MetroLaser (United States)
Type
CompanyLocations
Laguna Hills, United StatesLatest Publications
- Open Access
- 1 October 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13128, 15-81
A digital holographic microscope educational kit for educators and students of holography
Digital Holographic Microscopy (DHM) has become a powerful diagnostics tool for the sciences, especially biology. In addition, DHM has great potential for use in education because it is so flexible and affordable to schools and students. For many years, the cost and complexity of producing and using holograms limited their use to a narrow range of industry and science. Digital holography has removed these limitations making holography affordable and available to anyone who has a laptop computer. Affordable digital holocameras entering the market can enable teachers and students to produce and view their own holograms, reconstruct and view three dimensional images, and better understand and use holography in research. This paper describes such a system including exercises and experiments that explain how holograms are made and how they are used to record and analyze dynamic events that take place in three dimensions. MetroLaser’s “Holoscope”, is a lensless, DHM that produces holographic videos of microscopic objects distributed in a relatively large volume. Each frame in the video is a digital hologram that encodes 3D images that can be focused and viewed, plane by plane in detail. The three-dimensional images encoded in the holograms are electronically reconstructed, scanned, and viewed with sharp images coming in and out of focus on a computer monitor as we scan through the volume. By providing micrometer resolution throughout a cubic centimeter volume, the system effectively freezes time at the moment each frame was recorded and enables precisely tracking the 3D movement of microscopic objects in space and time. The ability to view each hologram in real-time, shows directly how interference between an object and reference wave produces interference fringes that become the hologram. Software provided with the system enables the viewer to automatically perform all of the necessary operations from hologram recording to 3D wavefront reconstruction and plane by plane imaging. We also describe more advanced and more expensive DHMs with even higher resolution that are now also available for scientific research.
- 1 October 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13128, 15-81
Open AccessA digital holographic microscope educational kit for educators and students of holography
Digital Holographic Microscopy (DHM) has become a powerful diagnostics tool for the sciences, especially biology. In addition, DHM has great potential for use in education because it is so flexible and affordable to schools and students. For many years, the cost and complexity of producing and using holograms limited their use to a narrow range of industry and science. Digital holography has removed these limitations making holography affordable and available to anyone who has a laptop computer. Affordable digital holocameras entering the market can enable teachers and students to produce and view their own holograms, reconstruct and view three dimensional images, and better understand and use holography in research. This paper describes such a system including exercises and experiments that explain how holograms are made and how they are used to record and analyze dynamic events that take place in three dimensions. MetroLaser’s “Holoscope”, is a lensless, DHM that produces holographic videos of microscopic objects distributed in a relatively large volume. Each frame in the video is a digital hologram that encodes 3D images that can be focused and viewed, plane by plane in detail. The three-dimensional images encoded in the holograms are electronically reconstructed, scanned, and viewed with sharp images coming in and out of focus on a computer monitor as we scan through the volume. By providing micrometer resolution throughout a cubic centimeter volume, the system effectively freezes time at the moment each frame was recorded and enables precisely tracking the 3D movement of microscopic objects in space and time. The ability to view each hologram in real-time, shows directly how interference between an object and reference wave produces interference fringes that become the hologram. Software provided with the system enables the viewer to automatically perform all of the necessary operations from hologram recording to 3D wavefront reconstruction and plane by plane imaging. We also describe more advanced and more expensive DHMs with even higher resolution that are now also available for scientific research.
