Infinite Biomedical Technologies (United States)
Type
CompanyLocations
Baltimore, United StatesLatest Publications
- Open Access
- 27 June 2026
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
Residual muscle activity associated with phantom limb movements after transhumeral amputation without surgical reinnervation: a preliminary ultrasound study
Transhumeral amputations often result in significant functional limitations. Multiarticulated myoelectric prostheses for individuals with transhumeral amputations are often unreliable because of limitations in signal quality and challenges with accurately detecting motion intent from the available musculature in the residual limb, leading to high prosthesis rejection rates. Surgical approaches like targeted muscle reinnervation have been proposed to mitigate these challenges by biologically amplifying motor signals but are not suitable for all individuals. There is intriguing evidence that distinct muscle activation patterns associated with voluntary mobilization of the phantom limb may be produced in the residual limb after transhumeral amputation even without surgical intervention. However, this phenomenon has not been sufficiently investigated. This study explores the potential of ultrasound imaging to visualize muscle activity associated with phantom hand movements in an individual with transhumeral amputation who has not undergone targeted muscle reinnervation. We demonstrate that ultrasound imaging can capture these patterns, with each tested phantom movement corresponding to unique residual limb muscle activity. The activation patterns for each motion showed greater consistency across repetitions (correlation range: 0.41-0.86) compared to their average similarity with other motions (correlation range 0.06-0.32). These findings provide preliminary imaging evidence suggesting functional innervation of the residual upper arm muscles with digit-level specificity after transhumeral amputation. We recommend further research into modalities that can sense phantom limb mobilization to improve prosthesis control after transhumeral amputation.
- 27 June 2026
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
Open AccessResidual muscle activity associated with phantom limb movements after transhumeral amputation without surgical reinnervation: a preliminary ultrasound study
Transhumeral amputations often result in significant functional limitations. Multiarticulated myoelectric prostheses for individuals with transhumeral amputations are often unreliable because of limitations in signal quality and challenges with accurately detecting motion intent from the available musculature in the residual limb, leading to high prosthesis rejection rates. Surgical approaches like targeted muscle reinnervation have been proposed to mitigate these challenges by biologically amplifying motor signals but are not suitable for all individuals. There is intriguing evidence that distinct muscle activation patterns associated with voluntary mobilization of the phantom limb may be produced in the residual limb after transhumeral amputation even without surgical intervention. However, this phenomenon has not been sufficiently investigated. This study explores the potential of ultrasound imaging to visualize muscle activity associated with phantom hand movements in an individual with transhumeral amputation who has not undergone targeted muscle reinnervation. We demonstrate that ultrasound imaging can capture these patterns, with each tested phantom movement corresponding to unique residual limb muscle activity. The activation patterns for each motion showed greater consistency across repetitions (correlation range: 0.41-0.86) compared to their average similarity with other motions (correlation range 0.06-0.32). These findings provide preliminary imaging evidence suggesting functional innervation of the residual upper arm muscles with digit-level specificity after transhumeral amputation. We recommend further research into modalities that can sense phantom limb mobilization to improve prosthesis control after transhumeral amputation.
- Open Access
- 2 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 1010-1020
Design and Evaluation of User-Centered Extended Reality Myoelectric Prosthesis Training Tool
In recent years, extended reality-based myoelectric training has emerged as a promising approach to prepare users for advanced prosthesis control. This study (1) identified User Needs for an ideal training tool through qualitative interviews with occupational therapists, (2) developed the Myoelectric Training in Extended Reality (MyoTrainXR) system, and (3) evaluated its usability using an advanced postural control strategy. Six individuals with intact limbs and two with trans-radial upper limb loss underwent four 45-minute training sessions with the Block Builder module. The Pasta Box Task was used during training and evaluation, and the Cup Transfer Task was used only during evaluation. In the Pasta Box Task, participants with intact limbs maintained a 100% completion rate, while their success rate increased from 86.1±5.8% to 98.5±3.7%. Participants with upper limb loss began with completion rates between 0% and 40%, improving to 100%, with success rates between 90.9% and 100% by the final evaluation. Iteration completion times showed significant reduction across all participants (p-value < 0.05, linear mixed-effects model), with the median decreasing from 19.4 to 15.8 seconds. The Cup Transfer Task showed a similar trend of significant improvement, demonstrating that the acquired skills generalized to an untrained task. The system also demonstrated excellent usability, with an average System Usability Scale score of 81.9±10.0. These findings indicate that our user-centered extended reality training tool holds promise for enhancing myoelectric control proficiency.
