Arkray (Japan)
Types
Company, FunderLocations
Kyoto, JapanLatest Publications
- Open Access
- 6 August 2026
- Published by Springer Nature in Breast Cancer Research
- Vol. 28 (1)
Multicenter development and validation of a serum microRNA–based diagnostic model for breast cancer and its association with tumor burden and biological aggressiveness: an observational case-control study
Background: Although mammography remains the cornerstone of breast cancer screening, its diagnostic performance is influenced by factors such as breast density and tumor characteristics. Blood-based biomarkers may therefore provide complementary biological information to imaging-based detection strategies. While circulating microRNAs (miRNAs) have emerged as promising minimally invasive biomarkers, their diagnostic performance and associations with clinicopathological characteristics remain incompletely understood. This multicenter study aimed to develop and validate a serum miRNA–based diagnostic model for breast cancer and to evaluate its associations with clinical stage, histological grade, and imaging-related factors. Methods: In this multicenter observational case-control study, serum samples from 345 patients with breast cancer and 373 cancer-free controls were analyzed using next-generation sequencing–based miRNA profiling. After normalization and batch correction, 114 stably expressed miRNAs were selected for model construction. An ensemble machine learning model integrating five algorithms (Lasso, Ridge, support vector machine, Nu-SVM, and histogram-based gradient boosting) was developed using a training cohort ( n = 569) and evaluated in a held-out test cohort ( n = 149). Model performance was assessed using receiver operating characteristic curve analysis and the area under the curve (AUC) with 95% confidence intervals calculated by the DeLong method. Model-derived prediction scores were further evaluated in relation to clinicopathological and imaging-related variables. Results: The serum miRNA–based diagnostic model demonstrated promising discrimination between breast cancer cases and cancer-free controls, with an AUC of 0.875 (95% CI, 0.820–0.930) in the held-out test set. Model-derived prediction scores increased with advancing clinical stage and showed an ordered trend across histological grades. In exploratory analyses, prediction scores tended to increase across higher clinical T categories and were higher among patients with distant metastasis, whereas no clear differences were observed according to mammographic category, breast density, or intrinsic tumor subtype. Conclusions: In this multicenter case-control study, a serum miRNA–based ensemble model demonstrated promising diagnostic discrimination for breast cancer. The model-derived prediction score was associated with clinical stage and histological grade, suggesting that circulating miRNA profiles may provide biologically relevant information beyond binary case-control discrimination. These findings support further investigation of serum miRNA profiling as a potential adjunctive diagnostic approach; however, prospective validation in representative screening populations is required before clinical implementation. Trial registration: Not applicable.
- 6 August 2026
- Published by Springer Nature in Breast Cancer Research
- Vol. 28 (1)
Open AccessMulticenter development and validation of a serum microRNA–based diagnostic model for breast cancer and its association with tumor burden and biological aggressiveness: an observational case-control study
Background: Although mammography remains the cornerstone of breast cancer screening, its diagnostic performance is influenced by factors such as breast density and tumor characteristics. Blood-based biomarkers may therefore provide complementary biological information to imaging-based detection strategies. While circulating microRNAs (miRNAs) have emerged as promising minimally invasive biomarkers, their diagnostic performance and associations with clinicopathological characteristics remain incompletely understood. This multicenter study aimed to develop and validate a serum miRNA–based diagnostic model for breast cancer and to evaluate its associations with clinical stage, histological grade, and imaging-related factors. Methods: In this multicenter observational case-control study, serum samples from 345 patients with breast cancer and 373 cancer-free controls were analyzed using next-generation sequencing–based miRNA profiling. After normalization and batch correction, 114 stably expressed miRNAs were selected for model construction. An ensemble machine learning model integrating five algorithms (Lasso, Ridge, support vector machine, Nu-SVM, and histogram-based gradient boosting) was developed using a training cohort ( n = 569) and evaluated in a held-out test cohort ( n = 149). Model performance was assessed using receiver operating characteristic curve analysis and the area under the curve (AUC) with 95% confidence intervals calculated by the DeLong method. Model-derived prediction scores were further evaluated in relation to clinicopathological and imaging-related variables. Results: The serum miRNA–based diagnostic model demonstrated promising discrimination between breast cancer cases and cancer-free controls, with an AUC of 0.875 (95% CI, 0.820–0.930) in the held-out test set. Model-derived prediction scores increased with advancing clinical stage and showed an ordered trend across histological grades. In exploratory analyses, prediction scores tended to increase across higher clinical T categories and were higher among patients with distant metastasis, whereas no clear differences were observed according to mammographic category, breast density, or intrinsic tumor subtype. Conclusions: In this multicenter case-control study, a serum miRNA–based ensemble model demonstrated promising diagnostic discrimination for breast cancer. The model-derived prediction score was associated with clinical stage and histological grade, suggesting that circulating miRNA profiles may provide biologically relevant information beyond binary case-control discrimination. These findings support further investigation of serum miRNA profiling as a potential adjunctive diagnostic approach; however, prospective validation in representative screening populations is required before clinical implementation. Trial registration: Not applicable.
