Latest Publications
- Open Access
- 26 August 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 10 (1) , 155-162
Analisis Stabilitas Lereng dan Dinding Penahan Tanah Kantilever Berbasis Back Analysis Geo5 Jalan Suryanata Samarinda
This study aimed to evaluate the safety factors of the existing slope and a proposed cantilever retaining wall by comparing manual calculations using the Fellenius and Coulomb methods with GEO5 analysis. Secondary data included Standard Penetration Test (SPT) results and laboratory soil test data from two boreholes. The analysis comprised slope stability assessment, back analysis to calibrate soil parameters, lateral earth pressure estimation, and retaining wall stability evaluation against overturning, sliding, and bearing capacity failure. Manual calculations produced slope safety factors of 1.53–2.26, whereas back analysis using GEO5 reduced the values to 0.91–1.23, indicating unstable conditions. The proposed cantilever retaining wall satisfied all stability requirements, with overturning safety factors of 10.70 and 7.12, sliding safety factors of 2.87 and 2.26, and bearing capacity safety factors of 3.12–3.30 and 3.21 from manual and GEO5 analyses, respectively. The proposed retaining wall is structurally safe, and GEO5 provides more conservative safety factor estimates than manual calculations. Keywords: Fellenius, GEO5, Retaining Wall, Slope Stability
- 26 August 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 10 (1) , 155-162
Open AccessAnalisis Stabilitas Lereng dan Dinding Penahan Tanah Kantilever Berbasis Back Analysis Geo5 Jalan Suryanata Samarinda
This study aimed to evaluate the safety factors of the existing slope and a proposed cantilever retaining wall by comparing manual calculations using the Fellenius and Coulomb methods with GEO5 analysis. Secondary data included Standard Penetration Test (SPT) results and laboratory soil test data from two boreholes. The analysis comprised slope stability assessment, back analysis to calibrate soil parameters, lateral earth pressure estimation, and retaining wall stability evaluation against overturning, sliding, and bearing capacity failure. Manual calculations produced slope safety factors of 1.53–2.26, whereas back analysis using GEO5 reduced the values to 0.91–1.23, indicating unstable conditions. The proposed cantilever retaining wall satisfied all stability requirements, with overturning safety factors of 10.70 and 7.12, sliding safety factors of 2.87 and 2.26, and bearing capacity safety factors of 3.12–3.30 and 3.21 from manual and GEO5 analyses, respectively. The proposed retaining wall is structurally safe, and GEO5 provides more conservative safety factor estimates than manual calculations. Keywords: Fellenius, GEO5, Retaining Wall, Slope Stability
- Open Access
- 26 August 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 10 (1) , 163-186
Analisis Kelayakan dan Performa Sistem Hibrida PLTS-PLTB-PLTSA Terintegrasi Grid untuk Kebutuhan Energi Kampus Berbasis Homer Pro
The increasing demand for electrical energy in university campuses requires the development of energy systems that are reliable, economically feasible, and environmentally sustainable. This study aims to evaluate the technical performance, economic feasibility, and environmental impact of a hybrid energy system integrating Solar Photovoltaic (PV), Wind Turbine (WT), and Waste-to-Energy (WTE) power generation connected to the utility grid. The research methodology involved collecting renewable energy resource data, electrical load profiles, and techno-economic parameters, which were subsequently analyzed using HOMER Pro software to determine the optimal system configuration. The simulation results indicate that the proposed system is capable of generating 972,876 kWh/year of electricity, with renewable energy contributing 717,784 kWh/year or approximately 73.8% of the total annual energy production. The system achieved a renewable fraction of 75.2%, a Net Present Cost (NPC) of IDR 13.85 billion, and a Cost of energy (COE) of IDR 1,122/kWh. Furthermore, the electricity exported to the grid reached 315,694 kWh/year, exceeding the imported electricity of 255,092 kWh/year, indicating that the system operates as a net exporter. From an environmental perspective, the WTE unit utilizes 88.7 tons of municipal solid waste annually while supporting emission reduction and renewable energy utilization. Overall, the results demonstrate that the proposed hybrid system is technically reliable, economically viable, and environmentally beneficial, making it a promising solution for supporting green campus development and sustainable energy implementation. Keywords: HOMER Pro; Hybrid System; PLTS; PLTSa; Renewable Energy.
