Universal Biosensors (Australia)
Type
CompanyLocations
Rowville, AustraliaLatest Publications
- 14 August 2026
- Published by Springer Nature
- p. 27-45
Fashion Second-Hand Market and Re-Branding of Humana Portugal: One Strategy for Sustainability and Circular Economy
- 14 August 2026
- Published by Springer Nature
- p. 27-45
Fashion Second-Hand Market and Re-Branding of Humana Portugal: One Strategy for Sustainability and Circular Economy
- 2 August 2026
- Published by Springer Nature
- p. 694-704
Corporate Social Responsibility and Organizational Sustainability: An ESG-and-AI Framework for Better Performance
- 2 August 2026
- Published by Springer Nature
- p. 694-704
Corporate Social Responsibility and Organizational Sustainability: An ESG-and-AI Framework for Better Performance
- Open Access
- 1 September 2024
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 85 (9) , 1-9
A veterinary-calibrated point-of-care glucometer accurately measures blood glucose concentration in dogs and cats
OBJECTIVE: To determine the clinical and analytical accuracy of a new veterinary-calibrated portable blood glucose monitor (PBGM) compared to a reference laboratory analyzer. ANIMALS: Client-owned dogs (n = 77) and cats (n = 64). METHODS: Peripheral and paired capillary whole-blood glucose concentrations measured via PBGM were compared to plasma glucose concentrations measured via a Cobas c501 reference analyzer (Roche). Analytical accuracy was evaluated with the Spearman rank correlation coefficient, Bland-Altman difference plot analysis, and Deming regression. Clinical accuracy was evaluated with Parkes error grid analysis. Paired peripheral and capillary blood samples were compared with the Wilcoxon matched-pairs signed-rank test. RESULTS: There was a high correlation between PBGM and reference analyzer readings in dogs and cats. Human quality assurance standards (International Organization for Standardization 15197:2013 guidelines) for analytical accuracy were met for 95% of feline peripheral blood samples and 89% of canine samples. Similar veterinary standards (American Society of Veterinary Clinical Pathology guidelines) were met for 89% of canine and 92% of feline peripheral blood glucose measurements. Error grid analysis showed that all peripheral canine and 97% of feline measurements were clinically accurate (zone A). Any altered clinical decision for the remaining feline measurements was expected to minimally impact outcome (zone B). No significant difference was found between peripheral and capillary blood glucose measurements in either species. CLINICAL RELEVANCE: The PBGM produced clinically accurate results and is suitable for use in veterinary and home settings to measure blood glucose.
- 1 September 2024
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 85 (9) , 1-9
Open AccessA veterinary-calibrated point-of-care glucometer accurately measures blood glucose concentration in dogs and cats
OBJECTIVE: To determine the clinical and analytical accuracy of a new veterinary-calibrated portable blood glucose monitor (PBGM) compared to a reference laboratory analyzer. ANIMALS: Client-owned dogs (n = 77) and cats (n = 64). METHODS: Peripheral and paired capillary whole-blood glucose concentrations measured via PBGM were compared to plasma glucose concentrations measured via a Cobas c501 reference analyzer (Roche). Analytical accuracy was evaluated with the Spearman rank correlation coefficient, Bland-Altman difference plot analysis, and Deming regression. Clinical accuracy was evaluated with Parkes error grid analysis. Paired peripheral and capillary blood samples were compared with the Wilcoxon matched-pairs signed-rank test. RESULTS: There was a high correlation between PBGM and reference analyzer readings in dogs and cats. Human quality assurance standards (International Organization for Standardization 15197:2013 guidelines) for analytical accuracy were met for 95% of feline peripheral blood samples and 89% of canine samples. Similar veterinary standards (American Society of Veterinary Clinical Pathology guidelines) were met for 89% of canine and 92% of feline peripheral blood glucose measurements. Error grid analysis showed that all peripheral canine and 97% of feline measurements were clinically accurate (zone A). Any altered clinical decision for the remaining feline measurements was expected to minimally impact outcome (zone B). No significant difference was found between peripheral and capillary blood glucose measurements in either species. CLINICAL RELEVANCE: The PBGM produced clinically accurate results and is suitable for use in veterinary and home settings to measure blood glucose.