- 4 October 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12672, 27-186
Simultaneous tomographic multi-component reconstructions using multispectral plenoptic cameras
This paper introduces a methodology for simultaneously conducting multi-component 3D measurements in highspeed turbulent afterburning flames using several spectral plenoptic cameras. Traditionally, plenoptic imaging techniques capture the 3D scene using a single camera, where the camera is modified to include a microlens array that is located between the primary lens and the sensor. Each pixel behind a microlens encodes angular information onto the sensor by sampling a point on the main lens. A multispectral plenoptic camera is a combination of a plenoptic camera with a spectral filter array at the primary lens aperture plane. Thus, spectral information is encoded onto angular information, such that the camera captures spatial, angular, and spectral information of a light-field in a single-snapshot, which enables multiple measurements to be performed using discrete spectral bands from a single camera. Additional cameras provide improved performance by extending the overall range of angular information captured. Experiments were conducted using three spectral plenoptic cameras to capture subsets of the following measurement within a sonic hydrogen flame and subsonic ethylene flame: tomographic particle image velocimetry; dual-wavelength pyrometry of particle-laden flow; and 3D measurement the chemiluminescence of CH*. This work demonstrates the ability to simultaneously capture multiple 3D measurements with views from as few as three multispectral plenoptic cameras, whereas traditional cameras could require an order of magnitude more sensors.
- 4 October 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12672, 27-186
Simultaneous tomographic multi-component reconstructions using multispectral plenoptic cameras
This paper introduces a methodology for simultaneously conducting multi-component 3D measurements in highspeed turbulent afterburning flames using several spectral plenoptic cameras. Traditionally, plenoptic imaging techniques capture the 3D scene using a single camera, where the camera is modified to include a microlens array that is located between the primary lens and the sensor. Each pixel behind a microlens encodes angular information onto the sensor by sampling a point on the main lens. A multispectral plenoptic camera is a combination of a plenoptic camera with a spectral filter array at the primary lens aperture plane. Thus, spectral information is encoded onto angular information, such that the camera captures spatial, angular, and spectral information of a light-field in a single-snapshot, which enables multiple measurements to be performed using discrete spectral bands from a single camera. Additional cameras provide improved performance by extending the overall range of angular information captured. Experiments were conducted using three spectral plenoptic cameras to capture subsets of the following measurement within a sonic hydrogen flame and subsonic ethylene flame: tomographic particle image velocimetry; dual-wavelength pyrometry of particle-laden flow; and 3D measurement the chemiluminescence of CH*. This work demonstrates the ability to simultaneously capture multiple 3D measurements with views from as few as three multispectral plenoptic cameras, whereas traditional cameras could require an order of magnitude more sensors.
- 4 October 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12672, 94-102
Digital holographic microscopy for bacterial species classification and motility characterization
We have previously presented our work in developing and applying a commercial digital holographic microscopy (DHM) system for volumetric, 3D characterization of bacterial motility. The system was applied to simple biological systems, i.e., single bacterial species, to demonstrate its effectiveness. We are now applying DHM to more realistic conditions, including multiple bacterial types, to differentiate the species of interest for investigating their interactions. Our workflow for species classification and motility characterization combines DHM and machine learning. Specifically, our DHM instrument acquires holograms of single bacterial species and mixtures of different species, the software extracts in-focus images of individual bacteria and their trajectories, and deep convolutional neural network models are constructed and trained using the in-focus images and then deployed to the mixture data for classification. The motility and morphology of the predicted species in the mixture is consistent with the measurements from isolates, verifying the effectiveness of the developed workflow. This work showcases the application of DHM to investigate complex biological systems.
- 4 October 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12672, 94-102
Digital holographic microscopy for bacterial species classification and motility characterization
We have previously presented our work in developing and applying a commercial digital holographic microscopy (DHM) system for volumetric, 3D characterization of bacterial motility. The system was applied to simple biological systems, i.e., single bacterial species, to demonstrate its effectiveness. We are now applying DHM to more realistic conditions, including multiple bacterial types, to differentiate the species of interest for investigating their interactions. Our workflow for species classification and motility characterization combines DHM and machine learning. Specifically, our DHM instrument acquires holograms of single bacterial species and mixtures of different species, the software extracts in-focus images of individual bacteria and their trajectories, and deep convolutional neural network models are constructed and trained using the in-focus images and then deployed to the mixture data for classification. The motility and morphology of the predicted species in the mixture is consistent with the measurements from isolates, verifying the effectiveness of the developed workflow. This work showcases the application of DHM to investigate complex biological systems.
