KMS Fusion (United States)
Type
CompanyLocations
Ann Arbor, United StatesLatest Publications
- 1 January 1994
- Published by Elsevier in Fusion Engineering and Design
- Vol. 23 (4) , 251-297
Critical technical issues and evaluation and comparison studies for inertial fusion energy reactors
- 1 January 1994
- Published by Elsevier in Fusion Engineering and Design
- Vol. 23 (4) , 251-297
Critical technical issues and evaluation and comparison studies for inertial fusion energy reactors
- 1 December 1993
- Published by AIP Publishing in Physics of Fluids B: Plasma Physics
- Vol. 5 (12) , 4419-4431
Characterization of laser-produced plasma density profiles using grid image refractometry
- 1 December 1993
- Published by AIP Publishing in Physics of Fluids B: Plasma Physics
- Vol. 5 (12) , 4419-4431
Characterization of laser-produced plasma density profiles using grid image refractometry
- 1 April 1992
- Published by AIP Publishing in Physics of Fluids B: Plasma Physics
- Vol. 4 (4) , 979-988
Collision and interpenetration of plasmas created by laser-illuminated disks
Supersonic, counterstreaming plasmas were produced by ablating plasma from the inside surfaces of two parallel disks made of aluminum and magnesium, respectively, with a 0.53 μm laser at an intensity of 1014 W/cm2 for 1.3 nsec. Diagnostics included holographic interferometry, a time‐integrated x‐ray pinhole camera and a gated x‐ray crystal spectrograph with imaging slits. The plasmas interpenetrate for the first half of the laser pulse but stagnate once the electron density exceeds 5×1020 cm−3. Spectroscopic measurements suggest a coronal electron temperature of ∼800 eV and an ion temperature of ∼15 keV in the stagnated plasma. The observations are in good agreement with a two ion fluid model of interpenetrating plasmas in which the dominant slowing down process is ion–ion collisions.
- 1 April 1992
- Published by AIP Publishing in Physics of Fluids B: Plasma Physics
- Vol. 4 (4) , 979-988
Collision and interpenetration of plasmas created by laser-illuminated disks
Supersonic, counterstreaming plasmas were produced by ablating plasma from the inside surfaces of two parallel disks made of aluminum and magnesium, respectively, with a 0.53 μm laser at an intensity of 1014 W/cm2 for 1.3 nsec. Diagnostics included holographic interferometry, a time‐integrated x‐ray pinhole camera and a gated x‐ray crystal spectrograph with imaging slits. The plasmas interpenetrate for the first half of the laser pulse but stagnate once the electron density exceeds 5×1020 cm−3. Spectroscopic measurements suggest a coronal electron temperature of ∼800 eV and an ion temperature of ∼15 keV in the stagnated plasma. The observations are in good agreement with a two ion fluid model of interpenetrating plasmas in which the dominant slowing down process is ion–ion collisions.
- 1 January 1992
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 63 (1) , 8-20
Laue transmission x-ray spectrograph for inertial confinement fusion (ICF) diagnostics
- 1 January 1992
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 63 (1) , 8-20
Laue transmission x-ray spectrograph for inertial confinement fusion (ICF) diagnostics
- 1 December 1991
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 62 (12) , 2862-2870
Characterization of two-gated microchannel plate framing cameras
The overall performance of both a single- and a double-microchannel plate framing camera were measured. In the case of the double-plated device, only the front plate was gated. A short-pulse, 20-ps full width half-maximum (FWHM), uv laser was used to create photoelectrons on a time scale rapid compared to the temporal variation of the high-voltage gate pulse (965 V peak amplitude and 270 ps FWHM). Measurements were made of the variation in the light output pulse amplitude (8%–24%), width (85–115 ps), and peak location (±22 ps), the latter corresponding to a temporal jitter. It was found that when a dc bias was applied to the plate (in addition to the high-voltage pulse) the output signal increased as the dc bias to the 13 and 5.2 powers, below and above a bias of 450 V, respectively, and a factor of 20 difference in signal between the single- and double-plate cameras. It was also determined that the rejection ratio drops from 500 to 1300 at a bias value of 450 V to 125–190 at 650 V.