- Open Access
- 5 August 2024
- Published by Wiley in Advanced Sensor Research
- Vol. 4 (2)
Complementary Cost‐Effective Electrochemical Platforms for Point‐Of‐Use Biosensing
The COVID‐19 pandemic has illustrated the urgent need for rapid and affordable point‐of‐use diagnostics. Electrochemical biosensors are useful for such applications because they enable quantitative readout and show drastically improved sensitivity compared to prevalent lateral flow technologies. However, to‐date, the poor quality of commercially‐available, mass‐produced electrodes has prohibited the scaled production and commercialization of such biosensors beyond glucose sensing. Low‐cost gold leaf electrodes have previously been developed that can be fabricated with no specialized equipment at the point‐of‐use. These electrodes are more effective for biosensing than prevalent commercially‐available systems. Yet, their manual fabrication can be tedious and is not scalable in its current form. Here, performance of mass‐produced gold electrodes generated using roll‐to‐roll manufacturing is evaluated, offering the potential to scale production. Upon comparison of these electrodes with the gold leaf, it is found that these electrodes are high quality, equivalent to the gold leaf electrodes, and support biosensing applications through the detection of both DNase I and BtsI‐v2 activity with comparable performance. These results demonstrate the role of complementary technologies to achieve point‐of‐use sensing by enabling flexibility between mass‐produced manufacture and on‐site production.
- 5 August 2024
- Published by Wiley in Advanced Sensor Research
- Vol. 4 (2)
Open AccessComplementary Cost‐Effective Electrochemical Platforms for Point‐Of‐Use Biosensing
The COVID‐19 pandemic has illustrated the urgent need for rapid and affordable point‐of‐use diagnostics. Electrochemical biosensors are useful for such applications because they enable quantitative readout and show drastically improved sensitivity compared to prevalent lateral flow technologies. However, to‐date, the poor quality of commercially‐available, mass‐produced electrodes has prohibited the scaled production and commercialization of such biosensors beyond glucose sensing. Low‐cost gold leaf electrodes have previously been developed that can be fabricated with no specialized equipment at the point‐of‐use. These electrodes are more effective for biosensing than prevalent commercially‐available systems. Yet, their manual fabrication can be tedious and is not scalable in its current form. Here, performance of mass‐produced gold electrodes generated using roll‐to‐roll manufacturing is evaluated, offering the potential to scale production. Upon comparison of these electrodes with the gold leaf, it is found that these electrodes are high quality, equivalent to the gold leaf electrodes, and support biosensing applications through the detection of both DNase I and BtsI‐v2 activity with comparable performance. These results demonstrate the role of complementary technologies to achieve point‐of‐use sensing by enabling flexibility between mass‐produced manufacture and on‐site production.
- 1 June 2023
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 41 (16_suppl) , e15046
An electrochemical molecular assay for the detection of cancer-associated Thomsen-Friedenreich glycans.
E15046 Background: Abnormal glycosylation is a fundamental characteristic in cancer cells, where expression of glycans such as Thomsen-Friedenreich (T), Tn, and sialyl-Tn (STn) are related to particular tumour patterns. T, Tn and STn antigens are unusually short and truncated O-glycans expressed on glycoproteins synthesized within cancer cells and not normally found in healthy tissue or circulating within the blood. The association between blood circulating T-glycans and cancer progression and poor prognosis is now well-known and highlights great potential as biomarkers for cancer screening, diagnosis, and surveillance of diseases during treatment and following remission. Despite this potential, there is currently no established molecular assay for detecting or quantifying these biomarkers in blood biopsy samples. Methods: Using a test strip format reminiscent of a blood glucose test, a new electrochemical molecular assay is introduced for the detection of short O-glycans directly in unprocessed bodily fluids. This assay is based on a self-assembling sensing interface consisting of two glycoproteins, recombinant human lubricin (LUB) and peanut agglutin (PNA). In this interface, the LUB functions as both an anti-fouling layer which mitigates electrode passivation in blood and as a crucial component in the biosensing mechanism for generating readable electrical signals in the presence of target glycans. The PNA, a plant-based lectin, presents high binding specificity towards the T glycoform and functions as the sensor recognition element which is bound to the LUB through T glycans naturally present in the highly glycosylated protein backbone. In this sensing interface, electrical signals are generated by engineering a redox reporter, methylene blue into the LUB/PNA interfacial complex, where the electrical signal is altered by the capture of target glycans by PNA and its impact on the molecular dynamics of the LUB/PNA interfacial complex. Results: Using this test strip, it is possible to detect short cancer-related glycans in concentrations as low as nanomolar directly in small volumes of unprocessed whole blood. These test strips likewise show comparable results to an ELISA test developed in parallel for the detection of short O-glycans. The tests carried out with retrospective blood plasma samples from patients presenting three different tumour types, including prostate (18 patients), colorectal (15 patients), and breast cancer (6 patients), and plasma samples from healthy donors (10 different donors) showed differentiation of response signals between healthy and diseased patients. Conclusions: These findings highlight the clinical potential of this new disposable test strip for the detection of tumour associated glycans, which can be incorporated into point-of-care devices, for cancer monitoring and perhaps one day in screening and diagnosis.
