Laboratory Service
Published by Media Sphere Publishing Group
- Scilit
- Clinical Laboratory Science
- Hematology
- Genetics & Genomics
- Immunology
- Vitamin Metabolism
Publications Analysis
Publications in 2016-2026
Open Access Publications in 2016-2026
- Total Citations
- 12
- Total Publications
- 65
- Average Citations
- 0.18
- Cited Publications
- 12
- Cited Publications %
- 18.5%
- Self Citations
- 6
- Self Citations %
- 50%
- Q1
- 0
- Med
- 0
- Q3
- 1
- 99%
- 3.4
- Max
- 4
- Citing Source Titles
- Citing Publishers
Latest Publications
- 26 November 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (3)
The results of the assessment of the total antioxidant activity in blood and urine using the domestic test system “Total Antioxidant Status”
Introduction. The antioxidant system is represented by many different individual compounds. A number of methods have been proposed to assess their individual contribution, but the most appropriate approach is to use methods that allow for a cumulative assessment of the activity of all antioxidant compounds and the total antioxidant status (TAS). Objective. To perform a comparative assessment of the TAS of blood serum and urine of healthy people. Material and methods. A single-stage study of paired blood serum and urine samples from 54 healthy adult workers (25 men, 29 women) was performed. The total activity of all antioxidants was assessed using the test system “Total Antioxidant Status” (Vector-Best JSC, Russia). Results. The average TAS values in all blood serum samples studied were 1.59±0.14 (95% CI 1.56—1.63) mmol/L, the lowest value was 1.29 mmol/l, the highest was 1.85 mmol/l and corresponded to the manufacturer’s data. The results of the study of TAS in urine showed 3.43 times higher values. The median urinary TAS was 5.46 mmol/L, and the interquartile range was 3.56—8.1 mmol; the lowest value was 1.92 mmol/L, the highest was 16.68 mmol/L. There were no differences in TAS between men and women in the blood serum or urine of the examined individuals. In the correlation analysis of TAS in biological fluids, there was no relationship between the TAS of blood serum and urine (R=–0.078, p=0.577). A noticeable direct correlation has been established between the TAS of urine and its specific gravity (R=0.519, p<0.001). Conclusion. The possibility of using the investigated test system is demonstrated not only for the assessment of TAS in blood serum, but also for urinalysis. A possible reason for the high TAS of urine is the high level of an antioxidant such as uric acid.
- 26 November 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (3)
The results of the assessment of the total antioxidant activity in blood and urine using the domestic test system “Total Antioxidant Status”
Introduction. The antioxidant system is represented by many different individual compounds. A number of methods have been proposed to assess their individual contribution, but the most appropriate approach is to use methods that allow for a cumulative assessment of the activity of all antioxidant compounds and the total antioxidant status (TAS). Objective. To perform a comparative assessment of the TAS of blood serum and urine of healthy people. Material and methods. A single-stage study of paired blood serum and urine samples from 54 healthy adult workers (25 men, 29 women) was performed. The total activity of all antioxidants was assessed using the test system “Total Antioxidant Status” (Vector-Best JSC, Russia). Results. The average TAS values in all blood serum samples studied were 1.59±0.14 (95% CI 1.56—1.63) mmol/L, the lowest value was 1.29 mmol/l, the highest was 1.85 mmol/l and corresponded to the manufacturer’s data. The results of the study of TAS in urine showed 3.43 times higher values. The median urinary TAS was 5.46 mmol/L, and the interquartile range was 3.56—8.1 mmol; the lowest value was 1.92 mmol/L, the highest was 16.68 mmol/L. There were no differences in TAS between men and women in the blood serum or urine of the examined individuals. In the correlation analysis of TAS in biological fluids, there was no relationship between the TAS of blood serum and urine (R=–0.078, p=0.577). A noticeable direct correlation has been established between the TAS of urine and its specific gravity (R=0.519, p<0.001). Conclusion. The possibility of using the investigated test system is demonstrated not only for the assessment of TAS in blood serum, but also for urinalysis. A possible reason for the high TAS of urine is the high level of an antioxidant such as uric acid.
