International Journal of Applied Power Engineering (IJAPE)

Published by Institute of Advanced Engineering and Science

Abbrev: Int. J. Appl. Power Eng. (IJAPE)
ISSN 2252-8792EISSN 2722-2624
Database Coverage
  • Scopus
  • Scilit
Journal Articles
All-time journal articles
615
2025 journal articles
105
Subject
  • Multidisciplinary

Publications Analysis

Publications in 2016-2026
Open Access Publications in 2016-2026
Top Subjects

Publications in 2016-2026.

SubjectPublications
Power Systems & Electric Vehicles
454
Energy Systems & Technologies
111
Control & Automation Engineering
79
AI & Machine Learning
43
Electrical Safety
36
Electrical Energy Management
33
Friction & Vibration
21
Thermodynamics
15
Sustainability Studies
14
Semiconductor Physics
8

Top Countries

Publications in 2016-2026.

CountryPublications
India
218
Indonesia
61
Morocco
27
Algeria
26
Malaysia
18
Iraq
14
South Korea
13
Nigeria
11
Vietnam
10
Iran
9

Citation analysis
Publications published in 2023-2024 and cited in 2025.
Total Citations
249
Total Publications
144
Average Citations
1.73
Cited Publications
85
Cited Publications %
59%
Self Citations
12
Self Citations %
4.8%

Metrics
2025 Integrated Impact Indicators
I3
58
I3/N
1.07
h5_index
11
Monthly Citation Metric (MCM)
0.9

Monthly Citation Metric

Citations per year
All citations in 2016-2026

Citation Distribution
All citations to publications in 2023-2024.
Q1
1
Med
2
Q3
4.3
99%
26.3
Max
67

Citation Origins
Publications published in 2023-2024 and cited in 2025.
Citing Source Titles
Citing Publishers

Latest Publications

  • Open Access

    Effect of power and voltage variations on transformer core losses and geometry for two distinct core materials

    by Kamran Dawood, Furkan Gezer, Güven Kömürgöz Kırış, Semih Tursun

    This study presents a comprehensive comparison of transformer core size and no-load losses, focusing on transformers with power ratings ranging from 400 kVA to 3200 kVA. The research evaluates transformer performance at three distinct primary voltage levels: 6 kV, 15 kV, and 33 kV, while maintaining a constant secondary voltage of 0.4 kV. Additionally, the study investigates the impact of two commonly used transformer core materials, M4 and H0, on core design, with a particular focus on their effects on no-load losses. Another central aspect of the analysis is the examination of core geometry, including the cross-sectional area and height of the transformer core, across various power ratings and voltage levels. The results reveal a clear relationship between core size and energy efficiency. M4 cores exhibit higher no-load losses compared to H0 cores; additionally, H0 cores demonstrate better overall efficiency, making them ideal for high-efficiency applications. The findings underscore the importance of selecting the right core materials and geometries to balance performance, efficiency, and size. These insights are intended to guide researchers and transformer designers in making informed decisions when developing energy-efficient solutions for diverse applications across the electrical power industry.

  • Open Access

    To enhance efficiency in photovoltaic systems using optimization methods in battery management system

    by Penumala Poornima, Kannan Boopathy

    Battery management systems (BMS) have undergone significant advancements over the years, transitioning from basic control strategies to sophisticated optimization algorithms. Historically, established BMS approaches were limited in their ability to handle energy efficiently, often leading to suboptimal power utilization and higher total harmonic distortion (THD). Integration of in a BMS application in modern days. advanced algorithms, such as flying squirrel search optimization (FSSO), have been optimized using grey wolf optimizer (GWO), and artificial neural network (ANN) significantly enhanced the performance of the system. These algorithms are efficient in terms of optimizing the duty cycle, whereby there is even a healthy energy flow between renewable load requirements and power requirements. These algorithms are analyzed, and their effectiveness in comparing their effectiveness is different operational scenarios. GWO algorithm is indicated as having the best reduction of THD and consequently improving the quality of power in a minimized way reliability. The ANN shows great expertise in voltage. regulating, low level of THD. Meanwhile, the FSSO algorithm shows significant potential in improving energy efficiency and reducing operational costs, despite its higher THD levels in current phases. GWO has a minimal current THD of 4.65% in Phase 1, exceeding ANN and FSSO. ANN has a voltage THD of 10.61%. FSSO has greater current THD values over 15% and good voltage control, highlighting decisions.

