Types
Government, Funder
Locations
Albany, United States

Latest Publications

  • Open Access

    Load Testing and Rating of Simple-Span Prestressed Concrete Bridges with no Record Plans

    by Osman Hag-Elsafi, Jonathan Kunin, Sreenivas Alampalli

    This paper introduces a pioneering approach for load testing and rating of simple-span prestressed concrete bridges when design information about the structure is not available. The paper uses the testing of a bridge in New York for illustration of the proposed approach. The bridge was built in 1961 and consisted of five simply supported 70-ft-long post-tensioned bulb-T beams. No documents or plans for the structure were available at the time of the testing. In 1970, the structure was posted for 12 tons. The absence of the bridge plans, coupled with the public’s demand to accommodate school bus traffic on the bridge, prompted the load testing and rating. A plan based on an assumed design basis andinvestigation of bridge behavior under controlled truck loading was proposed to determine unknown design parameters and enable load rating of the structure. The bridge was then instrumented and load tested using trucks of known weights and configurations, positioned at specified locations on the deck to gradually increase their safe load effects on the structure. The results of the testing provided the required information about the bridge and allowed for load rating of the structure.

  • How Lateral Bracing is Used for New and Rehabilitated Composite I-Girder Bridges across Europe and North America

    by Victor Vestman, Harry White, Peter Collin, Heikki Lilja, Timo Tirkkonen, Mikko Peltomaa, Javier Jordan, Jacques Berthellemy, Robert Hällmark


  • Open Access

    Evaluation of HPC Pavement in Nelsonville, Ohio, using Non-destructive Methods

    by Shad Sargand, Mark Swanlund, Julian Bendana, Daniel Castro

    This paper is focused on evaluating the performance of several concrete mixes of high-performance concrete (HPC) pavement using different techniques such as laboratory testing, warping and curling monitoring and falling weight deflectometer testing. A research plan was developed to accomplish two principal objectives: First, to determine the maturity function of the newly placed concrete, and second, to monitor dynamic and environmental response of concrete slabs in each of three test sections. Each test section was approximately 1,000 feet long. Five hundred feet of each test section were cured using a spray-on membrane, while the other five hundred feet were cured using wet burlap. Three Concrete mixes using different types and sizes of coarse aggregate and granulated blast furnace slag were incorporated into this project. Two slabs in each test section were instrumented with thermocouple sticks at the center and outside corners.

  • Open Access

    Load Testing Application for Truss Bridge Design Verification: Dead Load Monitoring

    by Osman Hag-Elsafi, Jonathan Kunin, Sreenivas Alampalli

    This is the first of two papers discussing application of load testing techniques for verification of bridge design. The bridge was a truss structure in the State of New York, which atypical to conventional design, the top chords of the main trusses, floor beams, and stringers were designed to act composite with the concrete deck. Under load, in addition to axial forces, such a design creates secondary moments in the truss main members and complicates the analysis. This inspired the need for verification of the bridge design through an instrumentation, monitoring, and load testing program. The objective of this paper is to verify dead load design. Achieving this objective required instrumentation of main members of the erected structure and monitoring of strains in those members during concrete deck construction. For total dead load, a pseudo analytical approach was used to incorporate load effects due to self-weight of the structure. Five members of the downstream truss were instrumented with vibrating wire gages to record strains in those members during the first three deck pours. Finite element (FE) and deck monitoring results were utilized in the pseudo analytical approach to investigate actual axial forces and moments due to service total dead loads. The investigation indicated that those forces and moments were within 20 percent of those estimated based on FE analysis during the bridge design. The way the deck pours were accounted for in the design and presence of construction loads on the deck during the monitoring might have contributed to this difference. The paper’s major contribution is that it introduced a new approach for estimating total dead load effects by only monitoring strains in a limited number of truss members during staged deck construction, it validated the unconventional design as a viable method for design of truss bridge structures, and it supplemented the very limited literature on dead load monitoring of bridges.

  • Open Access

    Load Testing Application for Truss Bridge Design Verification: Live Load Testing

    by Osman Hag-Elsafi, Jonathan Kunin, Sreenivas Alampalli

    This is the second of two companion papers discussing application of load testing techniques for verification of bridge design. The bridge was a six-spans continuous steel truss structure, about 338-m long and 14.45-m wide, in the State of New York. Design of the bridge was completed using an unconventional approach where the top chords of the main trusses, floor beams, and stringers were designed to act composite with the concrete deck. In addition to axial forces, such a design also gives rise to secondary moments in the truss main members under design loads. This aroused interest in verification of the design through an instrumentation, monitoring, and load testing program. Comparing the members’ actual service load axial forces and moments with those used in the design, it was concluded that axial forces were overestimated in the design by about 20 percent for service dead load and by about 25 percent for service live load. Similar comparison for moments, indicated that service dead load moments were within 20 percent of those used in the design and service live load moments were underestimated by about 55 percent. The above differences for service dead load can be attributed to the way the deck pours were accounted for in the design and the possibility of construction loads being on the structure during the deck pour monitoring. For service live load, these differences can be explained by possible discrepancies in estimating service live load from the test results and the fact that the analysis for service live load in the design was performed ignoring the contribution of the composite concrete deck. Adequacy of the structural design under actual axial forces and moments was confirmed by checking the AASHTO interaction equations for steel members under combined axial and bending loading conditions. The major contribution of this and the companion paper is that, they introduced a new approach for estimating total dead load effects by only monitoring strains in a limited number of truss members during staged deck construction and load testing of a very large truss bridge structure, it validated the unconventional design under both dead load and live load as a viable method for design of truss bridge structures, and it supplemented the very limited literature on dead load monitoring of bridges.

