Safety and Reliability of Power Industry
Published by NPO Energobezopasnost
- Scilit
- Thermodynamics
- Energy Systems & Technologies
- Power Systems & Electric Vehicles
- Friction & Vibration
- Facilities Management
- Nuclear Technology & Instrumentation
Publications Analysis
Publications in 2016-2026
Open Access Publications in 2016-2026
- Total Citations
- 23
- Total Publications
- 73
- Average Citations
- 0.32
- Cited Publications
- 14
- Cited Publications %
- 19.2%
- Self Citations
- 12
- Self Citations %
- 52.2%
- Q1
- 0
- Med
- 0
- Q3
- 1
- 99%
- 5.6
- Max
- 7
- Citing Source Titles
- Citing Publishers
Latest Publications
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 244
Памяти ученого, профессора, доктора технических наук Куличихина В.В.
Памяти ученого, профессора, доктора технических наук Куличихина В.В. | Редакционная | Надежность и безопасность энергетики
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 244
Памяти ученого, профессора, доктора технических наук Куличихина В.В.
Памяти ученого, профессора, доктора технических наук Куличихина В.В. | Редакционная | Надежность и безопасность энергетики
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 237-243
Digital CFD modeling of the ion-exchange filter regeneration process using COMSOL Multiphysics software
An important stage in the operation of ion-exchange filters used in water treatment units at thermal power plants is the regeneration process. Conducting studies on regeneration of ion-exchange filters directly on industrial equipment requires considerable material resources and is time-consuming. At the same time, experimental determination of the spatial distribution of flow velocities and component concentrations inside the filter is difficult. Therefore, the application of mathematical and numerical modeling methods is highly relevant, as they make it possible to investigate hydrodynamic, mass transfer, and ion-exchange kinetic processes without conducting labor- and resource-intensive experiments. The aim of this study is to develop and experimentally validate a transient digital CFD model of the process of regeneration of an industrial ion-exchange filter using COMSOL Multiphysics software. The digital model combines flow hydrodynamics in a porous medium, convective-diffusive mass transfer, and ion-exchange kinetics. A two-dimensional axisymmetric formulation was used for the modeling, with the main assumptions and limitations described in the paper. Spatial and temporal distributions of regenerant and reaction product concentrations, the dynamics of the concentration of sorbed chloride ions and ion-exchange resin regeneration degree, as well as the outlet concentration curve of the NaOH regenerant solution were obtained. The correctness of the digital CFD model formulation was confirmed by material balance agreement, the absence of negative concentrations, and the stability of the numerical solution. The numerical solution was validated against the results of an industrial experiment performed on an anion-exchange filter FIPa-3,4-6 at the Nizhnekamsk CHPP (PTK-1). The root mean square deviation between the calculated and experimental curves was 3824 mg/L, corresponding to a normalized error of 15%. The results confirm the applicability of the developed digital CFD model for analyzing the process of regeneration of industrial ion-exchange filters.
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 237-243
Digital CFD modeling of the ion-exchange filter regeneration process using COMSOL Multiphysics software
An important stage in the operation of ion-exchange filters used in water treatment units at thermal power plants is the regeneration process. Conducting studies on regeneration of ion-exchange filters directly on industrial equipment requires considerable material resources and is time-consuming. At the same time, experimental determination of the spatial distribution of flow velocities and component concentrations inside the filter is difficult. Therefore, the application of mathematical and numerical modeling methods is highly relevant, as they make it possible to investigate hydrodynamic, mass transfer, and ion-exchange kinetic processes without conducting labor- and resource-intensive experiments. The aim of this study is to develop and experimentally validate a transient digital CFD model of the process of regeneration of an industrial ion-exchange filter using COMSOL Multiphysics software. The digital model combines flow hydrodynamics in a porous medium, convective-diffusive mass transfer, and ion-exchange kinetics. A two-dimensional axisymmetric formulation was used for the modeling, with the main assumptions and limitations described in the paper. Spatial and temporal distributions of regenerant and reaction product concentrations, the dynamics of the concentration of sorbed chloride ions and ion-exchange resin regeneration degree, as well as the outlet concentration curve of the NaOH regenerant solution were obtained. The correctness of the digital CFD model formulation was confirmed by material balance agreement, the absence of negative concentrations, and the stability of the numerical solution. The numerical solution was validated against the results of an industrial experiment performed on an anion-exchange filter FIPa-3,4-6 at the Nizhnekamsk CHPP (PTK-1). The root mean square deviation between the calculated and experimental curves was 3824 mg/L, corresponding to a normalized error of 15%. The results confirm the applicability of the developed digital CFD model for analyzing the process of regeneration of industrial ion-exchange filters.
