Philips (United Kingdom)

Type
CompanyLocations
Farnborough, United KingdomRelationships
Latest Publications
- Open Access
169 Two-dimensional and four-dimensional velocity imaging quantified mitral regurgitation is associated with left ventricular remodelling post mitral valve surgery
Introduction Accurate assessment of degenerative mitral regurgitation (MRegurg) by transthoracic echocardiography (TTE) can be challenging. Phase-contrast cardiovascular magnetic resonance (PCMR) imaging enables reliable quantitation of MRegurg volume, even in the presence of eccentric and multiple jets, highlighting its advantage in the evaluation of degenerative MRegurg. Consequently, several studies demonstrated discordance of MRegurg severity between PCMR and TTE, with PCMR showing superior correlation with outcomes. Assessment of MRegurg volume by Four-dimensional Flow (4DF) CMR has been shown to be feasible and reproducible. This novel 3-dimensional, free-breathing technique facilitates direct assessment of flow across all four valves simultaneously in one, simple acquisition. 4DF CMR can therefore offer numerous clinical advantages in the evaluation of degenerative MRegurg. Purpose To determine whether 4DF CMR quantitation of degenerative MRegurg volume is predictive of post-operative left ventricular (LV) remodelling. Methods This prospective, single centre, observational cohort study recruited 30 patients with degenerative MRegurg undergoing mitral valve surgery (repair/replacement). All patients underwent TTE, PCMR and 4DF CMR pre-surgery and a follow up PCMR at 6 months post-surgery. MRegurg volume was quantified by TTE (PISA method), PCMR (indirect method) and 4DF CMR (mitral inflow-aortic outflow method). Linear regression analysis was used to assess the predictive value of pre-operative MRegurg volume by these modalities with the post-operative change in the LV end-diastolic volume. Results Median age was 69 (63-72) years; male n=21 (70%). The most common aetiology of MR was posterior mitral valve prolapse n=19 (63.3%), with a flail leaflet present in 10 patients (33.3%). Bland-Altman plots demonstrated smaller bias and narrower limits of agreement between MRegurg volume quantified by 4DF CMR and PCMR, than by the other methods (Figure 1). Furthermore, linear regression analysis demonstrated a significant association between the MRegurg volume and the post-operative LV remodelling, when the regurgitant volume was quantified by PCMR (pConclusion This study demonstrates the potential clinical utility of 4DF CMR in the assessment of degenerative mitral regurgitation. Bland-Altman plots Panel (A) presents Bland-Altman plot of relationship between mitral regurgitant volume quantified by 4DF CMR and PCMR, panel (B) by 4DF CMR and TTE-PISA and panel (C) PCMR and TTE-PISA. Green line represents bias, which is much smaller between 4DF CMR and PCMR (-11.61), than between 4DF CMR and TTE-PISA (98.39) and PCMR and TTE-PISA (102.99) 4DF CMR=4D flow cardiovascular magnetic resonance imaging; LLA=lower limit of agreement; PCMR=phase-contrast magnetic resonance imaging; RV=regurgitant volume; TTE-PISA=transthoracic echocardiography-proximal isovelocity surface area method; ULA=upper limit of agreement Linear regression analysis between post-operative change in left ventricular end-diastolic volume and pre-operative mitral regurgitant volume Panel (A) presents MR regurgitant volume quantified by 4DF CMR, panel (B) by PCMR and panel (C) by the TTE-PISA method 4DF CMR=4D flow cardiovascular magnetic resonance imaging; LVEDV=left ventricular end-diastolic volume; MR=mitral regurgitation; PCMR=phase-contrast magnetic resonance imaging; RVOL=regurgitant volume; TTE-PISA=transthoracic echocardiography-proximal isovelocity surface area method Conflict of Interest None
Open Access169 Two-dimensional and four-dimensional velocity imaging quantified mitral regurgitation is associated with left ventricular remodelling post mitral valve surgery
