Type
Company
Locations
Tokyo, Japan

Latest Publications

  • Biglobal Resolvent Analysis of Off-Design Turbulent Flow Inside a Centrifugal Pump

    by Yonghong Zhong, Laura Victoria Rolandi, Byungjin An, Motohiko Nohmi, Kunihiko Taira

    Understanding flow dynamics inside centrifugal pumps under off-design operating conditions is critical for their design and operation. Biglobal resolvent analysis of turbulent flow inside a model centrifugal pump at a high flow rate past nominal operating condition is presented. At this off-design condition, the flow near the volute tongue exhibits high level of unsteadiness, characterized by a dominant reverse flow on its volute side and impingement-induced vortex formation on its discharge side. On the discharge side of the tongue, the impeller–tongue interactions lead to the formation of an unsteady boundary layer and large-scale turbulent wake. By means of resolvent (input–output) analysis, we reveal the existence of key modes and frequencies that are responsible for the sustained flow unsteadiness. The optimal resolvent modes have the spatial and temporal scales that agree with the oscillations in the boundary layer, indicating a strong correlation between the impingement-induced vortex formation and the perturbation receptivity. The dominant forcing modes appear on the impeller side of the tongue and overlap with the region where reversed flow occurs. The dominant response modes appear on the discharge side of the tongue, containing both boundary layer and wake structures. These findings offer insights into the perturbation amplification mechanisms in centrifugal pumps at off-design operating conditions and highlight the sensitive nature of the tongue region, which can support improved pump designs and flow control strategies.

  • Paradigm Revolution 2030 - Beyond Cliff, Ahead New Paradigm-

    by Manabu Tsujimura

    Since the transistor's invention in 1947 and the start of Moore's Law1) in 1965, semiconductor integration has progressed well, sustained by Dennard Scaling2) and other measures for prolonging Moore's Law. Despite the Paradigm Shift 453) alarm in 2005, the semiconductor industry successfully overcame the "red brick wall" as coined by ITRS4) multiple times, culminating in scaling the Paradigm Cliff 5) in 2020. The industry is now committed to the development of devices and equipment to reach Paradigm Revolution 2030. Though the world is characterized by VUCA (Volatility, Uncertainty, Complexity, Ambiguity) and the effects of COVID-19, the semiconductor market is thriving, and the future direction of technology is clear. Drawing on the industry's success in overcoming the 2005 and 2020 challenges, this paper provides guidelines for developing the semiconductor devices and manufacturing equipment to achieve the goal of Paradigm Revolution 2030.

  • 水中回転円板の減衰固有振動数と減衰比の実測

    by 慎策 中村, 駿希 奈良, 厳 藤浦, 英厳 髙嶋, 政春 内海

    通常,ポンプなどの羽根車の振動トラブルを回避するため,加振周波数範囲から羽根車の固有振動数を離調させている.しかし,近年共振を回避できないケースが増えてきている.共振時に生じる応力が疲労強度以下であれば問題はないが,共振時の応答を計算するには減衰が必要になる.しかし,現状羽根車に作用する流体減衰を求める技術は確立されておらず,発生メカニズムも明らかになっていない.本研究では基礎実験として水中で回転する円板の減衰固有振動数と減衰比を計測し,回転に伴う円板の振動特性の変化を得たのでこれを報告する.

  • Open Access

    Possibility of determining high quantitative fecal occult blood on stool surface using hyperspectral imaging

    by Hiroaki Ikematsu, Yohei Takara, Keiichiro Nishihara, Yuki Kano, Yuji Owaki, Ryuji Okamoto, Takahisa Fujiwara, Toshihiro Takamatsu, Masayuki Yamada, Yutaka Tomioka, et al.

    Background: Fecal immunochemical tests are commonly performed for colorectal cancer screening. Instant fecal occult blood measurement in toilet bowel movements would improve convenience. Hyperspectral imaging (HSI) enables the nondestructive evaluation of materials that are difficult to assess visually. This study aimed to determine whether HSI could be used to identify fecal occult blood on stool surfaces. Methods: The study included 100 patients who underwent colonoscopy, divided into groups A and B (50 patients, each) for creating a discriminant algorithm and validating the accuracy of the algorithm, respectively. In group A, 100 areas were randomly selected from the stool surface, and the fecal occult blood quantitative values were measured and photographed using a hyperspectral camera (cutoff: > 400 ng/mL). A discriminant algorithm image was created to extract spectral feature differences obtained from HSI via machine learning. In group B, 250 random areas were evaluated and compared to fecal occult blood quantitative values, measuring sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV). Results: Groups A and B comprised 28 and 26 patients with cancer, respectively. Cancer detection sensitivity at the 400 ng/mL cutoff was 67.9% and 42.3% in groups A and B, respectively. The discriminant algorithm image exhibited high accuracy in group A (sensitivity; 77.1%, specificity; 96.9%, accuracy; 90.0%, PPV; 93.1%, NPV; 88.7%). In group B, the sensitivity, specificity, accuracy, PPV, and NPV were 83.3, 92.9, 90.8, 76.3, and 95.3%, respectively. Conclusion: HSI can effectively discriminate high quantitative fecal occult blood, highlighting its potential for improved colorectal cancer screening.