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 229-236
Study of the operation of a packing with transverse channels in a regenerative heat exchanger
Improving the thermal characteristics of regenerative heat exchangers is largely determined by optimal operating modes of the heat exchanger and increasing the efficiency of the packing. In turn, increasing the efficiency of the regenerator packing requires studying the thermal and hydrodynamic processes occurring within the packing and predicting their development, which will enable the creation of more energy-efficient and reliable apparatuses. During the operation of a regenerative heat exchanger, the heat transfer surface area can change significantly due to blockage of the main channels of the packing and removal of their surfaces from the heat exchange process. Transverse channels in packings allow the heat transfer surface downstream of the blockage to remain in operation. By applying a mathematical model for calculating flows in a system of channels of an arbitrarily specified structure to the channels of a packing with transverse channels of a regenerative heat exchanger, calculations of coolant flows through the packing channels were obtained. Cases of packing operation under blockage of the main packing channels were simulated. The results of calculating the mass flow rates of the coolant through the channels are presented. It is confirmed that the heat transfer surface of the main channel downstream of the blockage remains in operation, and the heat transfer surface of the transverse channels partially compensates for the non-operating heat transfer surface of the blocked channels due to the coolant flowing through them as it bypasses the blockage. Calculations confirm that in the main channels adjacent to the blocked ones, a significant flow rate fluctuation is observed. To increase efficiency, it is proposed, based on statistical data on packing failures, to make transverse channels of relatively small diameter more frequently in locations where channel blockages most often occur.
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 229-236
Study of the operation of a packing with transverse channels in a regenerative heat exchanger
Improving the thermal characteristics of regenerative heat exchangers is largely determined by optimal operating modes of the heat exchanger and increasing the efficiency of the packing. In turn, increasing the efficiency of the regenerator packing requires studying the thermal and hydrodynamic processes occurring within the packing and predicting their development, which will enable the creation of more energy-efficient and reliable apparatuses. During the operation of a regenerative heat exchanger, the heat transfer surface area can change significantly due to blockage of the main channels of the packing and removal of their surfaces from the heat exchange process. Transverse channels in packings allow the heat transfer surface downstream of the blockage to remain in operation. By applying a mathematical model for calculating flows in a system of channels of an arbitrarily specified structure to the channels of a packing with transverse channels of a regenerative heat exchanger, calculations of coolant flows through the packing channels were obtained. Cases of packing operation under blockage of the main packing channels were simulated. The results of calculating the mass flow rates of the coolant through the channels are presented. It is confirmed that the heat transfer surface of the main channel downstream of the blockage remains in operation, and the heat transfer surface of the transverse channels partially compensates for the non-operating heat transfer surface of the blocked channels due to the coolant flowing through them as it bypasses the blockage. Calculations confirm that in the main channels adjacent to the blocked ones, a significant flow rate fluctuation is observed. To increase efficiency, it is proposed, based on statistical data on packing failures, to make transverse channels of relatively small diameter more frequently in locations where channel blockages most often occur.