- 26 November 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (3)
News in molecular biology. Digest of scientific publications. Issue 6
This brief overview presents scientific publications released between the end of the second quarter and the beginning of the third quarter of 2026. The publications featured in this review have sparked discussions within both professional circles and the media, including In Russia. In particular, the debate regarding embryo genome editing originally triggered by He Jiankui’s presentation at the 2018 Human Genome Editing conference has resurfaced. Other topics driving discussion include FDA decisions on new application procedures for gene therapy and cell-based products, the development of novel personalized therapy approaches, and experiments in the field of transfusion medicine.hi.
- 26 November 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (3)
News in molecular biology. Digest of scientific publications. Issue 6
This brief overview presents scientific publications released between the end of the second quarter and the beginning of the third quarter of 2026. The publications featured in this review have sparked discussions within both professional circles and the media, including In Russia. In particular, the debate regarding embryo genome editing originally triggered by He Jiankui’s presentation at the 2018 Human Genome Editing conference has resurfaced. Other topics driving discussion include FDA decisions on new application procedures for gene therapy and cell-based products, the development of novel personalized therapy approaches, and experiments in the field of transfusion medicine.hi.
- 26 November 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (3)
Method-dependent drug interference in measuring serum creatinine in a deeply premature newborn: a clinical case and literature review
Background. Drug interference is an underappreciated cause of spurious laboratory test results, documented in 43% of hospitalised patients. In very preterm neonates receiving multidrug infusion therapy, the risk of diagnostic errors is particularly high due to low absolute analyte concentrations, age-dependent reference intervals, and a 30—50% incidence of acute kidney injury. Objective. To present a clinical case of method-dependent drug interference in serum creatinine measurement in such a patient and to propose a laboratory algorithm for artefact identification based on a literature review. Material and methods. Serum samples from a paediatric patient were studied. Two closed analytical systems (fully traceable to IDMS) were compared: the enzymatic method and the colorimetric Jaffe method. A preterm neonate (gestational age 28 weeks, birth weight <1000 g) received continuous infusions of ethamsylate and dobutamine. Results. Parallel creatinine measurements showed striking discrepancies: the colorimetric Jaffe method gave values of 206—236 µmol/L, whereas the enzymatic method (Trinder reaction) yielded only 76—120 µmol/L, which was inconsistent with the clinical picture. Reaction curve analysis and a serum dilution test (1:4) confirmed suppression of the enzymatic reaction caused by the reducing properties of ethamsylate and dobutamine, which compete with peroxidase for hydrogen peroxide. Conclusion. In very preterm neonates receiving ethamsylate and dobutamine infusions, enzymatic creatinine determination yields persistently falsely low values, whereas the Jaffe method remains diagnostically reliable. A serum dilution test can identify the artefact, and preanalytical prevention minimises the risk of errors.
- 26 November 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (3)
Method-dependent drug interference in measuring serum creatinine in a deeply premature newborn: a clinical case and literature review
Background. Drug interference is an underappreciated cause of spurious laboratory test results, documented in 43% of hospitalised patients. In very preterm neonates receiving multidrug infusion therapy, the risk of diagnostic errors is particularly high due to low absolute analyte concentrations, age-dependent reference intervals, and a 30—50% incidence of acute kidney injury. Objective. To present a clinical case of method-dependent drug interference in serum creatinine measurement in such a patient and to propose a laboratory algorithm for artefact identification based on a literature review. Material and methods. Serum samples from a paediatric patient were studied. Two closed analytical systems (fully traceable to IDMS) were compared: the enzymatic method and the colorimetric Jaffe method. A preterm neonate (gestational age 28 weeks, birth weight <1000 g) received continuous infusions of ethamsylate and dobutamine. Results. Parallel creatinine measurements showed striking discrepancies: the colorimetric Jaffe method gave values of 206—236 µmol/L, whereas the enzymatic method (Trinder reaction) yielded only 76—120 µmol/L, which was inconsistent with the clinical picture. Reaction curve analysis and a serum dilution test (1:4) confirmed suppression of the enzymatic reaction caused by the reducing properties of ethamsylate and dobutamine, which compete with peroxidase for hydrogen peroxide. Conclusion. In very preterm neonates receiving ethamsylate and dobutamine infusions, enzymatic creatinine determination yields persistently falsely low values, whereas the Jaffe method remains diagnostically reliable. A serum dilution test can identify the artefact, and preanalytical prevention minimises the risk of errors.
