Type
Company
Locations
Rüsselsheim am Main, Germany
Relationships
Parent Organizations

Latest Publications

  • Fundamental Study of GPF Performance on Soot and Ash Accumulation over Artemis Urban and Motorway Cycles - Comparison of Engine Bench Results with GPF Durability Study on Road

    by Lauretta Rubino, Dominic Thier, Torsten Schumann, Stefan Guettler, Gerald Russ

    With the increased use of engines utilizing direct fuel injection and the upcoming introduction of more stringent emissions legislation that regulates not only particulate mass (PM) but also particulate number (PN), the emissions from Direct Injection Spark Ignition Engines (DISI) are an increasing concern. Gasoline Particle Filters (GPF) represent a potential way to reduce particle number emissions from DISI engines and are particularly effective considering the tough performance requirements during cold start and over RDE operation. Even though some learning from the development and application of particulate filters to diesel engines can be transferred to gasoline engines, the particle composition, mass to number ratio as well as the exhaust gas temperature and composition from gasoline engines are significantly different to diesel engines. Therefore, there is the need to study the application of particulate filters to gasoline engines in more depth. Of particular concern, is the understanding of the ash accumulation mechanism within the GPF and its negative impact on the backpressure over lifetime.This paper presents the results from a fundamental study of an uncoated ceramic GPF in the exhaust after-treatment system of a 1.6 litre turbo DISI engine. Soot and ash accumulation data are reported comparing two aggressive driving cycles (Artemis Urban vs. Artemis Motorway). Each cycle was operated for 20k km on a dynamic engine bench. PN emissions were then measured over WLTC and NEDC test cycles after 20k km. The results are discussed with respect to the differences from each cycle for the ash formation and backpressure increase; it also considers the possibility of extrapolating the results to a more balanced driving pattern over 160k km. Results from the engine bench investigation are compared to a vehicle durability run, using the same engine and type of GPF in the under-floor (UF) location.Results show PN filtration efficiency of the GPF, above 70% in fresh condition and above 90% with increasing mileage. Further, low soot accumulation and low ash amounts were detected after the durability run was completed. Ash is mainly related to the oil consumption of the engine and small differences were observed between the two Artemis cycles. In particular the Artemis Urban cycle shows higher ash amount over 20k km (1.26 g/l) compared to the Artemis Motorway (0.4 g/l). These ash values from the engine bench correlate well with the findings of the vehicle durability run. Post mortem analysis (PMA) of the GPF after both engine bench and vehicle durability tests are also reported.


  • Evaluating Performance of Uncoated GPF in Real World Driving Using Experimental Results and CFD modelling

    by Lauretta Rubino, Jan Piotr Oles, Antonino La Rocca

    Environmental authorities such as EPA, VCA have enforced stringent emissions legislation governing air pollutants released into the atmosphere. Of particular interest is the challenge introduced by the limit on particulate number (PN) counting (#/km) and real driving emissions (RDE) testing; with new emissions legislation being shortly introduced for the gasoline direct injection (GDI) engines, gasoline particulate filters (GPF) are considered the most immediate solution. While engine calibration and testing over the Worldwide harmonized Light vehicles Test Cycle (WLTC) allow for the limits to be met, real driving emission and cold start constitute a real challenge.The present work focuses on an experimental durability study on road under real world driving conditions. Two sets of experiments were carried out. The first study analyzed a gasoline particulate filter (GPF) (2.4 liter, diameter 5.2” round) installed in the underfloor (UF) position and driven up to 200k km. A 1.6 liter Gasoline Direct Injection (GDI) engine was used for the investigation. Ash accumulation versus mileage and soot loading were of interest. A parallel investigation up to 160k km with same engine (2 identical vehicles on an “average customer driving” cycle) and GPF installed in close-coupled (CC) position was also carried out. Both UF and CC GPF are NGK 360 cpsi (i.e. cells per square inch), 5 mil wall thickness.As a route to develop a robust 3-D Computational Fluid Dynamics (CFD) model to gather information on the fluid flow and pressure loss characteristics of GPF, a baseline model is introduced in this work. The computational domain refers to full length individual 3-D channels and focuses on two quarters of an inlet and two quarters of an outlet channel with the aim of reducing complexity of the problem and its computational cost. Although this baseline version does not include yet the soot and ash loading models, it can be used for understanding real physical problems and gather insight on velocity and pressure distributions inside filter and its channels.