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 220-228
Modeling of pyrolysis of municipal solid waste in a shaft furnace based on Markov chains
Shaft-type furnaces, in which the organic component of the feedstock undergoes thermal decomposition, are widely used for the thermal processing of municipal solid waste (MSW) via pyrolysis. The end products of processing are combustible gas and solid carbon residue. Pyrolysis in shaft furnaces is characterized by a complex spatiotemporal organization of heat transfer processes, mass exchange of the gas and condensed phases, and chemical kinetics. Mathematical modeling of heat and mass transfer in shaft furnaces is one of the most labor-intensive and theoretically complex problems in computational thermal physics and chemical engineering. A Markov chain-based mathematical model can serve as a sufficiently simple and convenient model for practical use in this case. A one-dimensional Markov model of MSW processing is proposed, in which the technological process is described by a sequence of five aggregated states: drying, entry into active pyrolysis, two branches of pyrolysis gas utilization, and an absorbing state corresponding to the solid carbon residue. A transition probability matrix was constructed for the model, and simple, physically interpretable formulas for identifying its parameters based on the results of field and calculated data are proposed. Numerical experiments showed that the probability of transition to active pyrolysis increases with temperature; the proportion of gas consumed for own needs increases with increasing feedstock moisture content; the probability of pyrolysis completion reaches high values at temperatures of approximately 500–600°C; and the average process completion time in model steps decreases with increasing temperature. The modeling results are in qualitative agreement with experimental studies on drying and pyrolysis of MSW.
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 220-228
Modeling of pyrolysis of municipal solid waste in a shaft furnace based on Markov chains
Shaft-type furnaces, in which the organic component of the feedstock undergoes thermal decomposition, are widely used for the thermal processing of municipal solid waste (MSW) via pyrolysis. The end products of processing are combustible gas and solid carbon residue. Pyrolysis in shaft furnaces is characterized by a complex spatiotemporal organization of heat transfer processes, mass exchange of the gas and condensed phases, and chemical kinetics. Mathematical modeling of heat and mass transfer in shaft furnaces is one of the most labor-intensive and theoretically complex problems in computational thermal physics and chemical engineering. A Markov chain-based mathematical model can serve as a sufficiently simple and convenient model for practical use in this case. A one-dimensional Markov model of MSW processing is proposed, in which the technological process is described by a sequence of five aggregated states: drying, entry into active pyrolysis, two branches of pyrolysis gas utilization, and an absorbing state corresponding to the solid carbon residue. A transition probability matrix was constructed for the model, and simple, physically interpretable formulas for identifying its parameters based on the results of field and calculated data are proposed. Numerical experiments showed that the probability of transition to active pyrolysis increases with temperature; the proportion of gas consumed for own needs increases with increasing feedstock moisture content; the probability of pyrolysis completion reaches high values at temperatures of approximately 500–600°C; and the average process completion time in model steps decreases with increasing temperature. The modeling results are in qualitative agreement with experimental studies on drying and pyrolysis of MSW.
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 210-219
Intelligent control of domestic water heaters based on IoT and machine learning: analysis of energy efficiency and economic feasibility
A comprehensive analysis of the advantages and limitations of implementing intelligent control systems for domestic water heaters in Russian housing and utility services is presented. The relevance of the study is due to the high share of costs for heating and hot water supply in the energy consumption structure. An analysis of modern Russian and foreign solutions in the field of heating supply automation, the implementation of IoT systems, machine learning methods, and digital twin technologies was conducted. The architecture of an IoT system is described, including temperature and flow sensors, microcontrollers, and Wi-Fi modules for remote monitoring. Machine learning algorithms have been developed for predicting water consumption, allowing heating modes to be adapted to individual user needs. The methodology is based on mathematical modeling of thermal processes, taking into account Russian building codes and the climatic conditions of three cities: Moscow, Yekaterinburg, and Sochi. A comparative analysis of the energy efficiency of traditional and intelligent modes showed a reduction in energy consumption of 21.4% to 26% depending on the region; the greatest effect was recorded under conditions of a prolonged heating period. An economic assessment was performed depending on the region, tariffs, and equipment cost. The integration of intelligent boilers into the “smart city” concept and into a control system that ensures balancing of the grid load and participation in dynamic pricing programs was considered. The regulatory requirements of the Russian Federation were analyzed, identifying the main barriers to implementation: high initial costs, insufficient public awareness, and the absence of standardization of IoT devices. Ways to overcome the identified potential limitations are proposed: government subsidies, educational programs, and the development of national standards. The significant potential of intelligent water heaters as an element of digitalization of housing and utilities sector and for achieving national energy efficiency goals is shown.
