Jenoptik (Germany)

Type
CompanyLocations
Jena, GermanyLatest Publications
- 23 September 2025
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13787, 25-124
Cell projection e-beam lithography for optical metastructures
It is widely recognized that Variable Shaped Beam (VSB) lithography is suitable for device prototyping and low volume production in fields like compound semiconductor fabrication, optics and in an increasing number of photonic applications such as photonic integrated circuits, metalenses or photonic crystals. However, the resulting write time for real device manufacturing of optical metastructures and the related costs are often the limiting factor for a wider usage of the technology. Cell Projection (CP), a special exposure mode in Vistec VSB lithography tools, offers the means to overcome these limitations by exposing complex individual shapes in a single exposure shot. In this paper, we focus on the generation and fabrication of an effective-index metastructure for the substitution of thin film anti-reflective (AR) coatings and the layout generation for application specific optical phase profiles e.g. for beam shaping. In this context, CP can be a very useful technology [1], specifically for the efficient exposure of highly repetitive structures on mesoscopic areas necessary for metamaterial applications [2]. To achieve ideal optical phase profiles an optimal combination of the number of exposure cells (in the order of 109) and the design of these cells (in the order of 20 layout variations) are required. Therefore, computer simulations were performed to optimise the metastructure layout (period and diameter of exposure shots) and automated computer-aided design routines were implemented to create application-specific layout files such as lenses or beam shapers.
- 23 September 2025
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13787, 25-124
Cell projection e-beam lithography for optical metastructures
It is widely recognized that Variable Shaped Beam (VSB) lithography is suitable for device prototyping and low volume production in fields like compound semiconductor fabrication, optics and in an increasing number of photonic applications such as photonic integrated circuits, metalenses or photonic crystals. However, the resulting write time for real device manufacturing of optical metastructures and the related costs are often the limiting factor for a wider usage of the technology. Cell Projection (CP), a special exposure mode in Vistec VSB lithography tools, offers the means to overcome these limitations by exposing complex individual shapes in a single exposure shot. In this paper, we focus on the generation and fabrication of an effective-index metastructure for the substitution of thin film anti-reflective (AR) coatings and the layout generation for application specific optical phase profiles e.g. for beam shaping. In this context, CP can be a very useful technology [1], specifically for the efficient exposure of highly repetitive structures on mesoscopic areas necessary for metamaterial applications [2]. To achieve ideal optical phase profiles an optimal combination of the number of exposure cells (in the order of 109) and the design of these cells (in the order of 20 layout variations) are required. Therefore, computer simulations were performed to optimise the metastructure layout (period and diameter of exposure shots) and automated computer-aided design routines were implemented to create application-specific layout files such as lenses or beam shapers.
- 21 March 2025
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13345, 14-87
Next-generation 80x nm high-power diode lasers based on single- and multi-bar packages
We report on recent developments to increase optical output power and reliability of 80x nm high-power diode lasers, significantly exceeding the performance of JENOPTIK’s current 80x nm diode laser generation. The increase in optical output power is mainly achieved via utilization of in-house laser bars with improved chip design. Employing JENOPTIK’s double-side cooled open heat sink designs and its related packaging technology allows for reliable operation of single-bar packages up to 120W optical output power in continuous-wave (cw) operation. For hard-soldered multi-bar packages a novel solder deposition technology has been tested in combination with improved 80x nm broad-area laser bar designs demonstrating pulse peak power levels beyond ~400W per bar in long-pulse (lp) mode operation, i.e. pulse durations up to 10ms and duty cycles on the order of 10%. These promising results spur future developments in the field of optical pumping as well as direct diode laser applications.
- 21 March 2025
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13345, 14-87
Next-generation 80x nm high-power diode lasers based on single- and multi-bar packages
We report on recent developments to increase optical output power and reliability of 80x nm high-power diode lasers, significantly exceeding the performance of JENOPTIK’s current 80x nm diode laser generation. The increase in optical output power is mainly achieved via utilization of in-house laser bars with improved chip design. Employing JENOPTIK’s double-side cooled open heat sink designs and its related packaging technology allows for reliable operation of single-bar packages up to 120W optical output power in continuous-wave (cw) operation. For hard-soldered multi-bar packages a novel solder deposition technology has been tested in combination with improved 80x nm broad-area laser bar designs demonstrating pulse peak power levels beyond ~400W per bar in long-pulse (lp) mode operation, i.e. pulse durations up to 10ms and duty cycles on the order of 10%. These promising results spur future developments in the field of optical pumping as well as direct diode laser applications.
