BVT Technologies (Czechia)
Type
CompanyLocations
Brno, Czech RepublicLatest Publications
- 1 February 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (2) , 027519
Perspective—Thick Film Technology
Thick Film Technology (TFT) offers a new platform for analytical procedures in Electrochemistry. The most routine technology is screen printing. However, it can introduce new procedures connected with miniaturisation or combination of microfluidic and electrodes. TFT use in electrochemistry is discussed. Examples of different sensors are demonstrated. Details are referred to in the original literature. Advanced applications combining TFT with other technologies are demonstrated (capillary electrophoresis on a chip and a sensor with integrated heating and thermometer). Future of TFT in electrochemistry is discussed, also the drawbacks, connection to production and commercial application are noticed.
- 1 February 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (2) , 027519
Perspective—Thick Film Technology
Thick Film Technology (TFT) offers a new platform for analytical procedures in Electrochemistry. The most routine technology is screen printing. However, it can introduce new procedures connected with miniaturisation or combination of microfluidic and electrodes. TFT use in electrochemistry is discussed. Examples of different sensors are demonstrated. Details are referred to in the original literature. Advanced applications combining TFT with other technologies are demonstrated (capillary electrophoresis on a chip and a sensor with integrated heating and thermometer). Future of TFT in electrochemistry is discussed, also the drawbacks, connection to production and commercial application are noticed.
- 14 January 2022
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 414 (10) , 3165-3175
Microdialysis techniques and microdialysis-based patient-near diagnostics
This article will debate the usefulness of POCT measurements and the contribution microdialysis can make to generating valuable information. A particular theme will be the rarely considered difference between ex vivo sampling, which typically generates only a static measure of concentration, and in vivo measurements that are subject to dynamic changes due to mass transfer. Those dynamic changes provide information about the patients’ physiological state.
- 14 January 2022
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 414 (10) , 3165-3175
Microdialysis techniques and microdialysis-based patient-near diagnostics
This article will debate the usefulness of POCT measurements and the contribution microdialysis can make to generating valuable information. A particular theme will be the rarely considered difference between ex vivo sampling, which typically generates only a static measure of concentration, and in vivo measurements that are subject to dynamic changes due to mass transfer. Those dynamic changes provide information about the patients’ physiological state.
- 1 October 2017
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 266, 308-313
The measurement of small flow
- 1 October 2017
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 266, 308-313
The measurement of small flow
- 6 July 2016
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 32 (28) , 7070-7078
Mixed Zwitterion-Based Self-Assembled Monolayer Interface for Impedimetric Glycomic Analyses of Human IgG Samples in an Array Format
An impedimetric lectin biosensor for the detection of changes in the glycan structure of antibodies isolated from human serum is here correlated with the progression of rheumatoid arthritis (RA). The biosensor was built up from a mixed self-assembled monolayer (SAM) on gold consisting of two different thiolated zwitterionic derivatives, carboxybetaine and sulfobetaine, to resist nonspecific interactions. The carboxyl-terminated one was applied also for the covalent immobilization of lectin Ricinus communis agglutinin I (RCA-I). The process of building a bioreceptive layer was optimized and characterized using a diverse range of techniques. Impedimetric assays were integrated on a chip consisting of eight gold working electrodes, which is an important step toward the achievement of a moderate level of multiplexing for the analysis of human serum samples. At the end, the results obtained by the impedimetric analysis of immunoglobulins G (IgGs) isolated from serum samples were compared with those of two other standard bioanalytical methods employing lectins, that is, lectin microarrays (MAs) and enzyme-linked lectin binding assays (ELLBAs). The impedimetric results agreed very well with the DAS28 index (RA disease activity score 28), suggesting that impedimetric assays could be used for the development of a new diagnostic procedure sensitive to glycosylation changes in human IgGs and thus RA progression.
