Megger (United Kingdom)

Latest Publications
- Open Access
- 2 April 2026
- Published by Institute of Physics, Polish Academy of Sciences in Acta Physica Polonica A
- Vol. 149 (3) , S102
Experimental Investigation of Magnetic Permeability Degradation Due to Welding in 80NI–Fe and 50NI–Fe Magnetic Shielding Alloys
This experimental study investigates welding operation on two magnetic shielding materials (80Ni–Fe and 50Ni–Fe), and the results indicate that, especially at lower excitation amplitude and frequency (50 Hz), the permeability of the welded joints can be significantly lower, i.e., reduced by up to 80% from the original value. At a higher frequency (400 Hz), the apparent degradation is not as severe, mostly because the apparent permeability is significantly lower due to global eddy currents. If welds constitute only a small proportion of the overall volume of the shield, the equivalent permeability is affected proportionally to the reluctance of each part. Recommended annealing is unable to fully recover the initial permeability measured at lower frequencies, but it is beneficial in improving the permeability.
- 2 April 2026
- Published by Institute of Physics, Polish Academy of Sciences in Acta Physica Polonica A
- Vol. 149 (3) , S102
Open AccessExperimental Investigation of Magnetic Permeability Degradation Due to Welding in 80NI–Fe and 50NI–Fe Magnetic Shielding Alloys
This experimental study investigates welding operation on two magnetic shielding materials (80Ni–Fe and 50Ni–Fe), and the results indicate that, especially at lower excitation amplitude and frequency (50 Hz), the permeability of the welded joints can be significantly lower, i.e., reduced by up to 80% from the original value. At a higher frequency (400 Hz), the apparent degradation is not as severe, mostly because the apparent permeability is significantly lower due to global eddy currents. If welds constitute only a small proportion of the overall volume of the shield, the equivalent permeability is affected proportionally to the reluctance of each part. Recommended annealing is unable to fully recover the initial permeability measured at lower frequencies, but it is beneficial in improving the permeability.
- Open Access
A Methodology for Calculating the R-L Parameters of a Nonlinear Hysteretic Inductor Model in the Time Domain
The aim of this paper is to present a methodology for the calculation of the R-L parameters of a model of a nonlinear hysteretic inductor. The methodology is based on the analysis of the instantaneous magnetising power calculated from the hysteresis loop of the inductor and is completely developed in the time domain. The instantaneous magnetising power is firstly separated into the oscillatory and absorbed components. Thereafter, the parameter R is calculated using the absorbed component and the parameter L using the oscillatory component. The methodology is validated through the comparison of the results for parameters R and L obtained with the proposed method and the existing method based on the Poynting theorem. The validation is demonstrated on the specific simulated cases with idealised parameters of a nonlinear circuit. Additionally, the paper presents results for the parameters R and L calculated from the hysteresis loops measured at frequencies from 1 to 300 Hz. Furthermore, the fitting functions representing the variation of these parameters with the rate of change of magnetic flux density, and the corresponding results, are presented in the paper. A discussion of all the results presented and applicability of the methodology proposed, as well as the concluding remarks, are given thereafter.
Open AccessA Methodology for Calculating the R-L Parameters of a Nonlinear Hysteretic Inductor Model in the Time Domain
The aim of this paper is to present a methodology for the calculation of the R-L parameters of a model of a nonlinear hysteretic inductor. The methodology is based on the analysis of the instantaneous magnetising power calculated from the hysteresis loop of the inductor and is completely developed in the time domain. The instantaneous magnetising power is firstly separated into the oscillatory and absorbed components. Thereafter, the parameter R is calculated using the absorbed component and the parameter L using the oscillatory component. The methodology is validated through the comparison of the results for parameters R and L obtained with the proposed method and the existing method based on the Poynting theorem. The validation is demonstrated on the specific simulated cases with idealised parameters of a nonlinear circuit. Additionally, the paper presents results for the parameters R and L calculated from the hysteresis loops measured at frequencies from 1 to 300 Hz. Furthermore, the fitting functions representing the variation of these parameters with the rate of change of magnetic flux density, and the corresponding results, are presented in the paper. A discussion of all the results presented and applicability of the methodology proposed, as well as the concluding remarks, are given thereafter.
- 16 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (13) , 4021-4028
Sensitivity to Off-Axis Vector Components of Typical Wire Wound Flat H-Coil Configurations
Power loss in magnetically soft magnetic materials can be measured by detecting magnetic field strength H and flux density B. H can be detected with the so-called H-coil sensor, which is an induction coil wound on a thin flat non-magnetic former. The accuracy of H measurement directly affects the measurement of power loss. For alternating (uni-directional) magnetisation H is applied mainly along the symmetry axis of the sample under test and the normal component is small due to magnetically closed circuit. So any off-axis H components usually have small amplitude and do not cause significant errors. However, under two-dimensional or rotational magnetisation the H-coils are exposed to strong H in all directions. It is shown in the paper that such off-axis H components can introduce significant amplitude and phase errors, which contribute to the differences in the calculated clockwise and anticlockwise power loss values. Theoretical analysis of order of magnitude of such off-axis sensitivity is given in the paper for three typical configurations of H-coils (with the return wire positioned along one side, diagonally and through the centre). Experimental verification is also presented for the side wire configuration.
- 16 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (13) , 4021-4028
Sensitivity to Off-Axis Vector Components of Typical Wire Wound Flat H-Coil Configurations
Power loss in magnetically soft magnetic materials can be measured by detecting magnetic field strength H and flux density B. H can be detected with the so-called H-coil sensor, which is an induction coil wound on a thin flat non-magnetic former. The accuracy of H measurement directly affects the measurement of power loss. For alternating (uni-directional) magnetisation H is applied mainly along the symmetry axis of the sample under test and the normal component is small due to magnetically closed circuit. So any off-axis H components usually have small amplitude and do not cause significant errors. However, under two-dimensional or rotational magnetisation the H-coils are exposed to strong H in all directions. It is shown in the paper that such off-axis H components can introduce significant amplitude and phase errors, which contribute to the differences in the calculated clockwise and anticlockwise power loss values. Theoretical analysis of order of magnitude of such off-axis sensitivity is given in the paper for three typical configurations of H-coils (with the return wire positioned along one side, diagonally and through the centre). Experimental verification is also presented for the side wire configuration.
- Open Access
- 1 September 2012
- Published by Czestochowa University of Technology in Journal of Applied Mathematics and Computational Mechanics
- Vol. 11 (3) , 81-92
DC magnetic field generator with spatial coils arrangement
Journal of Applied Mathematics and Computational Mechanics, Prace Naukowe Instytutu Matematyki i Informatyki, Politechnika Cz?stochowska, Scientific Research of the Institute of Mathematics and Computer Science, Czestochowa University of Technology
- 1 September 2012
- Published by Czestochowa University of Technology in Journal of Applied Mathematics and Computational Mechanics
- Vol. 11 (3) , 81-92
Open AccessDC magnetic field generator with spatial coils arrangement
Journal of Applied Mathematics and Computational Mechanics, Prace Naukowe Instytutu Matematyki i Informatyki, Politechnika Cz?stochowska, Scientific Research of the Institute of Mathematics and Computer Science, Czestochowa University of Technology