- Open Access
Comparison of Comprehensive Serum miRNA Sequencing and Apolipoprotein A2 Isoforms for Early Detection of Pancreatic Cancer
Backgrounds and Aim: Pancreatic cancer is frequently diagnosed at advanced stages, highlighting the need for biomarkers that are capable of detecting early-stage disease in asymptomatic individuals. Recently, apolipoprotein A2 isoforms (ApoA2-ATQ/AT) have been reported as a new blood biomarker for pancreatic cancer. We recently developed diagnostic models based on 100 highly expressed serum microRNAs (miRNAs) combined with CA19-9; these models achieved high accuracy in terms of distinguishing individuals with pancreatic cancer from healthy individuals. This study aimed to compare the diagnostic performance of these miRNA-based models with that of the ApoA2-ATQ/AT biomarker. Methods: Comprehensive sequencing of serum miRNAs was conducted using samples from 120 pancreatic cancer patients recruited across 14 hospitals, along with 93 healthy controls without cancer. Serum CA19-9 levels, miRNA index values, miRNA+CA19-9 index values, and ApoA2 index values were assessed. miRNA-based indices were derived from classification models built on an automated machine-learning platform. Results: The miRNA model (AUC 0.94; 95% CI 0.91–0.97) and the miRNA+CA19-9 model (AUC 0.99; 95% CI 0.98–1.00) outperformed ApoA2 (AUC 0.89; 95% CI 0.84–0.93) in terms of distinguishing individuals with pancreatic cancer from healthy controls across all stages. In early-stage disease (stages 0–I and 0–II), both miRNA-based models also demonstrated superior performance. Strong negative correlations were observed between the ApoA2 index and both the miRNA model index (r = −0.62) and the miRNA+CA19-9 index (r = −0.63). Conclusions: These findings suggest that miRNA-based diagnostic models, particularly when combined with CA19-9, could serve as powerful tools for the early detection of pancreatic cancer.
Open AccessComparison of Comprehensive Serum miRNA Sequencing and Apolipoprotein A2 Isoforms for Early Detection of Pancreatic Cancer
Backgrounds and Aim: Pancreatic cancer is frequently diagnosed at advanced stages, highlighting the need for biomarkers that are capable of detecting early-stage disease in asymptomatic individuals. Recently, apolipoprotein A2 isoforms (ApoA2-ATQ/AT) have been reported as a new blood biomarker for pancreatic cancer. We recently developed diagnostic models based on 100 highly expressed serum microRNAs (miRNAs) combined with CA19-9; these models achieved high accuracy in terms of distinguishing individuals with pancreatic cancer from healthy individuals. This study aimed to compare the diagnostic performance of these miRNA-based models with that of the ApoA2-ATQ/AT biomarker. Methods: Comprehensive sequencing of serum miRNAs was conducted using samples from 120 pancreatic cancer patients recruited across 14 hospitals, along with 93 healthy controls without cancer. Serum CA19-9 levels, miRNA index values, miRNA+CA19-9 index values, and ApoA2 index values were assessed. miRNA-based indices were derived from classification models built on an automated machine-learning platform. Results: The miRNA model (AUC 0.94; 95% CI 0.91–0.97) and the miRNA+CA19-9 model (AUC 0.99; 95% CI 0.98–1.00) outperformed ApoA2 (AUC 0.89; 95% CI 0.84–0.93) in terms of distinguishing individuals with pancreatic cancer from healthy controls across all stages. In early-stage disease (stages 0–I and 0–II), both miRNA-based models also demonstrated superior performance. Strong negative correlations were observed between the ApoA2 index and both the miRNA model index (r = −0.62) and the miRNA+CA19-9 index (r = −0.63). Conclusions: These findings suggest that miRNA-based diagnostic models, particularly when combined with CA19-9, could serve as powerful tools for the early detection of pancreatic cancer.