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 210-219
Intelligent control of domestic water heaters based on IoT and machine learning: analysis of energy efficiency and economic feasibility
A comprehensive analysis of the advantages and limitations of implementing intelligent control systems for domestic water heaters in Russian housing and utility services is presented. The relevance of the study is due to the high share of costs for heating and hot water supply in the energy consumption structure. An analysis of modern Russian and foreign solutions in the field of heating supply automation, the implementation of IoT systems, machine learning methods, and digital twin technologies was conducted. The architecture of an IoT system is described, including temperature and flow sensors, microcontrollers, and Wi-Fi modules for remote monitoring. Machine learning algorithms have been developed for predicting water consumption, allowing heating modes to be adapted to individual user needs. The methodology is based on mathematical modeling of thermal processes, taking into account Russian building codes and the climatic conditions of three cities: Moscow, Yekaterinburg, and Sochi. A comparative analysis of the energy efficiency of traditional and intelligent modes showed a reduction in energy consumption of 21.4% to 26% depending on the region; the greatest effect was recorded under conditions of a prolonged heating period. An economic assessment was performed depending on the region, tariffs, and equipment cost. The integration of intelligent boilers into the “smart city” concept and into a control system that ensures balancing of the grid load and participation in dynamic pricing programs was considered. The regulatory requirements of the Russian Federation were analyzed, identifying the main barriers to implementation: high initial costs, insufficient public awareness, and the absence of standardization of IoT devices. Ways to overcome the identified potential limitations are proposed: government subsidies, educational programs, and the development of national standards. The significant potential of intelligent water heaters as an element of digitalization of housing and utilities sector and for achieving national energy efficiency goals is shown.
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 202-209
Implementation of Predictive Diagnostics on Key Elements of Electrical Engineering Systems at Oil and Gas Production Facilities
The article examines the problem of ensuring reliable and uninterrupted operation of electrical engineering systems at oil and gas enterprises, whose performance directly determines the stability of technological processes and the economic efficiency of production. Particular attention is given to high-voltage electric motors and power transformers as the most critical components of power supply systems, whose failure may lead to shutdowns of process lines, a reduction in the power supply reliability category, and significant financial losses. Based on an analysis of typical power supply schemes for liquefied natural gas plants and petrochemical enterprises, it is shown that traditional solutions based on equipment redundancy do not provide full protection against unplanned downtime, since after the failure of one element the system enters a critical operating mode. The necessity of transitioning from reactive and preventive maintenance models to proactive management of equipment condition is substantiated. As an effective solution, the implementation of predictive diagnostic systems is proposed, functioning on the basis of continuous comparison of actual equipment parameters with reference models developed using machine learning algorithms. An example of early detection of electric motor operation deviations, which cannot be identified by conventional relay protection and automation systems, is considered. Criteria for selecting facilities for the implementation of diagnostic models are formulated, including equipment criticality, lack of redundancy, impact on industrial and environmental safety, repair costs, and spare parts delivery time. The conclusion is formed that the use of predictive diagnostics makes it possible to detect developing defects in a timely manner, reduce the probability of emergency shutdowns, and improve the reliability of power supply for critical oil and gas industry facilities.
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 202-209
Implementation of Predictive Diagnostics on Key Elements of Electrical Engineering Systems at Oil and Gas Production Facilities
The article examines the problem of ensuring reliable and uninterrupted operation of electrical engineering systems at oil and gas enterprises, whose performance directly determines the stability of technological processes and the economic efficiency of production. Particular attention is given to high-voltage electric motors and power transformers as the most critical components of power supply systems, whose failure may lead to shutdowns of process lines, a reduction in the power supply reliability category, and significant financial losses. Based on an analysis of typical power supply schemes for liquefied natural gas plants and petrochemical enterprises, it is shown that traditional solutions based on equipment redundancy do not provide full protection against unplanned downtime, since after the failure of one element the system enters a critical operating mode. The necessity of transitioning from reactive and preventive maintenance models to proactive management of equipment condition is substantiated. As an effective solution, the implementation of predictive diagnostic systems is proposed, functioning on the basis of continuous comparison of actual equipment parameters with reference models developed using machine learning algorithms. An example of early detection of electric motor operation deviations, which cannot be identified by conventional relay protection and automation systems, is considered. Criteria for selecting facilities for the implementation of diagnostic models are formulated, including equipment criticality, lack of redundancy, impact on industrial and environmental safety, repair costs, and spare parts delivery time. The conclusion is formed that the use of predictive diagnostics makes it possible to detect developing defects in a timely manner, reduce the probability of emergency shutdowns, and improve the reliability of power supply for critical oil and gas industry facilities.