Introduction Accurate assessment of degenerative mitral regurgitation (MRegurg) by transthoracic echocardiography (TTE) can be challenging. Phase-contrast cardiovascular magnetic resonance (PCMR) imaging enables reliable quantitation of MRegurg volume, even in the presence of eccentric and multiple jets, highlighting its advantage in the evaluation of degenerative MRegurg. Consequently, several studies demonstrated discordance of MRegurg severity between PCMR and TTE, with PCMR showing superior correlation with outcomes. Assessment of MRegurg volume by Four-dimensional Flow (4DF) CMR has been shown to be feasible and reproducible. This novel 3-dimensional, free-breathing technique facilitates direct assessment of flow across all four valves simultaneously in one, simple acquisition. 4DF CMR can therefore offer numerous clinical advantages in the evaluation of degenerative MRegurg. Purpose To determine whether 4DF CMR quantitation of degenerative MRegurg volume is predictive of post-operative left ventricular (LV) remodelling. Methods This prospective, single centre, observational cohort study recruited 30 patients with degenerative MRegurg undergoing mitral valve surgery (repair/replacement). All patients underwent TTE, PCMR and 4DF CMR pre-surgery and a follow up PCMR at 6 months post-surgery. MRegurg volume was quantified by TTE (PISA method), PCMR (indirect method) and 4DF CMR (mitral inflow-aortic outflow method). Linear regression analysis was used to assess the predictive value of pre-operative MRegurg volume by these modalities with the post-operative change in the LV end-diastolic volume. Results Median age was 69 (63-72) years; male n=21 (70%). The most common aetiology of MR was posterior mitral valve prolapse n=19 (63.3%), with a flail leaflet present in 10 patients (33.3%). Bland-Altman plots demonstrated smaller bias and narrower limits of agreement between MRegurg volume quantified by 4DF CMR and PCMR, than by the other methods (Figure 1). Furthermore, linear regression analysis demonstrated a significant association between the MRegurg volume and the post-operative LV remodelling, when the regurgitant volume was quantified by PCMR (pConclusion This study demonstrates the potential clinical utility of 4DF CMR in the assessment of degenerative mitral regurgitation. Bland-Altman plots Panel (A) presents Bland-Altman plot of relationship between mitral regurgitant volume quantified by 4DF CMR and PCMR, panel (B) by 4DF CMR and TTE-PISA and panel (C) PCMR and TTE-PISA. Green line represents bias, which is much smaller between 4DF CMR and PCMR (-11.61), than between 4DF CMR and TTE-PISA (98.39) and PCMR and TTE-PISA (102.99) 4DF CMR=4D flow cardiovascular magnetic resonance imaging; LLA=lower limit of agreement; PCMR=phase-contrast magnetic resonance imaging; RV=regurgitant volume; TTE-PISA=transthoracic echocardiography-proximal isovelocity surface area method; ULA=upper limit of agreement Linear regression analysis between post-operative change in left ventricular end-diastolic volume and pre-operative mitral regurgitant volume Panel (A) presents MR regurgitant volume quantified by 4DF CMR, panel (B) by PCMR and panel (C) by the TTE-PISA method 4DF CMR=4D flow cardiovascular magnetic resonance imaging; LVEDV=left ventricular end-diastolic volume; MR=mitral regurgitation; PCMR=phase-contrast magnetic resonance imaging; RVOL=regurgitant volume; TTE-PISA=transthoracic echocardiography-proximal isovelocity surface area method Conflict of Interest None
- 12 May 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 82 (3) , 1025-1040
Fast bound pool fraction mapping via steady‐state magnetization transfer saturation using single‐shot EPI
Purpose: To enable clinical applications of quantitative magnetization transfer (qMT) imaging by developing a fast method to map one of its fundamental model parameters, the bound pool fraction (BPF), in the human brain.Theory and Methods: The theory of steady‐state MT in the fast‐exchange approximation is used to provide measurements of BPF, and bound pool transverse relaxation time (). A sequence that allows sampling of the signal during steady‐state MT saturation is used to perform BPF mapping with a 10‐min‐long fully echo planar imaging‐based MRI protocol, including inversion recovery T1 mapping and B1 error mapping. The approach is applied in 6 healthy subjects and 1 multiple sclerosis patient, and validated against a single‐slice full qMT reference acquisition.Results: BPF measurements are in agreement with literature values using off‐resonance MT, with average BPF of 0.114(0.100‐0.128) in white matter and 0.068(0.054‐0.085) in gray matter. Median voxel‐wise percentage error compared with standard single slice qMT is 4.6%. Slope and intercept of linear regression between new and reference BPF are 0.83(0.81‐0.85) and 0.013(0.11‐0.16). Bland‐Altman plot mean bias is 0.005. In the multiple sclerosis case, the BPF is sensitive to pathological changes in lesions.Conclusion: The method developed provides accurate BPF estimates and enables shorter scan time compared with currently available approaches, demonstrating the potential of bringing myelin sensitive measurement closer to the clinic.
