Type
Company
Locations
Shelton, United States
Relationships
Child Organizations

Latest Publications

  • Connectors, Connectors, Connectors: Aren't They All the Same?

    by Lee Herron, Mark R. Hilbert, Daleep C. Mohla, Gregory Steinman

    Using a connector not rated for the application and improper installation is a cause of power interruption in industrial and commercial facilities. This paper provides a primer for proper selection and installation practices to improve electrical distribution system reliability and performance. The goal of any electrical system is to perform functionally for the life of the system. This paper reviews the types and technical characteristics of electrical connectors that are used for distinct functions within the overall electrical system, such as grounding, bonding, and power connections. Environmental considerations such as direct burial, wet locations, and sunlight resistance are addressed. New connector applications such as line side of the service ratings are introduced. The paper also addresses the characteristics of connectors and installation practices for applications over 1000 Volts. Connector installation information, such as torque requirements, finely stranded conductor impacts, hole spacing guides per the National Electrical Manufacturers Association (NEMA) standard, voltage limitations and temperature rating ampacity impacts are outlined.


  • Open Access

    Floating Neutral Detection Using Actual Generation of Form 2S Meters

    by I. Vicente, A. Arrinda, J. E. Rodríguez-Seco, L. Piyasinghe

    In the low-voltage distribution system of the USA, Canada and some countries of Central and South America, the most used configuration is the single-phase three-wire system (120 V/240 V) also known as the split-phase distribution system. When the neutral wire of the distribution system gets damaged or broken the current returns through the ground and a Floating Neutral condition arises. Service to the house continues without interruptions because no high over-currents come up. If the return path impedance is high enough, the equally balanced voltage system gets shifted, going out of boundaries and causing malfunctions in the appliances or even fire. A new classification-based detector is proposed to detect this condition, which only needs current measurements that the actual generation of form 2S meter gathers. Moreover, due to the simplicity of the algorithm, it can be embedded in the current generation of meters, which represents great potential of the detector. To that end, the low-voltage distribution system is modelled using a real database and some assumptions are made. The proposed novel detector approach shows zero false alarms in the houses tested and a detection time that allows the fault to be detected before significant damage occurs to the house.

  • Floating neutral detection using a form 2S meter: large distribution lines with multiple houses and rooftop PV effect

    by I. Vicente, L. Piyasinghe, A. Arrinda, E. Rodríguez-Seco

    Different concerns about power quality (PQ) arise in electricity distribution systems that use the single-phase three-wire system (120 V/240 V). One of the most important is what happens when the neutral wire of the distribution system gets damaged or broken, in which case the current returns through the ground and a Floating Neutral (FN) condition arises. One of the main goals from the industry perspective is to identify this problem from the measurements obtained from the secondary equipment as the smart meters (SM). To that end, the authors model a long distribution line with more than one house and analyse the behaviour of the parameters measured at the SM location. Two main conclusions are obtained as a result of this research: the single house simplified model can be used to face the large line configuration and more detailed analysis must be done on distribution lines that contain rooftop photovoltaics (PV).


  • Computer Simulation of ZnO Varistors Failures

    by M. Bartkowiak, G. D. Mahan, M. G. Comber, M. A. Alim

  • Voronoi network model of ZnO varistors with different types of grain boundaries

    by M. Bartkowiak, G. D. Mahan, F. A. Modine, M. A. Alim, R. Lauf, A. McMillan

    Electrical transport in zinc oxide varistors is simulated using two‐dimensional Voronoi networks. The networks are assumed to contain randomly distributed grain boundaries of three electrical types: (1) high nonlinearity (i.e., ‘‘good’’) junctions; (2) poor nonlinearity (i.e., ‘‘bad’’) junctions; and (3) linear with low‐resistivity (i.e., ohmic) junctions. These type classifications are those found in experimental measurements. By varying the type concentrations, the simulated current density versus electric field (J–E) characteristics can be made to conform to the different experimentally observed characteristics of ZnO varistors. These characteristics include the sharpness of switching at the transition between ohmic and nonlinear J–E response (i.e., knee region), as well as the degree of nonlinearity. It is shown that the reduction of the nonlinearity coefficient of bulk varistors, relative to that of isolated grain boundaries, can be explained only by the presence of ‘‘bad’’ varistor junctions.