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 195-201
Modeling the tightness of the valve closing cone of diesel engine fuel injectors when operating on highly concentrated mixtures of diesel fuel with rapeseed oil
The relevance is due to the strategic necessity of substituting petroleum fuels with renewable bio-components in diesel engines, which requires revised methods for calculating the tightness of precision fuel injection components at high rapeseed oil concentrations. The aim of the study is the development and experimental verification of a theoretical model of the tightness of the valve closing cone of diesel fuel injectors at rapeseed oil content of 40–100%. The methodology integrates the Reynolds equation to describe hydrodynamic pressure in a tapered conical clearance and the Young-Laplace equation to account for capillary sealing forces. Physicochemical properties of mixtures are described using the Grunberg-Nissan model (viscosity), the additivity of reciprocal specific volumes (density), linear mixing (surface tension), and the Vogel, API, Brock-Bird temperature dependencies. Experimental verification was performed on three production FD-22.455.1112010-50 injectors at 20±2°C with high-frequency strain-gauge transducers recording dynamic pressure parameters. The results showed that within the verified 40–60% range, the tightness coefficient increases by a factor of 2.5–4.1 relative to baseline diesel fuel, while the relative modelling error does not exceed 0.5%. At concentrations below 40%, deviations of experimental data from calculated values were observed, due to increased elastic deformations and the manifestation of non-Newtonian rheological effects. The scientific novelty lies in the delineation of concentration zones of applicability of hydrodynamic lubrication theory for high-viscosity mixtures. Practical significance lies in the possibility of predicting tightness parameters of the valve closing cone without conducting a full set of costly bench tests, as well as in the justified selection of spray tip geometry to compensate for excessive viscosity loads when transitioning to high-concentration fuel mixtures, ensuring a reduction in the carbon footprint without compromising engine reliability.
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 195-201
Modeling the tightness of the valve closing cone of diesel engine fuel injectors when operating on highly concentrated mixtures of diesel fuel with rapeseed oil
The relevance is due to the strategic necessity of substituting petroleum fuels with renewable bio-components in diesel engines, which requires revised methods for calculating the tightness of precision fuel injection components at high rapeseed oil concentrations. The aim of the study is the development and experimental verification of a theoretical model of the tightness of the valve closing cone of diesel fuel injectors at rapeseed oil content of 40–100%. The methodology integrates the Reynolds equation to describe hydrodynamic pressure in a tapered conical clearance and the Young-Laplace equation to account for capillary sealing forces. Physicochemical properties of mixtures are described using the Grunberg-Nissan model (viscosity), the additivity of reciprocal specific volumes (density), linear mixing (surface tension), and the Vogel, API, Brock-Bird temperature dependencies. Experimental verification was performed on three production FD-22.455.1112010-50 injectors at 20±2°C with high-frequency strain-gauge transducers recording dynamic pressure parameters. The results showed that within the verified 40–60% range, the tightness coefficient increases by a factor of 2.5–4.1 relative to baseline diesel fuel, while the relative modelling error does not exceed 0.5%. At concentrations below 40%, deviations of experimental data from calculated values were observed, due to increased elastic deformations and the manifestation of non-Newtonian rheological effects. The scientific novelty lies in the delineation of concentration zones of applicability of hydrodynamic lubrication theory for high-viscosity mixtures. Practical significance lies in the possibility of predicting tightness parameters of the valve closing cone without conducting a full set of costly bench tests, as well as in the justified selection of spray tip geometry to compensate for excessive viscosity loads when transitioning to high-concentration fuel mixtures, ensuring a reduction in the carbon footprint without compromising engine reliability.
