Type
Healthcare
Locations
Charlottesville, United States

Latest Publications

  • Open Access

    SiriusBI: A Comprehensive LLM-Powered Solution for Data Analytics in Business Intelligence

    by Jie Jiang, Haining Xie, Siqi Shen, Yu Shen, Zihan Zhang, Meng Lei, Yifeng Zheng, Yang Li, Chunyou Li, Danqing Huang, et al.

    With the proliferation of Large Language Models (LLMs) in Business Intelligence (BI), existing solutions face critical challenges in industrial deployments: functionality deficiencies from legacy systems failing to meet evolving LLM-era user demands, interaction limitations from single-round SQL generation paradigms inadequate for multi-round clarification, and cost for domain adaptation arising from cross-domain methods migration. We present SiriusBI, a practical LLM-powered BI system addressing the challenges of industrial deployments through three key innovations: (a) An end-to-end architecture integrating multi-module coordination to overcome functionality gaps in legacy systems; (b) A multi-round dialogue with querying mechanism, consisting of semantic completion, knowledge-guided clarification, and proactive querying processes, to resolve interaction constraints in SQL generation; (c) A data-conditioned SQL generation method selection strategy that supports both an efficient one-step Fine-Tuning approach and a two-step method leveraging Semantic Intermediate Representation for low-cost cross-domain applications. Experiments on both real-world datasets and public benchmarks demonstrate the effectiveness of SiriusBI. User studies further confirm that SiriusBI enhances both productivity and user experience. As an independent service on Tencent's data platform, SiriusBI is deployed across finance, advertising, and cloud sectors, serving dozens of enterprise clients. It achieves over 93% accuracy in SQL generation and reduces data analysts' query time from minutes to seconds in real-world applications.


  • Open Access

    Odor-Cued Grab Air Sampling for Improved Investigative Odorant Prioritization Assessment of Transient Downwind Environmental Odor Events

    by Donald W. Wright, Jacek A. Koziel, Fred W. Kuhrt, Anna Iwasinska, David K. Eaton, Landon Wahe

    A critical prelude to any community odor assessment should be the prioritization of specific chemical odorants that are most responsible for targeted downwind odors. Unfortunately, and historically, this is a step that has often been bypassed or overlooked. However, correct understanding of the specific impactful volatile organic compounds (VOCs) can inform the follow-on sampling, analytical, and remediation strategies that are most appropriate and efficient, based upon the chemistry behind the issue. With this understanding, the techniques and sampling strategies presented herein should be viewed as a qualitative prelude rather than an addendum to a follow-up routine, automated downwind odor monitoring. Downwind odor characteristics can vary depending upon the size of the upwind source, interim topography, and wind conditions. At one extreme, the downwind odor plume from a relatively large source located on a flat open plain and under stable, near-straight line wind conditions can be rather broad, sustained, and predictable. In contrast, the plume from a small point source (e.g., a roof vent stack) located on irregular topography and under rapidly shifting wind conditions can be intermittent and fleeting ("spikes" or "bursts"). These transient odor events can be surprisingly intense and offensive, despite their fleeting occurrence and perception. This work reports on improving and optimizing an environmental sampling strategy for odorant prioritization from such transient downwind odor conditions. This optimization addresses the challenges of (1) sampling of transient odor "spikes" and (2) prioritizing odors/odorants from multiple, closely colocated point sources under transient event conditions. Prioritizing is defined as identifying the key impactful odorants downwind. Grab air sampling protocol refinement has emerged from actual community environmental odor assessment projects. The challenge of assessing transient odor events has been mitigated by utilizing (a) rapid, odor-cued whole-air grab sampling (i.e., activated by and synchronous with the perceived sensory spikes) into metalized fluorinated ethylene polymer (m-FEP) gas sampling bags; (b) immediate transfer from bags onto solid-phase microextraction (SPME) fibers or sorbent tubes; and (c) maintaining refrigerated storage and shipment conditions between field collection and in-laboratory analysis. Results demonstrated approximately 11-fold increases in target odorant yields for 900 mL air sample capture on sorbent tube transfers from 2 to 3 s "burst" odor event bag captures compared to equivalent direct collections (with sorbent tubes) at the same downwind receptor location but during perceived (stable) odor "lull" periods. An application targeting general odor sampling and point-source differentiation utilizing tracer gases is also presented.