- 26 November 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (3)
Digital coprology: modern automated analyzers and AI technologies in laboratory diagnostics. Ready-made solution or a promising future?
Automation of stool examination is becoming one of the most significant areas in the development of clinical laboratory diagnostics, although the biomaterial itself remains extremely difficult to standardize. Traditional parasitological examination of stool largely depends on the quality of sample preparation, the specialist’s qualifications, and the subjective identification of detected objects. For this reason, digital microscopy and artificial intelligence algorithms are regarded as tools that may change the way such examinations are performed. This review systematizes current data on automated fecal analyzers and AI-supported platforms used to detect helminth eggs, protozoan cysts, and other microscopic structures. The KU-F40, MISPA-F30, AiDx Assist, the combined Techcyte/Grundium workflow, as well as neural network approaches based on YOLOv5 and ResNet-34 are considered. Particular attention is paid to the diagnostic sensitivity and specificity of these systems, their agreement with conventional microscopy, and the possibility of creating a digital archive and performing remote expert validation. It is shown that automation may improve the reproducibility of results, reduce analysis time, and decrease the influence of the human factor, especially in laboratories with a high sample throughput. At the same time, the advantages of the digital approach are evident not only in routine diagnostics, but also in specialist training, the development of standardized image libraries, the review of complex cases, and the organization of telemedicine consultations. For the Russian laboratory service, this is becoming particularly relevant against the background of laboratory test centralization, personnel shortages, and the need to standardize parasitological diagnostics across clinical laboratories. At the same time, AI platforms should not yet be regarded as a complete replacement for a clinical laboratory diagnostics physician: the most rational approach remains a hybrid model, in which an automated solution performs primary screening, while the laboratory physician validates positive and doubtful results. The article also discusses preanalytical limitations, requirements for local validation, regulatory issues, economic aspects of implementation, and prospects for the use of digital coprology in centralized laboratories of the Russian Federation. The need for multicenter studies, the development of unified quality control criteria for obtained results, and the creation of methodological recommendations for the safe implementation of AI technologies in routine laboratory practice is emphasized.
- 26 November 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (3)
Digital coprology: modern automated analyzers and AI technologies in laboratory diagnostics. Ready-made solution or a promising future?
Automation of stool examination is becoming one of the most significant areas in the development of clinical laboratory diagnostics, although the biomaterial itself remains extremely difficult to standardize. Traditional parasitological examination of stool largely depends on the quality of sample preparation, the specialist’s qualifications, and the subjective identification of detected objects. For this reason, digital microscopy and artificial intelligence algorithms are regarded as tools that may change the way such examinations are performed. This review systematizes current data on automated fecal analyzers and AI-supported platforms used to detect helminth eggs, protozoan cysts, and other microscopic structures. The KU-F40, MISPA-F30, AiDx Assist, the combined Techcyte/Grundium workflow, as well as neural network approaches based on YOLOv5 and ResNet-34 are considered. Particular attention is paid to the diagnostic sensitivity and specificity of these systems, their agreement with conventional microscopy, and the possibility of creating a digital archive and performing remote expert validation. It is shown that automation may improve the reproducibility of results, reduce analysis time, and decrease the influence of the human factor, especially in laboratories with a high sample throughput. At the same time, the advantages of the digital approach are evident not only in routine diagnostics, but also in specialist training, the development of standardized image libraries, the review of complex cases, and the organization of telemedicine consultations. For the Russian laboratory service, this is becoming particularly relevant against the background of laboratory test centralization, personnel shortages, and the need to standardize parasitological diagnostics across clinical laboratories. At the same time, AI platforms should not yet be regarded as a complete replacement for a clinical laboratory diagnostics physician: the most rational approach remains a hybrid model, in which an automated solution performs primary screening, while the laboratory physician validates positive and doubtful results. The article also discusses preanalytical limitations, requirements for local validation, regulatory issues, economic aspects of implementation, and prospects for the use of digital coprology in centralized laboratories of the Russian Federation. The need for multicenter studies, the development of unified quality control criteria for obtained results, and the creation of methodological recommendations for the safe implementation of AI technologies in routine laboratory practice is emphasized.