- Open Access
- 24 February 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (5) , 1497
Triangular Screw Placement to Treat Dysmorphic Sacral Fragility Fractures in Osteoporotic Bone Results in an Equivalent Stability to Cement-Augmented Sacroiliac Screws—A Biomechanical Cadaver Study
Background: Sacroiliac screw fixation in elderly patients with pelvic fractures remains a challenging procedure for stabilization due to impaired bone quality. To improve it, we investigated the biomechanical properties of combined oblique sacroiliac and transiliosacral screw stabilization versus the additional cement augmentation of this construct in a cadaver model of osteoporotic bone, specifically with respect to the maximal force stability and fracture-site motion in the displacement and rotation of fragments. Methods: Standardized complete sacral fractures with intact posterior ligaments were created in osteoporotic cadaver pelvises and stabilized with a triangle of two oblique sacroiliac screws from each side with an additional transiliosacral screw in S1 (n = 5) and using the same pelvises with additional cement augmentation (n = 5). A short cyclic loading protocol was applied, increasing the axial force up to 125 N. Sacral fracture-site motion in displacement and rotation of the fragments was measured by optical motion tracking. Results: A maximum force of 65N +/− 12.2 N was achieved using the triangular screw stabilization of the sacrum. Cement augmentation did not provide any significant gain in maximum force (70 N +/− 29.2 N). Only low fragment displacement was observed (2.6 +/− 1.5 mm) and fragment rotation (1.3 +/− 1.2°) without increased stability (3.0 +/− 1.5 mm; p = 0.799; 1.7 +/− 0.4°; p = 0.919) following the cement augmentation. Conclusions: Triangular stabilization using two obliques and an additional transiliosacral screw provides sufficient primary stability of the sacrum. Still, the stability achieved seems very low, considering the forces acting in this area. However, additional cement augmentation did not increase the stability of the sacrum. Given its lack of beneficial abilities, it should be used carefully, due to related complications such as cement leakage or nerve irritation. Improving the surgical methods used to stabilize the posterior pelvic ring will be a topic for future research.
- 24 February 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (5) , 1497
Open AccessTriangular Screw Placement to Treat Dysmorphic Sacral Fragility Fractures in Osteoporotic Bone Results in an Equivalent Stability to Cement-Augmented Sacroiliac Screws—A Biomechanical Cadaver Study
Background: Sacroiliac screw fixation in elderly patients with pelvic fractures remains a challenging procedure for stabilization due to impaired bone quality. To improve it, we investigated the biomechanical properties of combined oblique sacroiliac and transiliosacral screw stabilization versus the additional cement augmentation of this construct in a cadaver model of osteoporotic bone, specifically with respect to the maximal force stability and fracture-site motion in the displacement and rotation of fragments. Methods: Standardized complete sacral fractures with intact posterior ligaments were created in osteoporotic cadaver pelvises and stabilized with a triangle of two oblique sacroiliac screws from each side with an additional transiliosacral screw in S1 (n = 5) and using the same pelvises with additional cement augmentation (n = 5). A short cyclic loading protocol was applied, increasing the axial force up to 125 N. Sacral fracture-site motion in displacement and rotation of the fragments was measured by optical motion tracking. Results: A maximum force of 65N +/− 12.2 N was achieved using the triangular screw stabilization of the sacrum. Cement augmentation did not provide any significant gain in maximum force (70 N +/− 29.2 N). Only low fragment displacement was observed (2.6 +/− 1.5 mm) and fragment rotation (1.3 +/− 1.2°) without increased stability (3.0 +/− 1.5 mm; p = 0.799; 1.7 +/− 0.4°; p = 0.919) following the cement augmentation. Conclusions: Triangular stabilization using two obliques and an additional transiliosacral screw provides sufficient primary stability of the sacrum. Still, the stability achieved seems very low, considering the forces acting in this area. However, additional cement augmentation did not increase the stability of the sacrum. Given its lack of beneficial abilities, it should be used carefully, due to related complications such as cement leakage or nerve irritation. Improving the surgical methods used to stabilize the posterior pelvic ring will be a topic for future research.