- 2 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 1010-1020
Open AccessDesign and Evaluation of User-Centered Extended Reality Myoelectric Prosthesis Training Tool
In recent years, extended reality-based myoelectric training has emerged as a promising approach to prepare users for advanced prosthesis control. This study (1) identified User Needs for an ideal training tool through qualitative interviews with occupational therapists, (2) developed the Myoelectric Training in Extended Reality (MyoTrainXR) system, and (3) evaluated its usability using an advanced postural control strategy. Six individuals with intact limbs and two with trans-radial upper limb loss underwent four 45-minute training sessions with the Block Builder module. The Pasta Box Task was used during training and evaluation, and the Cup Transfer Task was used only during evaluation. In the Pasta Box Task, participants with intact limbs maintained a 100% completion rate, while their success rate increased from 86.1±5.8% to 98.5±3.7%. Participants with upper limb loss began with completion rates between 0% and 40%, improving to 100%, with success rates between 90.9% and 100% by the final evaluation. Iteration completion times showed significant reduction across all participants (p-value < 0.05, linear mixed-effects model), with the median decreasing from 19.4 to 15.8 seconds. The Cup Transfer Task showed a similar trend of significant improvement, demonstrating that the acquired skills generalized to an untrained task. The system also demonstrated excellent usability, with an average System Usability Scale score of 81.9±10.0. These findings indicate that our user-centered extended reality training tool holds promise for enhancing myoelectric control proficiency.
- 21 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (2) , 843
Corrections to “Functionally Adaptive Myosite Selection Using High-Density sEMG for Upper Limb Myoelectric Prostheses”
Objective: Contributing author was missing from the above-named paper.
- 21 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (2) , 843
Corrections to “Functionally Adaptive Myosite Selection Using High-Density sEMG for Upper Limb Myoelectric Prostheses”
Objective: Contributing author was missing from the above-named paper.
- 25 October 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 8 (83) , eadk9421
Touching reality: Bridging the user-researcher divide in upper-limb prosthetics
Realistically improving upper-limb prostheses is only possible if we listen to users’ actual technological needs.
- 25 October 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 8 (83) , eadk9421
Touching reality: Bridging the user-researcher divide in upper-limb prosthetics
Realistically improving upper-limb prostheses is only possible if we listen to users’ actual technological needs.
- Open Access
Motion prediction using electromyography and sonomyography for an individual with transhumeral limb loss
Controlling multi-articulated prosthetic hands with surface electromyography can be challenging for users. Sonomyography, or ultrasound-based sensing of muscle deformation, avoids some of the problems of electromyography and enables classification of multiple motion patterns in individuals with upper limb loss. Because sonomyography has been previously studied only in individuals with transradial limb loss, the purpose of this study was to assess the feasibility of an individual with transhumeral limb loss using this modality for motion classification. A secondary aim was to compare motion classification performance between electromyography and sonomyography. A single individual with transhumeral limb loss created two datasets containing 11 motions each (individual flexion of each finger, thumb abduction, power grasp, key grasp, tripod, point, pinch, wrist pronation). Electromyography or sonomyography signals associated with every motion were acquired and cross-validation accuracy was computed for each dataset. While all motions were usually predicted successfully with both electromyography and sonomyography, the cross-validation accuracies were typically higher for sonomyography. Although this was an exploratory study, the results suggest that controlling an upper limb prosthesis using sonomyography may be feasible for individuals with transhumeral limb loss.
