Type
Company
Locations
Pasadena, United States

Latest Publications

  • Population Pharmacokinetics of Orvacabtagene Autoleucel, an Autologous BCMA-Directed Chimeric Antigen Receptor T-cell Product, in Patients with Relapsed/Refractory Multiple Myeloma

    by Hongxiang Hu, Yan Li, Julia Piasecki, Daniela Hosseyni, Zhicheng Yan, Xianghong Liu, Ken Ogasawara, Simon Zhou, Yiming Cheng

    Purpose: Orvacabtagene autoleucel (orva-cel; JCARH125), a chimeric antigen receptor T-cell therapy targeting B-cell maturation antigen, was evaluated in patients with relapsed/refractory multiple myeloma in the EVOLVE phase I/II study (NCT03430011). We applied a modified piecewise model to characterize orva-cel transgene kinetics and assessed the impact of various covariates on its pharmacokinetics (PK). Experimental Design: The population PK analysis included 159 patients from the EVOLVE study. Traditional piecewise models, employing a first-order expansion rate with or without lag time followed by a biexponential contraction phase, were compared with a modified model incorporating a cell number-dependent expansion phase aligned with cellular physiology. Covariates assessed encompassed baseline demographics, dose levels (50–600 × 106 CD3+ chimeric antigen receptor+ T cells), prior/concomitant medications, baseline disease burden, and antitherapeutic antibody status. Results: Traditional piecewise models failed to accurately describe maximum orva-cel transgene level (Cmax) and underestimated the time to Cmax (Tmax). Our modified model incorporating a cell number–dependent expansion rate outperformed traditional models by (i) more accurately capturing the cellular expansion phase and (ii) yielding a Tmax that closely matches observed values. Additionally, dose level, percentage of plasma cells in bone marrow, and treatment-induced antitherapeutic antibody were identified as statistically significant covariates and associated with orva-cel expansion and/or persistence. Conclusions: Orva-cel PK was adequately described by the modified piecewise model incorporating a cell number–dependent expansion phase, which aligns closely with T-cell biology.


  • A Polymer-Based Extended Release System for Stable, Long-term Intracochlear Drug Delivery

    by Erik Pierstorff, Shanshan Chen, Maria Paola Chaparro, John M. Jr. Cortez, Yen-Jung Chen, Su Young Ryu, Sherry M. Tsai, Marc M. Baum, Wan Wan Yang, Federico Kalinec, et al.

    Objective: Investigate a new polymer-based drug coating suitability for safe intracochlear delivery and ability to maintain long-term physiologically active levels of the corticosteroid fluticasone propionate. Study Design: In vitro dissolution study to evaluate release profiles of polymer-coated drug particles and in vivo studies using a guinea pig model to measure perilymph drug concentrations at specific time points after implantation with polymer-coated drug particles and evaluate their effect on hearing function. Methods: Polymer-coated fluticasone propionate (FP) particles were surgically implanted in guinea pigs through the round window membrane into the cochlear scala tympani. In the pilot study, pre- and post-op hearing thresholds were conducted on days 7, 14, and 42. In a second study, post-op hearing thresholds were conducted on days 90, 120, and 180. Perilymph drug concentrations were measured on the same time points. Results: In 15 of 16 animals from day 7 through day 90, drug levels were within the targeted range, with no initial burst release detected. Drug was present in all animals on day 90 and was detected in some animals at 120 and 180 days. Hearing was tested and compared with non-implanted ears. Very good hearing preservation was observed in ears implanted with intracochlear particles when compared with contralateral ears. Conclusions: The polymer-based extended release system is effective in providing long-term, stable drug delivery for at least 90 days with good hearing outcomes. The results of this study support the potential for achieving long-term drug delivery with a single intracochlear administration.


  • Pharmacokinetics and Preliminary Safety of Pod-Intravaginal Rings Delivering the Monoclonal Antibody VRC01-N for HIV Prophylaxis in a Macaque Model

    by Chunxia Zhao, Manjula Gunawardana, Francois Villinger, Marc M. Baum, Mariana Remedios-Chan, Thomas R. Moench, Larry Zeitlin, Kevin J. Whaley, Ognian Bohorov, Thomas J. Smith, et al.

    The broadly neutralizing antibody (bNAb) VRC01, capable of neutralizing 91% of known human immunodeficiency virus type 1 (HIV-1) isolates in vitro , is a promising candidate microbicide for preventing sexual HIV infection when administered topically to the vagina; however, accessibility to antibody-based prophylactic treatment by target populations in sub-Saharan Africa and other underdeveloped regions may be limited by the high cost of conventionally produced antibodies and the limited capacity to manufacture such antibodies. Intravaginal rings of the pod design (pod-IVRs) delivering Nicotiana -manufactured VRC01 (VRC01-N) over a range of release rates have been developed. The pharmacokinetics and preliminary safety of VRC01-N pod-IVRs were evaluated in a rhesus macaque model. The devices sustained VRC01-N release for up to 21 days at controlled rates, with mean steady-state VRC01-N levels in vaginal fluids in the range of 10 2 to 10 3 μg g −1 being correlated with in vitro release rates. No adverse safety indications were observed. These findings indicate that pod-IVRs are promising devices for the delivery of the candidate topical microbicide VRC01-N against HIV-1 infection and merit further preclinical evaluation.


