Loccioni (Italy)
Types
Company, FunderLocations
Ancona, ItalyLatest Publications
- 11 March 2025
- Published by BMJ
- Vol. 32 (Suppl 1) , A18.2-A19
3PC-002 Evaluation study of a paediatric non-hazardous robotic compounding system: is it safe and dose accurate?
Background and Importance Robotic-compounding-systems (RCS) ensure parental medications through fully automated system controlled by a software. To reduce the working area’s contaminations and medication errors during paediatric manipulations, a new RCS was located into our Hospital Pharmacy’s centralised intravenous additive service (CIVAS) in 2021. APOTECAped can compound standard-dose/personalised paediatric medications into appropriate final containers; all equipment used is carried out into the clean room through a barcode-system. It guarantees an aseptic process thanks to HEPA filters and a controlled environment. Aim and Objectives With this work we evaluated APOTECAped’s productivity (total compounding time, dose accuracy) and drugs’ sterility. Material and Methods APOTECAped’s productivity was evaluated in a production batch of 10 Pantoprazole 4 mg/ml 10 ml and 10 Cefotaxime 50 mg/ml 20 ml syringes (data collected from APOTECAped’s final reports); dose accuracy was analysed through gravimetric and volumetric controls. Bacteria and fungi’s contamination was tested by the Hospital’s Hygiene Department at time 0 and after 7 days from preparation (one syringe of each drug each time) after inoculation into TSB broth solutions and incubation for 7 days. Endotoxins’ quantification was done by the hospital pharmacist using a chromogenic kinetik LAL-test method. The Endotoxines-Limit (EL) was 4,17 EU/mg for Pantoprazole (data based on the maximum dose administered to a paediatric patient) and 0,05 UE/mg for Cefotaxime (data from European Pharmacopoeia). We calculated the maximum dilution volume (MDV) to avoid interferences during test; for our analysis we used MDV/2 (1:800 for pantoprazole, 1:125 for cefotaxime). Results Pantoprazole syringes were prepared using 40 mg lyophilised powder and 10 ml of NaCl 0,9% solution; mean of dose error was – 3,87%, total time to make the production batch was 57 minutes (approximately 5 minutes/syringe). Cefotaxime syringes were prepared using 1000 mg lyophilised powder, 4 ml of sterile-injectable-water (reconstitution) and 16 ml of NaCl 0,9% (dilution); mean of dose error was −2,12%, total time to make the production batch was 88 minutes (approximately 8 minutes/syringe). Microbiological tests demonstrated the absence of bacteria and fungi’s growth, LAL-test that the endotoxins’ quantification was under the EL. Conclusion and Relevance APOTECAped guaranteed dose accuracy and drug sterility during the compounding. Even if the total robotic preparation time was longer than manual, RCS could reduce human errors and increase drug safety. Conflict of Interest No conflict of interest
- 11 March 2025
- Published by BMJ
- Vol. 32 (Suppl 1) , A18.2-A19
3PC-002 Evaluation study of a paediatric non-hazardous robotic compounding system: is it safe and dose accurate?
Background and Importance Robotic-compounding-systems (RCS) ensure parental medications through fully automated system controlled by a software. To reduce the working area’s contaminations and medication errors during paediatric manipulations, a new RCS was located into our Hospital Pharmacy’s centralised intravenous additive service (CIVAS) in 2021. APOTECAped can compound standard-dose/personalised paediatric medications into appropriate final containers; all equipment used is carried out into the clean room through a barcode-system. It guarantees an aseptic process thanks to HEPA filters and a controlled environment. Aim and Objectives With this work we evaluated APOTECAped’s productivity (total compounding time, dose accuracy) and drugs’ sterility. Material and Methods APOTECAped’s productivity was evaluated in a production batch of 10 Pantoprazole 4 mg/ml 10 ml and 10 Cefotaxime 50 mg/ml 20 ml syringes (data collected from APOTECAped’s final reports); dose accuracy was analysed through gravimetric and volumetric controls. Bacteria and fungi’s contamination was tested by the Hospital’s Hygiene Department at time 0 and after 7 days from preparation (one syringe of each drug each time) after inoculation into TSB broth solutions and incubation for 7 days. Endotoxins’ quantification was done by the hospital pharmacist using a chromogenic kinetik LAL-test method. The Endotoxines-Limit (EL) was 4,17 EU/mg for Pantoprazole (data based on the maximum dose administered to a paediatric patient) and 