- Open Access
- 11 July 2024
- Published by IOP Publishing in Surface Topography: Metrology and Properties
- Vol. 12 (3) , 035008
Intercomparison to validate implementations of different laboratories of algorithms for the analysis of surface texture
The surface texture is an important feature of machine parts for any kind of contact. The quantification of its properties has been a well-established area in quality assurance for many decades. With the increasing demand for precision and interchangeability in the globalised marketplace, the results of surface analysis must be unambiguous and reliable. This is why the International Standardization’s Technical Committee on Geometric Product Specification has updated its standards. Consequently, instrument manufacturers and calibration laboratories need to ensure that their analysis software complies with the new ISO standards. An intercomparison has therefore been carried out to validate surface texture analysis software. Over the past two decades, a number of tests have been conducted on surface texture measurement and analysis methods, including issues of instrument response, discretisation and quantisation. This article examines the numerical and computational aspects of analysis algorithms that process data sets of discrete values of finite floating-point precision as input. The method of testing texture analysis algorithms utilising software measurement standards (softgauges) and the specification of the test tasks are explained. The results of the comparison are presented and discussed.
- 11 July 2024
- Published by IOP Publishing in Surface Topography: Metrology and Properties
- Vol. 12 (3) , 035008
Open AccessIntercomparison to validate implementations of different laboratories of algorithms for the analysis of surface texture
The surface texture is an important feature of machine parts for any kind of contact. The quantification of its properties has been a well-established area in quality assurance for many decades. With the increasing demand for precision and interchangeability in the globalised marketplace, the results of surface analysis must be unambiguous and reliable. This is why the International Standardization’s Technical Committee on Geometric Product Specification has updated its standards. Consequently, instrument manufacturers and calibration laboratories need to ensure that their analysis software complies with the new ISO standards. An intercomparison has therefore been carried out to validate surface texture analysis software. Over the past two decades, a number of tests have been conducted on surface texture measurement and analysis methods, including issues of instrument response, discretisation and quantisation. This article examines the numerical and computational aspects of analysis algorithms that process data sets of discrete values of finite floating-point precision as input. The method of testing texture analysis algorithms utilising software measurement standards (softgauges) and the specification of the test tasks are explained. The results of the comparison are presented and discussed.
- 17 June 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13019, 91-181
A new approach to chromatic variations of Seidel coefficients
For the design of well corrected optical systems with a certain spectral bandwidth, it is often not sufficient to only control axial and lateral color, but also chromatic variations of the fourth order wave aberrations or Seidel coefficients need to be considered. This has already been studied in detail in the literature by Berner. We propose a different approach to calculate the induced surface contributions to chromatic variations of the Seidel coefficients, which is based on the principles of stop and object shift. This offers a different perspective that might be helpful for optical designers. Furthermore, it is demonstrated how this approach generalizes to other cases of tolerance sensitivities of rotationally symmetric systems.
- 17 June 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13019, 91-181
A new approach to chromatic variations of Seidel coefficients
For the design of well corrected optical systems with a certain spectral bandwidth, it is often not sufficient to only control axial and lateral color, but also chromatic variations of the fourth order wave aberrations or Seidel coefficients need to be considered. This has already been studied in detail in the literature by Berner. We propose a different approach to calculate the induced surface contributions to chromatic variations of the Seidel coefficients, which is based on the principles of stop and object shift. This offers a different perspective that might be helpful for optical designers. Furthermore, it is demonstrated how this approach generalizes to other cases of tolerance sensitivities of rotationally symmetric systems.