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 189-194
Diagnostic sign of rotor eccentricity in an induction motor
Rotor eccentricity is one of the most common defects in induction motors, arising from the wear of bearing assemblies. Its development leads to increased vibration, reduced mechanical performance, and the risk of rotor-tostator contact, which can result in complete drive failure. Existing diagnostic methods, such as stator current spectral analysis and vibration diagnostics, are characterized by high complexity of result processing, the lack of unambiguous differentiation from rotor bar breakage, as well as the need to install additional equipment or modify the motor design. A method for diagnosing rotor eccentricity in induction motors is proposed, based on the sum of the phase angles of the stator currents, calculated from five samples of instantaneous current values in steady-state operation using standard measuring instruments. It is shown that, unlike existing approaches, the proposed criterion provides unambiguous differentiation of static and dynamic eccentricity from rotor bar breakage based on the oscillation period of the diagnostic criterion. It is established that the oscillation period of the sum of the phase current angles under eccentricity is independent of the defect severity, while the amplitude increases with the degree of degradation, thus enabling the assessment of damage severity. The effectiveness of the proposed method is confirmed by computer simulation results using a mathematical model based on complete differential equations.
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 189-194
Diagnostic sign of rotor eccentricity in an induction motor
Rotor eccentricity is one of the most common defects in induction motors, arising from the wear of bearing assemblies. Its development leads to increased vibration, reduced mechanical performance, and the risk of rotor-tostator contact, which can result in complete drive failure. Existing diagnostic methods, such as stator current spectral analysis and vibration diagnostics, are characterized by high complexity of result processing, the lack of unambiguous differentiation from rotor bar breakage, as well as the need to install additional equipment or modify the motor design. A method for diagnosing rotor eccentricity in induction motors is proposed, based on the sum of the phase angles of the stator currents, calculated from five samples of instantaneous current values in steady-state operation using standard measuring instruments. It is shown that, unlike existing approaches, the proposed criterion provides unambiguous differentiation of static and dynamic eccentricity from rotor bar breakage based on the oscillation period of the diagnostic criterion. It is established that the oscillation period of the sum of the phase current angles under eccentricity is independent of the defect severity, while the amplitude increases with the degree of degradation, thus enabling the assessment of damage severity. The effectiveness of the proposed method is confirmed by computer simulation results using a mathematical model based on complete differential equations.
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 181-188
Analysis of the efficiency of using mini-CHPs based on a gas piston engine at district heating enterprises
The potential of using gas-piston mini-CHPs in heat supply enterprises in small towns and settlements is analyzed. The aim of this study is to determine the feasibility of using engine heat to heat supply network water. One of the industrial heating boiler houses of the Zelenodolsk heating network (PTS) located on Paratskaya Street in Zelenodolsk, Republic of Tatarstan, with an installed capacity of 363.9 Gcal/h, was selected as the object of study. The subject of the study is the heat removed from the engine. During the study, methods of thermal, aerodynamic, and hydraulic calculations of the engine and the exhaust gas removal system were applied. The lower heating value was determined based on the chemical composition of the gas used at the enterprise. A heat balance of the gas piston unit was compiled. A scheme for integrating the mini-CHP into the district heating supply system is proposed. It was found that during operation of the gas piston units, the exhaust gases have a temperature of approximately 550°C. Utilization of this heat increases the efficiency of the mini-CHP by 33%. Utilization of the thermal energy of the engine cooling jacket can increase the efficiency by another 22%. Taking into account the use of engine heat in heating networks, the efficiency of the miniCHP can reach 96%. In order to utilize the latent heat of vaporization of water in flue gases, a two-stage condensing surface heat recovery unit was calculated and designed. The return network water was used as the heated coolant in the first stage. Chemically treated water is supplied to the second stage. The data were taken from the thermal diagram of the boiler house. The condensing surface heat recovery unit increases the efficiency of the mini-CHP by 12%, taking into account the higher heating value. The economic effect of implementing three mini-CHPs at the Zelenodolsk district heating enterprise of the Republic of Tatarstan amounts to 185.0 million rubles per year. The payback period for these mini-CHPs does not exceed three years.