0,05 UE/mg for Cefotaxime (data from European Pharmacopoeia). We calculated the maximum dilution volume (MDV) to avoid interferences during test; for our analysis we used MDV/2 (1:800 for pantoprazole, 1:125 for cefotaxime). Results Pantoprazole syringes were prepared using 40 mg lyophilised powder and 10 ml of NaCl 0,9% solution; mean of dose error was – 3,87%, total time to make the production batch was 57 minutes (approximately 5 minutes/syringe). Cefotaxime syringes were prepared using 1000 mg lyophilised powder, 4 ml of sterile-injectable-water (reconstitution) and 16 ml of NaCl 0,9% (dilution); mean of dose error was −2,12%, total time to make the production batch was 88 minutes (approximately 8 minutes/syringe). Microbiological tests demonstrated the absence of bacteria and fungi’s growth, LAL-test that the endotoxins’ quantification was under the EL. Conclusion and Relevance APOTECAped guaranteed dose accuracy and drug sterility during the compounding. Even if the total robotic preparation time was longer than manual, RCS could reduce human errors and increase drug safety. Conflict of Interest No conflict of interest
- Open Access
- 28 October 2023
- Published by Oxford University Press (OUP) in International Journal of Pharmacy Practice
- Vol. 32 (1) , 97-99
Centralization and automation of non-toxic drug reconstitution in the pharmacy: a strengths, weaknesses, opportunities, and threats analysis
Some commercially available medicines are marketed in such a way that they are Ready-To-Administer (RTA). This means that the product is presented in the final container at the right dose and in the right volume. However, most drugs used for infusions or injections in hospitals require one or more handling steps before they can be administered. This process is called reconstitution and is defined as manipulation to enable the use or application of a medicinal product with a marketing authorization in accordance with the instructions given in the summary of product characteristics (SmPC) or the patient information leaflet [ 1]. Infusions and injections, also referred to as drugs for parenteral use, are considered high-risk because the route of administration inherently requires an absence of microbiological contamination. Dosing errors or incorrect product formulation following reconstitution may also lead to more serious consequences than in, for example, oral or cutaneous administration. Unfortunately, multiple studies have shown high error rates associated with the reconstitution of injectable medicines. Hedlund et al. collated results on admixture drug preparation errors from 34 independent studies [ 2]; error rates ranged in their analysis, for example, for wrong drug (0%–4.7%), wrong concentration (0.3%–88.6%), and inadequate aseptic technique (0%––92.7%). Centralizing reconstitution in the hospital pharmacy has the potential to reduce errors, as was shown in a study comparing ward and pharmacy as reconstitution settings (errors decreased from 53% to 16%) [ 3]. It can also increase the microbiological safety, which was demonstrated in another study with a similar design (1.1% of contamination when reconstitution was performed by nurses on a ward versus 0% in the pharmacy) [ 4]. Errors in reconstitution practices can result in patient harm, such as unnecessary side effects, failure of therapy, and (prolonged) hospitalization [ 2]. To enhance the quality of parenteral drugs in healthcare establishments, the council of Europe issued a resolution in 2016. This resolution gives guidance on how to best ensure the quality of reconstitution practices, taking into account that the highest quality standards could be reached by having all reconstitution taking place in aseptic units in the pharmacy [ 1]. However, the operating capacity of hospital pharmacies is on not sufficient to accommodate this. In this respect, automation can be helpful, as it has been shown to mitigate the number of required pharmacy staff in chemotherapy preparation [ 5, 6] while attaining high-quality products. Studies on non-chemotherapy or non-toxic drug reconstitution centralization and/or automation with regard to macro benefits are as yet, largely lacking. To our knowledge, only one country (England) has looked into this scheme and provided an analysis of the potential benefits and savings, calculating the release of up to 4000 full-time equivalents of nurses [ 7]. Fte is calculated by adding up the hours of the full-time and part-time employees and then calculating how many employees that would be if all worked full time. Thus, 1 fte equals one full-time worker.