- Open Access
- 21 January 2026
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 40 (1)
A machine learning model for cancer screening in dogs using comprehensive circulating microRNA profiles
Background: MicroRNAs (miRNAs) are non-coding RNAs involved in cancer-related biological processes. To date, no studies have determined that liquid biopsy using miRNA can specifically identify dogs with cancer from a mixed population of dogs with and without non-malignant diseases. Hypothesis/Objectives: To assess the utility of a diagnostic model that differentiates dogs with cancer from a combined group of healthy dogs and dogs with non-malignant diseases, using miRNA profiles obtained by next-generation sequencing (NGS) and analyzed using machine learning. Animals: A total of 574 dogs were enrolled in the study: 168 with cancer, 138 with non-malignant diseases, and 268 healthy controls. Methods: Plasma samples from all dogs were analyzed by NGS to generate comprehensive miRNA profiles. Models were developed using DataRobot, based on the 50 most highly expressed miRNAs. The optimal model was selected based on area under the curve (AUC) results obtained using 5-fold cross-validation. Results: The miRNA-based model accurately distinguished dogs with cancer from those without cancer, achieving an AUC of 0.907, with both sensitivity and specificity of 0.85. Conclusions and clinical importance: A model integrating NGS-derived miRNA profiles with machine learning can serve as a diagnostic approach for cancer detection in dogs. Such a model can distinguish dogs with cancer from both healthy dogs and those with non-malignant disease. These findings suggest that such a model could be used as a screening test for dogs with cancer in veterinary practice.
- 21 January 2026
- Published by Oxford University Press (OUP) in Journal of Veterinary Internal Medicine
- Vol. 40 (1)
Open AccessA machine learning model for cancer screening in dogs using comprehensive circulating microRNA profiles
Background: MicroRNAs (miRNAs) are non-coding RNAs involved in cancer-related biological processes. To date, no studies have determined that liquid biopsy using miRNA can specifically identify dogs with cancer from a mixed population of dogs with and without non-malignant diseases. Hypothesis/Objectives: To assess the utility of a diagnostic model that differentiates dogs with cancer from a combined group of healthy dogs and dogs with non-malignant diseases, using miRNA profiles obtained by next-generation sequencing (NGS) and analyzed using machine learning. Animals: A total of 574 dogs were enrolled in the study: 168 with cancer, 138 with non-malignant diseases, and 268 healthy controls. Methods: Plasma samples from all dogs were analyzed by NGS to generate comprehensive miRNA profiles. Models were developed using DataRobot, based on the 50 most highly expressed miRNAs. The optimal model was selected based on area under the curve (AUC) results obtained using 5-fold cross-validation. Results: The miRNA-based model accurately distinguished dogs with cancer from those without cancer, achieving an AUC of 0.907, with both sensitivity and specificity of 0.85. Conclusions and clinical importance: A model integrating NGS-derived miRNA profiles with machine learning can serve as a diagnostic approach for cancer detection in dogs. Such a model can distinguish dogs with cancer from both healthy dogs and those with non-malignant disease. These findings suggest that such a model could be used as a screening test for dogs with cancer in veterinary practice.