  • MFIX: An Efficient and Reliable Index Advisor via Multi-Fidelity Bayesian Optimization

    by Zhuo Chang, Xinyi Zhang, Yang Li, Xupeng Miao, Yanzhao Qin, Bin Cui

    Indexes play a pivotal role in enhancing database performance. However, index selection remains one of the most challenging problems in relational database management systems, as it demands a careful equilibrium: the search procedure needs to efficiently navigate through a multitude of potential configu-rations, while the evaluation method needs to precisely assess the performance impact of index configurations. Specifically, prohibitively high costs can arise from frequent index creation and workload execution for evaluation, whereas over-reliance on cost estimations can yield suboptimal performance due to potential inaccuracies. In this paper, we present a multi-fidelity index advisor, MFIX, designed to reconcile search efficiency and solution quality. To balance evaluation accuracy and efficiency, MFIX coordinates a range of low-fidelity cost estimates as cheap-to-evaluate ap-proximations, with a select few precise high-fidelity workload executions for refinement. To optimize search efficiency, MFIX employs a data-efficient Bayesian optimization method, paired with a condensed tree-structured index space that eliminates redundant configurations. Furthermore, MFIX incorporates his-torical tasks as auxiliary information with variable fidelity, using an adaptive weighting mechanism that considers task similarity to expedite the search process. Extensive experiments with diverse analytical workloads show that MFIX consistently out-performs state-of-the-art single-fidelity methods, achieving up to a 10.2% increase in performance improvement in actual execution cost over the leading estimation-based approach. Furthermore, through its multi-fidelity Bayesian optimization over conditional space, MFIX significantly enhances the search efficiency and ensures a sustainable search cost.


  • Open Access

    Layer-by-Layer Delivery of Multiple Antigens Using Trimethyl Chitosan Nanoparticles as a Malaria Vaccine Candidate

    by Yang Xu, Ziyou Zhou, Brad Brooks, Tammy Ferguson, Judy Obliosca, Jing Huang, Izumi Kaneko, Shiroh Iwanaga, Masao Yuda, Yukiko Tsuji, et al.

    Developing a safe and effective malaria vaccine is critical to reducing the spread and resurgence of this deadly disease, especially in children. In recent years, vaccine technology has seen expanded development of subunit protein, peptide, and nucleic acid vaccines. This is due to their inherent safety, the ability to tailor their immune response, simple storage requirements, easier production, and lower expense compared to using attenuated and inactivated organism-based approaches. However, these new vaccine technologies generally have low efficacy. Subunit vaccines, due to their weak immunogenicity, often necessitate advanced delivery vectors and/or the use of adjuvants. A new area of vaccine development involves design of synthetic micro- and nano-particles and adjuvants that can stimulate immune cells directly through their physical and chemical properties. Further, the unique and complex life cycle of the Plasmodium organism, with multiple stages and varying epitopes/antigens presented by the parasite, is another challenge for malaria vaccine development. Targeting multistage antigens simultaneously is therefore critical for an effective malaria vaccine. Here, we rationally design a layer-by-layer (LbL) antigen delivery platform (we called LbL NP) specifically engineered for malaria vaccines. A biocompatible modified chitosan nanoparticle (trimethyl chitosan, TMC) was synthesized and utilized for LbL loading and release of multiple malaria antigens from pre-erythrocytic and erythrocytic stages. LbL NP served as antigen/protein delivery vehicles and were demonstrated to induce the highest Plasmodium falciparum Circumsporozoite Protein (PfCSP) specific T-cell responses in mice studies as compared to multiple controls. From immunogenicity studies, it was concluded that two doses of intramuscular injection with a longer interval (4 weeks) than traditional malaria vaccine candidate dosing would be the vaccination potential for LbL NP vaccine candidates. Furthermore, in PfCSP/Py parasite challenge studies we demonstrated protective efficacy using LbL NP. These LbL NP provided a significant adjuvant effect since they may induce innate immune response that led to a potent adaptive immunity to mediate non-specific anti-malarial effect. Most importantly, the delivery of CSP full-length protein stimulated long-lasting protective immune responses even after the booster immunization 4 weeks later in mice.