- 28 October 2023
- Published by Oxford University Press (OUP) in International Journal of Pharmacy Practice
- Vol. 32 (1) , 97-99
Open AccessCentralization and automation of non-toxic drug reconstitution in the pharmacy: a strengths, weaknesses, opportunities, and threats analysis
Some commercially available medicines are marketed in such a way that they are Ready-To-Administer (RTA). This means that the product is presented in the final container at the right dose and in the right volume. However, most drugs used for infusions or injections in hospitals require one or more handling steps before they can be administered. This process is called reconstitution and is defined as manipulation to enable the use or application of a medicinal product with a marketing authorization in accordance with the instructions given in the summary of product characteristics (SmPC) or the patient information leaflet [ 1]. Infusions and injections, also referred to as drugs for parenteral use, are considered high-risk because the route of administration inherently requires an absence of microbiological contamination. Dosing errors or incorrect product formulation following reconstitution may also lead to more serious consequences than in, for example, oral or cutaneous administration. Unfortunately, multiple studies have shown high error rates associated with the reconstitution of injectable medicines. Hedlund et al. collated results on admixture drug preparation errors from 34 independent studies [ 2]; error rates ranged in their analysis, for example, for wrong drug (0%–4.7%), wrong concentration (0.3%–88.6%), and inadequate aseptic technique (0%––92.7%). Centralizing reconstitution in the hospital pharmacy has the potential to reduce errors, as was shown in a study comparing ward and pharmacy as reconstitution settings (errors decreased from 53% to 16%) [ 3]. It can also increase the microbiological safety, which was demonstrated in another study with a similar design (1.1% of contamination when reconstitution was performed by nurses on a ward versus 0% in the pharmacy) [ 4]. Errors in reconstitution practices can result in patient harm, such as unnecessary side effects, failure of therapy, and (prolonged) hospitalization [ 2]. To enhance the quality of parenteral drugs in healthcare establishments, the council of Europe issued a resolution in 2016. This resolution gives guidance on how to best ensure the quality of reconstitution practices, taking into account that the highest quality standards could be reached by having all reconstitution taking place in aseptic units in the pharmacy [ 1]. However, the operating capacity of hospital pharmacies is on not sufficient to accommodate this. In this respect, automation can be helpful, as it has been shown to mitigate the number of required pharmacy staff in chemotherapy preparation [ 5, 6] while attaining high-quality products. Studies on non-chemotherapy or non-toxic drug reconstitution centralization and/or automation with regard to macro benefits are as yet, largely lacking. To our knowledge, only one country (England) has looked into this scheme and provided an analysis of the potential benefits and savings, calculating the release of up to 4000 full-time equivalents of nurses [ 7]. Fte is calculated by adding up the hours of the full-time and part-time employees and then calculating how many employees that would be if all worked full time. Thus, 1 fte equals one full-time worker.
- 14 July 2023
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 112 (9) , 2389-2392
Efficacy of UV and UV-LEDs Irradiation Models for Microbial Inactivation Applicable to Automated Sterile Drug Compounding
- 14 July 2023
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 112 (9) , 2389-2392
Efficacy of UV and UV-LEDs Irradiation Models for Microbial Inactivation Applicable to Automated Sterile Drug Compounding
- Open Access
- 28 September 2022
- Published by SAGE Publications in Journal of Oncology Pharmacy Practice
- Vol. 29 (1) , 208-210
Automated chemotherapy compounding: Process optimization for the preparation of admixture containing high-dose of cyclophosphamide
- 28 September 2022
- Published by SAGE Publications in Journal of Oncology Pharmacy Practice
- Vol. 29 (1) , 208-210
Open AccessAutomated chemotherapy compounding: Process optimization for the preparation of admixture containing high-dose of cyclophosphamide
- Open Access
- 14 March 2021
- Published by BMJ
- Vol. 28 (Suppl 1) , A22.1-A22
3PC-071 Fully automated central intravenous additive service (CIVAS): a 12 month analysis of performances and impact of COVID-19 on sterile antibiotic production