- 13 March 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12904, 12-17
VCSELs for free space links
We measure the spectral emission and the small-signal modulation frequency response of our 980 nm VCSEL arrays across OM2 multiple-mode optical fiber (MMF) patch cords and for the first time across free space (air) via optical fiber collimators (small focusing triplet lenses with optical fiber connectors) separated by 0.4 m up to 10 m. The VCSELs in our arrays are electrically in parallel but optically uncoupled, with an aim toward mitigating scintillation and speckle loss mechanisms in high bit rate free space data streams. We measure the center (mean) wavelength and the root-mean-square spectral width of our VCSEL arrays as a function of forward bias current, both across MMF and across free space. We find the spectral results are nearly identical within fractions of a nanometer. We similarly measure the S21 (s-parameter) small signal modulation frequency response of our arrays from 0.05 to 40 GHz, across fiber and across free space, and extract and plot the -3 dB bandwidths as functions of forward bias current. We achieve bandwidths up to 25 and 30 GHz for 3-element arrays with 9 and 7 micrometer oxide aperture diameters (Φ), respectively, and find the bandwidths are nearly identical when comparing data transfers across OM2 MMF patch cords versus across the MMF plus a section of free space.
- 13 March 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12904, 12-17
VCSELs for free space links
We measure the spectral emission and the small-signal modulation frequency response of our 980 nm VCSEL arrays across OM2 multiple-mode optical fiber (MMF) patch cords and for the first time across free space (air) via optical fiber collimators (small focusing triplet lenses with optical fiber connectors) separated by 0.4 m up to 10 m. The VCSELs in our arrays are electrically in parallel but optically uncoupled, with an aim toward mitigating scintillation and speckle loss mechanisms in high bit rate free space data streams. We measure the center (mean) wavelength and the root-mean-square spectral width of our VCSEL arrays as a function of forward bias current, both across MMF and across free space. We find the spectral results are nearly identical within fractions of a nanometer. We similarly measure the S21 (s-parameter) small signal modulation frequency response of our arrays from 0.05 to 40 GHz, across fiber and across free space, and extract and plot the -3 dB bandwidths as functions of forward bias current. We achieve bandwidths up to 25 and 30 GHz for 3-element arrays with 9 and 7 micrometer oxide aperture diameters (Φ), respectively, and find the bandwidths are nearly identical when comparing data transfers across OM2 MMF patch cords versus across the MMF plus a section of free space.
- 13 March 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12904, 133-140
Comparison of 980 nm VCSELs with varying monolithic high contrast grating top coupling mirror designs
We design, fabricate, characterize, and compare 980 nm vertical cavity surface emitting lasers (VCSELs) with monolithic high contrast gratings (MHCGs) as top coupling mirrors. The MHCG is a series of parallel, rectangular stripes etched into a uniform GaAs epitaxial surface layer via electron-beam lithography and inductively coupled reactive ion etching, with specific grating period, height, and fill factor (defined as the grating bar width divided by the grating period). To boost the MHCG’s optical power reflectance at 980 nm and the width of the optical stopband we add a 5.5-period p-doped distributed Bragg reflector (DBR) beneath the MHCG grating, thus forming a composite DBR plus MHCG top coupling mirror. The bottom n-doped DBR is a conventional all-semiconductor AlGaAs/GaAs DBR with 37-periods on a GaAs substrate. We fabricate single 980 nm DBR MHCG VCSELs with two oxide aperture diameters on quarter wafer pieces from starting 3- inch diameter VCSEL epitaxial wafers. Each quarter wafer contains six complete unit cells, and each unit cell is a twodimensional array of single VCSELs in 16 rows and 15 columns. We for example set a constant but different grating period in five of the unit cells and vary the grating fill factors from column to column and we vary the oxide aperture diameters from 1 to 9 Pm in the rows, thus yielding a large variety of VCSEL diodes with differing MHCG parameters for us to compare. We perform room temperature on-wafer probe testing of the static optical output power-current-voltage (LIV) characteristics and emission spectra and compare the impact of the grating designs on these test results. We report record static LIV performance for our DBR MHCG VCSELs with threshold current below 1 mA and optical output power exceeding 1.3 mW. We observe room temperature bias current dependent mode emission for example single mode wavelength tuning ranges up to 12 nm.
