Bayes shrinkage baseline with an invariant absolute threshold, evaluating behavioral features against both individual history and safety envelopes simultaneously. A deviation triggers an alert whenever either baseline condition is met. This dual-layer hierarchy directly informs the composite safety and efficiency indices, governs directional conflict tests, and calibrates the automated feedback cadence based on observed driver responsiveness. In one simulated twelve-week fleet of 42 drivers, 36 vehicles and 36 context classes, the adaptive cadence ended 5.2% below a static cadence in mean Safety Behavior Index under a shared adaptive reference (23.8 against 25.1), and mean time headway met the conflict definition for 11 of 42 drivers. Every value describes the behavior of the model under the stated assumptions in one simulated realization and measures no effect in a physical fleet.

  • Open Access

    Carrier Safety Scoring Under Measurement Instability: From CSA Percentile Volatility to Route-Level Risk Allocation

    by Natalya Gennadyevna Orlova

    Carrier safety percentile scores generated by the Federal Motor Carrier Safety Administration’s Safety Measurement System inform enforcement prioritization, insurance underwriting, and, increasingly, automated freight-assignment decisions. Several independent strands of research document that these percentiles behave inconsistently for carriers with limited inspection histories. This article connects that documented inconsistency to a specific decision a route-level or lane-level risk-allocation system must make: whether to treat every published percentile with equal statistical confidence. Drawing together evidence on carrier size, inspection frequency, longitudinal score movement, and carrier-level aggregation, the article argues that a below-threshold CSA percentile carries a different statistical status than an above-threshold one, and proposes this distinction as a design requirement for automated routing systems that already handle other forms of scenario uncertainty. The article specifies the data, unit of observation, and modeling approach a future empirical study would need to test this claim, framing the present contribution as the conceptual groundwork for that test.

  • Open Access

    Performance Evaluation of Solar PV Systems Under Different Irradiance and Temperature Conditions

    by Md. Chand Ali Ali, Md Masud Rana, Md. Shala Uddin Sagar

    Solar photovoltaic systems are systems that function under varying environmental conditions and the field performance of a solar photovoltaic system is controlled mainly by the joint impact of the solar irradiance and the module temperature. This paper is a control physics-based performance analysis of a monocrystalline 5 kW grid-connected photovoltaic system at 200, 400, 600, 800 and 1000 W/m2 of irradiance levels and 15, 25, 35, 45 and 55o C of module-temperature levels. The number of observations was 300 because it was carried out using a full-factorial design containing twelve repeated observations in each condition. The model included irradiance-sensitive low-light performance, power temperature coefficient of -0.37%/o C, inverter conversion, balance-of-system losses, and minor stochastic deviations in measurements. AC output power, DC voltage, DC current, system efficiency and performance ratio were used as performance measurement parameters. The largest beneficial influence on output was exerted by irradiance, whereas rising temperature invariably decreased voltage and the power, efficiency and performance ratio. At 1000 W/m², mean AC output declined from approximately 4.98 kW at 15 °C to 4.23 kW at 55 °C. At 25 °C, output increased from about 0.91 kW at 200 W/m² to 4.80 kW at 1000 W/m². The analysis of variance (ANOVA) showed that there was an effect of irradiance, temperature, and a significant interaction effect. Conventionalized regression showed that the most significant predictor was irradiance, then temperature and the negative interaction between irradiance and temperature. The findings indicate that a high irradiance may not necessarily ensure maximum usable power in case thermal loading is extreme. The paper presents a reproducible operating envelope, quantitative sensitivity estimates, and implications to practical use in terms of array ventilation, inverter sizing, monitoring, and yield prediction.