  • In Silico Examination of Initiation of Long-Acting Insulin Analogs Toujeo Compared to Lantus Under 3 Dosing Titration Rules in Virtual Type 2 Diabetes Subjects

    by Jochen Sieber, Mark Weinheimer, Gail Kongable, Susan Riddle, Yung-Yeh Chang, Frank Flacke

    Background: Despite the benefits and clinical necessity of insulin treatment in type 2 diabetes (T2D), healthcare providers are reluctant to initiate insulin, and patients are reluctant to start it for several reasons, one of these being the complexity of insulin treatment. Patients and their healthcare providers can benefit from titration algorithms (TAs) or rules that assist with the initiation and titration of insulin, performing the calculations that are needed to safely initiate and conservatively adjust. Methods: The primary objective for this in silico study was to examine the effectiveness of 3 dose TAs (1-3) for optimization of basal insulin glargine (Gla-100 and Gla-300). In the simulations, 100 virtual subjects with T2D were included (50% men, age 62 ± 3 years, HbA1c 8.1% ± 2.9%, body weight 94 ± 16 kg). Subjects were studied under each TA (TA1 and TA2 fasting blood glucose [FBG] targets 90-130 mg/dL, TA3 FBG target 110-150 mg/dL). Initial dose of both insulins was based on 0.2 U/kg body weight. During 3 months, subjects reported their FBG to the LTHome web-based dose guidance system with a rules engine to safely guide long-acting insulin titration and maintenance. Subjects followed dose recommendations to reach designated FBG target ranges. Results: All subjects reached stable doses under all TAs with both Gla-100 and Gla-300 insulin, and 93 or more of the 100 subjects, depending on the assigned TA, achieved the target FBG range within the 3-month simulation for all TAs. Mean FBG was lowered (Gla-100: 155 ± 40 to 118 ± 11 mg/dL with TA1 and TA2 and 132 ± 12 mg/dL for TA3; Gla-300: 125 ± 14 with TA1 and TA2 and 134 ± 15 mg/dL with TA3). Calculated HbA1c improved from 8.1% ± 2.9% to 7.1% ± 2.5% for TA1 and TA2 and 7.5% ± 2.5% for TA3, a reduction of 0.9% and 0.6% over 3 months for both insulins. Three subjects on Gla-100 and one subject on Gla-300 experienced mild hypoglycemia. Conclusion: All TAs delivered safe dose recommendations with minimal hypoglycemia, leading to a stable glucose control in the majority of subjects.


  • Open Access

    362 Dockworkers musculoskeletal injury prevention program on a brazilian terminal

    by Eb Lima, Jm Almeida, As Alves, Ma Pinto, Ff Santos

    Introduction Terminals in the port of Santos, the largest in Latin America, are constantly working to minimise physical impacts of work on employees. Aiming at the prevention of musculoskeletal injuries and quality of life improvement, we implemented a series of functional and ergonomic measures in 2014, which resulted in significant absenteeism reduction and excellent acceptance from employees, with a relevant improvement to their quality of life. Methods The program begins with a health evaluation on the employee’s admission that includes anthropometry, dynamometry and surface electromyography. On the first month of work, the employee’s last 40 min of the workday are held in a gym inside the terminal, where specific exercises, conducted by 3 physical educators professionals. After this period this routine becomes optional, but with a strong incentive for its continuity (outside of the work period). Also, there is a daily labour gymnastics program maintained for all employees. Concomitantly, research is done on ergonomic conditions, where employees give opinions about job satisfaction and possible adverse conditions, suggesting actions that will be evaluated by the Ergonomics Committee that study and treat these cases. Result Since 2015, when the program started, if compared to 2014, there was a 30% reduction of absenteism caused by osteo-muscular injuries. From 2015 to 2016 there was a 46% absenteism reduction from the same causes. When comparing 2014 with 2016, there was an overall reduction of 62%. Additionally, in 2016, 132 employees suggestions on ergonomic aspects were raised and addressed by the Ergonomics Committee. A relevant index show that 78% of the employees were practicing some physical activity by the end of 2016 and of those, 48% performed the activities inside the Terminal’s gym. Discussion Musculoskeletal injuries are the major causes of dockworkers absenteeism. The Program implementation and employees suggestions significantly reduced absenteeism reates, encouraged the physical activities practice in the workplace and consequently improved their quality of life.