- 1 June 2023
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 41 (16_suppl) , e15046
An electrochemical molecular assay for the detection of cancer-associated Thomsen-Friedenreich glycans.
E15046 Background: Abnormal glycosylation is a fundamental characteristic in cancer cells, where expression of glycans such as Thomsen-Friedenreich (T), Tn, and sialyl-Tn (STn) are related to particular tumour patterns. T, Tn and STn antigens are unusually short and truncated O-glycans expressed on glycoproteins synthesized within cancer cells and not normally found in healthy tissue or circulating within the blood. The association between blood circulating T-glycans and cancer progression and poor prognosis is now well-known and highlights great potential as biomarkers for cancer screening, diagnosis, and surveillance of diseases during treatment and following remission. Despite this potential, there is currently no established molecular assay for detecting or quantifying these biomarkers in blood biopsy samples. Methods: Using a test strip format reminiscent of a blood glucose test, a new electrochemical molecular assay is introduced for the detection of short O-glycans directly in unprocessed bodily fluids. This assay is based on a self-assembling sensing interface consisting of two glycoproteins, recombinant human lubricin (LUB) and peanut agglutin (PNA). In this interface, the LUB functions as both an anti-fouling layer which mitigates electrode passivation in blood and as a crucial component in the biosensing mechanism for generating readable electrical signals in the presence of target glycans. The PNA, a plant-based lectin, presents high binding specificity towards the T glycoform and functions as the sensor recognition element which is bound to the LUB through T glycans naturally present in the highly glycosylated protein backbone. In this sensing interface, electrical signals are generated by engineering a redox reporter, methylene blue into the LUB/PNA interfacial complex, where the electrical signal is altered by the capture of target glycans by PNA and its impact on the molecular dynamics of the LUB/PNA interfacial complex. Results: Using this test strip, it is possible to detect short cancer-related glycans in concentrations as low as nanomolar directly in small volumes of unprocessed whole blood. These test strips likewise show comparable results to an ELISA test developed in parallel for the detection of short O-glycans. The tests carried out with retrospective blood plasma samples from patients presenting three different tumour types, including prostate (18 patients), colorectal (15 patients), and breast cancer (6 patients), and plasma samples from healthy donors (10 different donors) showed differentiation of response signals between healthy and diseased patients. Conclusions: These findings highlight the clinical potential of this new disposable test strip for the detection of tumour associated glycans, which can be incorporated into point-of-care devices, for cancer monitoring and perhaps one day in screening and diagnosis.
- Open Access
- 13 April 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (9) , 1930-1938
Reagentless protein-based electrochemical biosensors
The creation of reagentless protein-based biosensors that are capable of monitoring molecular analytes directly in bodily fluids could revolutionize our understanding of biology and personalized health monitoring.
- 13 April 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (9) , 1930-1938
Open AccessReagentless protein-based electrochemical biosensors
The creation of reagentless protein-based biosensors that are capable of monitoring molecular analytes directly in bodily fluids could revolutionize our understanding of biology and personalized health monitoring.
- 14 November 2022
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 7 (11) , 3379-3388
Rapid Point-of-Care Electrochemical Sensor for the Detection of Cancer Tn Antigen Carbohydrate in Whole Unprocessed Blood
Improving outcomes for cancer patients during treatment and monitoring for cancer recurrence requires personalized care which can only be achieved through regular surveillance for biomarkers. Unfortunately, routine detection for blood-based biomarkers is cost-prohibitive using currently specialized laboratories. Using a rapid self-assembly sensing interface amenable to methods of mass production, we demonstrate the ability to detect and quantify a small carbohydrate-based cancer biomarker, Tn antigen (αGalNAc-Ser/Thr) in a small volume of blood, using a test format strip reminiscent of a blood glucose test. The detection of Tn antigen at picomolar levels is achieved through a new transduction mechanism based on the impact of Tn antigen interactions on the molecular dynamic motion of a lectin cross-linked lubricin antifouling brush. In tests performed on retrospective blood plasma samples from patients presenting three different tumor types, differentiation between healthy and diseased patients was achieved, highlighting the clinical potential for cancer monitoring.