- 26 November 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (3)
A laboratory case of delipidation of a blood sample with lipemia for hematological analysis
The pre-analytical stage in laboratory practice critically affects the reliability of research results. Blood samples with signs of chylemia, hemolysis, or ictericity arriving at the laboratory can cause significant distortion of laboratory test results. Lipemia, in particular, affects optical density when measuring hemoglobin concentration, which entails errors in obtaining the result of a complete blood count, and, consequently, in diagnosis and therapy monitoring. At the same time, existing guidelines [1] lack protocols for pre-treatment of lipemic samples for hematological testing, which underscores the relevance of developing and validating effective delipidation methods. The aim of the study was to validate the blood sample delipidation method by Zeng S.G. et al. [2] for the correction of hemoglobin measurement on an automated hematology analyzer. Materials and methods. Biochemical and hematological analyses were performed on a blood sample from patient A. (40 years old, diagnosis — diabetes mellitus), in whom chylous sample was detected during fasting blood collection. Lipid profile analysis was performed using a COBAS INTEGRA 400 plus analyzer; hematological testing was performed on a UniCel DxH 800 (Beckman Coulter) instrument. The analysis was performed twice: before and after sample preparation according to the Zeng S.G. method. Sample preparation was as follows: the sample with K3EDTA was centrifuged at 500 rpm for 15 minutes, then the lipemic plasma was removed and the volume was replenished with an equal amount of physiological saline. Results. In the chylous sample, the hemoglobin level reached 270 g/L, which is above the reference values. Due to lipemia, MCH and MCHC parameters were also overestimated. After delipidation, the hemoglobin concentration decreased to 119 g/L; a decrease in other hematological parameters was also noted: leukocytes from 9.5 to 4.8·109/L, platelets from 277 to 146·106/L, erythrocytes from 4.35 to 3.59 ·109/L. Hypertriglyceridemia was confirmed by the triglyceride level of 132.05 mmol/L (reference values up to 2.3 mmol/L). Conclusions. The blood delipidation method by Zeng S.G. [2] allows obtaining correct hemoglobin values in chylous samples, but causes a decrease in blood cell parameters, which limits its application for performing a complete blood count. Further studies are needed to adapt this method and correct the measurement of all hematological parameters.
- 26 November 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (3)
A laboratory case of delipidation of a blood sample with lipemia for hematological analysis
The pre-analytical stage in laboratory practice critically affects the reliability of research results. Blood samples with signs of chylemia, hemolysis, or ictericity arriving at the laboratory can cause significant distortion of laboratory test results. Lipemia, in particular, affects optical density when measuring hemoglobin concentration, which entails errors in obtaining the result of a complete blood count, and, consequently, in diagnosis and therapy monitoring. At the same time, existing guidelines [1] lack protocols for pre-treatment of lipemic samples for hematological testing, which underscores the relevance of developing and validating effective delipidation methods. The aim of the study was to validate the blood sample delipidation method by Zeng S.G. et al. [2] for the correction of hemoglobin measurement on an automated hematology analyzer. Materials and methods. Biochemical and hematological analyses were performed on a blood sample from patient A. (40 years old, diagnosis — diabetes mellitus), in whom chylous sample was detected during fasting blood collection. Lipid profile analysis was performed using a COBAS INTEGRA 400 plus analyzer; hematological testing was performed on a UniCel DxH 800 (Beckman Coulter) instrument. The analysis was performed twice: before and after sample preparation according to the Zeng S.G. method. Sample preparation was as follows: the sample with K3EDTA was centrifuged at 500 rpm for 15 minutes, then the lipemic plasma was removed and the volume was replenished with an equal amount of physiological saline. Results. In the chylous sample, the hemoglobin level reached 270 g/L, which is above the reference values. Due to lipemia, MCH and MCHC parameters were also overestimated. After delipidation, the hemoglobin concentration decreased to 119 g/L; a decrease in other hematological parameters was also noted: leukocytes from 9.5 to 4.8·109/L, platelets from 277 to 146·106/L, erythrocytes from 4.35 to 3.59 ·109/L. Hypertriglyceridemia was confirmed by the triglyceride level of 132.05 mmol/L (reference values up to 2.3 mmol/L). Conclusions. The blood delipidation method by Zeng S.G. [2] allows obtaining correct hemoglobin values in chylous samples, but causes a decrease in blood cell parameters, which limits its application for performing a complete blood count. Further studies are needed to adapt this method and correct the measurement of all hematological parameters.