Background and importance In 2014, the hospital pharmacy started a project to implement a central intravenous additive service (CIVAS) unit. A pre-feasibility study was performed, a new class C clean room equipped with the robotic system APOTECA unit was built and the fully automated aseptic production process was validated. In 2016, the CIVAS started producing standard doses of chemotherapy supportive treatments (palonosetron, ondansetron, dexamethasone) in ready-to-administer form for the oncology and haematology units. The production was then shifted to antibiotics (cefazolin, piperacillin–tazobactam, ceftriaxone) and pantoprazole for infectious disease, cardiac surgery and emergency medicine departments. Currently, the in-advance production of batch preparations at CIVAS is mainly based on daily consumption and performed by one pharmacy technician and one pharmacist (0.25 full time equivalent each). The working day is from 8am to 4pm (Monday–Friday). Aim and objectives The aim of this study was to analyse the performance of the CIVAS over the past year and evaluate the impact of the COVID-19 pandemic on the increasing demands for sterile antibiotics by emergency departments. Material and methods Overall CIVAS production, dosage accuracy and average production time (APT) of each ready-to-administer preparation were evaluated over a period of 12 months (from September 2019 to August 2020). Data were collected from the APOTECA statistical tool. Results 12 215 preparations were compounded, of which 26% were in syringe (1 g cefazolin, APT 125 s) and 74% in 100 mL NaCl 0.9% infusion bags (55% for 4.5 g piperacillin–tazobactam, ATP 203 s; 14% for 40 mg pantoprazole, ATP 196 s; 5% for 2 g ceftriaxone, ATP 177 s). Average dosage accuracy for all preparations was 98.9±1%. During the peak of Italy’s COVID-19 outbreak (March 2020), weekly production increased by 28%. The production of pantoprazole remained steady, while piperacillin–tazobactam and ceftriaxone for the emergency departments increased considerably (+19% and 9%, respectively) and cefazolin for the cardiac surgery department decreased by 26%. Conclusion and relevance Implementation of a fully automated CIVAS allows measuring and controlling every step of the production process for ready-to-administer preparations. The study showed that CIVAS met increasing demands for sterile antibiotics during the pandemic crisis, thereby supporting the emergency units and providing the highest level of quality and safety. References and/or acknowledgements Bufarini C. Centralised non-hazardous intravenous compounding: improvement of clinical practice. Eur J Hosp Pharm 2018. Conflict of interest No conflict of interest
- 14 March 2021
- Published by BMJ
- Vol. 28 (Suppl 1) , A22.1-A22
Open Access3PC-071 Fully automated central intravenous additive service (CIVAS): a 12 month analysis of performances and impact of COVID-19 on sterile antibiotic production
Background and importance In 2014, the hospital pharmacy started a project to implement a central intravenous additive service (CIVAS) unit. A pre-feasibility study was performed, a new class C clean room equipped with the robotic system APOTECA unit was built and the fully automated aseptic production process was validated. In 2016, the CIVAS started producing standard doses of chemotherapy supportive treatments (palonosetron, ondansetron, dexamethasone) in ready-to-administer form for the oncology and haematology units. The production was then shifted to antibiotics (cefazolin, piperacillin–tazobactam, ceftriaxone) and pantoprazole for infectious disease, cardiac surgery and emergency medicine departments. Currently, the in-advance production of batch preparations at CIVAS is mainly based on daily consumption and performed by one pharmacy technician and one pharmacist (0.25 full time equivalent each). The working day is from 8am to 4pm (Monday–Friday). Aim and objectives The aim of this study was to analyse the performance of the CIVAS over the past year and evaluate the impact of the COVID-19 pandemic on the increasing demands for sterile antibiotics by emergency departments. Material and methods Overall CIVAS production, dosage accuracy and average production time (APT) of each ready-to-administer preparation were evaluated over a period of 12 months (from September 2019 to August 2020). Data were collected from the APOTECA statistical tool. Results 12 215 preparations were compounded, of which 26% were in syringe (1 g cefazolin, APT 125 s) and 74% in 100 mL NaCl 0.9% infusion bags (55% for 4.5 g piperacillin–tazobactam, ATP 203 s; 14% for 40 mg pantoprazole, ATP 196 s; 5% for 2 g ceftriaxone, ATP 177 s). Average dosage accuracy for all preparations was 98.9±1%. During the peak of Italy’s COVID-19 outbreak (March 2020), weekly production increased by 28%. The production of pantoprazole remained steady, while piperacillin–tazobactam and ceftriaxone for the emergency departments increased considerably (+19% and 9%, respectively) and cefazolin for the cardiac surgery department decreased by 26%. Conclusion and relevance Implementation of a fully automated CIVAS allows measuring and controlling every step of the production process for ready-to-administer preparations. The study showed that CIVAS met increasing demands for sterile antibiotics during the pandemic crisis, thereby supporting the emergency units and providing the highest level of quality and safety. References and/or acknowledgements Bufarini C. Centralised non-hazardous intravenous compounding: improvement of clinical practice. Eur J Hosp Pharm 2018. Conflict of interest No conflict of interest