- 17 May 2023
- Published by Office of Scientific and Technical Information (OSTI)
Abstract – Cooperative Research and Development Agreement between National Energy Technology Laboratory and MetroLaser, Inc.
The U.S. Department of Energy's Office of Scientific and Technical Information
- 17 May 2023
- Published by Office of Scientific and Technical Information (OSTI)
Abstract – Cooperative Research and Development Agreement between National Energy Technology Laboratory and MetroLaser, Inc.
The U.S. Department of Energy's Office of Scientific and Technical Information
- 18 April 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12487, 196-212
Non-destructive damage detection using laser Doppler vibrometry and machine learning statistical techniques
Due to its ability to manufacture a single, complex part that either (1) could not have been built with traditional manufacturing or (2) would require the assembly of several sub-components, the use of Metal Additive Manufacturing (MAM) has increased over 300% in just the last 5 years1,2. Even with the advancements in the technology of Metal Additive Manufacturing, the final as-built mechanical properties continue to possess variability that make it difficult for designers and engineers to utilize them effectively, especially on mission critical parts. The final material properties of an MAM part are process and operator-dependent and the MAM process is more complex than traditional metal manufacturing techniques. The ability to non-destructively validate the quality of an MAM part is critical as the utilization of metal these parts increases. This paper describes ongoing research that focuses on techniques that can predict if a given part meets customer requirements and is free from hidden defects, flaws, non-visible geometric fluctuations, and variations in mechanical properties that are critical to the design/analysis process and mission certification. The techniques use Laser Doppler Vibrometry to detect the frequency response spectrum for a given part then process that data with non-p-value statistical techniques (Machine Learning) to develop models that can be “trained” to detect a variety of quality issues. Machine Learning models work best when data from many samples with different unacceptable end-states are available and used to train and develop the models. These end-states could be the result of a variety of unacceptable variations in the MAM process, quality of the precursor powdered metal, quality of the millions of micro-welds that make up the MAM build process, size and number of inclusions and micro flaws in the material as well as residual stresses in the part. In this study, our goals were to (1) use a large enough number of parts to ensure the validity of the machine learning model and (2) focus on geometric defects and the effects of residual stresses. For these initial investigations, we utilized Off-The-Shelf parts to increase statistical reliability, improve our ability to train our Machine Learning Model and refine our experimental protocol while keeping costs within the budget for the research. In the second phase of this research, we will use MAM parts.
- 18 April 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12487, 196-212
Non-destructive damage detection using laser Doppler vibrometry and machine learning statistical techniques
Due to its ability to manufacture a single, complex part that either (1) could not have been built with traditional manufacturing or (2) would require the assembly of several sub-components, the use of Metal Additive Manufacturing (MAM) has increased over 300% in just the last 5 years1,2. Even with the advancements in the technology of Metal Additive Manufacturing, the final as-built mechanical properties continue to possess variability that make it difficult for designers and engineers to utilize them effectively, especially on mission critical parts. The final material properties of an MAM part are process and operator-dependent and the MAM process is more complex than traditional metal manufacturing techniques. The ability to non-destructively validate the quality of an MAM part is critical as the utilization of metal these parts increases. This paper describes ongoing research that focuses on techniques that can predict if a given part meets customer requirements and is free from hidden defects, flaws, non-visible geometric fluctuations, and variations in mechanical properties that are critical to the design/analysis process and mission certification. The techniques use Laser Doppler Vibrometry to detect the frequency response spectrum for a given part then process that data with non-p-value statistical techniques (Machine Learning) to develop models that can be “trained” to detect a variety of quality issues. Machine Learning models work best when data from many samples with different unacceptable end-states are available and used to train and develop the models. These end-states could be the result of a variety of unacceptable variations in the MAM process, quality of the precursor powdered metal, quality of the millions of micro-welds that make up the MAM build process, size and number of inclusions and micro flaws in the material as well as residual stresses in the part. In this study, our goals were to (1) use a large enough number of parts to ensure the validity of the machine learning model and (2) focus on geometric defects and the effects of residual stresses. For these initial investigations, we utilized Off-The-Shelf parts to increase statistical reliability, improve our ability to train our Machine Learning Model and refine our experimental protocol while keeping costs within the budget for the research. In the second phase of this research, we will use MAM parts.