- 13 March 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12904, 133-140
Comparison of 980 nm VCSELs with varying monolithic high contrast grating top coupling mirror designs
We design, fabricate, characterize, and compare 980 nm vertical cavity surface emitting lasers (VCSELs) with monolithic high contrast gratings (MHCGs) as top coupling mirrors. The MHCG is a series of parallel, rectangular stripes etched into a uniform GaAs epitaxial surface layer via electron-beam lithography and inductively coupled reactive ion etching, with specific grating period, height, and fill factor (defined as the grating bar width divided by the grating period). To boost the MHCG’s optical power reflectance at 980 nm and the width of the optical stopband we add a 5.5-period p-doped distributed Bragg reflector (DBR) beneath the MHCG grating, thus forming a composite DBR plus MHCG top coupling mirror. The bottom n-doped DBR is a conventional all-semiconductor AlGaAs/GaAs DBR with 37-periods on a GaAs substrate. We fabricate single 980 nm DBR MHCG VCSELs with two oxide aperture diameters on quarter wafer pieces from starting 3- inch diameter VCSEL epitaxial wafers. Each quarter wafer contains six complete unit cells, and each unit cell is a twodimensional array of single VCSELs in 16 rows and 15 columns. We for example set a constant but different grating period in five of the unit cells and vary the grating fill factors from column to column and we vary the oxide aperture diameters from 1 to 9 Pm in the rows, thus yielding a large variety of VCSEL diodes with differing MHCG parameters for us to compare. We perform room temperature on-wafer probe testing of the static optical output power-current-voltage (LIV) characteristics and emission spectra and compare the impact of the grating designs on these test results. We report record static LIV performance for our DBR MHCG VCSELs with threshold current below 1 mA and optical output power exceeding 1.3 mW. We observe room temperature bias current dependent mode emission for example single mode wavelength tuning ranges up to 12 nm.
- Open Access
- 7 December 2023
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 10, 1207388
Gender gap–Gender-specific development in the field of obstetrics and gynecology in Germany in the last 20 years
Background: Gender Gap refers to differences between men and women in terms of access to medical education, career development, and leadership positions in medical practice and research. Although women now make up most medical school graduates in many countries, they are often underrepresented in higher positions.Objective: The aim of this study is therefore to analyze the gender-specific development in the field of Obstetrics and Gynecology in Germany over the past 20 years and to survey the current status quo.Materials and methods: An narrative review was carried out on the development of female graduates of human medicine, the proportion of women in contract medical care and clinical care, as well as the gender-specific evaluation of obtaining a gynecological/obstetric additional qualification. habilitation figures in the field of Obstetrics and Gynecology were evaluated about gender distribution. All data were received from federal institutes.Results: A total of 46.7% (n = 95,234) of all inpatient doctors were female. A total of 46.7% (n = 95,234) of the physicians in hospitals were female. A total of 46% (1,832/3,958) were the portion of females as assistant physicians, 39.8% (n = 45.551) as specialists, 35.3% (n = 18789) as senior physicians, 25.1% (n = 2394) as first senior physicians and 25% (n = 10) as chief physicians in hospital. A total of 64.6% (n = 3958) of the physicians in Obstetrics and Gynecology were female. A total of 46% (1,832/3,958) were the portion of females as assistant physicians, 64.6% (n = 3958) as specialists, 65.0% (n = 1919) as senior physicians, 26.4% (n = 207) first senior physicians and 25% (n = 10) as chief physicians in Obstetrics and Gynecology.Discussion: The problem with the gender gap in medicine, does not seem to be access to teaching or starting a residency. But in the functions with increasing responsibility and management functions, e.g., as senior physicians, women are already rarely seen. In Obstetrics and Gynecology, too, there is a shortage of women in leading positions, despite the relatively high numbers, for example as senior physicians. Factors like maternity and establishing a family are points mentioned therefore, but also stereotypes seem to be considerable facts.Conclusion: However, it is important to recognize the need for more women in higher positions in medicine and actively work to encourage more women to choose a career in medicine.