- 26 August 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 10 (1) , 163-186
Open AccessAnalisis Kelayakan dan Performa Sistem Hibrida PLTS-PLTB-PLTSA Terintegrasi Grid untuk Kebutuhan Energi Kampus Berbasis Homer Pro
The increasing demand for electrical energy in university campuses requires the development of energy systems that are reliable, economically feasible, and environmentally sustainable. This study aims to evaluate the technical performance, economic feasibility, and environmental impact of a hybrid energy system integrating Solar Photovoltaic (PV), Wind Turbine (WT), and Waste-to-Energy (WTE) power generation connected to the utility grid. The research methodology involved collecting renewable energy resource data, electrical load profiles, and techno-economic parameters, which were subsequently analyzed using HOMER Pro software to determine the optimal system configuration. The simulation results indicate that the proposed system is capable of generating 972,876 kWh/year of electricity, with renewable energy contributing 717,784 kWh/year or approximately 73.8% of the total annual energy production. The system achieved a renewable fraction of 75.2%, a Net Present Cost (NPC) of IDR 13.85 billion, and a Cost of energy (COE) of IDR 1,122/kWh. Furthermore, the electricity exported to the grid reached 315,694 kWh/year, exceeding the imported electricity of 255,092 kWh/year, indicating that the system operates as a net exporter. From an environmental perspective, the WTE unit utilizes 88.7 tons of municipal solid waste annually while supporting emission reduction and renewable energy utilization. Overall, the results demonstrate that the proposed hybrid system is technically reliable, economically viable, and environmentally beneficial, making it a promising solution for supporting green campus development and sustainable energy implementation. Keywords: HOMER Pro; Hybrid System; PLTS; PLTSa; Renewable Energy.
- Open Access
- 26 August 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 10 (1) , 141-154
Tinjauan Literatur Pengaruh Doping Fe terhadap Struktur dan Performa Termoelektrik Paduan Full-Heusler Ni₂Coal
The increasing energy demand, together with waste heat released from industrial processes, transportation systems, power plants, and mechanical equipment, has encouraged the development of efficient, sustainable, and environmentally friendly energy conversion materials. Thermoelectric materials are promising candidates because they can directly convert temperature differences into electrical energy through the Seebeck effect without moving components, making them suitable for waste heat recovery applications. However, their practical use is still limited by relatively low conversion efficiency, which is expressed by the figure of merit (ZT). The ZT value depends on the balance among the Seebeck coefficient, electrical conductivity, and thermal conductivity; therefore, improving one parameter often affects the others. In this context, full-Heusler alloys are attractive because they possess crystal structure flexibility, good thermal stability, and electronic properties that can be tuned through elemental substitution. This literature review aims to analyze the effect of Fe Doping on the structure and thermoelectric performance of Ni₂CoAl full-Heusler alloys by examining 50 journal references related to thermoelectric materials, Heusler alloys, Fe-based full-Heusler compounds, half-Heusler systems as comparisons, and Ni-Co-Al compounds. The review indicates that Fe Doping may modify lattice parameters, induce structural distortion, regulate carrier concentration, and enhance phonon scattering to reduce lattice thermal conductivity. Furthermore, Fe Doping may influence atomic ordering and electronic transport behavior that determine power factor improvement. Nevertheless, direct studies on Ni₂₋ₓFeₓCoAl remain limited; therefore, experimental investigations are required to correlate Doping composition, crystal structure, transport properties, and ZT values systematically Keywords: Fe Doping; Full-Heusler; Ni₂CoAl; Thermoelectric; Figure of merit
- 26 August 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 10 (1) , 141-154
Open AccessTinjauan Literatur Pengaruh Doping Fe terhadap Struktur dan Performa Termoelektrik Paduan Full-Heusler Ni₂Coal