- 14 November 2022
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 7 (11) , 3379-3388
Rapid Point-of-Care Electrochemical Sensor for the Detection of Cancer Tn Antigen Carbohydrate in Whole Unprocessed Blood
Improving outcomes for cancer patients during treatment and monitoring for cancer recurrence requires personalized care which can only be achieved through regular surveillance for biomarkers. Unfortunately, routine detection for blood-based biomarkers is cost-prohibitive using currently specialized laboratories. Using a rapid self-assembly sensing interface amenable to methods of mass production, we demonstrate the ability to detect and quantify a small carbohydrate-based cancer biomarker, Tn antigen (αGalNAc-Ser/Thr) in a small volume of blood, using a test format strip reminiscent of a blood glucose test. The detection of Tn antigen at picomolar levels is achieved through a new transduction mechanism based on the impact of Tn antigen interactions on the molecular dynamic motion of a lectin cross-linked lubricin antifouling brush. In tests performed on retrospective blood plasma samples from patients presenting three different tumor types, differentiation between healthy and diseased patients was achieved, highlighting the clinical potential for cancer monitoring.
- 1 February 2022
- Published by National University of Life and Environmental Sciences of Ukraine in Scientific Reports of the National University of Life and Environmental Sciences of Ukraine
- No. 1(95)
New possibilities of bioregulatory approach in therapy of cow mastitis
Food security includes not only the mater of provision of basic foodstuffs to the population, but also the guarantee of their quality and safety for the consumer. These criteria are, especially, important for milk as the main food products. The pathological processes, which are developed in the breast, have negative effect on the quality of milk, and the medical products that are used in their treatment, may affect on the safety of this product. In the article are represented the results of experimental research with the studying of an effectiveness of the bioregulatory approach in the treatment of catarrhal mastitis in cows with the use of medical products, which contain ultra-low doses of biologically active substances. According to the results of the research was found, that the most effective is a combined scheme of treatment of mastitis, which includes the systemic antibiotic Ceftionel, intramuscular injection of Traumeel, intracisternal therapy of Lachesis compositum and local therapy of Traumeel( gel). These products haven’t a withdrawal period towards regarding milk. On the 6 th day of treatment of catarrhal mastitis recovered 100% of cows in this group, and an average duration of treatment was 5.1 days. In the group of cows, which were treated with Ceftionel-50, the nonsteroidal antiinflammatory product Ketoprosen, the syringe-tubes for intracisternal administration Mastamox and udder treatment with Sanofit ointment, only 40% of animals recovered on 6th day, and the mean duration of treatment for catarrhal mastitis was 7.8 days. Animals, which were treated, exclusively, with bioregulatory products for the treatment of catarrhal mastitis, an effectiveness of treatment was 57% on the 6th day, and an average period of complete recovery was 5.7 days. So, the bioregulatory therapy in combination with the antibiotic Ceftionel provides synergistic action and high efficiency with correcting many pathogenetic mechanisms of the inflammatory response, as well as a high safety level of therapeutic measures.
- 1 February 2022
- Published by National University of Life and Environmental Sciences of Ukraine in Scientific Reports of the National University of Life and Environmental Sciences of Ukraine
- No. 1(95)
New possibilities of bioregulatory approach in therapy of cow mastitis
Food security includes not only the mater of provision of basic foodstuffs to the population, but also the guarantee of their quality and safety for the consumer. These criteria are, especially, important for milk as the main food products. The pathological processes, which are developed in the breast, have negative effect on the quality of milk, and the medical products that are used in their treatment, may affect on the safety of this product. In the article are represented the results of experimental research with the studying of an effectiveness of the bioregulatory approach in the treatment of catarrhal mastitis in cows with the use of medical products, which contain ultra-low doses of biologically active substances. According to the results of the research was found, that the most effective is a combined scheme of treatment of mastitis, which includes the systemic antibiotic Ceftionel, intramuscular injection of Traumeel, intracisternal therapy of Lachesis compositum and local therapy of Traumeel( gel). These products haven’t a withdrawal period towards regarding milk. On the 6 th day of treatment of catarrhal mastitis recovered 100% of cows in this group, and an average duration of treatment was 5.1 days. In the group of cows, which were treated with Ceftionel-50, the nonsteroidal antiinflammatory product Ketoprosen, the syringe-tubes for intracisternal administration Mastamox and udder treatment with Sanofit ointment, only 40% of animals recovered on 6th day, and the mean duration of treatment for catarrhal mastitis was 7.8 days. Animals, which were treated, exclusively, with bioregulatory products for the treatment of catarrhal mastitis, an effectiveness of treatment was 57% on the 6th day, and an average period of complete recovery was 5.7 days. So, the bioregulatory therapy in combination with the antibiotic Ceftionel provides synergistic action and high efficiency with correcting many pathogenetic mechanisms of the inflammatory response, as well as a high safety level of therapeutic measures.