- 26 November 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (3)
Evaluation of proteinuria parameter stability in Acti-Fine vacuum containers with different preservatives
Background. The preanalytical phase is a critical factor in ensuring the quality of laboratory diagnostics for chronic kidney disease (CKD). Measurement of urinary protein, creatinine, and their ratio (protein/creatinine) is the key method for CKD screening and monitoring. The updated 2023 EFLM guidelines have tightened requirements for urine storage conditions; however, in routine practice, alternative preservation methods are often needed. Objective. To comparatively evaluate the stability of urinary protein, creatinine, and their ratio in Acti-Fine vacuum containers with boric acid and a chlorhexidine-based preservative during storage at +20 °C for 7 days. Material and methods. A total of 40 urine samples from patients with therapeutic and nephrological profiles were studied. Each sample was aliquoted into three container types: without additives (control, +4 °C), with boric acid (+20 °C), and with chlorhexidine-based preservative (+20 °C). Protein (pyrogallol red method) and creatinine (IDMS-standardized Jaffe method) concentrations were measured on an AU480 analyzer (Beckman Coulter) at 0, 24, 72, 120, and 168 hours. Statistical analysis was performed using MedCalc V20.218 (paired t-test, Pearson correlation, relative bias calculation). Results. In preservative containers, bias did not exceed +4.5% for protein, +2.0% for creatinine, and +4.5% for the protein/creatinine ratio (p>0.05). Although statistically significant differences were observed for protein at 72 h (p=0.038), the magnitude of bias (+4.5%) remained within the clinically acceptable range. In boric acid containers, protein decreased to –3.6% (p=0.049 at 168 h) and creatinine to –6.9% (p0.05). Correlation with the control was r>0.9988. No statistically significant differences were found across all ranges of initial proteinuria (from normal to ≥3.0 g/L). Conclusion. Acti-Fine containers with chlorhexidine-based preservative ensure stability of all studied parameters at +20 °C for 7 days. Boric acid containers are suitable for clinical use but require consideration of systematic creatinine decrease during long-term storage. The protein/creatinine ratio remains highly stable in both container types.