- 6 July 2016
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 32 (28) , 7070-7078
Mixed Zwitterion-Based Self-Assembled Monolayer Interface for Impedimetric Glycomic Analyses of Human IgG Samples in an Array Format
An impedimetric lectin biosensor for the detection of changes in the glycan structure of antibodies isolated from human serum is here correlated with the progression of rheumatoid arthritis (RA). The biosensor was built up from a mixed self-assembled monolayer (SAM) on gold consisting of two different thiolated zwitterionic derivatives, carboxybetaine and sulfobetaine, to resist nonspecific interactions. The carboxyl-terminated one was applied also for the covalent immobilization of lectin Ricinus communis agglutinin I (RCA-I). The process of building a bioreceptive layer was optimized and characterized using a diverse range of techniques. Impedimetric assays were integrated on a chip consisting of eight gold working electrodes, which is an important step toward the achievement of a moderate level of multiplexing for the analysis of human serum samples. At the end, the results obtained by the impedimetric analysis of immunoglobulins G (IgGs) isolated from serum samples were compared with those of two other standard bioanalytical methods employing lectins, that is, lectin microarrays (MAs) and enzyme-linked lectin binding assays (ELLBAs). The impedimetric results agreed very well with the DAS28 index (RA disease activity score 28), suggesting that impedimetric assays could be used for the development of a new diagnostic procedure sensitive to glycosylation changes in human IgGs and thus RA progression.
- Open Access
- 14 November 2014
- Published by Mendel University Press in Acta Universitatis Agriculturae et Silviculturae Mendelianae Brunensis
- Vol. 56 (2) , 73-80
Use of artificial neural networks in biosensor signal classification
Biosensors are analytical devices that transforms chemical information, ranging from the concentration of a specific sample component to total composition analysis, into an analytical signal and that utilizes a biochemical mechanism for the chemical recognition. The complexity of biosensor construction and generation of measured signal requires the development of new method for signal evaluation and its possible defects recognition. A new method based on artificial neural networks (ANN) was developed for recognition of characteristic behavior of signals joined with malfunction of sensor. New algorithm uses unsupervised Kohonen self-organizing neural networks. The work with ANN has two phases – adaptation and prediction. During the adaptation step the classification model is build. Measured data form groups after projection into two-dimensional space based on theirs similarity. After identification of these groups and establishing the connection with signal disorders ANN can be used for evaluation of newly measured signals. This algorithm was successfully applied for 540 signal classification obtained from immobilized acetylcholinesterase biosensor measurement of organophosphate and carbamate pesticides in vegetables, fruits, spices, potatoes and soil samples. From six different signal defects were successfully classified four – low response after substrate addition, equilibration at high values, slow equilibration after substrate addition respectively low sensitivity on syntostigmine.
- 14 November 2014
- Published by Mendel University Press in Acta Universitatis Agriculturae et Silviculturae Mendelianae Brunensis
- Vol. 56 (2) , 73-80
Open AccessUse of artificial neural networks in biosensor signal classification
Biosensors are analytical devices that transforms chemical information, ranging from the concentration of a specific sample component to total composition analysis, into an analytical signal and that utilizes a biochemical mechanism for the chemical recognition. The complexity of biosensor construction and generation of measured signal requires the development of new method for signal evaluation and its possible defects recognition. A new method based on artificial neural networks (ANN) was developed for recognition of characteristic behavior of signals joined with malfunction of sensor. New algorithm uses unsupervised Kohonen self-organizing neural networks. The work with ANN has two phases – adaptation and prediction. During the adaptation step the classification model is build. Measured data form groups after projection into two-dimensional space based on theirs similarity. After identification of these groups and establishing the connection with signal disorders ANN can be used for evaluation of newly measured signals. This algorithm was successfully applied for 540 signal classification obtained from immobilized acetylcholinesterase biosensor measurement of organophosphate and carbamate pesticides in vegetables, fruits, spices, potatoes and soil samples. From six different signal defects were successfully classified four – low response after substrate addition, equilibration at high values, slow equilibration after substrate addition respectively low sensitivity on syntostigmine.
- 24 April 2014
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 161 (6) , B147-B150
Effective Surface Area of Electrochemical Sensors
The article compares the determination of an SPE (Screen Printed Electrodes) electrochemical active surface (AS) by the analysis of cyclic voltammogram in ferro-ferricyanide using Koutecky equation and by confocal and electron microscopy. SPE reliability is influenced by mass transport of analyte to active electrode surface while the physical properties of SPE are reproducible and stable. The electrode reaction involves the upper layer of SPE. The AS is the same as the geometrical area. Other methods set the active/geometrical area relation to 2,03 ± 0,04 (gold working electrode) and 4,35 ± 0,08 (platinum working electrode). It is demonstrated that nanostructures on working electrode surface can be efficient at high frequencies (>10 kHz). The active area of SPE determined by scanning electron microscopy or optical measurement exhibits a standard deviation lower than 2%. It proves SPE be reliable and precise electrochemical device under optimal hydrodynamic conditions.