  • Monitoring During Lateral Bridge Slide

    by Ozan Ridvanoglu, Upul Attanayake, Haluk Aktan

    Slide-in bridge construction (SIBC) is an accelerated bridge construction method. In U.S. state of the art and state of the practice today, the bridge superstructure is moved by sliding laterally into the final alignment following a sequence of construction and demolition events. SIBC implementation components require a temporary support structure, a slide system with railing girders and polytetrafluoroethylene pads or rollers, and an actuating system to initiate and maintain the slide movement. The M-100 bridge over the Canadian National (CN) railway was the third SIBC project implemented by the Michigan Department of Transportation. Each SIBC implementation has been so far unique because the unknowns include slide properties contributing to friction between surfaces, pushing and pulling force levels, and monitoring and controlling the force levels. The purpose of standardization is to develop repeatable procedures for the SIBC method. One aspect of standardization is to develop an understanding of the structural response and the forces developed in the system during slide activities. This understanding requires documentation of various SIBC practices, simulation of slide activities, and monitoring the structural response. The activities of the M-100 road over the CN railway bridge slide, instrumentation and monitoring of the structural response, and the use of acquired acceleration data to calculate the forces that developed during the slide activities are presented.


  • Analysis of the Accuracy and Performance of a Continuous Glucose Monitoring Sensor Prototype: An In-Silico Study Using the UVA/PADOVA Type 1 Diabetes Simulator

    by Marc D. Breton, Rolf Hinzmann, Enrique Campos-Nañez, Susan Riddle, Michael Schoemaker, Guenther Schmelzeisen-Redeker

    Computer simulation has been shown over the past decade to be a powerful tool to study the impact of medical devices characteristics on clinical outcomes. Specifically, in type 1 diabetes (T1D), computer simulation platforms have all but replaced preclinical studies and are commonly used to study the impact of measurement errors on glycemia. We use complex mathematical models to represent the characteristics of 3 continuous glucose monitoring systems using previously acquired data. Leveraging these models within the framework of the UVa/Padova T1D simulator, we study the impact of CGM errors in 6 simulation scenarios designed to generate a wide variety of glycemic conditions. Assessment of the simulated accuracy of each different CGM systems is performed using mean absolute relative deviation (MARD) and precision absolute relative deviation (PARD). We also quantify the capacity of each system to detect hypoglycemic events. The simulated Roche CGM sensor prototype (RCGM) outperformed the 2 alternate systems (CGM-1 & CGM-2) in accuracy (MARD = 8% vs 11.4% vs 18%) and precision (PARD = 6.4% vs 9.4% vs 14.1%). These results held for all studied glucose and rate of change ranges. Moreover, it detected more than 90% of hypoglycemia, with a mean time lag less than 4 minutes (CGM-1: 86%/15 min, CGM-2: 57%/24 min). The RCGM system model led to strong performances in these simulation studies, with higher accuracy and precision than alternate systems. Its characteristics placed it firmly as a strong candidate for CGM based therapy, and should be confirmed in large clinical studies.


  • Gallium-containing mesoporous bioactive glass with potent hemostatic activity and antibacterial efficacy

    by Sara Pourshahrestani, Ehsan Zeimaran, Nahrizul Adib Kadri, Nicola Gargiulo, Shani Samuel, Sangeetha Vasudevaraj Naveen, Tunku Kamarul, Mark R. Towler

    Haemorrhage remains the leading cause of potentially survivable death in both military and civilian populations. Although a large variety of hemostatic agents have been developed, many of them have an inadequate capacity to induce hemostasis and are not effective in killing bacteria. In recent years, mesoporous bioactive glasses (MBGs) were found to be effective in inducing hemostasis. However, the materials may not be considered as ideal hemostats since they do not offer antimicrobial activity. The gallium ion (Ga+3) not only exhibits antibacterial properties but also accelerates the blood coagulation cascade. The aim of this study was to develop MBGs containing various concentrations of Ga2O3 (1, 2 & 3 mol%) via the evaporation-induced self-assembly (EISA) process and investigate whether the addition of Ga3+ would induce both hemostatic and antibacterial effects. The results indicated that the incorporation of lower Ga2O3 content (1 mol%) into the MBG system improved structural properties including the specific surface area, mesopore size and pore volume as well as the release of silicon and calcium ions. The bioactive glass was found to stimulate blood coagulation, platelet adhesion and thrombus generation and exerted an antibacterial effect against both Escherichia coli and Staphylococcus aureus. Likewise, Ga-doped MBGs showed excellent cytocompatibility even after 3 days, with the 1% Ga2O3-containing MBG attaining the best biocompatibility that render them safe hemostatic agents for stopping bleeding. This study demonstrated that the lowest Ga2O3-substituted MBG can be a potent candidate for controlling haemorrhage and wound infection.