- 12 May 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 82 (3) , 1025-1040
Fast bound pool fraction mapping via steady‐state magnetization transfer saturation using single‐shot EPI
Purpose: To enable clinical applications of quantitative magnetization transfer (qMT) imaging by developing a fast method to map one of its fundamental model parameters, the bound pool fraction (BPF), in the human brain.Theory and Methods: The theory of steady‐state MT in the fast‐exchange approximation is used to provide measurements of BPF, and bound pool transverse relaxation time (). A sequence that allows sampling of the signal during steady‐state MT saturation is used to perform BPF mapping with a 10‐min‐long fully echo planar imaging‐based MRI protocol, including inversion recovery T1 mapping and B1 error mapping. The approach is applied in 6 healthy subjects and 1 multiple sclerosis patient, and validated against a single‐slice full qMT reference acquisition.Results: BPF measurements are in agreement with literature values using off‐resonance MT, with average BPF of 0.114(0.100‐0.128) in white matter and 0.068(0.054‐0.085) in gray matter. Median voxel‐wise percentage error compared with standard single slice qMT is 4.6%. Slope and intercept of linear regression between new and reference BPF are 0.83(0.81‐0.85) and 0.013(0.11‐0.16). Bland‐Altman plot mean bias is 0.005. In the multiple sclerosis case, the BPF is sensitive to pathological changes in lesions.Conclusion: The method developed provides accurate BPF estimates and enables shorter scan time compared with currently available approaches, demonstrating the potential of bringing myelin sensitive measurement closer to the clinic.
- Open Access
- 14 September 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (1) , 362-376
Multiband RF pulse design for realistic gradient performance
Purpose: Simultaneous multi‐slice techniques are reliant on multiband RF pulses, for which conventional design strategies result in long pulse durations, lengthening echo‐times so lowering SNR for spin‐echo imaging, and lengthening repetition times for gradient echo sequences. Pulse durations can be reduced with advanced RF pulse design methods that use time‐variable selection gradients. However, the ability of gradient systems to reproduce fast switching pulses is often limited and can lead to image artifacts when ignored. We propose a time‐efficient pulse design method that inherently produces gradient waveforms with lower temporal bandwidth.Methods: Efficient multiband RF pulses with time‐variable gradients were designed using time‐optimal VERSE. Using VERSE directly on multiband pulses leads to gradient waveforms with high temporal bandwidth, whereas VERSE applied first to singleband RF pulses and then modulated to make them multiband, significantly reduces this. The relative performance of these approaches was compared using simulation and experimental measurements.Results: Applying VERSE before multiband modulation was successful at removing out‐of‐band slice distortion. This effectively removes the need for high frequency modulation in the gradient waveform while preserving the benefit of time‐efficiency inherited from VERSE.Conclusion: We propose a time‐efficient RF pulse design that produces gradient pulses with lower temporal bandwidth, reducing image artifacts associated with finite temporal bandwidth of gradient systems.
- 14 September 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (1) , 362-376
Open AccessMultiband RF pulse design for realistic gradient performance
Purpose: Simultaneous multi‐slice techniques are reliant on multiband RF pulses, for which conventional design strategies result in long pulse durations, lengthening echo‐times so lowering SNR for spin‐echo imaging, and lengthening repetition times for gradient echo sequences. Pulse durations can be reduced with advanced RF pulse design methods that use time‐variable selection gradients. However, the ability of gradient systems to reproduce fast switching pulses is often limited and can lead to image artifacts when ignored. We propose a time‐efficient pulse design method that inherently produces gradient waveforms with lower temporal bandwidth.Methods: Efficient multiband RF pulses with time‐variable gradients were designed using time‐optimal VERSE. Using VERSE directly on multiband pulses leads to gradient waveforms with high temporal bandwidth, whereas VERSE applied first to singleband RF pulses and then modulated to make them multiband, significantly reduces this. The relative performance of these approaches was compared using simulation and experimental measurements.Results: Applying VERSE before multiband modulation was successful at removing out‐of‐band slice distortion. This effectively removes the need for high frequency modulation in the gradient waveform while preserving the benefit of time‐efficiency inherited from VERSE.Conclusion: We propose a time‐efficient RF pulse design that produces gradient pulses with lower temporal bandwidth, reducing image artifacts associated with finite temporal bandwidth of gradient systems.