  • Energy handling capability of ZnO varistors

    by M. Bartkowiak, M. G. Comber, G. D. Mahan

    Thermal and mechanical behavior of high power ZnO surge arresters under current pulses of various magnitude and duration is simulated. By solving heat transfer equations for a varistor disk with nonuniform electrical properties, we compute the time dependence of the temperature profile and the distribution of thermal stresses. The simulations identify failure processes and determine energy handling capability of varistor elements as a function of the applied current. The results are in good agreement with the experimental data and explain the energy handling dependence upon the surge intensity and duration.


  • Influence of ohmic grain boundaries in ZnO varistors

    by M. Bartkowiak, G. D. Mahan, F. A. Modine, M. A. Alim

    A realistic model of transport properties of zinc oxide varistors is constructed from two‐dimensional Voronoi networks and studied via computer simulations. In agreement with experimental microcontact measurements made on individual junctions, the networks are assumed to contain randomly distributed microjunctions of two types: (1) electrically active with highly nonlinear current‐voltage (I‐V) characteristics and (2) ohmic, i.e., with linear I‐V characteristics. Effects of the ohmic grain boundaries in the network are simulated for various concentrations and resistivities. Shapes of the simulated I‐V characteristics and current dependence of the coefficient of nonlinearity of the network are in good agreement with those experimentally observed for thin varistor samples and in the measurements employing various surface electrode patterns. It is found that the breakdown voltage of the networks increases with the number of the ohmic grain boundaries, except when their resistivity is so low that it becomes comparable with that of the ZnO grains. The maximal value of the coefficient of nonlinearity of the network is shown to be insensitive to the presence of the ohmic grain boundaries, regardless of their resistivity and concentration.


  • Open Access

    Electrical Characterization of Engineering Materials

    by Mohammad A. Alim

    Engineering material systems for smart components and novel device applications require a thorough understanding on the structure-property-processing relationships to optimize their performance. The factors determining performance characteristics of the multi-phase/component heterogeneous polycrystalline hybrid (MPCHPH) systems are not identical to devices based on single-crystal/single-junction (SCSJ) technology. Performing SCSJ-like data-analysis on the MPCHPH systems can lead to confusion in delineating simultaneously operative phenomena when “physical geometrical factors”are used in normalizing the as-measuredelectrical parametersorelectrical quantities. Such an analytical approach can vitiate interpretation when microstructural inhomogeneity plays a key role in determining the electrical path. The advantage of using the as-measuredelectrical parametersorelectrical quantitiesconstituting the “immittance function” is emphasized. The “state of normalization” usingphysical geometrical factorscan only be executed for a specific phenomenon when isolated from the total electrical behavior.


  • An analysis of the Mott-Schottky behavior in ZnO-Bi2O3 based varistors

    by Mohammad A. Alim

    A series of non‐converging frequency‐dependent Mott–Schottky straight lines can lead to significant errors in the calculation of the device‐related parameters (such as; built‐in‐potential, barrier height, carrier concentration, etc.) for the ZnO‐Bi2O3 based varistors. These errors are illustrated using the frequency‐dependent slope of these straight lines. To avoid this problem, a method of obtaining the frequency‐independent Mott‐Schottky response has been devised for these devices. This method employs the well‐known lumped parameter/complex plane analysis technique, and thereby resolves the complexity of the frequency‐dependent Mott–Schottky response. Using this technique, it is possible to characterize the Mott–Schottky behavior of varistor materials without incorporating frequency‐dependent phenomenon in the analysis. These parameters are self‐consistent, and satisfy the basic/classical Mott‐Schottky equation.