- 24 April 2014
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 161 (6) , B147-B150
Effective Surface Area of Electrochemical Sensors
The article compares the determination of an SPE (Screen Printed Electrodes) electrochemical active surface (AS) by the analysis of cyclic voltammogram in ferro-ferricyanide using Koutecky equation and by confocal and electron microscopy. SPE reliability is influenced by mass transport of analyte to active electrode surface while the physical properties of SPE are reproducible and stable. The electrode reaction involves the upper layer of SPE. The AS is the same as the geometrical area. Other methods set the active/geometrical area relation to 2,03 ± 0,04 (gold working electrode) and 4,35 ± 0,08 (platinum working electrode). It is demonstrated that nanostructures on working electrode surface can be efficient at high frequencies (>10 kHz). The active area of SPE determined by scanning electron microscopy or optical measurement exhibits a standard deviation lower than 2%. It proves SPE be reliable and precise electrochemical device under optimal hydrodynamic conditions.
- Open Access
- 24 October 2013
- Published by Wiley in Conference Papers in Materials Science
- Vol. 2013, 1-5
A Qualitative Study of Residual Pesticides on Cotton Fibers
Two different methods are utilized for this study. The first method covers the measurement of bioelectrical signals caused by enzymatic inhibition of acetyl cholinesterase (AChE) for the detection of pesticides. Biosensor toxicity analyzer (BTA) was used for the testing and the monitoring of changes in bioelectrical signals caused by the interaction of biological substances, and residues were evaluated. The second method is based on measurement of the oxygen level caused by photosynthetic inhibition of residual pesticides by the interaction with green algae, Scenedesmus (Chlorophyta). Algae growth analyzer (AGA) equipped with miniature sensitive oxygen electrode, a light source and cover to model light and dark phases was used enabling us to follow the lifecycle of algae producing oxygen. The test, conducted under the guideline of faster analogy of DIN 863 toxicity test, alga growth inhibition test (OECD TG 201) was and ISO standard (ISO: 8692). Two samples of cotton were analyzed. Cryogenic homogenization was carried out for sample pretreatment. Soxhlet extraction method (SOX) and ultrasound assisted extraction (USE) were used for extraction. Both methods show reasonable results and can successfully be utilized for the detection of residual pesticides on different types of cotton and especially to compare the classical conventional and organic cotton.
- 24 October 2013
- Published by Wiley in Conference Papers in Materials Science
- Vol. 2013, 1-5
Open AccessA Qualitative Study of Residual Pesticides on Cotton Fibers
Two different methods are utilized for this study. The first method covers the measurement of bioelectrical signals caused by enzymatic inhibition of acetyl cholinesterase (AChE) for the detection of pesticides. Biosensor toxicity analyzer (BTA) was used for the testing and the monitoring of changes in bioelectrical signals caused by the interaction of biological substances, and residues were evaluated. The second method is based on measurement of the oxygen level caused by photosynthetic inhibition of residual pesticides by the interaction with green algae, Scenedesmus (Chlorophyta). Algae growth analyzer (AGA) equipped with miniature sensitive oxygen electrode, a light source and cover to model light and dark phases was used enabling us to follow the lifecycle of algae producing oxygen. The test, conducted under the guideline of faster analogy of DIN 863 toxicity test, alga growth inhibition test (OECD TG 201) was and ISO standard (ISO: 8692). Two samples of cotton were analyzed. Cryogenic homogenization was carried out for sample pretreatment. Soxhlet extraction method (SOX) and ultrasound assisted extraction (USE) were used for extraction. Both methods show reasonable results and can successfully be utilized for the detection of residual pesticides on different types of cotton and especially to compare the classical conventional and organic cotton.
- 1 August 2013
- Published by American Scientific Publishers in Sensor Letters
- Vol. 11 (8) , 1524-1529
Electrochemical Performances of Diamond Like Carbon Films for Pb(II) Detection in Tap Water Using Differential Pulse Anodic Stripping Voltammetry Technique
- 1 August 2013
- Published by American Scientific Publishers in Sensor Letters
- Vol. 11 (8) , 1524-1529
Electrochemical Performances of Diamond Like Carbon Films for Pb(II) Detection in Tap Water Using Differential Pulse Anodic Stripping Voltammetry Technique