  • Open Access

    Higher-Order Effects in Biaxial Flexure of GFRP I-Section Beams

    by Zia Razzaq, Faridoon Z. Razzaq

    A theoretical study of Glass Fiber Reinforced Polymer (GFRP) beams subjected to biaxial bending moments is presented with a focus on the influence of higher-order effects on maximum normal stresses. It is shown that the biaxial bending type of loading causes a dramatic increase in the maximum normal stress for a GFRP beam when induced torsional effects are included. The study demonstrates that the traditional first-order theory can grossly underestimate the maximum normal stress in a GFRP beam. Based on the numerical results presented using a higher-order theory which also accounts for induced warping normal stresses, the maximum normal stress is found to be about two to three times larger than that determined using the first-order theory.

  • Statewide Assessment of Balanced Mixture Design for New York State’s Asphalt Mixtures

    by Thomas Bennert, Edwin Haas, Edward Wass, Drew Tulanowski, Zoeb Zavery

    As state agencies want greater assurance that their asphalt materials will last longer, the inclusion of performance testing during mixture design and production has gained popularity. In particular, the concept of determining the asphalt content that optimizes asphalt mixture rutting and fatigue cracking resistance, called balanced mixture design (BMD), is being explored in the U.S. In this study, the New York State Department of Transportation (NYSDOT) orchestrated a statewide evaluation of their asphalt mixtures under the BMD concept. Eleven asphalt mixtures, representing a majority of what is utilized as surface courses on New York (NY) asphalt pavements, were first volumetrically verified and then evaluated using BMD to determine the range of asphalt content where rutting and fatigue cracking resistance optimization are achieved. Three laboratory rutting tests (asphalt pavement analyzer [APA], Hamburg wheel tracking [HWT], and high temperature indirect tensile strength [HT-IDT]), and three fatigue cracking tests (overlay tester, semi-circular bending [SCB] flexibility index, and indirect tensile asphalt cracking test [IDEAL-CT] index) were utilized during the performance testing. The results showed that 6 of the 11 volumetrically designed asphalt mixtures were under-asphalted with respect to achieving minimum fatigue cracking resistance based on the laboratory tests. None of the volumetrically designed asphalt mixtures were determined to have rutting issues. The addition of polymer modification in the asphalt binders was found to increase the range of asphalt contents achieving a balanced condition. The study also showed that, when appropriate performance criteria are selected, it is possible to utilize different test methods.


  • Integration of AASHTO Element Data Into the New York State Department of Transportation Bridge Management System: Treatments and Project Selection

    by Kathryn Malarich, Thomas Leckrone, Paul D. Thompson, Keith Gager, Sreenivas Alampalli

    The New York State Department of Transportation (NYSDOT) started collecting AASHTO element-based inspection data as part of bridge inspections in 2016 after retiring its legacy condition inspection system that was in use for more than four decades. A research project was initiated to develop a methodology to integrate AASHTO element-based inspection data into NYSDOT bridge management decision-making processes, guidelines, and bridge performance measures. A logic was developed, based primarily on AASHTO element inspection data, for identifying the work needs for each bridge and predicting the change in element condition states should the resulting work recommendations be implemented. Based on a thorough evaluation of the developed logic, appropriate changes to NYSDOT’s bridge management system are recommended. This paper briefly describes the current study and findings.

  • Evaluation of the Consistency of Bridge Inspection Ratings in New York State

    by Anil Kumar Agrawal, Glenn Washer, Sreenivas Alampalli, Xu Gong, Ran Cao

    Previous studies by the Federal Highway Administration (FHWA) have shown significant variability in the rating of bridge elements through visual inspection. In this study, a detailed evaluation of the consistency of inspection ratings of four representative bridges in New York State has been conducted, using inspection data reported by 21 inspection teams employed by the New York State Department of Transportation (NYSDOT). The bridge condition rating scale of NYSDOT ranges from 7 to 1, with 7 being new and 1 being in a failed condition. In addition, the NYSDOT assigns ratings 8 and 9 to cases “not applicable” and “condition and/or existence unknown,” respectively. In general, consistency is defined as “conformity with practices and procedures.” In this study, consistency of inspection of elements has been quantified as a percentage of inspectors that rated the bridge element within ±1 of the median rating for elements with ratings 7 to 1, or as a percentage of inspectors who have assigned a rating of 8 or 9 to elements expected to be rated 8 or 9. Based on the evaluation of the consistency of elements of the four bridges in the study, the results show that 96% of the elements have a consistency of at least 90%. Only seven elements have been identified to have a consistency of less than 90%. For elements whose rating was supposed to be 8, approximately 97% of the elements had a consistency of at least 90%, whereas, for elements whose rating was supposed to be 9, 91% of the elements were inspected with a consistency of at least 95%. Overall team consistency based on inspection of all elements was approximately 98%. The results imply that the NYSDOT bridge inspection and training programs are effective, as evidenced by the reporting of consistent bridge ratings by multiple inspection teams.