- Open Access
- 3 April 2025
- Published by Frontiers Media SA in Frontiers in Clinical Diabetes and Healthcare
- Vol. 6, 1465732
System accuracy evaluation of the new blood glucose monitoring meter “GLUCOCARD S onyx” beyond ISO 15197:2013/EN ISO 15197:2015 requirements and with new patient safety features
Introduction: Blood glucose monitoring meters (BGM) have not become redundant yet. The accuracy and precision of “GLUCOCARD S onyx,” a new BGM with Bluetooth function, has been evaluated and proven to exceed the actual ISO 15197:2013/EN ISO 15197:2015 guidelines besides offering features for better patient safety and telemedicine.Methods: 100 finger-prick whole blood samples from subjects with diabetes and 32 without diabetes were collected and measured with GLUCOCARD S onyx. Plasma blood glucose levels were measured using YSI2300 STAT PLUS as reference analyzer for comparison. The evaluation followed ISO 15197:2013, section 6.3 accuracy criteria. Furthermore, the MARD factor was calculated for the overall clinical important range (with n=132 samples).Results: The performance of GLUCOCARD S onyx was evaluated according to ISO 15197:2013, revealing that 99.7% (598/600) of the results fell within ±15% or ±0.8 mmol/L (± 15 mg/dL) of difference over the total clinically relevant glucose range compared to the YSI2300 STAT PLUS. 100% (600/600) of the measurement results over the total range fell within Clark Error Grid Zone A. An overall mean absolute relative difference (MARD) factor of 4.15% was obtained; 5.05% for glucose <5.6 mmol/L (<100 mg/dL), and 3.65% for glucose ≥5.6 mmol/L (≥100 mg/dL).Discussion: GLUCOCARD S onyx shows clinically satisfactory accuracy and reliability, even exceeding the ISO 15197:2013 criteria, for hypoglycemic cases with glucose critically low as <3.9 mmol/L (<70 mg/dL) and hyperglycemic cases with glucose ≥10.0 mmol/L (≥180 mg/dL). Healthcare organizations as well as manufacturers are aiming to offer new BGM systems that go beyond the ISO criteria and offer systems that can be consulted instead or besides CGM (Continuous Glucose Monitoring) in case of e.g. severe hypo- and/or hyperglycemic episodes. A MARD factor of 4.15% revealed an excellent system accuracy over the total clinically relevant glucose range. With additional user-friendly features, this BGM can be seen as a useful tool for efficient diabetes therapy, especially in the event of severe blood glucose fluctuations.
- 3 April 2025
- Published by Frontiers Media SA in Frontiers in Clinical Diabetes and Healthcare
- Vol. 6, 1465732
Open AccessSystem accuracy evaluation of the new blood glucose monitoring meter “GLUCOCARD S onyx” beyond ISO 15197:2013/EN ISO 15197:2015 requirements and with new patient safety features
Introduction: Blood glucose monitoring meters (BGM) have not become redundant yet. The accuracy and precision of “GLUCOCARD S onyx,” a new BGM with Bluetooth function, has been evaluated and proven to exceed the actual ISO 15197:2013/EN ISO 15197:2015 guidelines besides offering features for better patient safety and telemedicine.Methods: 100 finger-prick whole blood samples from subjects with diabetes and 32 without diabetes were collected and measured with GLUCOCARD S onyx. Plasma blood glucose levels were measured using YSI2300 STAT PLUS as reference analyzer for comparison. The evaluation followed ISO 15197:2013, section 6.3 accuracy criteria. Furthermore, the MARD factor was calculated for the overall clinical important range (with n=132 samples).Results: The performance of GLUCOCARD S onyx was evaluated according to ISO 15197:2013, revealing that 99.7% (598/600) of the results fell within ±15% or ±0.8 mmol/L (± 15 mg/dL) of difference over the total clinically relevant glucose range compared to the YSI2300 STAT PLUS. 100% (600/600) of the measurement results over the total range fell within Clark Error Grid Zone A. An overall mean absolute relative difference (MARD) factor of 4.15% was obtained; 5.05% for glucose <5.6 mmol/L (<100 mg/dL), and 3.65% for glucose ≥5.6 mmol/L (≥100 mg/dL).Discussion: GLUCOCARD S onyx shows clinically satisfactory accuracy and reliability, even exceeding the ISO 15197:2013 criteria, for hypoglycemic cases with glucose critically low as <3.9 mmol/L (<70 mg/dL) and hyperglycemic cases with glucose ≥10.0 mmol/L (≥180 mg/dL). Healthcare organizations as well as manufacturers are aiming to offer new BGM systems that go beyond the ISO criteria and offer systems that can be consulted instead or besides CGM (Continuous Glucose Monitoring) in case of e.g. severe hypo- and/or hyperglycemic episodes. A MARD factor of 4.15% revealed an excellent system accuracy over the total clinically relevant glucose range. With additional user-friendly features, this BGM can be seen as a useful tool for efficient diabetes therapy, especially in the event of severe blood glucose fluctuations.