The increasing energy demand, together with waste heat released from industrial processes, transportation systems, power plants, and mechanical equipment, has encouraged the development of efficient, sustainable, and environmentally friendly energy conversion materials. Thermoelectric materials are promising candidates because they can directly convert temperature differences into electrical energy through the Seebeck effect without moving components, making them suitable for waste heat recovery applications. However, their practical use is still limited by relatively low conversion efficiency, which is expressed by the figure of merit (ZT). The ZT value depends on the balance among the Seebeck coefficient, electrical conductivity, and thermal conductivity; therefore, improving one parameter often affects the others. In this context, full-Heusler alloys are attractive because they possess crystal structure flexibility, good thermal stability, and electronic properties that can be tuned through elemental substitution. This literature review aims to analyze the effect of Fe Doping on the structure and thermoelectric performance of Ni₂CoAl full-Heusler alloys by examining 50 journal references related to thermoelectric materials, Heusler alloys, Fe-based full-Heusler compounds, half-Heusler systems as comparisons, and Ni-Co-Al compounds. The review indicates that Fe Doping may modify lattice parameters, induce structural distortion, regulate carrier concentration, and enhance phonon scattering to reduce lattice thermal conductivity. Furthermore, Fe Doping may influence atomic ordering and electronic transport behavior that determine power factor improvement. Nevertheless, direct studies on Ni₂₋ₓFeₓCoAl remain limited; therefore, experimental investigations are required to correlate Doping composition, crystal structure, transport properties, and ZT values systematically Keywords: Fe Doping; Full-Heusler; Ni₂CoAl; Thermoelectric; Figure of merit
- Open Access
- 30 June 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 9 (2) , 45-63
Analisis Kualitas Daya Sebagai Indikator Keandalan dan Keselamatan Operasional Sistem Distribusi Listrik pada Gedung Bertingkat
This study aims to evaluate power quality and analyze its impact on the reliability of electrical distribution systems in a high-rise building. The study employed a quantitative descriptive method through field measurements using a Power Quality Analyzer PEL 103 Chauvin Arnoux installed on the distribution panels of ten floors. The observed parameters included voltage, voltage unbalance, current unbalance, power factor, and total harmonic distortion of voltage (THDv) and current (THDi). The results indicate that the voltage level (229.18–235.02 V), voltage unbalance (0.31–1.17%), power factor (0.86–0.99), and THDv (<5%) comply with IEC 61000, SNI IEC 61000, Permen ESDM No. 04 of 2009, and IEEE 519-2014/2022 standards. However, current unbalance exceeded the permissible limit of 20% on seven floors, and THDi values on several floors exceeded 15%, indicating the presence of nonlinear loads. It can be concluded that the electrical distribution system of the high-rise building exhibits good voltage stability; however, load balancing among phases and harmonic mitigation measures are necessary to maintain the long-term reliability and safety of the electrical installation. Keywords: Electrical Distribution, Harmonics, High-Rise Building, Power Factor, Power Quality.
- 30 June 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 9 (2) , 45-63
Open AccessAnalisis Kualitas Daya Sebagai Indikator Keandalan dan Keselamatan Operasional Sistem Distribusi Listrik pada Gedung Bertingkat
This study aims to evaluate power quality and analyze its impact on the reliability of electrical distribution systems in a high-rise building. The study employed a quantitative descriptive method through field measurements using a Power Quality Analyzer PEL 103 Chauvin Arnoux installed on the distribution panels of ten floors. The observed parameters included voltage, voltage unbalance, current unbalance, power factor, and total harmonic distortion of voltage (THDv) and current (THDi). The results indicate that the voltage level (229.18–235.02 V), voltage unbalance (0.31–1.17%), power factor (0.86–0.99), and THDv (<5%) comply with IEC 61000, SNI IEC 61000, Permen ESDM No. 04 of 2009, and IEEE 519-2014/2022 standards. However, current unbalance exceeded the permissible limit of 20% on seven floors, and THDi values on several floors exceeded 15%, indicating the presence of nonlinear loads. It can be concluded that the electrical distribution system of the high-rise building exhibits good voltage stability; however, load balancing among phases and harmonic mitigation measures are necessary to maintain the long-term reliability and safety of the electrical installation. Keywords: Electrical Distribution, Harmonics, High-Rise Building, Power Factor, Power Quality.