- 1 December 1991
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 62 (12) , 2862-2870
Characterization of two-gated microchannel plate framing cameras
The overall performance of both a single- and a double-microchannel plate framing camera were measured. In the case of the double-plated device, only the front plate was gated. A short-pulse, 20-ps full width half-maximum (FWHM), uv laser was used to create photoelectrons on a time scale rapid compared to the temporal variation of the high-voltage gate pulse (965 V peak amplitude and 270 ps FWHM). Measurements were made of the variation in the light output pulse amplitude (8%–24%), width (85–115 ps), and peak location (±22 ps), the latter corresponding to a temporal jitter. It was found that when a dc bias was applied to the plate (in addition to the high-voltage pulse) the output signal increased as the dc bias to the 13 and 5.2 powers, below and above a bias of 450 V, respectively, and a factor of 20 difference in signal between the single- and double-plate cameras. It was also determined that the rejection ratio drops from 500 to 1300 at a bias value of 450 V to 125–190 at 650 V.
- 1 November 1991
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 62 (11) , 2709-2718
Hard x-ray continuum crystal spectrograph for inertial confinement fusion (ICF) diagnostics
We describe absolutely calibrated instrumentation for measuring hard x-ray continuum produced during laser irradiation of ICF targets. The instrumentation includes a crystal spectrograph and two collimated filtered scintillators. The absolutely calibrated crystal spectrograph achieves high sensitivity to x-ray continuum over the energy range of 5 to 35 keV with continuous energy coverage and a resolving power E/ΔE between 20 and 100. Time integrated spectra are recorded and stored electronically on a shot basis using two dimensional charge coupled device (CCD) camera readout of a proximity focused MCP detector close coupled to the x-ray diffracting crystals. The filtered scintillators provide discrete, time-resolved, high energy channels for recording integrated continuum in the 40–60 and 60–90 keV bands. End-to-end calibration of the crystal spectrograph was performed over the design energy interval. We discuss instrument design, calibration, and alignment and the factors affecting sensitivity and resolving power.
- 1 November 1991
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 62 (11) , 2709-2718
Hard x-ray continuum crystal spectrograph for inertial confinement fusion (ICF) diagnostics
We describe absolutely calibrated instrumentation for measuring hard x-ray continuum produced during laser irradiation of ICF targets. The instrumentation includes a crystal spectrograph and two collimated filtered scintillators. The absolutely calibrated crystal spectrograph achieves high sensitivity to x-ray continuum over the energy range of 5 to 35 keV with continuous energy coverage and a resolving power E/ΔE between 20 and 100. Time integrated spectra are recorded and stored electronically on a shot basis using two dimensional charge coupled device (CCD) camera readout of a proximity focused MCP detector close coupled to the x-ray diffracting crystals. The filtered scintillators provide discrete, time-resolved, high energy channels for recording integrated continuum in the 40–60 and 60–90 keV bands. End-to-end calibration of the crystal spectrograph was performed over the design energy interval. We discuss instrument design, calibration, and alignment and the factors affecting sensitivity and resolving power.
- 1 October 1991
- Published by Wiley in X-Ray Spectrometry
- Vol. 20 (5) , 245-254
Theory and numerical modeling of x‐ray fluorescence from multi‐layer spheres
A mathematical model has been developed for the quantitative x‐ray fluorescence spectrometry of small spherical samples, e.g. targets containing diagnostic materials for inertial confinement fusion experiments. The model corrects for matrix effects in a multi‐layer spherical geometry much as existing programs now do for thin films or bulk samples. Attenuation effects have been found to be greater in a shell geometry than in a comparable thin‐film geometry because multiple passes through the shell are possible and because many paths in or out are nearly tangential to the shell. In both cases the path is longer and attenuation is greater. The model for primary fluorescence from uniform shells has also been extended to approximate the fluorescence from non‐uniform shells. This allows one to predict how experimental results would vary with sample mounting if excess material were oriented toward or away from the x‐ray beam or the detector or away from both. Finally, a simplified model for estimating the magnitude of secondary fluorescence effects is presented.
- 1 October 1991
- Published by Wiley in X-Ray Spectrometry
- Vol. 20 (5) , 245-254
Theory and numerical modeling of x‐ray fluorescence from multi‐layer spheres
A mathematical model has been developed for the quantitative x‐ray fluorescence spectrometry of small spherical samples, e.g. targets containing diagnostic materials for inertial confinement fusion experiments. The model corrects for matrix effects in a multi‐layer spherical geometry much as existing programs now do for thin films or bulk samples. Attenuation effects have been found to be greater in a shell geometry than in a comparable thin‐film geometry because multiple passes through the shell are possible and because many paths in or out are nearly tangential to the shell. In both cases the path is longer and attenuation is greater. The model for primary fluorescence from uniform shells has also been extended to approximate the fluorescence from non‐uniform shells. This allows one to predict how experimental results would vary with sample mounting if excess material were oriented toward or away from the x‐ray beam or the detector or away from both. Finally, a simplified model for estimating the magnitude of secondary fluorescence effects is presented.