  • Open Access

    Heat Transfer of the Stratified/Wavy Flow of Water in a Horizontal Tube Part2

    by Riku Shingo, Taiga Hashimoto, Kunito Okuyama, Tomoyoshi Irie, Jun Aoyama

    Heat transfer of the stratified/wavy water flow in a horizontal tube is investigated. Considerably low heat transfer in the vapor phase region relative to the liquid phase region produces a large temperature distribution along the perimeter, which makes difficult for deriving the appropriate expression for the heat transfer coefficient. In the 1st report, it was shown that, based on the experiment, the heat transfer coefficient in the liquid phase could be a representative of the entire tube. A model which involved both of convection and evaporation was proposed, where a flat surface of the liquid layer was assumed. In the 2nd report, the spread of the liquid layer due to wetting with the tube surface and its effects on the heat transfer coefficient were accounted for. The prediction agreed with the measured results within approximately 30% error, which is more accurate compared to the prediction for a flat surface.

  • Open Access

    Heat Transfer of the Stratified/Wavy Flow of Water in a Horizontal Tube Part1

    by Riku Shingo, Taiga Hashimoto, Kunito Okuyama, Tomoyoshi Irie, Jun Aoyama

    Heat transfer of the stratified/wavy water flow in a horizontal tube is investigated. Under uniform heating, considerably low heat transfer in the vapor phase region relative to the liquid phase region produces a large circumferential temperature distribution, which makes useless to apply the averaged heat transfer coefficient over the perimeter for the estimation of the heat transfer area of heat exchangers. From the distributions of the actual surface heat flux evaluated experimentally, it is confirmed that the heat circumferentially conducted through the tube over the vapor phase region does not affect the liquid phase region due to the high heat transfer in the proximity of the phase boundary. The heat transfer coefficient in the liquid phase is regarded as a representative of the heat transfer of the stratified/wavy flow and predicted by accounting for the contributions of convection and evaporation and compared with measurements.


  • The Effect of Surfactants on the Removal of Ceria Particles in the Buff Clean Process

    by Yingjie Wang, Qiancheng Sun, Wenlong Tang, Li-Na Qiu, Xin-Ping Qu, Satomi Hamada, Yutaka Wada, Hirokuni Hiyama

    In this work, we have established a new buff clean method, using deionized water (DIW) with 2000 ppm surfactants to remove ceria particles from the surface of SiO2 after chemical mechanical polishing (CMP). Six kinds of surfactants have been compared. The SEM and AFM results show that with CAO and LAPAO, the ceria particles can be fully removed in the buff clean process. The molecular activity and adsorption energy of surfactants are calculated based on the density functional theory (DFT) to clarify the mechanism of the buff clean process. The surfactants adsorbing on the SiO2 surface can be fully removed after the buff clean process.


  • Analysis of CeO2 Adsorption to Various Materials (SiO2, Si3N4, poly-Si) on the Surface of Semiconductor Substrates by First-Principles Calculation

    by Koichi Masuya, Masashi Obuchi, Chikako Takatoh, Megumi Uno, Satomi Hamada, Masamitsu Kurashita, Akira Fukunaga, Masuhiro Mikami

  • Wafer Cleaning with PVA Roller Brushes

    by Toshiyuki Sanada, Shota Suzuki, Yuki Mizushima, Satomi Hamada

    PVA roller brushes are widely used for cleaning after the CMP process, one of the semiconductor manufacturing processes. The PVA roller brush features protrusions called nodules and rotates on the semiconductor wafer in cleaning. This article introduces a cleaning model that uses that PVA roller brush to remove nanoscale impurities. The evanescent fields on a prism enable us to observe the contact behavior of the brush nodules and clarify that there is little brush volume near the surface during sliding. We classified brush deformation into three types depending on the relative velocity of the wafer and nodule. A stamped contact occurs at a negative relative velocity, i.e., when the wafer overtakes the nodule, and this contact is related to cross-contamination from the brush. Finally, we present a model where water absorption and desorption associated with nodule volume deformation plays an important role in nanoscale impurities removal.