Type
Company
Locations
Teaneck, United States
Relationships
Parent Organizations

Latest Publications

  • At-line analysis of antisense oligonucleotide purified fractions using fast chromatographic methods

    by Ahmed Elmekawy, Laura J Hayward, Masafumi Iwamoto, Jun Matsunami, Farzin Gharahdaghi

  • Experiences from the Use of Thinner SRU Membranes on Existing Offshore Platforms

    by R. Garrote, R. Hepp, J. Banham, X. Huang

    New thinner SRU (Sulfate Removal Unit) NF (Nano Filtration) membrane was developed to boost the more efficient available water productivity per treatment module for energy and space saving benefits. Two module designs have been offered to the offshore service, with one targeting a more efficient fouling control with expanded surface area, and another targeting utmost compact design to save energy and space consumption. This new technology is currently available and has been used at offshore fields since 2020. With the replacement of the new NF membranes, existing SRUs can either increase by 10 to 16% capacity without modifying the actual system or use a thicker feed spacer (34 mil vs. 26 mil), allowing for operation at lower Differential Pressures (dP) reducing Cleaning-In-Place (CIP) frequency and alleviating the hassle and downtime stress brought by fouling management. New systems can be designed with 9.1-13.7% reduction in size for the same capacity when compared to standard SRU membranes. This paper investigates the benefits achieved in the real field on thinner NF membrane installation through the analysis of fouling control, production capacity boosts and membrane longevity extension. Existing platforms where the thinner SRU membranes are in use side by side with regular membrane product were tracked for direct comparison, which reveals remarkable gaining on energy consumption, chemical reduction, and downtime control with new thinner membrane installation.


  • Reducing Weight, Footprint, and Capital Cost of Sulphate Removal Units Using Modified Membranes

    by R. Garrote, J. Banham, M. Neculau, R. Hepp, E. Chaumien

    Membrane suppliers manufacture RO (Reverse Osmosis) and NF (Nano Filtration) in spiral wound elements, being 8" the most common element size. The spiral wound element was developed in 1970 to package RO and NF material into compact, efficient, and usable unit. Over the last decades, optimization of the manufacturing processes such as robotic glue lines and automated rolling of the elements, provided incremental improvements in the ability to pack more active membrane area in the same limited available volume defined by the length and diameter of the 8" element; but as the technology became mature, the room for further packing improvements vanished and spiral element configuration has reached an optimal plateau. Available membranes in the market have mainly been optimized up to two standard offerings: a) the higher surface of 440 ft2 per element using thinner feed spacer of 26-mil, or b) the thicker feed spacer of 34-mil having 400 ft2 per element. System designers decide on either of the optimizations depending on the feedwater and pretreatment quality, being the high surface of 440 ft2 elements reserved for "good" feedwaters. This optimal plateau drove the market at least over the last decade where all new models launched offer improvements in either rejection, permeability, fouling resistant or robustness. However, all these new products have not varied in packing density that remained unchanged. Thanks to innovation in materials science, a new generation of RO and NF elements has been developed using unique New Thin-membrane technology. This unique technology allows for significative improvement in the packing density, offering the possibility of taking advantage of the combination of both forementioned optimizations in the same membrane element, that is the high active surface area of 440 ft2 and the 34-mil feed spacer. Alternatively, the technology allows to keep the thinner 26-mil feed spacer but boosting the active membrane area up to 510 ft2 per membrane element. This new technology has already been marketed and since 2020, several systems have been in service with the new generation elements. In this paper we discuss the advantages of using the new generation elements as experienced in the replacement of older generation elements used for Sulphate Removal in FPSOs in Brazil and other regions.


  • Development and first evaluation of an attractant impregnated adhesive tape against blood‐sucking flies

    by Junwei J. Zhu, Gwang‐Hyun Roh, Yosuke Asamoto, Kujtim Bizati, Jen‐Chieh Liu, Alexander Lehmann, Kyle Harrison, David B. Taylor, Hironao Otake

    Stable flies are one of the most important arthropod pests of livestock that reduce cattle weight gain and milk production leading to annual economic losses in excess of $2 billion to the US cattle industry. The host-seeking behavior is primarily mediated by associated odors from stable fly larval development environments and host animals. The present paper reports the development and evaluation of attractant-impregnated adhesive tapes to reduce stable fly attacks on cattle. Laboratory bioassays showed that only m-cresol impregnated adhesive tapes caught significantly more stable flies (16 +/- 1) than the control tape without attractant added (7 +/- 1), with a 77% fly recapture rate. Attractant-impregnated adhesive tapes deployed in cattle feedlots showed significant impacts in reducing fly population, with a total of one million stable flies captured over a period of three weeks (mean catches from 57 596 to 102 088 stable flies per trap per week). It further relieved cattle stress with a significant reduction of biting fly avoidance behavior, (6 +/- 0.4 cows observed with tail wagging in control vs. 3 +/- 0.4 from the trap-deployed). The efficacy of the developed tapes lasted up to 1-week longevity, although 70% of m-cresol was released starting from the second day. The m-cresol impregnated adhesive tape provided an 80% reduction in cattle stress due to stable fly attack. This is the first report of a technology developed by integrating an attractant compound into an adhesive material on a plastic film with demonstrated effectiveness in trapping biting flies that attack livestock animals.