- 1 May 1991
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 9 (3) , 824-830
The deposition of oxygen containing plasma polymers for use as permeation barrier coatings
It has been found that common polymers containing oxygen have reduced hydrogen permeability. In this work we have incorporated oxygen into plasmapolymer coatings as hydroxyl (OH) and carbonyl (C=O) side groups by codepositing organic vapors with H2O or H2O2. We can vary the amount of oxygen incorporated up to 25 wt% oxygen. By adjusting the amount of incorporated oxygen and the deposition parameters we can alter the hydrogen permeability of the coatings by more than three orders of magnitude. Choice of the organic precursor used has the largest effect on incorporation of OH groups into glow dischargepolymerization coatings. Organics with multiple triple bonds codeposited with H2O2 produce polymer coatings with the highest oxygen content and the lowest hydrogen permeability. Organics with nitrogen such as acetonitrile codeposited with H2O2 produced plasmapolymer coatings with reasonably low permeability and improved mechanical and chemical resistance. Coated membranes were exposed to radioactive tritium gas for extended periods of time and then analyzed for deterioration by remeasuring hydrogen permeability, infrared absorption, and mechanical stability.
- 1 May 1991
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 9 (3) , 824-830
The deposition of oxygen containing plasma polymers for use as permeation barrier coatings
It has been found that common polymers containing oxygen have reduced hydrogen permeability. In this work we have incorporated oxygen into plasmapolymer coatings as hydroxyl (OH) and carbonyl (C=O) side groups by codepositing organic vapors with H2O or H2O2. We can vary the amount of oxygen incorporated up to 25 wt% oxygen. By adjusting the amount of incorporated oxygen and the deposition parameters we can alter the hydrogen permeability of the coatings by more than three orders of magnitude. Choice of the organic precursor used has the largest effect on incorporation of OH groups into glow dischargepolymerization coatings. Organics with multiple triple bonds codeposited with H2O2 produce polymer coatings with the highest oxygen content and the lowest hydrogen permeability. Organics with nitrogen such as acetonitrile codeposited with H2O2 produced plasmapolymer coatings with reasonably low permeability and improved mechanical and chemical resistance. Coated membranes were exposed to radioactive tritium gas for extended periods of time and then analyzed for deterioration by remeasuring hydrogen permeability, infrared absorption, and mechanical stability.
- 1 May 1991
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 9 (3) , 831-834
Sandwich holography modeling study of solid deuterium–tritium layers
- 1 May 1991
- Published by American Vacuum Society in Journal of Vacuum Science & Technology A
- Vol. 9 (3) , 831-834
Sandwich holography modeling study of solid deuterium–tritium layers
- 1 April 1991
- Published by SPIE-Intl Soc Optical Eng
- Vol. 1383, 84-97
Recognition, tracking, and pose estimation of arbitrarily shaped 3-D objects in cluttered intensity and range imagery
Algorithms for recognition, tracking, and pose estimation of 3-d objects in intensity imagery commonly assume that features are the result of imaging surface landmarks. This assumption is most commonly violated when a feature is detected on an occluding boundary generated by a smoothly curving surface. We have developed a method that can recognize, track, and determine the pose of arbitrarily shaped, partially visible 3-d objects in both intensity and range imagery. We describe the results of tests on real intensity imagery and synthetic range imagery.
- 1 April 1991
- Published by SPIE-Intl Soc Optical Eng
- Vol. 1383, 84-97
Recognition, tracking, and pose estimation of arbitrarily shaped 3-D objects in cluttered intensity and range imagery
Algorithms for recognition, tracking, and pose estimation of 3-d objects in intensity imagery commonly assume that features are the result of imaging surface landmarks. This assumption is most commonly violated when a feature is detected on an occluding boundary generated by a smoothly curving surface. We have developed a method that can recognize, track, and determine the pose of arbitrarily shaped, partially visible 3-d objects in both intensity and range imagery. We describe the results of tests on real intensity imagery and synthetic range imagery.