- 9 February 2023
- Published by Springer Nature in Experiments in Fluids
- Vol. 64 (2) , 1-18
Investigation of the Richtmyer–Meshkov instability using digital holography in the context of catastrophic aerobreakup
- 9 February 2023
- Published by Springer Nature in Experiments in Fluids
- Vol. 64 (2) , 1-18
Investigation of the Richtmyer–Meshkov instability using digital holography in the context of catastrophic aerobreakup
- 3 October 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12223, 18-140
A new optical diagnostics tools for grading additive manufactured parts
In previous papers, we described a diagnostics tool for additive manufacturing products that is based on the concept that the acoustical/vibrational spectrum of an object can be used as a unique signature that characterizes the material and geometry of a product sufficiently to enable its comparison with a perfect reference to identify anomalies. This enables a user to identify rogue parts, such as defective, counterfeit, suspicious or problem parts such as defective or failing to meet specifications. The instrument produces a signature by measuring, with a laser Doppler vibrometer, the vibration of surface points on the part while it is energized by a swept frequency, piezo-electric exciter. Since its first introduction, additional research and development has enhanced, automated, and moved the instrument to a new level in terms of capability and ease of use. This paper describes the latest enhancements, including improved procedures and automation to enable use by an unsophisticated user with minimum training. The latest version provides automatic signal processing and comparison of acoustical signatures of reference and test objects that provide a quantitative grade for the object in terms of material properties, geometrical anomalies, and defects. This is achieved with specially developed algorithms that employ unique types of correlation of vibrational spectra taken from different objects or spectra produced by a simulation of a perfect object. The instrument can quickly produce an optimized correlation coefficient that serves as a numeric grade for a part for identifying suspicious or problem parts such as counterfeits, defective, or failing to meet specifications. The user can set acceptance criteria and initiate a pass or fail signal that can be used for large quantity inspections. Such an instrument is expected to find widespread applications in the AM industry.
- 3 October 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12223, 18-140
A new optical diagnostics tools for grading additive manufactured parts
In previous papers, we described a diagnostics tool for additive manufacturing products that is based on the concept that the acoustical/vibrational spectrum of an object can be used as a unique signature that characterizes the material and geometry of a product sufficiently to enable its comparison with a perfect reference to identify anomalies. This enables a user to identify rogue parts, such as defective, counterfeit, suspicious or problem parts such as defective or failing to meet specifications. The instrument produces a signature by measuring, with a laser Doppler vibrometer, the vibration of surface points on the part while it is energized by a swept frequency, piezo-electric exciter. Since its first introduction, additional research and development has enhanced, automated, and moved the instrument to a new level in terms of capability and ease of use. This paper describes the latest enhancements, including improved procedures and automation to enable use by an unsophisticated user with minimum training. The latest version provides automatic signal processing and comparison of acoustical signatures of reference and test objects that provide a quantitative grade for the object in terms of material properties, geometrical anomalies, and defects. This is achieved with specially developed algorithms that employ unique types of correlation of vibrational spectra taken from different objects or spectra produced by a simulation of a perfect object. The instrument can quickly produce an optimized correlation coefficient that serves as a numeric grade for a part for identifying suspicious or problem parts such as counterfeits, defective, or failing to meet specifications. The user can set acceptance criteria and initiate a pass or fail signal that can be used for large quantity inspections. Such an instrument is expected to find widespread applications in the AM industry.