  • Open Access

    Impact of an SVC device on voltage and transient stability in power systems

    by Makhlouf Chouki, Hicham Zaimen, Hassen Belila

    The increasing complexity of modern electrical networks, driven by the expansion of transmission networks along with the increasing penetration of renewable-based generation, has intensified concerns regarding voltage control performance and rotor-angle stability. Flexible AC transmission system (FACTS) technology, particularly the shunt-connected static var compensator (SVC), offers effective solutions for enhancing system performance through dynamic reactive power support. This study examines the effect of SVC integration on voltage regulation performance as well as rotor-angle stability within electrical transmission networks. The study is conducted using MATLAB and the electrical network analysis toolbox (PSAT) on IEEE 5-bus, 14-bus, and 9-bus benchmark systems. Voltage stability performance is evaluated under transmission line outage conditions, while rotor-angle stability is assessed through critical clearing time (CCT) analysis during balanced three-phase faults. The simulation results demonstrate that the incorporation of an SVC considerably improves voltage profiles, reduces active and reactive power losses, and enhances system resilience under disturbed operating conditions. Furthermore, the SVC increases the critical clearing time and improves post-fault dynamic behavior, contributing to better preservation of generator synchronism. The presented results confirm that SVC-based compensation provides an effective and practical solution for strengthening both voltage control performance and rotor-angle stability reserves in power transmission systems.

  • Open Access

    Mitigation of grid harmonics using active filters with adaptive energy valley optimization (AEVO) control techniques

    by Nagaraja Bodravara, Ezhilarasan Ganesan

    Many nonlinear devices are linked to the power grid as the fast development of the power electronics sector causes serious harmonic pollution of the grid voltage. Active power filter (APF), which can detect the harmonics at the installation location, is the tool used for the harmonic voltage treatment. While considering the surplus of APF active devices to guarantee effective and stable operation of APF, the harmonic sources at each node will change with time and need the injection of fresh harmonic compensation commands. This work intends to offer a dynamic adjustment approach of distributed harmonic compensation based on the computation model of active device margin of APF. First, for certain harmonic combinations, the APF active device loss and injection temperature model is developed to compute in real time whether the harmonic injection command satisfies the active device margin. Furthermore, the adaptive energy valley optimization method is applied to derive new harmonic injection commands for the power grid with harmonic source changes, which on one hand lowers the total voltage harmonic distortion rate of the power grid, and on the other hand satisfies the active device margin to guarantee stable operation of APF.

  • Open Access

    Environmental footprint assessment of lithium-ion (Li-ion) batteries in electric scooters: a case study of PT Motor Listrik Indonesia

    by Rafi Juniar Saputra, Aufar Fikri Dimyati, Silvi Istiqomah, Dwi Heru Siswantoro

    Indonesia ranks as the world's sixth-largest contributor to CO2 emissions, with motorcycles alone responsible for 56,788 tons of CO2 in 2020. While electric motorbikes are considered a cleaner alternative due to their lack of exhaust emissions, their overall environmental impact must be evaluated throughout the entire battery life cycle. This study conducts a gate-to-grave life cycle assessment (LCA) on the lithium-ion (Li-ion) batteries used in MOLINDO electric motorbikes, covering the supplier, production, usage, and disposal stages. The total environmental impact was found to be 920 points (pt), with the usage phase being the largest contributor at 550 pt, followed by production at 185.5 pt, supplier at 179 pt, and disposal at 5.54 pt. Two improvement strategies were explored: reusing external battery cases, which slightly reduced the impact to 918.86 pt, and repurposing second-life batteries, which extended battery use but increased the impact to 998.04 pt due to additional energy requirements. Compared to conventional motorbikes, electric motorbikes still offer a major environmental advantage in the usage phase (550 pt vs. 3,397 pt). These findings suggest that, alongside the shift to electric mobility, targeted actions such as better battery reuse, more efficient recycling, and cleaner electricity sources are essential to fully unlock the environmental benefits of electric motorbikes.