- Open Access
- 14 March 2021
- Published by BMJ
- Vol. 28 (Suppl 1) , A106.1-A106
4CPS-385 Impact of fully automatised central intravenous additive service (CIVAS) on daily nursing practice
Background and importance The introduction of the pharmacy based central intravenous additive service (CIVAS) enabled the batches production of ready-to-administer, non-hazardous intravenous drugs by using the robotic system APOTECAunit. The clinical benefits in terms of a higher quality aseptic process, reduced medication errors and increased quality control testing have been demonstrated. Aim and objectives The aim of the study was to evaluate the impact of the fully automatised CIVAS on the working efficiency of the wards by measuring the time saved in daily nursing practice. Material and methods The study was conducted over 3 months with data collected before and after introducing the CIVAS. Overall, three wards were analysed: inpatient haematology (IH), cardiac surgical (CS) and infectious diseases (ID). The nursing staff was observed daily for 4 weeks. Different tasks associated with the following intravenous drugs supplied by the CIVAS were recorded: ondansetron, palonosetron, cefazoline, piperacillin–tazobactam, ceftriaxone and dexamethasone. The average working time spent on managing intravenous drugs was calculated per full time equivalent (FTE), including direct activities (intravenous drug preparation) and indirect activities (procurement of drugs and medical devices, drugs inventory management, drug ordering). 1.0 FTE was equivalent to a nurse working 8.0 hours per day, 5 days per week. Results The overall time spent on managing intravenous drugs decreased from 1.6 to 0.7 hours/day/FTE in the IH ward, from 0.75 to 0.15 hours/day/FTE in the CS ward and from 2.1 to 0.43 hours/day/FTE in the ID ward. Before implementing the CIVAS, on average 1.0 FTE spent 0.5 hours/day on preparing intravenous drugs, whereas the intravenous drug preparation time was reduced to zero afterwards in each of the three wards. The time spent on procurement decreased by 80% in the IH ward, by 60% in the CS ward and by 75% in the ID ward. The nursing staff shortened the time required for drug inventory management by 33% in the CS ward and by 50% in the IH and ID wards. In all wards, ordering of drugs was reduced by at least 50%. Conclusion and relevance The study showed that the centralised, automated preparation of intravenous drugs optimised the working efficiency of the wards, thereby allowing the nursing staff to dedicate more time to perform tasks directly involved with patient care. Conflict of interest No conflict of interest
- 14 March 2021
- Published by BMJ
- Vol. 28 (Suppl 1) , A106.1-A106
Open Access4CPS-385 Impact of fully automatised central intravenous additive service (CIVAS) on daily nursing practice
Background and importance The introduction of the pharmacy based central intravenous additive service (CIVAS) enabled the batches production of ready-to-administer, non-hazardous intravenous drugs by using the robotic system APOTECAunit. The clinical benefits in terms of a higher quality aseptic process, reduced medication errors and increased quality control testing have been demonstrated. Aim and objectives The aim of the study was to evaluate the impact of the fully automatised CIVAS on the working efficiency of the wards by measuring the time saved in daily nursing practice. Material and methods The study was conducted over 3 months with data collected before and after introducing the CIVAS. Overall, three wards were analysed: inpatient haematology (IH), cardiac surgical (CS) and infectious diseases (ID). The nursing staff was observed daily for 4 weeks. Different tasks associated with the following intravenous drugs supplied by the CIVAS were recorded: ondansetron, palonosetron, cefazoline, piperacillin–tazobactam, ceftriaxone and dexamethasone. The average working time spent on managing intravenous drugs was calculated per full time equivalent (FTE), including direct activities (intravenous drug preparation) and indirect activities (procurement of drugs and medical devices, drugs inventory management, drug ordering). 1.0 FTE was equivalent to a nurse working 8.0 hours per day, 5 days per week. Results The overall time spent on managing intravenous drugs decreased from 1.6 to 0.7 hours/day/FTE in the IH ward, from 0.75 to 0.15 hours/day/FTE in the CS ward and from 2.1 to 0.43 hours/day/FTE in the ID ward. Before implementing the CIVAS, on average 1.0 FTE spent 0.5 hours/day on preparing intravenous drugs, whereas the intravenous drug preparation time was reduced to zero afterwards in each of the three wards. The time spent on procurement decreased by 80% in the IH ward, by 60% in the CS ward and by 75% in the ID ward. The nursing staff shortened the time required for drug inventory management by 33% in the CS ward and by 50% in the IH and ID wards. In all wards, ordering of drugs was reduced by at least 50%. Conclusion and relevance The study showed that the centralised, automated preparation of intravenous drugs optimised the working efficiency of the wards, thereby allowing the nursing staff to dedicate more time to perform tasks directly involved with patient care. Conflict of interest No conflict of interest
