Ricoh (Japan)

Type
CompanyLocations
Tokyo, JapanRelationships
Latest Publications
- Open Access
- 12 November 2026
- Published by MDPI AG in Preprints.org
Time-Domain NIRS Detection of Neurovascular Coupling Impairment: A Potential Biomarker of Psychological Stress
Chronic psychological stress is associated with adverse health outcomes and substantial socioeconomic burden. Early identification of psychological stress is important for public health, but no biomarker specific to psychological stress has yet been established. Growing evidence suggests that neurovascular coupling (NVC) is impaired under stress conditions. To test this hypothesis, we investigated the relationship between NVC responses and baseline anxiety in 35 healthy participants. Cerebrovascular responses during a finger-tapping task were measured using time-domain near-infrared spectroscopy (TD-NIRS). Baseline anxiety was assessed using the State-Trait Anxiety Inventory (STAI) as an indicator related to psychological stress. After adjusting for age, resting total hemoglobin, and the integration time used for TD-NIRS measurements, the difference in NVC responses between participants with higher and lower STAI-State scores did not reach statistical significance when all participants were included (P = 0.050). After excluding two outliers identified using a 1.0 × IQR criterion, the difference in NVC responses between the two groups became statistically significant (P = 0.027). Participants with higher STAI-State scores showed lower NVC responses than those with lower scores. These findings suggest that impaired NVC may serve as a physiological indicator of psychological stress.
- 12 November 2026
- Published by MDPI AG in Preprints.org
Open AccessTime-Domain NIRS Detection of Neurovascular Coupling Impairment: A Potential Biomarker of Psychological Stress
Chronic psychological stress is associated with adverse health outcomes and substantial socioeconomic burden. Early identification of psychological stress is important for public health, but no biomarker specific to psychological stress has yet been established. Growing evidence suggests that neurovascular coupling (NVC) is impaired under stress conditions. To test this hypothesis, we investigated the relationship between NVC responses and baseline anxiety in 35 healthy participants. Cerebrovascular responses during a finger-tapping task were measured using time-domain near-infrared spectroscopy (TD-NIRS). Baseline anxiety was assessed using the State-Trait Anxiety Inventory (STAI) as an indicator related to psychological stress. After adjusting for age, resting total hemoglobin, and the integration time used for TD-NIRS measurements, the difference in NVC responses between participants with higher and lower STAI-State scores did not reach statistical significance when all participants were included (P = 0.050). After excluding two outliers identified using a 1.0 × IQR criterion, the difference in NVC responses between the two groups became statistically significant (P = 0.027). Participants with higher STAI-State scores showed lower NVC responses than those with lower scores. These findings suggest that impaired NVC may serve as a physiological indicator of psychological stress.
- Open Access
- 21 June 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
High-gamma frequency-tagged magnetoencephalography reveals time-resolved task-related functional coupling during spatial cognition
Fast periodic visual stimulation (FPVS) combined with magnetoencephalography (MEG) provides a powerful approach for extracting frequency-specific brain responses from perceptual processing areas. However, its application in cognitive paradigms, particularly those addressing visuospatial attention, remains underexplored. This study developed an FPVS-based line bisection paradigm to probe visuospatial cognition during visual exploration of the line center using eye movements without manual responses. Line stimuli were spatially modulated at high-gamma frequencies (70-90 Hz), centered at 80 Hz. Source analysis in healthy volunteers revealed a sequential pattern of cortical activation, beginning in the bilateral occipital cortices around 100 ms and subsequently involving right temporoparietal, frontal, and superior parietal regions between approximately 130 and 220 ms. Formal frequency-domain analysis confirmed that 80 Hz Morlet time-frequency power was significantly higher during stimulation than during the pre-stimulus baseline period. Functional connectivity analysis revealed task-related coupling between parietal regions and occipital, frontal, and temporal cortices. These connectivity patterns were anatomically plausible in the context of visuospatial processing. Overall, FPVS-MEG enabled temporally precise mapping of task-related cortical activity and functional coupling during visuospatial processing.