Open AccessMotion prediction using electromyography and sonomyography for an individual with transhumeral limb loss
Controlling multi-articulated prosthetic hands with surface electromyography can be challenging for users. Sonomyography, or ultrasound-based sensing of muscle deformation, avoids some of the problems of electromyography and enables classification of multiple motion patterns in individuals with upper limb loss. Because sonomyography has been previously studied only in individuals with transradial limb loss, the purpose of this study was to assess the feasibility of an individual with transhumeral limb loss using this modality for motion classification. A secondary aim was to compare motion classification performance between electromyography and sonomyography. A single individual with transhumeral limb loss created two datasets containing 11 motions each (individual flexion of each finger, thumb abduction, power grasp, key grasp, tripod, point, pinch, wrist pronation). Electromyography or sonomyography signals associated with every motion were acquired and cross-validation accuracy was computed for each dataset. While all motions were usually predicted successfully with both electromyography and sonomyography, the cross-validation accuracies were typically higher for sonomyography. Although this was an exploratory study, the results suggest that controlling an upper limb prosthesis using sonomyography may be feasible for individuals with transhumeral limb loss.
- 1 October 2020
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 17 (5) , 056006
Sensory stimulation enhances phantom limb perception and movement decoding
Objective. A major challenge for controlling a prosthetic arm is communication between the device and the user’s phantom limb. We show the ability to enhance phantom limb perception and improve movement decoding through targeted transcutaneous electrical nerve stimulation in individuals with an arm amputation. Approach. Transcutaneous nerve stimulation experiments were performed with four participants with arm amputation to map phantom limb perception. We measured myoelectric signals during phantom hand movements before and after participants received sensory stimulation. Using electroencephalogram (EEG) monitoring, we measured the neural activity in sensorimotor regions during phantom movements and stimulation. In one participant, we also tracked sensory mapping over 2 years and movement decoding performance over 1 year. Main results. Results show improvements in the participants’ ability to perceive and move the phantom hand as a result of sensory stimulation, which leads to improved movement decoding. In the extended study with one participant, we found that sensory mapping remains stable over 2 years. Sensory stimulation improves within-day movement decoding while performance remains stable over 1 year. From the EEG, we observed cortical correlates of sensorimotor integration and increased motor-related neural activity as a result of enhanced phantom limb perception. Significance. This work demonstrates that phantom limb perception influences prosthesis control and can benefit from targeted nerve stimulation. These findings have implications for improving prosthesis usability and function due to a heightened sense of the phantom hand.
- 1 October 2020
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 17 (5) , 056006
Sensory stimulation enhances phantom limb perception and movement decoding
Objective. A major challenge for controlling a prosthetic arm is communication between the device and the user’s phantom limb. We show the ability to enhance phantom limb perception and improve movement decoding through targeted transcutaneous electrical nerve stimulation in individuals with an arm amputation. Approach. Transcutaneous nerve stimulation experiments were performed with four participants with arm amputation to map phantom limb perception. We measured myoelectric signals during phantom hand movements before and after participants received sensory stimulation. Using electroencephalogram (EEG) monitoring, we measured the neural activity in sensorimotor regions during phantom movements and stimulation. In one participant, we also tracked sensory mapping over 2 years and movement decoding performance over 1 year. Main results. Results show improvements in the participants’ ability to perceive and move the phantom hand as a result of sensory stimulation, which leads to improved movement decoding. In the extended study with one participant, we found that sensory mapping remains stable over 2 years. Sensory stimulation improves within-day movement decoding while performance remains stable over 1 year. From the EEG, we observed cortical correlates of sensorimotor integration and increased motor-related neural activity as a result of enhanced phantom limb perception. Significance. This work demonstrates that phantom limb perception influences prosthesis control and can benefit from targeted nerve stimulation. These findings have implications for improving prosthesis usability and function due to a heightened sense of the phantom hand.
- 20 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics & Automation Magazine
- Vol. 27 (1) , 77-86
A Myoelectric Postural Control Algorithm for Persons With Transradial Amputations: A Consideration of Clinical Readiness
The bottleneck in upper limb prosthetic design is the myoelectric control algorithm. We studied the clinical readiness of the myoelectric postural control algorithm in a laboratory setting with two transradial amputees utilizing a commercially available prosthetic limb system. The postural control algorithm was integrated into prosthetic limb systems using standard-of-care components. A comparison between a commercial state-of-the-art system (the i-limb revolution statebased myoelectric controller) and the postural controller was performed with two transradial amputees deploying a selfcontained prosthesis system. The performance achieved using the i-limb revolution state-based controller versus the postural controller was mixed, based on the Southampton Hand Assessment Procedure (SHAP). The SHAP scores indicate that the postural controller with i-limb revolution provided, on average, 66% of hand function compared to that of an intact limb. Future work will study the advantages of the postural control algorithm in everyday use.