- Open Access
- 16 February 2021
- Published by EDP Sciences
- Vol. 238, 01012
Preliminary assessment of a microgrid integrated with a biomass gasification CHP system for a production facility in Central Italy
The aim to reduce carbon dioxide emissions and to improve buildings energy efficiency has led to develop smart grids to manage electricity and heat. The work deals with the thermal and electric microgrid analysis of the Loccioni Company: the production facility consists of high-energy performance industrial and office buildings, partially powered by produced on-site renewable energy (solar PV, hydropower plants, water ground heat pumps). The challenge of continuous improvement in the use of energy led the company to develop a thermal microgrid for optimal management of the heat produced by a small-scale CHP system (50 kWel/110 kWth). The cogeneration system is based on biomass (pellet) chemical degradation process of gasification. The work discusses preliminary results relating to the first months of the system operation, to highlight the energy benefits and the critical issues. Data are collected by the Company monitoring system and a laboratory feedstock physico-chemical characterization is carried out. The main goal of this paper is to lay the foundations for the development of an energy management system that regulates energy flows between buildings. The development of the thermal microgrid will guarantee not only tangible benefits in terms of energy savings but also an increase in the resilience of the entire building/plant system.
- 16 February 2021
- Published by EDP Sciences
- Vol. 238, 01012
Open AccessPreliminary assessment of a microgrid integrated with a biomass gasification CHP system for a production facility in Central Italy
The aim to reduce carbon dioxide emissions and to improve buildings energy efficiency has led to develop smart grids to manage electricity and heat. The work deals with the thermal and electric microgrid analysis of the Loccioni Company: the production facility consists of high-energy performance industrial and office buildings, partially powered by produced on-site renewable energy (solar PV, hydropower plants, water ground heat pumps). The challenge of continuous improvement in the use of energy led the company to develop a thermal microgrid for optimal management of the heat produced by a small-scale CHP system (50 kWel/110 kWth). The cogeneration system is based on biomass (pellet) chemical degradation process of gasification. The work discusses preliminary results relating to the first months of the system operation, to highlight the energy benefits and the critical issues. Data are collected by the Company monitoring system and a laboratory feedstock physico-chemical characterization is carried out. The main goal of this paper is to lay the foundations for the development of an energy management system that regulates energy flows between buildings. The development of the thermal microgrid will guarantee not only tangible benefits in terms of energy savings but also an increase in the resilience of the entire building/plant system.
- Open Access
- 16 February 2021
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 238, 06004
Energy analysis, numerical simulations and intervention proposals for a NZEB industrial building: the “Loccioni Leaf Lab” case study
The object of this paper is the “Loccioni Leaf Lab”, an industrial nZEB connected to a thermal and electric smart grid. Having nZEB buildings connected to a smart grid offers the possibility of maximizing the benefits that can be obtained by optimal regulation of the grid itself, providing excellent economic and energy results. The case study, which hosts offices and workers operating on test benches, features high performance envelope, solar photovoltaic systems, groundwater heat pumps and a hightechnology control and monitoring system. In order to analyse HVAC-related energy consumptions, the building was modelled using DesignBuilder and EnergyPlus software. The annual dynamic simulations for the assessment of building thermal-energy performance were carried out using available monitored weather data (2019). The model was validated according to ASHRAE guidelines, comparing the outputs of the software with data collected and stored by Company internal database. In the validation process, mean indoor air temperatures of several zones and heating and cooling energy consumptions were considered as key outputs. The validated model has then been used to suggest optimization strategies and to analyse the results obtained with proposed interventions in terms of energy saving.