- Open Access
- 5 September 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (2) , 1247-1264
Relevance of time‐dependence for clinically viable diffusion imaging of the spinal cord
Purpose Time‐dependence is a key feature of the diffusion‐weighted (DW) signal, knowledge of which informs biophysical modelling. Here, we study time‐dependence in the human spinal cord, as its axonal structure is specific and different from the brain. Theory and Methods We run Monte Carlo simulations using a synthetic model of spinal cord white matter (WM) (large axons), and of brain WM (smaller axons). Furthermore, we study clinically feasible multi‐shell DW scans of the cervical spinal cord (b = 0; b = 711 s mm−2; b = 2855 s mm−2), obtained using three diffusion times (Δ of 29, 52 and 76 ms) from three volunteers. Results Both intra‐/extra‐axonal perpendicular diffusivities and kurtosis excess show time‐dependence in our synthetic spinal cord model. This time‐dependence is reflected mostly in the intra‐axonal perpendicular DW signal, which also exhibits strong decay, unlike our brain model. Time‐dependence of the total DW signal appears detectable in the presence of noise in our synthetic spinal cord model, but not in the brain. In WM in vivo, we observe time‐dependent macroscopic and microscopic diffusivities and diffusion kurtosis, NODDI and two‐compartment SMT metrics. Accounting for large axon calibers improves fitting of multi‐compartment models to a minor extent. Conclusions Time‐dependence of clinically viable DW MRI metrics can be detected in vivo in spinal cord WM, thus providing new opportunities for the non‐invasive estimation of microstructural properties. The time‐dependence of the perpendicular DW signal may feature strong intra‐axonal contributions due to large spinal axon caliber. Hence, a popular model known as “stick” (zero‐radius cylinder) may be sub‐optimal to describe signals from the largest spinal axons.
- 5 September 2018
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (2) , 1247-1264
Open AccessRelevance of time‐dependence for clinically viable diffusion imaging of the spinal cord
Purpose Time‐dependence is a key feature of the diffusion‐weighted (DW) signal, knowledge of which informs biophysical modelling. Here, we study time‐dependence in the human spinal cord, as its axonal structure is specific and different from the brain. Theory and Methods We run Monte Carlo simulations using a synthetic model of spinal cord white matter (WM) (large axons), and of brain WM (smaller axons). Furthermore, we study clinically feasible multi‐shell DW scans of the cervical spinal cord (b = 0; b = 711 s mm−2; b = 2855 s mm−2), obtained using three diffusion times (Δ of 29, 52 and 76 ms) from three volunteers. Results Both intra‐/extra‐axonal perpendicular diffusivities and kurtosis excess show time‐dependence in our synthetic spinal cord model. This time‐dependence is reflected mostly in the intra‐axonal perpendicular DW signal, which also exhibits strong decay, unlike our brain model. Time‐dependence of the total DW signal appears detectable in the presence of noise in our synthetic spinal cord model, but not in the brain. In WM in vivo, we observe time‐dependent macroscopic and microscopic diffusivities and diffusion kurtosis, NODDI and two‐compartment SMT metrics. Accounting for large axon calibers improves fitting of multi‐compartment models to a minor extent. Conclusions Time‐dependence of clinically viable DW MRI metrics can be detected in vivo in spinal cord WM, thus providing new opportunities for the non‐invasive estimation of microstructural properties. The time‐dependence of the perpendicular DW signal may feature strong intra‐axonal contributions due to large spinal axon caliber. Hence, a popular model known as “stick” (zero‐radius cylinder) may be sub‐optimal to describe signals from the largest spinal axons.