- 20 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics & Automation Magazine
- Vol. 27 (1) , 77-86
A Myoelectric Postural Control Algorithm for Persons With Transradial Amputations: A Consideration of Clinical Readiness
The bottleneck in upper limb prosthetic design is the myoelectric control algorithm. We studied the clinical readiness of the myoelectric postural control algorithm in a laboratory setting with two transradial amputees utilizing a commercially available prosthetic limb system. The postural control algorithm was integrated into prosthetic limb systems using standard-of-care components. A comparison between a commercial state-of-the-art system (the i-limb revolution statebased myoelectric controller) and the postural controller was performed with two transradial amputees deploying a selfcontained prosthesis system. The performance achieved using the i-limb revolution state-based controller versus the postural controller was mixed, based on the Southampton Hand Assessment Procedure (SHAP). The SHAP scores indicate that the postural controller with i-limb revolution provided, on average, 66% of hand function compared to that of an intact limb. Future work will study the advantages of the postural control algorithm in everyday use.
- Open Access
- 1 July 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-15
Proprioceptive Sonomyographic Control: A novel method for intuitive and proportional control of multiple degrees-of-freedom for individuals with upper extremity limb loss
Technological advances in multi-articulated prosthetic hands have outpaced the development of methods to intuitively control these devices. In fact, prosthetic users often cite "difficulty of use" as a key contributing factor for abandoning their prostheses. To overcome the limitations of the currently pervasive myoelectric control strategies, namely unintuitive proportional control of multiple degrees-of-freedom, we propose a novel approach: proprioceptive sonomyographiccontrol. Unlike myoelectric control strategies which measure electrical activation of muscles and use the extracted signals to determine the velocity of an end-effector; our sonomyography-based strategy measures mechanical muscle deformation directly with ultrasound and uses the extracted signals to proportionally control the position of an end-effector. Therefore, our sonomyography-based control is congruent with a prosthetic user’s innate proprioception of muscle deformation in the residual limb. In this work, we evaluated proprioceptive sonomyographic control with 5 prosthetic users and 5 able-bodied participants in a virtual target achievement and holding task for 5 different hand motions. We observed that with limited training, the performance of prosthetic users was comparable to that of able-bodied participants and thus conclude that proprioceptive sonomyographic control is a robust and intuitive prosthetic control strategy.
- 1 July 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-15
Open AccessProprioceptive Sonomyographic Control: A novel method for intuitive and proportional control of multiple degrees-of-freedom for individuals with upper extremity limb loss
Technological advances in multi-articulated prosthetic hands have outpaced the development of methods to intuitively control these devices. In fact, prosthetic users often cite "difficulty of use" as a key contributing factor for abandoning their prostheses. To overcome the limitations of the currently pervasive myoelectric control strategies, namely unintuitive proportional control of multiple degrees-of-freedom, we propose a novel approach: proprioceptive sonomyographiccontrol. Unlike myoelectric control strategies which measure electrical activation of muscles and use the extracted signals to determine the velocity of an end-effector; our sonomyography-based strategy measures mechanical muscle deformation directly with ultrasound and uses the extracted signals to proportionally control the position of an end-effector. Therefore, our sonomyography-based control is congruent with a prosthetic user’s innate proprioception of muscle deformation in the residual limb. In this work, we evaluated proprioceptive sonomyographic control with 5 prosthetic users and 5 able-bodied participants in a virtual target achievement and holding task for 5 different hand motions. We observed that with limited training, the performance of prosthetic users was comparable to that of able-bodied participants and thus conclude that proprioceptive sonomyographic control is a robust and intuitive prosthetic control strategy.