- 7 December 2023
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 10, 1207388
Open AccessGender gap–Gender-specific development in the field of obstetrics and gynecology in Germany in the last 20 years
Background: Gender Gap refers to differences between men and women in terms of access to medical education, career development, and leadership positions in medical practice and research. Although women now make up most medical school graduates in many countries, they are often underrepresented in higher positions.Objective: The aim of this study is therefore to analyze the gender-specific development in the field of Obstetrics and Gynecology in Germany over the past 20 years and to survey the current status quo.Materials and methods: An narrative review was carried out on the development of female graduates of human medicine, the proportion of women in contract medical care and clinical care, as well as the gender-specific evaluation of obtaining a gynecological/obstetric additional qualification. habilitation figures in the field of Obstetrics and Gynecology were evaluated about gender distribution. All data were received from federal institutes.Results: A total of 46.7% (n = 95,234) of all inpatient doctors were female. A total of 46.7% (n = 95,234) of the physicians in hospitals were female. A total of 46% (1,832/3,958) were the portion of females as assistant physicians, 39.8% (n = 45.551) as specialists, 35.3% (n = 18789) as senior physicians, 25.1% (n = 2394) as first senior physicians and 25% (n = 10) as chief physicians in hospital. A total of 64.6% (n = 3958) of the physicians in Obstetrics and Gynecology were female. A total of 46% (1,832/3,958) were the portion of females as assistant physicians, 64.6% (n = 3958) as specialists, 65.0% (n = 1919) as senior physicians, 26.4% (n = 207) first senior physicians and 25% (n = 10) as chief physicians in Obstetrics and Gynecology.Discussion: The problem with the gender gap in medicine, does not seem to be access to teaching or starting a residency. But in the functions with increasing responsibility and management functions, e.g., as senior physicians, women are already rarely seen. In Obstetrics and Gynecology, too, there is a shortage of women in leading positions, despite the relatively high numbers, for example as senior physicians. Factors like maternity and establishing a family are points mentioned therefore, but also stereotypes seem to be considerable facts.Conclusion: However, it is important to recognize the need for more women in higher positions in medicine and actively work to encourage more women to choose a career in medicine.
- 17 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12439, PC1243903
VCSELs for optical wireless communication
Two-dimensional hexagonal VCSEL arrays with up to 37 VCSELs per array and emitting at 940 nm to 1020 nm are produced on GaAs substrates. Arrays with variable oxide aperture diameters and new processing geometries, with a focus on optimizing the tradeoffs in optical output power, bandwidth, power conversion efficiency, and emitted far field pattern for applications in optical wireless communications are characterized and compared. Standard on wafer probing and packaged array tests are performed including terrestrial free space measurements demonstrating the viability of the core VCSEL array technology for fifth, sixth, and next generation optical wireless systems.
- 17 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12439, PC1243903
VCSELs for optical wireless communication
Two-dimensional hexagonal VCSEL arrays with up to 37 VCSELs per array and emitting at 940 nm to 1020 nm are produced on GaAs substrates. Arrays with variable oxide aperture diameters and new processing geometries, with a focus on optimizing the tradeoffs in optical output power, bandwidth, power conversion efficiency, and emitted far field pattern for applications in optical wireless communications are characterized and compared. Standard on wafer probing and packaged array tests are performed including terrestrial free space measurements demonstrating the viability of the core VCSEL array technology for fifth, sixth, and next generation optical wireless systems.
- 16 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12387, 20
Miniaturized, high performance microscopes for point-of-care applications (Conference Presentation)
For the industrialization of Point-of-care applications, the miniaturization of diagnostic microscopes maintaining their performance for a reasonable pricing and a fast time-to-market are the biggest challenges. Providing application-tailored digital microscope subsystems for integration into next-generation devices, they have to meet the needs for image quality, automation and digitalization. With the invention of JENOPTIK SYIONS as a platform for many different applications (E.g. fluorescence, bright field, dark-field, Raman microscopy) a concept is proven to be reliable and flexible on, e.g. size, application-dependent target resolutions or needed field-of views.
- 16 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12387, 20
Miniaturized, high performance microscopes for point-of-care applications (Conference Presentation)
For the industrialization of Point-of-care applications, the miniaturization of diagnostic microscopes maintaining their performance for a reasonable pricing and a fast time-to-market are the biggest challenges. Providing application-tailored digital microscope subsystems for integration into next-generation devices, they have to meet the needs for image quality, automation and digitalization. With the invention of JENOPTIK SYIONS as a platform for many different applications (E.g. fluorescence, bright field, dark-field, Raman microscopy) a concept is proven to be reliable and flexible on, e.g. size, application-dependent target resolutions or needed field-of views.