- Open Access
- 30 June 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 9 (2) , 111-119
Tinjauan Komprehensif tentang Material Berbasis Fe dalam Jurnal Thermoelectric Full-Heusler
This study aims to conduct a comprehensive review of the development of iron-based thermoelectric materials with an emphasis on crystal structure, electron-phonon transport mechanisms, and efforts to improve power factor and figure of merit (ZT) values. This methods study reviews literatures discussing materials such as FeSi, FeSb₂, Heusler and Half-Heusler alloys, and Fe-based nanocomposites that have significant potential as environmentally friendly thermoelectric materials. The results of the study indicate that iron-based materials have several advantages, including abundant availability, good thermal stability, non-toxicity, and suitability for applications in the medium to high temperature range. In FeSi and FeSb₂ systems, the improvement of thermoelectric performance is strongly influenced by strong electron interactions and phonon scattering mechanisms, which can be optimized through nanostructuring, doping, and energy band engineering techniques. Meanwhile, Fe-based Full-Heusler and Half-Heusler materials show great potential for performance improvement through band engineering approaches, controlling the charge carrier concentration, and reducing the lattice thermal conductivity through phonon scattering strategies. This study also identified several key challenges still faced, such as low energy conversion efficiency, sensitivity to temperature changes, and the complexity of balancing electrical conductivity and phonon scattering processes. Overall, the results of this study confirm that Fe-based thermoelectric materials are promising candidates for supporting sustainable energy development. However, a multidisciplinary materials engineering approach is needed to achieve optimal performance for widespread industrial application. Keywords: , Iron (Fe) based, Full Heusler, Half Heusler, Figure of Merit (ZT), Thermoelectric material.
- 30 June 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 9 (2) , 111-119
Open AccessTinjauan Komprehensif tentang Material Berbasis Fe dalam Jurnal Thermoelectric Full-Heusler
This study aims to conduct a comprehensive review of the development of iron-based thermoelectric materials with an emphasis on crystal structure, electron-phonon transport mechanisms, and efforts to improve power factor and figure of merit (ZT) values. This methods study reviews literatures discussing materials such as FeSi, FeSb₂, Heusler and Half-Heusler alloys, and Fe-based nanocomposites that have significant potential as environmentally friendly thermoelectric materials. The results of the study indicate that iron-based materials have several advantages, including abundant availability, good thermal stability, non-toxicity, and suitability for applications in the medium to high temperature range. In FeSi and FeSb₂ systems, the improvement of thermoelectric performance is strongly influenced by strong electron interactions and phonon scattering mechanisms, which can be optimized through nanostructuring, doping, and energy band engineering techniques. Meanwhile, Fe-based Full-Heusler and Half-Heusler materials show great potential for performance improvement through band engineering approaches, controlling the charge carrier concentration, and reducing the lattice thermal conductivity through phonon scattering strategies. This study also identified several key challenges still faced, such as low energy conversion efficiency, sensitivity to temperature changes, and the complexity of balancing electrical conductivity and phonon scattering processes. Overall, the results of this study confirm that Fe-based thermoelectric materials are promising candidates for supporting sustainable energy development. However, a multidisciplinary materials engineering approach is needed to achieve optimal performance for widespread industrial application. Keywords: , Iron (Fe) based, Full Heusler, Half Heusler, Figure of Merit (ZT), Thermoelectric material.