  • Open Access

    Green Human Resource Management and Renewable Energy Adoption in Manufacturing Firms: The Mediating Role of Organisational Environmental Commitment

    by Fahim Ahmed

    To enable the use of renewable energy, organisational support is needed. This paper explores the connection between green human resource management and adoption of renewable energy in manufacturing companies in Bangladesh with organisational environmental commitment as an intermediary. It features 370 respondents and differentiates between green recruitment and selection, green training and development, and green performance management and rewards. PLS-SEM measures the measurement and structural models. According to bootstrap inference of this analysis, 10,000 valid replications are used. Each of the 7 hypotheses is supported. The coefficients of the environmental commitment are the highest with green training and development next, then there is green performance management, and rewards next and finally the green recruitment and selection. The adoption of renewable energy is positively linked with environmental commitment. The mediation of recruitment is complementary whereas training and performance management is indirect-only. The model accounts 27.96% and 29.35 % of the variation of environmental commitment and adoption respectively. The repeated cross-validation gives positive predictive relevance on all of the endogenous indicators and it reduces prediction errors as compared to the linear benchmark. The results place environmental commitment as an organisational process connecting practices that relate human resources and adoption of renewable energy. When using renewable energy to achieve renewable energy goals, manufacturing managers need to align capabilities of employees, environmental responsibility, and long-term management dedication. Cross-sectional relationships should be approached with care and further longitudinal studies are needed.

  • Open Access

    Passive Thermal Management of Battery Packs Using Agricultural-Waste-Derived Carbon-Supported Bio-Based Phase Change Materials: A Reduced-Order Design-Space Study

    by Tawhidul Islam, Samrat Hossen Akib

    The effectiveness of passive phase change material (PCM) buffering depends on whether heat can enter the latent reservoir throughout the duty time. PCM buffering can lower short-duration battery temperature rise without continuous auxiliary power. This study reframes an agricultural-waste-supported bio-based PCM concept as a reduced-order design-space analysis rather than an experimentally validated material ranking. A twelve-cell equivalent battery node is coupled to a PCM buffer through an effective conductance. The matrix is anchored to an experimentally characterized lauric-acid/stearic-acid eutectic 189.5 kJ kg−1 melting enthalpy; 39.29 °C melting peak), while an 80 wt% active-PCM composite represents agricultural-residue carbon support. Conductance is treated as a design variable rather than a feedstock-specific measured property. Under a prescribed high thermal duty of 32 W for 1200 s at 25 °C, the bare module reaches 61.07 °C, whereas lower- and higher-coupling composite cases reach 55.99 °C and 52.24 °C, corresponding to temperature-rise reductions of 14.1% and 24.5%. The higher-coupling case nevertheless accesses only 11.7% of its nominal latent reservoir. Sensitivity analysis and a conductance–latent-heat design map show that final temperature is substantially more sensitive to thermal coupling than to ±20% changes in nominal latent heat in this regime. The methodological novelty is the combined use of a latent-utilization ratio, a dimensionless thermal-access number, and a two-parameter design map to distinguish nominal latent storage from thermally accessible storage. The framework identifies when carbon-supported PCM can improve finite-duty buffering and defines the measurements required before practical battery validation.

  • Open Access

    Electronic Waste Recycling in Dhaka City Material Recovery and Institutional Governance

    by Md. Ariful Islam, Md. Lutfor Rahman, Sanjida Jahan

    In Dhaka, electronic waste is a growing urban management issue, alongside municipal waste systems, repair markets, informal collection, and emergent commercial recyclers. In this article, the evidence in a mixed-method thesis is restructured to explore collection practices, gaps in governance, environmental risks, and the economic logic of material recovery. The bottom-line work presents survey reports of questions to citizens, institutional and industry informants, field notes, and documents; it lacks a verifiable number of respondents or disaggregated survey estimates. The empirical explanation thus focuses on reported observations and considers numerical estimates as being calculated second. The thesis projects a range of e-waste production in 5.38-17.46 tonnes/day in the years 2012-2021; the calculation is not self-justifiable by using the provided information. A good example of price calculation is BDT 2,393,872.08 per tonne of printed circuit boards, in total, before recovery losses and expenditure and cannot be used on a tonne of mixed computers. Manual dismantling is reported in interviews and a volume of reported commercial collection of around 4 to 5 tonnes/day at a single operator. The results show that reclaimed opportunities are based on the separation of sources, safe dismantling, transfers that are traceable, and institutional obligations that can be enforced. There is a proposal of a staged city-wide system created between manufacturers, gatherers, recyclists, and city officials. The paper separates assumptions, empirical observations, and policy proposals to facilitate the cautious interpretation.