- 26 November 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (3)
Evaluation of proteinuria parameter stability in Acti-Fine vacuum containers with different preservatives
Background. The preanalytical phase is a critical factor in ensuring the quality of laboratory diagnostics for chronic kidney disease (CKD). Measurement of urinary protein, creatinine, and their ratio (protein/creatinine) is the key method for CKD screening and monitoring. The updated 2023 EFLM guidelines have tightened requirements for urine storage conditions; however, in routine practice, alternative preservation methods are often needed. Objective. To comparatively evaluate the stability of urinary protein, creatinine, and their ratio in Acti-Fine vacuum containers with boric acid and a chlorhexidine-based preservative during storage at +20 °C for 7 days. Material and methods. A total of 40 urine samples from patients with therapeutic and nephrological profiles were studied. Each sample was aliquoted into three container types: without additives (control, +4 °C), with boric acid (+20 °C), and with chlorhexidine-based preservative (+20 °C). Protein (pyrogallol red method) and creatinine (IDMS-standardized Jaffe method) concentrations were measured on an AU480 analyzer (Beckman Coulter) at 0, 24, 72, 120, and 168 hours. Statistical analysis was performed using MedCalc V20.218 (paired t-test, Pearson correlation, relative bias calculation). Results. In preservative containers, bias did not exceed +4.5% for protein, +2.0% for creatinine, and +4.5% for the protein/creatinine ratio (p>0.05). Although statistically significant differences were observed for protein at 72 h (p=0.038), the magnitude of bias (+4.5%) remained within the clinically acceptable range. In boric acid containers, protein decreased to –3.6% (p=0.049 at 168 h) and creatinine to –6.9% (p0.05). Correlation with the control was r>0.9988. No statistically significant differences were found across all ranges of initial proteinuria (from normal to ≥3.0 g/L). Conclusion. Acti-Fine containers with chlorhexidine-based preservative ensure stability of all studied parameters at +20 °C for 7 days. Boric acid containers are suitable for clinical use but require consideration of systematic creatinine decrease during long-term storage. The protein/creatinine ratio remains highly stable in both container types.
- 26 November 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (3)
Determination of glycated hemoglobin: quality control and comparability of results
Relevance. Currently, there are several analytical methods for measuring glycated hemoglobin levels (chromatographic, electrophoretic, and immunochemical methods). The National Glycohemoglobin Standardization Program (NGSP) recognizes high-performance liquid chromatography (HPLC) with cation-exchange sorption as the reference method. The International Federation of Clinical Chemists (IFCC) has developed a reference procedure based on HPLC combined with mass spectrometry or capillary electrophoresis. Objective. To assess the comparability of HbA1c research results using various methods and quality control in clinical diagnostic laboratories in the Russian Federation. Material and methods. Analysis of recent publications, the results of inter-laboratory comparisons under the “Glycated Hemoglobin” program, provided by the Center for External Quality Control of Clinical Laboratory Research, which is accredited in the Russian Accreditation System with a competence assessment according to GOST ISO/IEC 17043, and data on diabetes mellitus tests in the Saratov Region for 2025. Results and conclusions. The analysis demonstrated a clear trend towards standardization of HbA1c testing in laboratories across the Russian Federation: between 2023 and 2025, the HPLC method became dominant, reaching a share of 40.17%, which was accompanied by a reduction in the number of unsatisfactory results in the MCI “FSVOK” system to 6.1%. The implementation of the primary healthcare modernization program in the Saratov Region, which began in 2022, has made it possible to significantly increase the number of HbA1c analyzers (from 22 to 77), triple the number of tests, and create the foundation for effective monitoring of patients with diabetes within the framework of the federal project “Combating Diabetes”.
- 26 November 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (3)
Determination of glycated hemoglobin: quality control and comparability of results
Relevance. Currently, there are several analytical methods for measuring glycated hemoglobin levels (chromatographic, electrophoretic, and immunochemical methods). The National Glycohemoglobin Standardization Program (NGSP) recognizes high-performance liquid chromatography (HPLC) with cation-exchange sorption as the reference method. The International Federation of Clinical Chemists (IFCC) has developed a reference procedure based on HPLC combined with mass spectrometry or capillary electrophoresis. Objective. To assess the comparability of HbA1c research results using various methods and quality control in clinical diagnostic laboratories in the Russian Federation. Material and methods. Analysis of recent publications, the results of inter-laboratory comparisons under the “Glycated Hemoglobin” program, provided by the Center for External Quality Control of Clinical Laboratory Research, which is accredited in the Russian Accreditation System with a competence assessment according to GOST ISO/IEC 17043, and data on diabetes mellitus tests in the Saratov Region for 2025. Results and conclusions. The analysis demonstrated a clear trend towards standardization of HbA1c testing in laboratories across the Russian Federation: between 2023 and 2025, the HPLC method became dominant, reaching a share of 40.17%, which was accompanied by a reduction in the number of unsatisfactory results in the MCI “FSVOK” system to 6.1%. The implementation of the primary healthcare modernization program in the Saratov Region, which began in 2022, has made it possible to significantly increase the number of HbA1c analyzers (from 22 to 77), triple the number of tests, and create the foundation for effective monitoring of patients with diabetes within the framework of the federal project “Combating Diabetes”.