- Open Access
- 30 June 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 9 (2) , 90-101
Inovasi Komprehensif Komposit Berbasis Polimer dan Serat Daur Ulang untuk Infrastruktur Berketahanan Tinggi dan Berkelanjutan : ”Sebuah Tinjauan”
Permintaan yang terus meningkat akan material konstruksi yang ramah lingkungan, berdaya tahan tinggi, dan berkinerja mekanis unggul telah mendorong pergeseran paradigma dalam teknik mesin. Penelitian ini menyajikan sintesis komprehensif dari inovasi material komposit berbasis polimer dan serat, yang mengintegrasikan aspek keberlanjutan, kinerja struktural, dan pemodelan prediktif. Penelitian ini mengadopsi pendekatan Ekonomi Sirkular yang kuat, memvalidasi penggunaan limbah industri dan konsumen sebagai pengisi fungsional. Pemanfaatan limbah, seperti busa polistirena daur ulang, serbuk perlit, serbuk karet ban bekas (tyre crumbs), dan agregat beton daur ulang (Recycled Aggregate - RA), telah terbukti efektif dalam memproduksi Komposit Polimer-Semen (PCC) dan Beton Polimer (PC) yang ringan namun berkinerja tinggi. Secara khusus, komposit yang mengandung Polistirena/Serbuk Karet menunjukkan peningkatan signifikan dalam kekuatan tekan (hingga 22.2%), sementara PC dengan RA menunjukkan kuat tekan yang luar biasa (hingga 96 MPa) karena optimasi mikrostruktur dan pembentukan lapisan resin pelindung. Selain itu, pemanfaatan serat alami yang berkelanjutan, seperti serat daun kurma dan serat rami (Hemp Fiber), telah divalidasi sebagai alternatif penguatan yang efektif dan ramah lingkungan. Optimalisasi komposisi material, termasuk rasio volume resin dan perlakuan permukaan pada pengisi (misalnya serbuk gergaji), lebih lanjut memastikan peningkatan stabilitas dan sifat mekanis material.Dari sisi aplikasi struktural, material komposit menunjukkan peran penting dalam perkuatan dan pengembangan elemen baru. Penggunaan Carbon Fiber-Reinforced Polymer (CFRP), termasuk aplikasi prategang, terbukti sangat efektif untuk perbaikan balok beton bertulang yang mengalami korosi dan penguatan balok komposit baja-beton. Selain itu, elemen struktural inovatif seperti Tiang Komposit Tabung FRP berisi Beton (CFFT) telah diuji kinerjanya di bawah beban lateral siklik, dan Komposit Kayu-Beton (TCC) dengan matriks epoksi memberikan ikatan geser yang unggul dibandingkan matriks lain. Terakhir, pemanfaatan model prediktif canggih, seperti algoritma Extreme Gradient Boosting (XGBoost), telah memungkinkan perkiraan sifat mekanis dengan akurasi tinggi (R² hingga 0.981), memfasilitasi desain material yang didorong oleh data. Secara kolektif, temuan ini mengukuhkan komposit berbasis polimer dan serat sebagai solusi material masa depan, secara simultan mendukung keberlanjutan melalui daur ulang limbah skala besar dan memastikan ketahanan mekanis luar biasa dari infrastruktur sipil. Kata Kunci: Komposit Berbasis Polimer, Konstruksi Berkelanjutan, Daur Ulang Limbah, Kuat Tekan, Perkuatan CFRP, Agregat Daur Ulang, Beton Serat (FRP)
- 30 June 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 9 (2) , 90-101
Open AccessInovasi Komprehensif Komposit Berbasis Polimer dan Serat Daur Ulang untuk Infrastruktur Berketahanan Tinggi dan Berkelanjutan : ”Sebuah Tinjauan”
Permintaan yang terus meningkat akan material konstruksi yang ramah lingkungan, berdaya tahan tinggi, dan berkinerja mekanis unggul telah mendorong pergeseran paradigma dalam teknik mesin. Penelitian ini menyajikan sintesis komprehensif dari inovasi material komposit berbasis polimer dan serat, yang mengintegrasikan aspek keberlanjutan, kinerja struktural, dan pemodelan prediktif. Penelitian ini mengadopsi pendekatan Ekonomi Sirkular yang kuat, memvalidasi penggunaan limbah industri dan konsumen sebagai pengisi fungsional. Pemanfaatan limbah, seperti busa polistirena daur ulang, serbuk perlit, serbuk karet ban bekas (tyre crumbs), dan agregat beton daur ulang (Recycled Aggregate - RA), telah terbukti efektif dalam memproduksi Komposit Polimer-Semen (PCC) dan Beton Polimer (PC) yang ringan namun berkinerja tinggi. Secara khusus, komposit yang mengandung Polistirena/Serbuk Karet menunjukkan peningkatan signifikan dalam kekuatan tekan (hingga 22.2%), sementara PC dengan RA menunjukkan kuat tekan yang luar biasa (hingga 96 MPa) karena