- 21 November 2017
- Published by SAGE Publications in Respiratory Care
- Vol. 63 (3) , 289-293
Delay Between Shaking and Actuation of a Hydrofluoroalkane Fluticasone Pressurized Metered-Dose Inhaler
BACKGROUND: Inhaled corticosteroids are used to treat pediatric asthma. The shaking of a pressurized metered-dose inhaler (pMDI) is required to ensure consistency of emitted dose. Delays between shaking and actuating the pMDI are frequent during administration of aerosols to children where a valved holding chamber is used. METHODS: In a recent clinical trial, we used a monitoring device to record shaking and actuation of the pMDI and the inhalation profiles of children with asthma while they were inhaling fluticasone hydrofluoroalkane from a valved holding chamber onto an external filter. During the procedure, in vitro and transport samples were generated without a delay between shaking and actuating the pMDI. Emitted dose, expressed as percentage of ex-actuator nominal dose, obtained from the second actuation following a recorded shake-actuation interval for subjects and from in vitro/transport samples (no delay) were compared. RESULTS: The mean emitted dose was 158.6% (95% CI 150.1–167.2%) (subjects) and 106.8% (95% CI 104.7–108.9%) (in vitro + transport) of the ex-actuator nominal dose ( P < .001). The mean delay between shaking and actuating the pMDI was 12.9 s (95% CI 11.9–13.9 s) for the subject samples. A strong correlation was observed between shake and actuation delay and the emitted dose of the second actuation following the delay (Spearman correlation coefficient = 0.61). A 10-, 20-, and 30-s delay resulted in an emitted dose of the second actuation following the delay of 147, 187, and 227% of the ex-actuator nominal dose, respectively. CONCLUSIONS: Delays between shaking and actuating a corticosteroid suspension pMDI resulted in an increase in the emitted dose of the second actuation following the delay. This can be a common occurrence when doses are administered by a caregiver to a patient via a holding chamber. This should be addressed by practitioners educating patients and parents on proper inhaler use. (ClinicalTrials.gov registration NCT01714063.)
- 21 November 2017
- Published by SAGE Publications in Respiratory Care
- Vol. 63 (3) , 289-293
Delay Between Shaking and Actuation of a Hydrofluoroalkane Fluticasone Pressurized Metered-Dose Inhaler
BACKGROUND: Inhaled corticosteroids are used to treat pediatric asthma. The shaking of a pressurized metered-dose inhaler (pMDI) is required to ensure consistency of emitted dose. Delays between shaking and actuating the pMDI are frequent during administration of aerosols to children where a valved holding chamber is used. METHODS: In a recent clinical trial, we used a monitoring device to record shaking and actuation of the pMDI and the inhalation profiles of children with asthma while they were inhaling fluticasone hydrofluoroalkane from a valved holding chamber onto an external filter. During the procedure, in vitro and transport samples were generated without a delay between shaking and actuating the pMDI. Emitted dose, expressed as percentage of ex-actuator nominal dose, obtained from the second actuation following a recorded shake-actuation interval for subjects and from in vitro/transport samples (no delay) were compared. RESULTS: The mean emitted dose was 158.6% (95% CI 150.1–167.2%) (subjects) and 106.8% (95% CI 104.7–108.9%) (in vitro + transport) of the ex-actuator nominal dose ( P < .001). The mean delay between shaking and actuating the pMDI was 12.9 s (95% CI 11.9–13.9 s) for the subject samples. A strong correlation was observed between shake and actuation delay and the emitted dose of the second actuation following the delay (Spearman correlation coefficient = 0.61). A 10-, 20-, and 30-s delay resulted in an emitted dose of the second actuation following the delay of 147, 187, and 227% of the ex-actuator nominal dose, respectively. CONCLUSIONS: Delays between shaking and actuating a corticosteroid suspension pMDI resulted in an increase in the emitted dose of the second actuation following the delay. This can be a common occurrence when doses are administered by a caregiver to a patient via a holding chamber. This should be addressed by practitioners educating patients and parents on proper inhaler use. (ClinicalTrials.gov registration NCT01714063.)