  • Open Access

    Subsurface Lithology and Sediment Texture as Indicators of Groundwater Potential in the Inani Anticline Cox’s Bazar

    by Md. Ariful Islam, Md. Serazul Islam, Md. Zakaria

    The exploration of groundwater in the coastal folded country should be sensitive to the texture of sediment and continuity of the confining layers. This paper assesses a 240 ft borehole in Inani Anticline region of Coxs Bazar in Bangladesh through lithological log of the borehole, 24 depth-indexed grain-size samples and consistency testing on some samples. Beds of sand are thick within the interval between about 20 to 90 ft. thin sand layers are found at depths of about 100 to 120 ft, with the log fraction varying widely, between about 8.50% and 46.02%. The sample at 170-190 ft and 220-240 ft have comparatively low pan fractions, whereas the 200 ft sample has 32.61%, indicating that the sequence at the bottom is heterogeneous. In the equation in the published values of the plastic limit, the plastic limit is greater than the value of the liquid limit, which provides nonsense positive plasticity indices; the indices produced in the consistency approach cannot be used to aid classification. The log and texture data together identify the candidate deeper sand targets, which are subject to verification by other boreholes, hydraulic tests and analysis of groundwater-quality. The work illustrates the importance of the combination of depth-resolved observations and maintaining a clear line between inferred aquifer potential and measured well performance.

  • Open Access

    Digital Transformation in the Electrical Manufacturing Industry: A Literature Review of Key Considerations and Strategic Priorities

    by Wael Ghazi Shaaban

    This paper reviews the digital transformation landscape confronting the electrical manufacturing industry, examining the technological, operational, and strategic considerations that determine successful adoption. Drawing on industry reports, case studies, and recent literature, the study synthesizes emerging technology trends, including advanced connectivity, the Internet of Things, artificial intelligence, and big-data analytics, and their implications for electrical businesses transitioning toward Industry 4.0 practices. A risk framework is developed to categorize the principal threats and opportunities facing the sector, addressing challenges such as legacy-system interoperability, networking infrastructure gaps, high capital requirements, supply chain disruptions, and evolving data-governance regulations. Successful transformation practices from established organizations, including P&G, GE Digital, Schneider Electric, and Enel X, are examined to extract lessons applicable to the electrical manufacturing context. The findings indicate that a resilient technology foundation, anchored in enterprise resource planning and a coherent digital ecosystem, underpins sustained transformation, while regulatory, workforce, and infrastructure constraints remain significant barriers. The paper concludes by outlining the digital ambitions and priorities electrical businesses should pursue, including investment in data analytics capabilities, cybersecurity, and low-code/no-code enterprise tools, to remain competitive amid accelerating global sustainability and digitalization targets.

  • Open Access

    Reviewing Methodological Contributions to Large-Scale Mobile Infrastructure Deployment Engineering

    by Svetlana Igorevna Polyakova

    Dense urban 5G coverage planning produces coverage holes and cost overruns that commentary attributes to the static functional form of legacy propagation models. This article develops an alternative account: documented planning failures trace to deployment geometries positioned outside a model’s calibrated envelope of frequency, distance, and antenna height, a condition that applies to learned predictive models with the same force it applies to parametric ones once the target environment departs from the training distribution. A structured comparative synthesis of peer-reviewed sources, organized into three evidentiary groups and supplemented by a quantitative extraction of documented error and boundary values, traces the relationship between deployment-geometry divergence and prediction error across both model classes. The extracted evidence shows accuracy scaling with distance from a model’s calibration envelope regardless of whether the model is parametric or learned, with reported degradation ranging from a few tenths of a decibel near a boundary to a documented 2.5-fold residual increase in a geometry absent from training data. The article’s contribution is a reframing of the field’s static-versus-predictive dichotomy around a single operative variable, calibration completeness relative to deployment geometry, supported by a comparative table of boundary conditions and a figure quantifying the error-distance relationship across independent studies.