optimasi mikrostruktur dan pembentukan lapisan resin pelindung. Selain itu, pemanfaatan serat alami yang berkelanjutan, seperti serat daun kurma dan serat rami (Hemp Fiber), telah divalidasi sebagai alternatif penguatan yang efektif dan ramah lingkungan. Optimalisasi komposisi material, termasuk rasio volume resin dan perlakuan permukaan pada pengisi (misalnya serbuk gergaji), lebih lanjut memastikan peningkatan stabilitas dan sifat mekanis material.Dari sisi aplikasi struktural, material komposit menunjukkan peran penting dalam perkuatan dan pengembangan elemen baru. Penggunaan Carbon Fiber-Reinforced Polymer (CFRP), termasuk aplikasi prategang, terbukti sangat efektif untuk perbaikan balok beton bertulang yang mengalami korosi dan penguatan balok komposit baja-beton. Selain itu, elemen struktural inovatif seperti Tiang Komposit Tabung FRP berisi Beton (CFFT) telah diuji kinerjanya di bawah beban lateral siklik, dan Komposit Kayu-Beton (TCC) dengan matriks epoksi memberikan ikatan geser yang unggul dibandingkan matriks lain. Terakhir, pemanfaatan model prediktif canggih, seperti algoritma Extreme Gradient Boosting (XGBoost), telah memungkinkan perkiraan sifat mekanis dengan akurasi tinggi (R² hingga 0.981), memfasilitasi desain material yang didorong oleh data. Secara kolektif, temuan ini mengukuhkan komposit berbasis polimer dan serat sebagai solusi material masa depan, secara simultan mendukung keberlanjutan melalui daur ulang limbah skala besar dan memastikan ketahanan mekanis luar biasa dari infrastruktur sipil. Kata Kunci: Komposit Berbasis Polimer, Konstruksi Berkelanjutan, Daur Ulang Limbah, Kuat Tekan, Perkuatan CFRP, Agregat Daur Ulang, Beton Serat (FRP)
- Open Access
- 30 June 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 9 (2) , 120-129
Analisis Hubungan Kebaikan Drosophila SP. dari Daerah Batu, Tulungagung dan Jombang Menggunakan Indeks Kesamaan dan Metode Dendogram
Abstrak: Drosophila sp. is a genus of organisms with a wide distribution pattern. This research aims to determine the relationship between Drosophila species in three areas, namely Batu, Tulungagung and Jombang. The research was carried out from April to June 2020 at three locations in these three regions. The samples in this study were Drosophila caught from 3 areas in the following areas: Batu, Jombang, and Tuluangung. Data was obtained from observing the morphological characteristics of captured Drosophila species originating from these three regions. The similarity analysis obtained is then carried out using a similarity index and displayed in the form of a dendogram. The final analysis displays the taxonomic dendogram findings. The results of the research show that the closest relationship between catches from the Batu area and the Tulungungung area is 0.966, which has an association coefficient value close to 1.00. This shows that there is a close relationship between species originating from the Batu and Jombang areas. Keywords: Kindness relations, Similarity Index, Dendogram Method
- 30 June 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 9 (2) , 120-129
Open AccessAnalisis Hubungan Kebaikan Drosophila SP. dari Daerah Batu, Tulungagung dan Jombang Menggunakan Indeks Kesamaan dan Metode Dendogram
Abstrak: Drosophila sp. is a genus of organisms with a wide distribution pattern. This research aims to determine the relationship between Drosophila species in three areas, namely Batu, Tulungagung and Jombang. The research was carried out from April to June 2020 at three locations in these three regions. The samples in this study were Drosophila caught from 3 areas in the following areas: Batu, Jombang, and Tuluangung. Data was obtained from observing the morphological characteristics of captured Drosophila species originating from these three regions. The similarity analysis obtained is then carried out using a similarity index and displayed in the form of a dendogram. The final analysis displays the taxonomic dendogram findings. The results of the research show that the closest relationship between catches from the Batu area and the Tulungungung area is 0.966, which has an association coefficient value close to 1.00. This shows that there is a close relationship between species originating from the Batu and Jombang areas. Keywords: Kindness relations, Similarity Index, Dendogram Method