  • Open Access

    An intravaginal ring for real-time evaluation of adherence to therapy

    by John A. Moss, Marc M. Baum, Jeremiah T. Easley, Darren M. Cox, Thomas J. Smith

    Two recent Phase III clinical trials to investigate an intravaginal ring for preventing HIV infection demonstrated that adherence to prescribed device use was a primary driver of efficacy. Surrogate methods for determining adherence in the studies were limited in their inability to monitor temporal patterns of use and allow deconvolution of the effects of adherence and device efficacy on HIV infection rates. To address this issue, we have developed functionality in an intravaginal ring to continuously monitor when the device is being used and maintain a log of adherence that can be accessed by clinicians after it is removed. An electronic module fabricated with common, inexpensive electronic components was encapsulated in a silicone intravaginal ring. The device uses temperature as a surrogate measure of periods of device insertion and removal, and stores a record of the data for subsequent retrieval. The adherence-monitoring intravaginal ring accurately recorded the device status over 33 simulated IN-OUT cycles and more than 1000 measurement cycles in vitro. Following initial in vitro testing in a temperature-controlled chamber, the device was evaluated in vivo in sheep using a predetermined insertion/removal pattern to simulate intravaginal ring use. After insertion into the vaginal cavity of a sheep, the logged data correctly indicated the device status over 29 hours of continuous measurement including three cycles of insertion and removal. The device described here is a promising, low-cost method for real-time adherence assessment in clinical trials involving medicated intravaginal rings or other intravaginal devices.


  • Open Access

    Topical Delivery of Tenofovir Disoproxil Fumarate and Emtricitabine from Pod-Intravaginal Rings Protects Macaques from Multiple SHIV Exposures

    by Priya Srinivasan, John A. Moss, Manjula Gunawardana, Scott A. Churchman, Flora Yang, Chuong T. Dinh, James M. Mitchell, Jining Zhang, Rob Fanter, Christine S. Miller, et al.

    Topical preexposure prophylaxis (PrEP) against HIV has been marginally successful in recent clinical trials with low adherence rates being a primary factor for failure. Controlled, sustained release of antiretroviral (ARV) drugs may help overcome these low adherence rates if the product is protective for extended periods of time. The oral combination of tenofovir disoproxil fumarate (TDF) and emtricitabine (FTC) is currently the only FDA-approved ARV drug for HIV PrEP. A novel pod-intravaginal ring (IVR) delivering TDF and FTC at independently controlled rates was evaluated for efficacy at preventing SHIV162p3 infection in a rigorous, repeat low-dose vaginal exposure model using normally cycling female pigtailed macaques. Six macaques received pod-IVRs containing TDF (65 mg) and FTC (68 mg) every two weeks, and weekly vaginal exposures to 50 TCID50 of SHIV162p3 began one week after the first pod-IVR insertion. All pod-IVR-treated macaques were fully protected throughout the study (P = 0.0002, Log-rank test), whereas all control animals became infected with a median of 4 exposures to infection. The topical, sustained release of TDF and FTC from the pod-IVR maintained protective drug levels in macaques over four months of virus exposures. This novel and versatile delivery system has the capacity to deliver and maintain protective levels of multiple drugs and the protection observed here warrants clinical evaluation of this pod-IVR design.


  • Combination Pod-Intravaginal Ring Delivers Antiretroviral Agents for HIV Prophylaxis: Pharmacokinetic Evaluation in an Ovine Model

    by John A. Moss, Irina Butkyavichene, Scott A. Churchman, Manjula Gunawardana, Rob Fanter, Christine S. Miller, Flora Yang, Jeremiah T. Easley, Mark A. Marzinke, Craig W. Hendrix, et al.