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 181-188
Analysis of the efficiency of using mini-CHPs based on a gas piston engine at district heating enterprises
The potential of using gas-piston mini-CHPs in heat supply enterprises in small towns and settlements is analyzed. The aim of this study is to determine the feasibility of using engine heat to heat supply network water. One of the industrial heating boiler houses of the Zelenodolsk heating network (PTS) located on Paratskaya Street in Zelenodolsk, Republic of Tatarstan, with an installed capacity of 363.9 Gcal/h, was selected as the object of study. The subject of the study is the heat removed from the engine. During the study, methods of thermal, aerodynamic, and hydraulic calculations of the engine and the exhaust gas removal system were applied. The lower heating value was determined based on the chemical composition of the gas used at the enterprise. A heat balance of the gas piston unit was compiled. A scheme for integrating the mini-CHP into the district heating supply system is proposed. It was found that during operation of the gas piston units, the exhaust gases have a temperature of approximately 550°C. Utilization of this heat increases the efficiency of the mini-CHP by 33%. Utilization of the thermal energy of the engine cooling jacket can increase the efficiency by another 22%. Taking into account the use of engine heat in heating networks, the efficiency of the miniCHP can reach 96%. In order to utilize the latent heat of vaporization of water in flue gases, a two-stage condensing surface heat recovery unit was calculated and designed. The return network water was used as the heated coolant in the first stage. Chemically treated water is supplied to the second stage. The data were taken from the thermal diagram of the boiler house. The condensing surface heat recovery unit increases the efficiency of the mini-CHP by 12%, taking into account the higher heating value. The economic effect of implementing three mini-CHPs at the Zelenodolsk district heating enterprise of the Republic of Tatarstan amounts to 185.0 million rubles per year. The payback period for these mini-CHPs does not exceed three years.
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 173-180
Sensitivity analysis of short-circuit protection during starting of an asynchronous motor with stator winding switching in 0.4 kV networks
The possibilities of starting asynchronous squirrel-cage motors by switching the stator windings of the motor, connected in a star configuration, to a delta configuration during starting are considered. The application of this method reduces the multiplicity of starting currents and increases the sensitivity of protective devices, which contributes to ensuring reliable and selective protection of equipment and safe starting of motors. The necessity of performing the proposed switching with a power interruption is substantiated; however, the small influence of the dead time on the quantitative characteristics of transient processes during starting is demonstrated. Using the Euler method, calculations of transient electromechanical processes during starting using the classical scheme and when switching winding connection schemes were performed. The starting characteristics of the motors are analyzed in combination with the time-current characteristics of circuit breakers. Based on the analysis results, the possibility of increasing the sensitivity of the circuit breaker tripping during transition to star-delta starting is determined, which minimizes the risk of false tripping during starting while simultaneously ensuring effective short-circuit protection. Based on variable calculations taking into account different motor power ratings, their parameters, and the characteristics of protective devices, the areas of most effective application of the proposed starting method are determined. The application of the method considered in the paper for switching the stator windings of a squirrelcage induction motor from star to delta contributes to increasing reliability and efficiency of electric motor starting systems and protective devices, resulting in reduced operating costs and improved overall safety of circuits with squirrel-cage induction motors.
- 26 October 2026
- Published by NPO Energobezopasnost in Safety and Reliability of Power Industry
- Vol. 19 (3) , 173-180
Sensitivity analysis of short-circuit protection during starting of an asynchronous motor with stator winding switching in 0.4 kV networks
The possibilities of starting asynchronous squirrel-cage motors by switching the stator windings of the motor, connected in a star configuration, to a delta configuration during starting are considered. The application of this method reduces the multiplicity of starting currents and increases the sensitivity of protective devices, which contributes to ensuring reliable and selective protection of equipment and safe starting of motors. The necessity of performing the proposed switching with a power interruption is substantiated; however, the small influence of the dead time on the quantitative characteristics of transient processes during starting is demonstrated. Using the Euler method, calculations of transient electromechanical processes during starting using the classical scheme and when switching winding connection schemes were performed. The starting characteristics of the motors are analyzed in combination with the time-current characteristics of circuit breakers. Based on the analysis results, the possibility of increasing the sensitivity of the circuit breaker tripping during transition to star-delta starting is determined, which minimizes the risk of false tripping during starting while simultaneously ensuring effective short-circuit protection. Based on variable calculations taking into account different motor power ratings, their parameters, and the characteristics of protective devices, the areas of most effective application of the proposed starting method are determined. The application of the method considered in the paper for switching the stator windings of a squirrelcage induction motor from star to delta contributes to increasing reliability and efficiency of electric motor starting systems and protective devices, resulting in reduced operating costs and improved overall safety of circuits with squirrel-cage induction motors.