  • Open Access

    Explainable AI for harmonic fingerprinting and voltage sag diagnosis in decentralized power grids: trends, challenges and future directions

    by Mohd Hatta Jopri, Tole Sutikno, Yacine Djeghader, Mohd Riduan Mohd Shariff, Wan Azlan Wan Zainal Abidin

    The evolution of decentralized power grids has increased the complexity of power-quality monitoring, particularly harmonic fingerprinting and voltage sag diagnosis. Artificial intelligence improves disturbance detection and classification, yet black-box models limit transparency, engineering validation, and operator trust. This review synthesizes 108 selected studies on explainable artificial intelligence (XAI) for power-system diagnostics, focusing on SHapley Additive exPlanations (SHAP), local interpretable model-agnostic explanations (LIME), attention-based interpretability, visual analytics, and physics-informed learning. The review integrates harmonic fingerprinting with voltage sag diagnosis through their shared requirements for source attribution, temporal interpretation, physical consistency, and operator-oriented explanation. Four major deployment gaps are identified: data quality, computational latency, physical grounding, and trustworthiness. Future priorities include real-time embedded XAI, physics-informed neural networks, federated learning, standardized trustworthiness metrics, and adaptive model lifecycle management. The findings indicate that reliable autonomous diagnosis requires explainability to be integrated with predictive performance, electrical-system physics, computational efficiency, and field validation. This integration provides a stronger foundation for transparent, resilient, and trustworthy diagnostic systems in decentralized power grids.

  • Open Access

    Improved microgrid energy coordination via hybrid PSO and bidirectional EV integration: performance comparison against genetic algorithm

    by Bilal Amghar, Toufik Azib, Khelil Sidi Brahim

    This paper presents a comparative study between hybrid particle swarm optimization (PSO) and genetic algorithm (GA) for energy management in residential microgrids equipped with photovoltaic generation, stationary battery storage, and bidirectional electric vehicles (V2G). The system comprises 40 apartments, 1000 m² solar panels, 1 MWh battery storage, and 15 electric vehicles with V2G capability. A multi-objective optimization framework minimizes daily operational costs while satisfying mobility requirements, state-of-charge constraints, and battery aging considerations. Simulation results demonstrate that hybrid PSO significantly outperforms GA, achieving a net daily profit of 279 C (compared to 100 C cost for GA) through strategic energy arbitrage and massive grid sales (2232 kWh/day vs 3.7 kWh/day for GA). The PSO-based approach achieves 28% energy autonomy while generating substantial revenue from feed-in tariffs. The methodology provides a scalable framework for real-world V2G-integrated microgrids, with ongoing experimental validation at the ESTACA V2G testbed.