  • Air Cooling Concepts for Li-Ion Battery Pack in Cell Level

    by Kuo-Huey Chen, Taeyoung Han, Bahram Khalighi, Philip Klaus

    Computational Fluid Dynamics (CFD) modeling is used to study different cooling architectures for the next generation (Gen-2) EREV Li-Ion battery package. There might be advantages of air cooled batteries with respect to complexity, cost and reliability compared to liquid cooled systems like the EREV (Extended Range Electric Vehicle) GEN1 battery. Therefore, the feasibility of air cooling architectures is investigated first and later liquid cooling strategies. In this study, the thermal performance and pressure drop of the cell level for two of the core product designs are reported. The parameters considered in this study include two different heat generations (heat sources) by the battery pack and three cooling flow rates. The heat generations used are 500 W and 1500 W representing the normal driving and peak load conditions, respectively. The cooling flow rates are 100, 200 and 600 m3/h. The battery cell temperatures, both in terms of absolute value and the variation within the cell, and the pressure drop which is related to the required pumping power, are evaluated and presented.


  • Laser-based Measurements for Validation of Numerical Simulations

    by Elias Baum, Brian Peterson, Benjamin Böhm, Andreas Dreizler

  • Understanding the complex needs of automotive training at final assembly lines

    by Setia Hermawati, Glyn Lawson, Mirabelle D'CRuz, Frank Arlt, Judith Apold, Lina Andersson, Maria Gink Lövgren, Lennart Malmsköld


  • Manual Transmissions

    by Rolf Krüttgen, Christian Kunze, Wolfgang Geis‐Drescher, Arnold Paluch

  • Internal Heat Exchanger Integration for a Dual Evaporator MAC System

    by Lothar Seybold, William Hill, Ioannis Lazaridis

    The United States Environmental Protection Agency (EPA) as well as the European Commission (EC) are developing test procedures to regulate mobile air conditioning system (MAC) efficiency to reduce greenhouse gas emissions and reduce global warming. In the United States, air conditioning related MAC credits can be earned by implementing an internal heat exchanger (IHX) into a MAC system. By integrating an IHX into a MAC system the, Coefficient of Performance (COP) can be increased at the same time increasing cooling capacity. This improvement in efficiency reduces the energy and/or fuel consumption of the MAC system.This paper will compare various IHX plumbing configurations for a dual evaporator system with R1234yf refrigerant. A MAC system optimized for efficiency as well as evaporator cooling capacity is used to assess these different IHX plumbing configurations. Factors that will be considered include IHX heat transfer rate, suction pressure drop, and the impact of these factors on the COP and cooling capacity. The optimal IHX plumbing configuration for this dual evaporator system will be identified and its integration into the vehicle discussed. This paper also describes the MAC system, test facility used and the testing procedure applied.


  • Top Cited Papers

    Fuel cell electric vehicles and hydrogen infrastructure: status 2012

    by Ulrich Eberle, Bernd Müller, Rittmar von Helmolt

    A graphical abstract is available for this content


  • Predictive maneuver evaluation for enhancement of Car-to-X mobility data

    by Jonas Firl, Hagen Stubing, Sorin A. Huss, Christoph Stiller

    Advanced Driver Assistance Systems (ADAS) employ single object information to provide safety, comfort, or infotainment features. The required data is mainly extracted from external sensors to recognize and predict the future states of relevant traffic participants. Next generation ADAS will also use data from additional sources like, e.g., Car-to-X communication networks, to avoid some typical restrictions of common sensor setups. In this work, we present a method, which uses information on other traffic participants, and furthermore recognizes and considers their interactions in terms of traffic maneuvers to better predict their states. For this purpose, a probabilistic framework is presented, which recognizes object interactions as well as different road characteristics by introducing local, adaptive occupancy grids. The resulting maneuver recognition is shown to considerably improve received mobility data in terms of position, speed, and heading. These concepts have been fully implemented and evaluated by means of real world experiments.