- 1 August 2022
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 17 (08) , P08019
100 megahertz-rate ultrahigh-speed digital holography instrument
This work presents the development of an ultrahigh-speed digital holography instrument that can perform volumetric measurements at a rate of up to 100 million frames per second. The system is based on an Ultra 8 camera that uses a single custom-built image intensifier with a segmented photocathode that can gate eight different imaging regions down to 10 ns. An in-line interferometric scheme is used to capture the deformation of a water drop as it is photoablated from irradiation by a 1064 nm wavelength pulsed laser beam. After a digital holographic video is captured, wavefront reconstruction is used to focus on discrete depth planes enabling the user to observe different 3-dimensional features of the drop as the field-of-view is scanned plane-by-plane. The reconstructions are detwinned and corrected for parallax and alignment error before a final image at any given depth is produced. We provide one-to-one comparisons between conventional focused imaging and digital holography to demonstrate the 3-dimensional visualization capabilities of the instrument with particular regard to dynamic events occurring at nanosecond time intervals for future applications to hypersonic flows and other short and ultrashort duration events.
- 1 August 2022
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 17 (08) , P08019
100 megahertz-rate ultrahigh-speed digital holography instrument
This work presents the development of an ultrahigh-speed digital holography instrument that can perform volumetric measurements at a rate of up to 100 million frames per second. The system is based on an Ultra 8 camera that uses a single custom-built image intensifier with a segmented photocathode that can gate eight different imaging regions down to 10 ns. An in-line interferometric scheme is used to capture the deformation of a water drop as it is photoablated from irradiation by a 1064 nm wavelength pulsed laser beam. After a digital holographic video is captured, wavefront reconstruction is used to focus on discrete depth planes enabling the user to observe different 3-dimensional features of the drop as the field-of-view is scanned plane-by-plane. The reconstructions are detwinned and corrected for parallax and alignment error before a final image at any given depth is produced. We provide one-to-one comparisons between conventional focused imaging and digital holography to demonstrate the 3-dimensional visualization capabilities of the instrument with particular regard to dynamic events occurring at nanosecond time intervals for future applications to hypersonic flows and other short and ultrashort duration events.
- 31 March 2022
- Published by Office of Scientific and Technical Information (OSTI)
Abstract – Cooperative Research and Development Agreement between National Energy Technology Laboratory and MetroLaser, Inc.
The U.S. Department of Energy's Office of Scientific and Technical Information
- 31 March 2022
- Published by Office of Scientific and Technical Information (OSTI)
Abstract – Cooperative Research and Development Agreement between National Energy Technology Laboratory and MetroLaser, Inc.
The U.S. Department of Energy's Office of Scientific and Technical Information
- 1 August 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11817, 118170I
Defect detection in additive manufactured products with a new photonics procedure: a case study
We describe a new photonics procedure developed for non-destructive testing of additive manufactured (AM) parts and present a case study for inspection of AM brackets to detect and reject parts containing printing defects. This is an update of a previously presented paper of the work in progress to develop an Authentication Sensing System Using Resonance Evaluation Spectroscopy (ASSURES). The principle of operation is based on the concept that a part’s vibration spectrum (set of resonant frequencies) is uniquely determined by its dimensions, material parameters, and interior flaws. The vibration spectrum of a part can be measured remotely with a laser vibrometer, and the presence of defects or a change in material parameters can be inferred from a change in the part’s vibration spectrum (shifts in the resonant frequencies). The spectrum of a part can be measured and compared in a few seconds to a known “good” part, a “good” reference spectrum, or to other parts in the batch.
- 1 August 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11817, 118170I
Defect detection in additive manufactured products with a new photonics procedure: a case study
We describe a new photonics procedure developed for non-destructive testing of additive manufactured (AM) parts and present a case study for inspection of AM brackets to detect and reject parts containing printing defects. This is an update of a previously presented paper of the work in progress to develop an Authentication Sensing System Using Resonance Evaluation Spectroscopy (ASSURES). The principle of operation is based on the concept that a part’s vibration spectrum (set of resonant frequencies) is uniquely determined by its dimensions, material parameters, and interior flaws. The vibration spectrum of a part can be measured remotely with a laser vibrometer, and the presence of defects or a change in material parameters can be inferred from a change in the part’s vibration spectrum (shifts in the resonant frequencies). The spectrum of a part can be measured and compared in a few seconds to a known “good” part, a “good” reference spectrum, or to other parts in the batch.