- 1 June 2017
- Published by SAGE Publications in Journal of Aerosol Medicine and Pulmonary Drug Delivery
- Vol. 30 (3) , 182-189
Drug Delivery in Asthmatic Children Following Coordinated and Uncoordinated Inhalation Maneuvers: A Randomized Crossover Trial
Background: Valved holding chambers (VHCs) are used in children to deliver pressurized metered dose inhalers (pMDI). In vitro data suggest that uncoordinated use decreases the amount of drug available for inhalation. We hypothesize that in an ex vivo study, the coordinated maneuver will deliver more drug than the uncoordinated one. Patients and Methods: Thirty-two clinically stable asthmatic children, ages 5–8 years, completed the study. An aerosol filter was interposed between a small-volume nonelectrostatic VHC and a mouthpiece to capture the drug emitted by one puff of Flovent® 220 mcg during tidal breathing. Inhalation and actuation parameters were measured by an electronic monitor, and the number of breaths required to empty the VHC was calculated. Subjects completed three coordinated and three uncoordinated (actuation at the beginning of inhalation and exhalation, respectively) runs in random order. Drug content from the filter and VHC was measured by high-performance liquid chromatography and expressed as percentage of emitted dose. Results: [mean (99% confidence interval)] Filter dose was higher during coordinated technique 46% (43%–50%) than during uncoordinated technique 41% (37%–44%) (p < 0.001). Peak inspiratory flow and tidal volume were 23.2 L/min (21.3–25.1 L/min) and 281 mL (251–311 mL), respectively. Subjects required three breaths to empty the VHC in 96% of the tests. Conclusions: Actuating the pMDI into a small-volume nonelectrostatic VHC during exhalation reduced by 11% the amount of fluticasone captured at the exit of the VHC. Asthmatic children (5–8 years old) need three or less breaths to empty the small-volume VHC (NCT01714063).
- 1 June 2017
- Published by SAGE Publications in Journal of Aerosol Medicine and Pulmonary Drug Delivery
- Vol. 30 (3) , 182-189
Drug Delivery in Asthmatic Children Following Coordinated and Uncoordinated Inhalation Maneuvers: A Randomized Crossover Trial
Background: Valved holding chambers (VHCs) are used in children to deliver pressurized metered dose inhalers (pMDI). In vitro data suggest that uncoordinated use decreases the amount of drug available for inhalation. We hypothesize that in an ex vivo study, the coordinated maneuver will deliver more drug than the uncoordinated one. Patients and Methods: Thirty-two clinically stable asthmatic children, ages 5–8 years, completed the study. An aerosol filter was interposed between a small-volume nonelectrostatic VHC and a mouthpiece to capture the drug emitted by one puff of Flovent® 220 mcg during tidal breathing. Inhalation and actuation parameters were measured by an electronic monitor, and the number of breaths required to empty the VHC was calculated. Subjects completed three coordinated and three uncoordinated (actuation at the beginning of inhalation and exhalation, respectively) runs in random order. Drug content from the filter and VHC was measured by high-performance liquid chromatography and expressed as percentage of emitted dose. Results: [mean (99% confidence interval)] Filter dose was higher during coordinated technique 46% (43%–50%) than during uncoordinated technique 41% (37%–44%) (p < 0.001). Peak inspiratory flow and tidal volume were 23.2 L/min (21.3–25.1 L/min) and 281 mL (251–311 mL), respectively. Subjects required three breaths to empty the VHC in 96% of the tests. Conclusions: Actuating the pMDI into a small-volume nonelectrostatic VHC during exhalation reduced by 11% the amount of fluticasone captured at the exit of the VHC. Asthmatic children (5–8 years old) need three or less breaths to empty the small-volume VHC (NCT01714063).
- 12 June 2015
- Published by Informa Healthcare in Expert Opinion on Drug Delivery
- Vol. 12 (11) , 1755-1765
Industry guidance for the selection of a delivery system for the development of novel respiratory products
Respiratory diseases remain a target for improved forms of inhalation therapy. However, there are neither regulatory preferences for one type of device over another, nor well-recognized guidelines. This guidance describes factors that should be considered to optimize the choice of delivery system. This article summarizes the different types of delivery systems with key technical and commercial considerations for selection. It highlights current market trends and opportunities for the future, based on the author's experience of more than 20 years in this field. For a generic drug, low device cost favors a capsule dry powder inhaler (DPI) or a propellant-based metered-dose inhaler (pMDI). Novel particle engineering approaches may allow close matching to the innovator product performance. For novel drugs, most companies favor a bespoke DPI, adding patent protection and aiding brand recognition, despite being expensive to develop. Device features may add differentiation, but "no outcome, no income." Patient technique and adherence remain problematic, compounded by age, although accessories, including monitors, can help. There are few modern medicines available in nebulized form, so there is value in fast-tracking the nebulized formulations from Phase I studies through to market in parallel to the chosen inhaler.