- 16 February 2021
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 238, 06004
Open AccessEnergy analysis, numerical simulations and intervention proposals for a NZEB industrial building: the “Loccioni Leaf Lab” case study
The object of this paper is the “Loccioni Leaf Lab”, an industrial nZEB connected to a thermal and electric smart grid. Having nZEB buildings connected to a smart grid offers the possibility of maximizing the benefits that can be obtained by optimal regulation of the grid itself, providing excellent economic and energy results. The case study, which hosts offices and workers operating on test benches, features high performance envelope, solar photovoltaic systems, groundwater heat pumps and a hightechnology control and monitoring system. In order to analyse HVAC-related energy consumptions, the building was modelled using DesignBuilder and EnergyPlus software. The annual dynamic simulations for the assessment of building thermal-energy performance were carried out using available monitored weather data (2019). The model was validated according to ASHRAE guidelines, comparing the outputs of the software with data collected and stored by Company internal database. In the validation process, mean indoor air temperatures of several zones and heating and cooling energy consumptions were considered as key outputs. The validated model has then been used to suggest optimization strategies and to analyse the results obtained with proposed interventions in terms of energy saving.
- 10 February 2021
- Published by SAGE Publications in Journal of Oncology Pharmacy Practice
- Vol. 28 (2) , 353-361
Increasing pharmacy productivity and reducing medication turnaround times in an Italian comprehensive cancer center by implementing robotic chemotherapy drugs compounding
Introduction: The management of antineoplastic drugs used for chemotherapy is widely recognized as a high-risk activity. In 2018, our oncology pharmacy implemented workflow improvements to manage the growing workload due to the centralisation of activities from a hospital’s satellite pharmacy, moving towards automated compounding of antineoplastic drugs. The aim of this study was to determine the impact of the centralization on the productivity of the pharmacy department and evaluate the performances of the robotic chemotherapy drugs compounding. Material and methods: Data were collected from the hospital information system and the workflow management software, and examined over a 3-year period (2017–2019). The total annual throughput in terms of doses prepared and patients treated and the Medication Turnaround Time (MTAT) were determined. Productivity and dosage accuracy were calculated for the robotic system. Results: In 2018, the number of patients treated increased by 16.6%, consequently, the overall number of intravenous preparations compounded in the pharmacy increased by 17.2%. Regarding manual compounding, the total number of antineoplastic preparations decreased by about 2%. Investigational treatments manually compounded increased by about 27%, in contrast to the non-investigational treatments, which decreased by 9.4%. Regarding robotic compounding, the annual production increased by 50.4%. In 2018, the MTAT decreased about 24%. The dosage accuracy and precision of the total amount of doses were -1.1% and 1.2%, respectively. Conclusion: This study indicates that in the effort to satisfy an ever-increasing workload, computerization and automation are essential instruments to maintain and ensuring high standards of quality.
- 10 February 2021
- Published by SAGE Publications in Journal of Oncology Pharmacy Practice
- Vol. 28 (2) , 353-361
Increasing pharmacy productivity and reducing medication turnaround times in an Italian comprehensive cancer center by implementing robotic chemotherapy drugs compounding
Introduction: The management of antineoplastic drugs used for chemotherapy is widely recognized as a high-risk activity. In 2018, our oncology pharmacy implemented workflow improvements to manage the growing workload due to the centralisation of activities from a hospital’s satellite pharmacy, moving towards automated compounding of antineoplastic drugs. The aim of this study was to determine the impact of the centralization on the productivity of the pharmacy department and evaluate the performances of the robotic chemotherapy drugs compounding. Material and methods: Data were collected from the hospital information system and the workflow management software, and examined over a 3-year period (2017–2019). The total annual throughput in terms of doses prepared and patients treated and the Medication Turnaround Time (MTAT) were determined. Productivity and dosage accuracy were calculated for the robotic system. Results: In 2018, the number of patients treated increased by 16.6%, consequently, the overall number of intravenous preparations compounded in the pharmacy increased by 17.2%. Regarding manual compounding, the total number of antineoplastic preparations decreased by about 2%. Investigational treatments manually compounded increased by about 27%, in contrast to the non-investigational treatments, which decreased by 9.4%. Regarding robotic compounding, the annual production increased by 50.4%. In 2018, the MTAT decreased about 24%. The dosage accuracy and precision of the total amount of doses were -1.1% and 1.2%, respectively. Conclusion: This study indicates that in the effort to satisfy an ever-increasing workload, computerization and automation are essential instruments to maintain and ensuring high standards of quality.
- 12 October 2020
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 111 (7-8) , 1813-1829
Geometrical calibration of a 6-axis robotic arm for high accuracy manufacturing task
- 12 October 2020
- Published by Springer Nature in The International Journal of Advanced Manufacturing Technology
- Vol. 111 (7-8) , 1813-1829
Geometrical calibration of a 6-axis robotic arm for high accuracy manufacturing task