- 29 June 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (2)
On the issue of professional development of specialists performing immunogenetic studies
Background. A key component of the quality system for immunogenetic research is the level of training of doctors and biologists of tissue typing laboratories (HLA laboratories). Insufficient time is devoted to immunogenetic research within residency programs in the specialty of Clinical Laboratory Diagnostics, and young specialists performing these studies have certain difficulties. Therefore, there is a need to develop advanced training programs for doctors and biologists in HLA laboratories. The aim of this study is to substantiate the need to develop advanced training programs in «Immunogenetic Research» for doctors and biologists in HLA laboratories. Materials and methods. Current domestic and international documents regulating the performance of immunogenetic research, as well as scientific publications devoted to the results of immunogenetic research, were analyzed. Results. This study highlights the main areas of medicine in which immunogenetics plays a significant or key role. This study presents an analysis of documents regulating immunogenetic research in the Russian Federation and in the world, as well as research devoted to studying the relationship between immunogenetic factors and the results of cell and organ transplants. The need for a broader range of studies and the use of current technologies in HLA laboratories in our country is substantiated. A high level of competence of HLA laboratory specialists must be ensured through continuous professional development is essential for achieving these goals. There are the objectives of the theoretical and practical sections of advanced training programs for doctors and biologists in HLA laboratories. The programs are actual for training specialists competent in immunological tissue typing, the selection of histocompatible donor-recipient pairs, and other relevant areas of immunogenetics. Conclusion. The study substantiates the need to develop advanced training programs in «Immunogenetic Research» for doctors and biologists in HLA typing laboratories performing research for transplant centers, the Federal Registry of Bone Marrow Donors, and other medical institutions.
- 29 June 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (2)
On the issue of professional development of specialists performing immunogenetic studies
Background. A key component of the quality system for immunogenetic research is the level of training of doctors and biologists of tissue typing laboratories (HLA laboratories). Insufficient time is devoted to immunogenetic research within residency programs in the specialty of Clinical Laboratory Diagnostics, and young specialists performing these studies have certain difficulties. Therefore, there is a need to develop advanced training programs for doctors and biologists in HLA laboratories. The aim of this study is to substantiate the need to develop advanced training programs in «Immunogenetic Research» for doctors and biologists in HLA laboratories. Materials and methods. Current domestic and international documents regulating the performance of immunogenetic research, as well as scientific publications devoted to the results of immunogenetic research, were analyzed. Results. This study highlights the main areas of medicine in which immunogenetics plays a significant or key role. This study presents an analysis of documents regulating immunogenetic research in the Russian Federation and in the world, as well as research devoted to studying the relationship between immunogenetic factors and the results of cell and organ transplants. The need for a broader range of studies and the use of current technologies in HLA laboratories in our country is substantiated. A high level of competence of HLA laboratory specialists must be ensured through continuous professional development is essential for achieving these goals. There are the objectives of the theoretical and practical sections of advanced training programs for doctors and biologists in HLA laboratories. The programs are actual for training specialists competent in immunological tissue typing, the selection of histocompatible donor-recipient pairs, and other relevant areas of immunogenetics. Conclusion. The study substantiates the need to develop advanced training programs in «Immunogenetic Research» for doctors and biologists in HLA typing laboratories performing research for transplant centers, the Federal Registry of Bone Marrow Donors, and other medical institutions.