- 5 February 2025
- Published by Elsevier in Thrombosis Research
- Vol. 247, 109283
Dielectric blood coagulometry to evaluate coagulation activity in patients prescribed factor Xa inhibitors undergoing elective surgery: A prospective observational study
- 5 February 2025
- Published by Elsevier in Thrombosis Research
- Vol. 247, 109283
Dielectric blood coagulometry to evaluate coagulation activity in patients prescribed factor Xa inhibitors undergoing elective surgery: A prospective observational study
- 10 December 2024
- Published by Elsevier in Clinica Chimica Acta
- Vol. 567, 120087
Standardization of hemoglobin A2 and hemoglobin F: Achievements and perspectives
- 10 December 2024
- Published by Elsevier in Clinica Chimica Acta
- Vol. 567, 120087
Standardization of hemoglobin A2 and hemoglobin F: Achievements and perspectives
- Open Access
- 26 November 2024
- Published by Elsevier in Veterinary and Animal Science
- Vol. 27, 100414
Development of a sensitive disease-screening model using comprehensive circulating microRNA profiles in dogs: A pilot study
- 26 November 2024
- Published by Elsevier in Veterinary and Animal Science
- Vol. 27, 100414
Open AccessDevelopment of a sensitive disease-screening model using comprehensive circulating microRNA profiles in dogs: A pilot study
- Open Access
- 28 June 2024
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 107 (6) , 943-952
Validation of a New Liquid Asymmetric-Electrode Plasma Optical Emission Spectroscopy (LAEP-OES) Method for Measurement of Total Mercury in Tuna
Background: Mercury intake is caused by eating seafood, such as tuna and other predatory fish species. To reduce the health risks of mercury intake, it is necessary to continuously measure and monitor mercury concentrations at fish farms and markets. We have developed a compact system that can detect multiple heavy metals by liquid asymmetric-electrode plasma optical emission spectroscopy (LAEP-OES). Objective: The validity of the LAEP-OES method for total mercury levels was evaluated using standard solutions, certified substances, and specimens of bluefin tuna and other fish species. Methods: All specimens were dissolved in 4 M lithium hydroxide solution and then dispensed into a sample reservoir well of the single-use measurement reagent pack. Total mercury levels were automatically measured within 15 min of placement into the dedicated equipment. A total of 102 fish specimens, classified into 10 fish species, were evaluated using the new method and the results were compared to those obtained from validated analytical methods. Results: LOD (0.02 mg/kg), LOQ (0.07 mg/kg), repeatability (4.0%), intermediate precision (9.8%), and trueness (recoveries 107%) of the proposed method were within satisfactory limits for total mercury levels in fish. Additionally, when using various fish species, the method had a strong positive correlation with the results of cold-vapor atomic absorption spectrometry (CV-AAS, the official method) with Spearman rs = 0.984. Conclusion: The LAEP-OES method can be used for measuring total mercury levels in bluefin tuna. Total mercury measurement using this new method has the potential to be applied to other fish species. Highlights: Total mercury levels in fish were measured using our unique analysis system. Pacific bluefin tuna, southern bluefin tuna, and Atlantic bluefin tuna distributed in the Japanese market were analyzed for total mercury in their wild and farmed fish varieties.
- 28 June 2024
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 107 (6) , 943-952
Open AccessValidation of a New Liquid Asymmetric-Electrode Plasma Optical Emission Spectroscopy (LAEP-OES) Method for Measurement of Total Mercury in Tuna
Background: Mercury intake is caused by eating seafood, such as tuna and other predatory fish species. To reduce the health risks of mercury intake, it is necessary to continuously measure and monitor mercury concentrations at fish farms and markets. We have developed a compact system that can detect multiple heavy metals by liquid asymmetric-electrode plasma optical emission spectroscopy (LAEP-OES). Objective: The validity of the LAEP-OES method for total mercury levels was evaluated using standard solutions, certified substances, and specimens of bluefin tuna and other fish species. Methods: All specimens were dissolved in 4 M lithium hydroxide solution and then dispensed into a sample reservoir well of the single-use measurement reagent pack. Total mercury levels were automatically measured within 15 min of placement into the dedicated equipment. A total of 102 fish specimens, classified into 10 fish species, were evaluated using the new method and the results were compared to those obtained from validated analytical methods. Results: LOD (0.02 mg/kg), LOQ (0.07 mg/kg), repeatability (4.0%), intermediate precision (9.8%), and trueness (recoveries 107%) of the proposed method were within satisfactory limits for total mercury levels in fish. Additionally, when using various fish species, the method had a strong positive correlation with the results of cold-vapor atomic absorption spectrometry (CV-AAS, the official method) with Spearman rs = 0.984. Conclusion: The LAEP-OES method can be used for measuring total mercury levels in bluefin tuna. Total mercury measurement using this new method has the potential to be applied to other fish species. Highlights: Total mercury levels in fish were measured using our unique analysis system. Pacific bluefin tuna, southern bluefin tuna, and Atlantic bluefin tuna distributed in the Japanese market were analyzed for total mercury in their wild and farmed fish varieties.