    Preexposure prophylaxis (PrEP) against HIV using oral regimens based on the nucleoside reverse transcriptase inhibitor tenofovir disoproxil fumarate (TDF) has been effective to various degrees in multiple clinical trials, and the CCR5 receptor antagonist maraviroc (MVC) holds potential for complementary efficacy. The effectiveness of HIV PrEP is highly dependent on adherence. Incorporation of the TDF-MVC combination into intravaginal rings (IVRs) for sustained mucosal delivery could increase product adherence and efficacy compared with oral and vaginal gel formulations. A novel pod-IVR technology capable of delivering multiple drugs is described. The pharmacokinetics and preliminary local safety characteristics of a novel pod-IVR delivering a combination of TDF and MVC were evaluated in the ovine model. The device exhibited sustained release at controlled rates over the 28-day study and maintained steady-state drug levels in cervicovaginal fluids (CVFs). Dilution of CVFs during lavage sample collection was measured by ion chromatography using an inert tracer, allowing corrected drug concentrations to be measured for the first time. Median, steady-state drug levels in vaginal tissue homogenate were as follows: for tenofovir (TFV; in vivo hydrolysis product of TDF), 7.3 × 10 2 ng g −1 (interquartile range [IQR], 3.0 × 10 2 , 4.0 × 10 3 ); for TFV diphosphate (TFV-DP; active metabolite of TFV), 1.8 × 10 4 fmol g −1 (IQR, 1.5 × 10 4 , 4.8 × 10 4 ); and for MVC, 8.2 × 10 2 ng g −1 (IQR, 4.7 × 10 2 , 2.0 × 10 3 ). No adverse events were observed. These findings, together with previous pod-IVR studies, have allowed several lead candidates to advance into clinical evaluation.


  • An intravaginal ring for the sustained delivery of tenofovir disoproxil fumarate

    by Marc M. Baum, Irina Butkyavichene, Scott A. Churchman, Gilbert Lopez, Christine S. Miller, Thomas J. Smith, John A. Moss


  • Open Access

    Pharmacokinetics of Long-Acting Tenofovir Alafenamide (GS-7340) Subdermal Implant for HIV Prophylaxis

    by Manjula Gunawardana, Mariana Remedios-Chan, Christine S. Miller, Rob Fanter, Flora Yang, Mark A. Marzinke, Craig W. Hendrix, Martin Beliveau, John A. Moss, Thomas J. Smith, et al.

    Oral or topical daily administration of antiretroviral (ARV) drugs to HIV-1-negative individuals in vulnerable populations is a promising strategy for HIV-1 prevention. Adherence to the dosing regimen has emerged as a critical factor determining efficacy outcomes of clinical trials. Because adherence to therapy is inversely related to the dosing period, sustained release or long-acting ARV formulations hold significant promise for increasing the effectiveness of HIV-1 preexposure prophylaxis (PrEP) by reducing dosing frequency. A novel, subdermal implant delivering the potent prodrug tenofovir alafenamide (TAF) with controlled, sustained, zero-order (linear) release characteristics is described. A candidate device delivering TAF at 0.92 mg day −1 in vitro was evaluated in beagle dogs over 40 days for pharmacokinetics and preliminary safety. No adverse events related to treatment with the test article were noted during the course of the study, and no significant, unusual abnormalities were observed. The implant maintained a low systemic exposure to TAF (median, 0.85 ng ml −1 ; interquartile range [IQR], 0.60 to 1.50 ng ml −1 ) and tenofovir (TFV; median, 15.0 ng ml −1 ; IQR, 8.8 to 23.3 ng ml −1 ), the product of in vivo TAF hydrolysis. High concentrations (median, 512 fmol/10 6 cells over the first 35 days) of the pharmacologically active metabolite, TFV diphosphate, were observed in peripheral blood mononuclear cells at levels over 30 times higher than those associated with HIV-1 PrEP efficacy in humans. Our report on the first sustained-release nucleoside reverse transcriptase inhibitor (NRTI) for systemic delivery demonstrates a successful proof of principle and holds significant promise as a candidate for HIV-1 prophylaxis in vulnerable populations.


  • Open Access

    Pharmacokinetics of Injectable, Long-Acting Nevirapine for HIV Prophylaxis in Breastfeeding Infants

    by John M. Cortez, Rafaela Quintero, John A. Moss, Martin Beliveau, Thomas J. Smith, Marc M. Baum

    Mother-to-child transmission (MTCT) of HIV-1 remains a global health problem. The World Health Organization (WHO) recommendations advise the administration of a once-daily, oral, prophylactic regimen of the nonnucleoside reverse transcriptase inhibitor nevirapine (NVP) from birth until 4 to 6 weeks of age for infants born to HIV-infected mothers in regions without access to safe and nutritionally adequate alternatives to breast milk. A critical factor driving the successful implementation of the WHO guidelines involves sustaining high adherence to the frequent dosing. With these challenges in mind, we have developed the first injectable, sustained-release NVP formulations with the goal of providing, for 6 weeks or longer, preventative plasma drug levels from a single subcutaneous administration at birth. The long-acting NVP consists of large (>50 μm), monodisperse NVP particles coated with biocompatible polymers that control the drug release kinetics. Two lead formulations exhibiting burst-free, sustained-release kinetics for up to 75 days in vitro were developed. Subsequent in vivo studies in rats demonstrated no toxicity related to the formulations. Rat plasma NVP concentrations were above the analytical assay's limit of quantification for up to 28 days. Pharmacokinetic analysis of the rat plasma NVP concentration-time data allowed absorption rate constants to be calculated. These data then were used to simulate infant NVP exposure from a single injected dose (−1 ) for 6 weeks or longer.