- 29 June 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (2)
Development and testing for assessing T-cell immune response in influenza vaccination
Introduction. The assessment of influenza vaccine-induced immunity primarily focuses on the humoral link, whereas the contribution of cellular immunity, which confers cross-protection and long-term memory, is frequently neglected due to a lack of standardized commercial assays. Aim. Optimization and testing of methods for evaluating antigen-specific T-cell responses to influenza A(H1N1), A(H3N2), and B viruses using ELISPOT and ELISA. Materials and methods. The study was performed in two phases: in the first phase (n=20 donors) the optimal antigen concentration was identified (range 200—1 µg/mL). In the second phase, immune response kinetics were analyzed in 100 volunteers before and after vaccination (on days 7 and 28) via ELISPOT (IFNγ-producing cell count) and ELISA (IFNγ and IL-2 quantification). Non-parametric tests were used for statistical analysis. Results. An antigen concentration of 10 µg/mL was established as optimal for all tested influenza strains, yielding a specific signal without background activation. Analysis of volunteer samples showed a statistically significant rise in all measured cellular immunity parameters by day 28 post-vaccination compared to the baseline (p<0.001). Peak cytokine secretion (IL-2 and IFNγ) occurred on day 7, with a minor decline by day 28. Conclusions. We have developed and validated robust methods for assessing influenza-specific T-cell immunity, allowing to track post-vaccination immune dynamics. The results confirm the induction of a specific cellular response and highlight the need for its monitoring in comprehensive vaccine immunogenicity evaluations.
- 29 June 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (2)
Development and testing for assessing T-cell immune response in influenza vaccination
Introduction. The assessment of influenza vaccine-induced immunity primarily focuses on the humoral link, whereas the contribution of cellular immunity, which confers cross-protection and long-term memory, is frequently neglected due to a lack of standardized commercial assays. Aim. Optimization and testing of methods for evaluating antigen-specific T-cell responses to influenza A(H1N1), A(H3N2), and B viruses using ELISPOT and ELISA. Materials and methods. The study was performed in two phases: in the first phase (n=20 donors) the optimal antigen concentration was identified (range 200—1 µg/mL). In the second phase, immune response kinetics were analyzed in 100 volunteers before and after vaccination (on days 7 and 28) via ELISPOT (IFNγ-producing cell count) and ELISA (IFNγ and IL-2 quantification). Non-parametric tests were used for statistical analysis. Results. An antigen concentration of 10 µg/mL was established as optimal for all tested influenza strains, yielding a specific signal without background activation. Analysis of volunteer samples showed a statistically significant rise in all measured cellular immunity parameters by day 28 post-vaccination compared to the baseline (p<0.001). Peak cytokine secretion (IL-2 and IFNγ) occurred on day 7, with a minor decline by day 28. Conclusions. We have developed and validated robust methods for assessing influenza-specific T-cell immunity, allowing to track post-vaccination immune dynamics. The results confirm the induction of a specific cellular response and highlight the need for its monitoring in comprehensive vaccine immunogenicity evaluations.
- 29 June 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (2)
Blood biomarkers in neurodegenerative diseases: pre-analytical, analytical, and post-analytical challenges
Recent advances in blood-based biomarkers for neurodegenerative diseases present promising opportunities for earlier diagnosis and more effective disease monitoring. However, challenges in standardizing sample collection, processing protocols, and data reporting continue to hinder reproducibility, limit cross-study comparability, and delay clinical adoption. As efforts toward harmonization progress (supported by technological innovation and integration into multimodal diagnostic strategies), blood biomarkers are expected to transition from research settings to routine clinical use, bringing precision medicine closer to individuals affected by these disorders.
- 29 June 2026
- Published by Media Sphere Publishing Group in Laboratory Service
- Vol. 15 (2)
Blood biomarkers in neurodegenerative diseases: pre-analytical, analytical, and post-analytical challenges
Recent advances in blood-based biomarkers for neurodegenerative diseases present promising opportunities for earlier diagnosis and more effective disease monitoring. However, challenges in standardizing sample collection, processing protocols, and data reporting continue to hinder reproducibility, limit cross-study comparability, and delay clinical adoption. As efforts toward harmonization progress (supported by technological innovation and integration into multimodal diagnostic strategies), blood biomarkers are expected to transition from research settings to routine clinical use, bringing precision medicine closer to individuals affected by these disorders.