- Open Access
- 30 June 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 9 (2) , 102-110
Strategi Total Productive Maintenance (TPM) untuk Meningkatkan Kinerja Mesin PKS PT Tri Cahaya Sawit
This study aims to analyze the implementation of TPM strategies in improving machine performance in Palm Oil Mills (PKS). Problems that often occur in PKS are high machine downtime, low equipment effectiveness, and operational disruptions that impact productivity decline. The methods used in this study include identifying machine failures, measuring Overall Equipment Effectiveness (OEE), and implementing TPM pillars such as autonomous maintenance, planned maintenance, and focused improvement. The results show that the implementation of TPM can improve machine reliability, reduce the frequency of breakdowns, and significantly increase the OEE value. In addition, operator involvement in routine maintenance activities also increases production process efficiency and reduces maintenance costs. Thus, the TPM strategy can be an effective solution in improving machine performance and operational productivity in Palm Oil Mills. Keywords: Total Productive Maintenance, TPM, Overall Equipment Effectiveness, Machine Performance, Palm Oil Mill.
- 30 June 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 9 (2) , 102-110
Open AccessStrategi Total Productive Maintenance (TPM) untuk Meningkatkan Kinerja Mesin PKS PT Tri Cahaya Sawit
This study aims to analyze the implementation of TPM strategies in improving machine performance in Palm Oil Mills (PKS). Problems that often occur in PKS are high machine downtime, low equipment effectiveness, and operational disruptions that impact productivity decline. The methods used in this study include identifying machine failures, measuring Overall Equipment Effectiveness (OEE), and implementing TPM pillars such as autonomous maintenance, planned maintenance, and focused improvement. The results show that the implementation of TPM can improve machine reliability, reduce the frequency of breakdowns, and significantly increase the OEE value. In addition, operator involvement in routine maintenance activities also increases production process efficiency and reduces maintenance costs. Thus, the TPM strategy can be an effective solution in improving machine performance and operational productivity in Palm Oil Mills. Keywords: Total Productive Maintenance, TPM, Overall Equipment Effectiveness, Machine Performance, Palm Oil Mill.
- Open Access
- 30 June 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 9 (2) , 130-140
Analisis Pengaruh Spoiler terhadap Aerodinamika Mobil Jenis Urban dengan Simulasi Computational Fluid Dynamics
This study aims to analyze the effect of spoiler size variations on the Coefficient of Drag (CD) and Coefficient of Lift (CL), as well as to investigate the characteristics of velocity, pressure, and turbulent kinetic energy contours in an urban-type vehicle under various airflow velocities. The research employed a Computational Fluid Dynamics (CFD) simulation approach using ANSYS Workbench software, while the urban-type vehicle model was designed using Autodesk Inventor. Three spoiler dimensions were evaluated, namely 2200 × 500 mm, 2200 × 600 mm, and 2200 × 700 mm, under airflow velocities of 60 km/h, 80 km/h, and 100 km/h. The simulation results indicate that spoiler size variations significantly affect the aerodynamic characteristics of the vehicle. The 2200 × 500 mm and 2200 × 600 mm spoilers exhibited better aerodynamic performance by generating downforce, which contributes to improved vehicle stability. In contrast, the 2200 × 700 mm spoiler produced an increase in Lift Force that may reduce vehicle stability. Furthermore, contour analysis revealed the formation of wake regions and an increase in turbulence intensity behind the vehicle as the spoiler size and airflow velocity increased. Therefore, selecting an appropriate spoiler dimension can improve the aerodynamic performance and stability of urban-type vehicles. Keywords: Aerodynamics, Computational Fluid Dynamics (CFD), Coefficient of Drag (CD), Coefficient of Lift (CL), Spoiler, Urban-Type Vehicle.