- 25 June 2024
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 45 (7-8) , 621-628
Terahertz Characterization Microcellular Polyethylene Terephthalate (MCPET) across Broad Temperature Range
- 25 June 2024
- Published by Springer Nature in Journal of Infrared, Millimeter, and Terahertz Waves
- Vol. 45 (7-8) , 621-628
Terahertz Characterization Microcellular Polyethylene Terephthalate (MCPET) across Broad Temperature Range
- Open Access
- 19 April 2023
- Published by Springer Nature in Journal of Cancer Research and Clinical Oncology
- Vol. 149 (11) , 8297-8305
Comprehensive circulating microRNA profile as a supersensitive biomarker for early-stage lung cancer screening
Purpose: Less-invasive early diagnosis of lung cancer is essential for improving patient survival rates. The purpose of this study is to demonstrate that serum comprehensive miRNA profile is high sensitive biomarker to early-stage lung cancer in direct comparison to the conventional blood biomarker using next-generation sequencing (NGS) technology combined with automated machine learning (AutoML). Methods: We first evaluated the reproducibility of our measurement system using Pearson’s correlation coefficients between samples derived from a single pooled RNA sample. To generate comprehensive miRNA profile, we performed NGS analysis of miRNAs in 262 serum samples. Among the discovery set (57 patients with lung cancer and 57 healthy controls), 1123 miRNA-based diagnostic models for lung cancer detection were constructed and screened using AutoML technology. The diagnostic faculty of the best performance model was evaluated by inspecting the validation samples (74 patients with lung cancer and 74 healthy controls). Results: The Pearson’s correlation coefficients between samples derived from the pooled RNA sample ≥ 0.98. In the validation analysis, the best model showed a high AUC score (0.98) and a high sensitivity for early stage lung cancer (85.7%, n = 28). Furthermore, in comparison to carcinoembryonic antigen (CEA), a conventional blood biomarker for adenocarcinoma, the miRNA-based model showed higher sensitivity for early-stage lung adenocarcinoma (CEA, 27.8%, n = 18; miRNA-based model, 77.8%, n = 18). Conclusion: The miRNA-based diagnostic model showed a high sensitivity for lung cancer, including early-stage disease. Our study provides the experimental evidence that serum comprehensive miRNA profile can be a highly sensitive blood biomarker for early-stage lung cancer.
- 19 April 2023
- Published by Springer Nature in Journal of Cancer Research and Clinical Oncology
- Vol. 149 (11) , 8297-8305
Open AccessComprehensive circulating microRNA profile as a supersensitive biomarker for early-stage lung cancer screening
Purpose: Less-invasive early diagnosis of lung cancer is essential for improving patient survival rates. The purpose of this study is to demonstrate that serum comprehensive miRNA profile is high sensitive biomarker to early-stage lung cancer in direct comparison to the conventional blood biomarker using next-generation sequencing (NGS) technology combined with automated machine learning (AutoML). Methods: We first evaluated the reproducibility of our measurement system using Pearson’s correlation coefficients between samples derived from a single pooled RNA sample. To generate comprehensive miRNA profile, we performed NGS analysis of miRNAs in 262 serum samples. Among the discovery set (57 patients with lung cancer and 57 healthy controls), 1123 miRNA-based diagnostic models for lung cancer detection were constructed and screened using AutoML technology. The diagnostic faculty of the best performance model was evaluated by inspecting the validation samples (74 patients with lung cancer and 74 healthy controls). Results: The Pearson’s correlation coefficients between samples derived from the pooled RNA sample ≥ 0.98. In the validation analysis, the best model showed a high AUC score (0.98) and a high sensitivity for early stage lung cancer (85.7%, n = 28). Furthermore, in comparison to carcinoembryonic antigen (CEA), a conventional blood biomarker for adenocarcinoma, the miRNA-based model showed higher sensitivity for early-stage lung adenocarcinoma (CEA, 27.8%, n = 18; miRNA-based model, 77.8%, n = 18). Conclusion: The miRNA-based diagnostic model showed a high sensitivity for lung cancer, including early-stage disease. Our study provides the experimental evidence that serum comprehensive miRNA profile can be a highly sensitive blood biomarker for early-stage lung cancer.