  • De Novo Design of Skin‐Penetrating Peptides for Enhanced Transdermal Delivery of Peptide Drugs

    by Stefano Menegatti, Michael Zakrewsky, Sunny Kumar, Joshua Sanchez De Oliveira, John A. Muraski, Samir Mitragotri

    Skin‐penetrating peptides (SPPs) are attracting increasing attention as a non‐invasive strategy for transdermal delivery of therapeutics. The identification of SPP sequences, however, currently performed by experimental screening of peptide libraries, is very laborious. Recent studies have shown that, to be effective enhancers, SPPs must possess affinity for both skin keratin and the drug of interest. We therefore developed a computational process for generating and screening virtual libraries of disulfide‐cyclic peptides against keratin and cyclosporine A (CsA) to identify SPPs capable of enhancing transdermal CsA delivery. The selected sequences were experimentally tested and found to bind both CsA and keratin, as determined by mass spectrometry and affinity chromatography, and enhance transdermal permeation of CsA. Four heptameric sequences that emerged as leading candidates (ACSATLQHSCG, ACSLTVNWNCG, ACTSTGRNACG, and ACSASTNHNCG) were tested and yielded CsA permeation on par with previously identified SPP SPACE TM. An octameric peptide (ACNAHQARSTCG) yielded significantly higher delivery of CsA compared to heptameric SPPs. The safety profile of the selected sequences was also validated by incubation with skin keratinocytes. This method thus represents an effective procedure for the de novo design of skin‐penetrating peptides for the delivery of desired therapeutic or cosmetic agents.


  • Organic light emitting diode improves diabetic cutaneous wound healing in rats

    by Xingjia Wu, Stephanie Alberico, Edward Saidu, Sazzadur Rahman Khan, Shijun Zheng, Rebecca Romero, Hyun Sik Chae, Sheng Li, Amane Mochizuki, Juanita Anders

    A major complication for diabetic patients is chronic wounds due to impaired wound healing. It is well documented that visible red wavelengths can accelerate wound healing in diabetic animal models and patients. In vitro and in vivo diabetic models were used to investigate the effects of organic light emitting diode (OLED) irradiation on cellular function and cutaneous wound healing. Human dermal fibroblasts were cultured in hyperglycemic medium (glucose concentration 180 mM) and irradiated with an OLED (623 nm wavelength peak, range from 560 to 770 nm, power density 7 or 10 mW/cm2 at 0.2, 1, or 5 J/cm2). The OLED significantly increased total adenosine triphosphate concentration, metabolic activity, and cell proliferation compared with untreated controls in most parameters tested. For the in vivo experiment, OLED and laser (635 ± 5 nm wavelength) treatments (10 mW/cm2, 5 J/cm2 daily for a total of seven consecutive days) for cutaneous wound healing were compared using a genetic, diabetic rat model. Both treatments had significantly higher percentage of wound closure on day 6 postinjury and higher total histological scores on day 13 postinjury compared with control. No statistical difference was found between the two treatments. OLED irradiation significantly increased fibroblast growth factor‐2 expression at 36‐hour postinjury and enhanced macrophage activation during initial stages of wound healing. In conclusion, the OLED and laser had comparative effects on enhancing diabetic wound healing.


  • Impact of Ga/(In + Ga) profile in Cu(In,Ga)Se2 prepared by multi-layer precursor method on its cell performance

    by Jakapan Chantana, Masashi Murata, Takashi Higuchi, Taichi Watanabe, Seiki Teraji, Kazunori Kawamura, Takashi Minemoto


  • Multi layer precursor method for Cu(In,Ga)Se2 solar cells fabricated on flexible substrates

    by Jakapan Chantana, Taichi Watanabe, Seiki Teraji, Kazunori Kawamura, Takashi Minemoto

    Cu(In,Ga)Se2 (CIGS) solar cells are deemed one of the highest conversion efficiency thin-film solar cells, and the utilization of flexible (stainless steel; SUS) substrates offers several advantages in terms of lowering manufacturing costs. In this work, CIGS films on SUS substrates are deposited by the so-called “multi layer precursor method” using multi layer co-evaporation of material sources. The examination concentrates on the influence of growth temperature and Ga/III, Ga/(In + Ga), profiles of CIGS layers on the cell performance. According to the results, CIGS crystallization is primarily manipulated by growth temperature. Ultimately, the deposition of CIGS on a flexible SUS substrate can be readily controlled to obtain a suitable double Ga/III-grading profile with large grains of CIGS for a high cell efficiency of 16.05%.


  • Open Access

    Development of a simultaneous measurement system for SAXS–WAXD and the thickness of coating films during film formation by solvent evaporation

    by Keisuke Shimokita, Tsukasa Miyazaki, Hiroki Ogawa, Katsuhiro Yamamoto

    A system for the simultaneous measurement of small-angle X-ray scattering and wide-angle X-ray diffraction (SAXS–WAXD) and the thickness of a coating film, obtained with an automatic coater, during film formation has been developed. The system was installed on beamline BL03XU at SPring-8. As model specimens, poly(methyl methacrylate)-b-poly(n-butyl acrylate)-b-poly(methyl methacrylate) (PMMA-b-PnBA-b-PMMA) triblock copolymers with different compositions were used to investigate the film formation process during solvent evaporation. First of all, the data correction methods were examined for the coating films during solvent evaporation. Since the scattering invariant was affected by the scattering volume and the absorption of X-rays by the solvent and the copolymer during drying, the scattering invariant should be corrected for the film width and the X-ray absorption of the sample. The polymer concentration was estimated from the thickness of the coating film during solvent evaporation, while the X-ray absorption was evaluated by using the X-ray linear absorption coefficients of the solvent and the copolymer. The results showed that the correction of the scattering invariant is crucial for an exact description of the film formation process during solvent evaporation.