- Open Access
Augmented Reality Prosthesis Training Setup for Motor Skill Enhancement
Adjusting to amputation can often time be difficult for the body. Post-surgery, amputees have to wait for up to several months before receiving a properly fitted prosthesis. In recent years, there has been a trend toward quantitative outcome measures. In this paper, we developed the augmented reality (AR) version of one such measure, the Prosthetic Hand Assessment Measure (PHAM). The AR version of the PHAM - HoloPHAM, offers amputees the advantage to train with pattern recognition, at their own time and convenience, pre- and post-prosthesis fitting. We provide a rigorous analysis of our system, focusing on its ability to simulate reach, grasp, and touch in AR. Similarity of motion joint dynamics for reach in physical and AR space were compared, with experiments conducted to illustrate how depth in AR is perceived. To show the effectiveness and validity of our system for prosthesis training, we conducted a 10-day study with able-bodied subjects (N = 3) to see the effect that training on the HoloPHAM had on other established functional outcome measures. A washout phase of 5 days was incorporated to observe the effect without training. Comparisons were made with standardized outcome metrics, along with the progression of kinematic variability over time. Statistically significant (p<0.05) improvements were observed between pre- and post-training stages. Our results show that AR can be an effective tool for prosthesis training with pattern recognition systems, fostering motor learning for reaching movement tasks, and paving the possibility of replacing physical training.
Open AccessAugmented Reality Prosthesis Training Setup for Motor Skill Enhancement
Adjusting to amputation can often time be difficult for the body. Post-surgery, amputees have to wait for up to several months before receiving a properly fitted prosthesis. In recent years, there has been a trend toward quantitative outcome measures. In this paper, we developed the augmented reality (AR) version of one such measure, the Prosthetic Hand Assessment Measure (PHAM). The AR version of the PHAM - HoloPHAM, offers amputees the advantage to train with pattern recognition, at their own time and convenience, pre- and post-prosthesis fitting. We provide a rigorous analysis of our system, focusing on its ability to simulate reach, grasp, and touch in AR. Similarity of motion joint dynamics for reach in physical and AR space were compared, with experiments conducted to illustrate how depth in AR is perceived. To show the effectiveness and validity of our system for prosthesis training, we conducted a 10-day study with able-bodied subjects (N = 3) to see the effect that training on the HoloPHAM had on other established functional outcome measures. A washout phase of 5 days was incorporated to observe the effect without training. Comparisons were made with standardized outcome metrics, along with the progression of kinematic variability over time. Statistically significant (p<0.05) improvements were observed between pre- and post-training stages. Our results show that AR can be an effective tool for prosthesis training with pattern recognition systems, fostering motor learning for reaching movement tasks, and paving the possibility of replacing physical training.
- 1 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1046-1049
Stable Electromyographic Sequence Prediction During Movement Transitions using Temporal Convolutional Networks
Transient muscle movements influence the temporal structure of myoelectric signal patterns, often leading to unstable prediction behavior from movement-pattern classification methods. We show that temporal convolutional network sequential models leverage the myoelectric signal's history to discover contextual temporal features that aid in correctly predicting movement intentions, especially during interclass transitions. We demonstrate myoelectric classification using temporal convolutional networks to effect 3 simultaneous hand and wrist degrees-of-freedom in an experiment involving nine human-subjects. Temporal convolutional networks yield significant (p<;0.001) performance improvements over other state-of-the-art methods in terms of both classification accuracy and stability.
- 1 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1046-1049
Stable Electromyographic Sequence Prediction During Movement Transitions using Temporal Convolutional Networks
Transient muscle movements influence the temporal structure of myoelectric signal patterns, often leading to unstable prediction behavior from movement-pattern classification methods. We show that temporal convolutional network sequential models leverage the myoelectric signal's history to discover contextual temporal features that aid in correctly predicting movement intentions, especially during interclass transitions. We demonstrate myoelectric classification using temporal convolutional networks to effect 3 simultaneous hand and wrist degrees-of-freedom in an experiment involving nine human-subjects. Temporal convolutional networks yield significant (p<;0.001) performance improvements over other state-of-the-art methods in terms of both classification accuracy and stability.