- 30 June 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 9 (2) , 130-140
Open AccessAnalisis Pengaruh Spoiler terhadap Aerodinamika Mobil Jenis Urban dengan Simulasi Computational Fluid Dynamics
This study aims to analyze the effect of spoiler size variations on the Coefficient of Drag (CD) and Coefficient of Lift (CL), as well as to investigate the characteristics of velocity, pressure, and turbulent kinetic energy contours in an urban-type vehicle under various airflow velocities. The research employed a Computational Fluid Dynamics (CFD) simulation approach using ANSYS Workbench software, while the urban-type vehicle model was designed using Autodesk Inventor. Three spoiler dimensions were evaluated, namely 2200 × 500 mm, 2200 × 600 mm, and 2200 × 700 mm, under airflow velocities of 60 km/h, 80 km/h, and 100 km/h. The simulation results indicate that spoiler size variations significantly affect the aerodynamic characteristics of the vehicle. The 2200 × 500 mm and 2200 × 600 mm spoilers exhibited better aerodynamic performance by generating downforce, which contributes to improved vehicle stability. In contrast, the 2200 × 700 mm spoiler produced an increase in Lift Force that may reduce vehicle stability. Furthermore, contour analysis revealed the formation of wake regions and an increase in turbulence intensity behind the vehicle as the spoiler size and airflow velocity increased. Therefore, selecting an appropriate spoiler dimension can improve the aerodynamic performance and stability of urban-type vehicles. Keywords: Aerodynamics, Computational Fluid Dynamics (CFD), Coefficient of Drag (CD), Coefficient of Lift (CL), Spoiler, Urban-Type Vehicle.
- Open Access
- 30 June 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 9 (2) , 78-89
Studi Literatur Analisis Keandalan Komponen Industri dan Penerbangan
This study aims to map the analysis methodologies and the main triggers of technical component failure in the mechanical systems of the manufacturing and aviation industries. The method used is a Systematic Literature Review focusing on analysis parameters from Weibull distribution, Failure Mode and Effects Analysis (FMEA), Fault Tree Analysis (FTA), and Reliability-Centered Maintenance (RCM). The results of the study indicate that the majority of critical devices, especially hydraulic systems and actuators, have entered the wear-out phase. This is statistically proven through Weibull distribution parameters that are consistently above one (β > 1) with a contrasting priority where aviation prioritizes regulatory safety (MEL) while manufacturing focuses on cost efficiency. In conclusion, determining an accurate Mean Time to Failure (MTTF) is key to maintaining system integrity while reducing operational expenses in both sectors. Keywords: Component Reliability, Mean Time to Failure, Root Cause Analysis, Systematic Literature Review, Weibull Distribution
- 30 June 2026
- Published by IPM2KPE in Science and Physics Education Journal (SPEJ
- Vol. 9 (2) , 78-89
Open AccessStudi Literatur Analisis Keandalan Komponen Industri dan Penerbangan
This study aims to map the analysis methodologies and the main triggers of technical component failure in the mechanical systems of the manufacturing and aviation industries. The method used is a Systematic Literature Review focusing on analysis parameters from Weibull distribution, Failure Mode and Effects Analysis (FMEA), Fault Tree Analysis (FTA), and Reliability-Centered Maintenance (RCM). The results of the study indicate that the majority of critical devices, especially hydraulic systems and actuators, have entered the wear-out phase. This is statistically proven through Weibull distribution parameters that are consistently above one (β > 1) with a contrasting priority where aviation prioritizes regulatory safety (MEL) while manufacturing focuses on cost efficiency. In conclusion, determining an accurate Mean Time to Failure (MTTF) is key to maintaining system integrity while reducing operational expenses in both sectors. Keywords: Component Reliability, Mean Time to Failure, Root Cause Analysis, Systematic Literature Review, Weibull Distribution