  • Open Access

    Hybrid AC/DC and conventional AC house efficiency for net zero energy homes

    by Taufik Taufik, Heru Nurwarsito, Tyler Bury, Rahman Azis Prasojo

    The transition toward net-zero energy homes (NZEH) requires residential electrical systems that can efficiently integrate renewable generation, battery storage, and both AC and direct current (DC) loads. Although DC and hybrid AC/DC residential systems have been widely studied, limited work directly compares hybrid AC/DC and conventional AC house architectures under different grid standards, power levels, and AC/DC load ratios while considering DC bus losses. This study presents a MATLAB/Simulink-based steady-state efficiency comparison between hybrid AC/DC and conventional AC residential electrical systems. Twelve models were developed, consisting of six hybrid AC/DC and six conventional AC configurations under 120 V/60 Hz and 230 V/50 Hz standards. The models include PV generation, battery storage, inverter, AC/DC converter, multiple-input single-output (MISO) converter, and line-resistance effects. Results show that hybrid AC/DC houses achieve 4-11% higher efficiency than conventional AC houses when DC load demand remains below approximately 1.5-2.0 kW, mainly due to reduced conversion stages. At higher DC load levels, the efficiency advantage decreases because of copper losses in the 48 V DC bus. Increasing the DC bus voltage to 60 V reduces current-related losses and extends the efficient operating range. These findings indicate that hybrid AC/DC distribution is most suitable for residential applications with low-to-moderate DC demand, such as lighting, electronics, communication devices, and other DC-compatible appliances. The main contribution of this study is identifying the operating range, efficiency limit, and practical design implications of hybrid AC/DC residential distribution for future NZEH applications.

  • Open Access

    Voltage stability analysis of power transmission systems using multi-index framework of hybrid whale and particle swarm optimization technique

    by Titus Terwase Akor, Theophilus Chukwudolue Madueme, Chibuike Peter Ohanu, Tole Sutikno

    The persistent increase in grid collapse has necessitated the need for robust solutions for stability. Hybrid whale and particle swarm optimization (WAPSO) algorithm integrated with multi-index stability indices (MIS) has been applied to enhance voltage stability in this paper. The method is tested on the Nigeria 48-bus, 330 kV transmission system and simulated in MATPOWER embedded in MATLAB. The WAPSO algorithm is optimized with parameters w = 0.4, c₁ = 1.4 and c₂ = 1.5. The outcome achieved 98.84% reduction in mean MIS from 0.3959 to 0.0048 and a robustness index of 0.0051. This depicts low variability of 0.057 and 100% success rate across five dynamic scenarios explored such as gradual load growth with 98.79%, sudden spikes achieved 98.84%, cyclic fluctuations at 98.67%, renewable uncertainty at 98.74%, and N-1 contingencies at 98.84% improvement, respectively. Critical lines, 34-35 and 24-33 exhibit more than 99% MIS improvement, while weak lines, 21-22 and 24-40 achieved 85–87% enhancement, indicating areas for further reinforcement. The LSI and FVSI are reduced to 0.0048 and 0.1477 showing 56.79% improvement respectively as against the 38.9% MIS improvement obtained with the PSO-GA. This demonstrates WAPSO as a highly robust and adaptable technique offering a scalable solution for enhancing grid reliability under dynamic conditions.

  • Open Access

    Comparative study of MPPT algorithm on photovoltaic string under partial shading

    by Dikpride Despa, Gigih Forda Nama, Zulmiftahul Huda, Stefanus Debiarto Marudut Sagala

    Partial shading significantly degrades the photovoltaic (PV) performance value by introducing multiple peaks in power voltage (P-V) curve, complicating maximum power point tracking (MPPT). This research aims to presents a systematic comparative study of 4 MPPT algorithms, that are i) perturb and observe (P&O), ii) incremental conductance (InC), iii) particle swarm optimization (PSO), and iv) flower pollination algorithm (FPA), under 6 systematically testbeds modeled irradiance scenarios. The evaluation focused on tracking accuracy, convergence speed, and also robustness against local maxima entrapment. The findings indicated that slope-based algorithms (P&O and InC algorithm) achieved rapid convergence (<0.05 second), under uniform conditions but consistently fail to locate the global maximum power point (GMPP) in multi peak profiles, with efficiency dropping to ~83.6%. While the PSO algorithm succeeds in moderately faced complex cases, it fails under highly multimodal landscapes due to premature convergence. In contrast, for FPA algorithm consistently identifies the GMPP across all scenarios, its achieving superior tracking efficiency of up to 99.8%, despite requiring longer settling times (0.75-1.03 seconds) and exhibiting transient oscillations. These findings quantify the speed-accuracy trade-off in MPPT controllers and highlight the necessity of global optimization for reliable performance under dynamic shading. Future work will address the challenge of hardware implementation in the loop validation and computational efficiency for real-time embedded applications.