- 12 June 2015
- Published by Informa Healthcare in Expert Opinion on Drug Delivery
- Vol. 12 (11) , 1755-1765
Industry guidance for the selection of a delivery system for the development of novel respiratory products
Respiratory diseases remain a target for improved forms of inhalation therapy. However, there are neither regulatory preferences for one type of device over another, nor well-recognized guidelines. This guidance describes factors that should be considered to optimize the choice of delivery system. This article summarizes the different types of delivery systems with key technical and commercial considerations for selection. It highlights current market trends and opportunities for the future, based on the author's experience of more than 20 years in this field. For a generic drug, low device cost favors a capsule dry powder inhaler (DPI) or a propellant-based metered-dose inhaler (pMDI). Novel particle engineering approaches may allow close matching to the innovator product performance. For novel drugs, most companies favor a bespoke DPI, adding patent protection and aiding brand recognition, despite being expensive to develop. Device features may add differentiation, but "no outcome, no income." Patient technique and adherence remain problematic, compounded by age, although accessories, including monitors, can help. There are few modern medicines available in nebulized form, so there is value in fast-tracking the nebulized formulations from Phase I studies through to market in parallel to the chosen inhaler.
- Open Access
- 20 September 2012
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7 (9) , e43702
Comparison of Venous and Capillary Differential Leukocyte Counts Using a Standard Hematology Analyzer and a Novel Microfluidic Impedance Cytometer
Capillary blood sampling has been identified as a potentially suitable technique for use in diagnostic testing of the full blood count (FBC) at the point-of-care (POC), for which a recent need has been highlighted. In this study we assess the accuracy of capillary blood counts and evaluate the potential of a miniaturized cytometer developed for POC testing. Differential leukocyte counts in the normal clinical range from fingerprick (capillary) and venous blood samples were measured and compared using a standard hematology analyzer. The accuracy of our novel microfluidic impedance cytometer (MIC) was then tested by comparing same-site measurements to those obtained with the standard analyzer. The concordance between measurements of fingerprick and venous blood samples using the standard hematology analyzer was high, with no clinically relevant differences observed between the mean differential leukocyte counts. Concordance data between the MIC and the standard analyzer on same-site measurements presented significantly lower leukocyte counts determined by the MIC. This systematic undercount was consistent across the measured (normal) concentration range, suggesting that an internal correction factor could be applied. Differential leukocyte counts obtained from fingerprick samples accurately reflect those from venous blood, which confirms the potential of capillary blood sampling for POC testing of the FBC. Furthermore, the MIC device demonstrated here presents a realistic technology for the future development of FBC and related tests for use at the site of patient care.
- 20 September 2012
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7 (9) , e43702
Open AccessComparison of Venous and Capillary Differential Leukocyte Counts Using a Standard Hematology Analyzer and a Novel Microfluidic Impedance Cytometer
Capillary blood sampling has been identified as a potentially suitable technique for use in diagnostic testing of the full blood count (FBC) at the point-of-care (POC), for which a recent need has been highlighted. In this study we assess the accuracy of capillary blood counts and evaluate the potential of a miniaturized cytometer developed for POC testing. Differential leukocyte counts in the normal clinical range from fingerprick (capillary) and venous blood samples were measured and compared using a standard hematology analyzer. The accuracy of our novel microfluidic impedance cytometer (MIC) was then tested by comparing same-site measurements to those obtained with the standard analyzer. The concordance between measurements of fingerprick and venous blood samples using the standard hematology analyzer was high, with no clinically relevant differences observed between the mean differential leukocyte counts. Concordance data between the MIC and the standard analyzer on same-site measurements presented significantly lower leukocyte counts determined by the MIC. This systematic undercount was consistent across the measured (normal) concentration range, suggesting that an internal correction factor could be applied. Differential leukocyte counts obtained from fingerprick samples accurately reflect those from venous blood, which confirms the potential of capillary blood sampling for POC testing of the FBC. Furthermore, the MIC device demonstrated here presents a realistic technology for the future development of FBC and related tests for use at the site of patient care.