- 21 June 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessHigh-gamma frequency-tagged magnetoencephalography reveals time-resolved task-related functional coupling during spatial cognition
Fast periodic visual stimulation (FPVS) combined with magnetoencephalography (MEG) provides a powerful approach for extracting frequency-specific brain responses from perceptual processing areas. However, its application in cognitive paradigms, particularly those addressing visuospatial attention, remains underexplored. This study developed an FPVS-based line bisection paradigm to probe visuospatial cognition during visual exploration of the line center using eye movements without manual responses. Line stimuli were spatially modulated at high-gamma frequencies (70-90 Hz), centered at 80 Hz. Source analysis in healthy volunteers revealed a sequential pattern of cortical activation, beginning in the bilateral occipital cortices around 100 ms and subsequently involving right temporoparietal, frontal, and superior parietal regions between approximately 130 and 220 ms. Formal frequency-domain analysis confirmed that 80 Hz Morlet time-frequency power was significantly higher during stimulation than during the pre-stimulus baseline period. Functional connectivity analysis revealed task-related coupling between parietal regions and occipital, frontal, and temporal cortices. These connectivity patterns were anatomically plausible in the context of visuospatial processing. Overall, FPVS-MEG enabled temporally precise mapping of task-related cortical activity and functional coupling during visuospatial processing.
- 9 June 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Mathematics
- Vol. 37 (11)
Free paths of arrangements of hyperplanes
In this paper, we study the free path problem, i.e. if we are given two free arrangements of hyperplanes, then we can connect them by free arrangements or not. We prove that if an arrangement [ ] and [ ] are free, then at least one of two among them is free. When [ ] is in the three-dimensional arrangement, we show a stronger statement.
- 9 June 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Mathematics
- Vol. 37 (11)
Free paths of arrangements of hyperplanes
In this paper, we study the free path problem, i.e. if we are given two free arrangements of hyperplanes, then we can connect them by free arrangements or not. We prove that if an arrangement [ ] and [ ] are free, then at least one of two among them is free. When [ ] is in the three-dimensional arrangement, we show a stronger statement.
- Open Access
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 17960-17970
FEM-Based Design and Characterization of a Millimeter-Scale Piezoelectric Resonance Force Sensor
This paper presents a millimeter-scale piezoelectric effect-based force sensor that uses the change in its resonant frequency as the detection principle for high sensitivity and a wide measurement range. Such characteristics are suited for robot hand applications that can not only detect a small force but also handle large payloads. In this paper, we develop a methodology to estimate the relationship between the applied force and the resonant frequency shift by combining classic contact theory and the finite element method (FEM) analysis. Although this relationship is non-linear, the designability of the sensitivity and measurement range is demonstrated by the simulation. The simulation results based on the method are verified, showing good agreement with experimental results. The static characteristics, including sensitivity, standard deviation, and resolution, are evaluated using the prototype sensors with characteristic lengths ranging from 1mmto 4 mm. The 4-mm model has a measurement range of 77 mN to 300 N, and the smallest model, which is one of the smallest force sensors suitable for practical implementation, has a measurement range of 9 mN to 20 N.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 17960-17970
Open AccessFEM-Based Design and Characterization of a Millimeter-Scale Piezoelectric Resonance Force Sensor
This paper presents a millimeter-scale piezoelectric effect-based force sensor that uses the change in its resonant frequency as the detection principle for high sensitivity and a wide measurement range. Such characteristics are suited for robot hand applications that can not only detect a small force but also handle large payloads. In this paper, we develop a methodology to estimate the relationship between the applied force and the resonant frequency shift by combining classic contact theory and the finite element method (FEM) analysis. Although this relationship is non-linear, the designability of the sensitivity and measurement range is demonstrated by the simulation. The simulation results based on the method are verified, showing good agreement with experimental results. The static characteristics, including sensitivity, standard deviation, and resolution, are evaluated using the prototype sensors with characteristic lengths ranging from 1mmto 4 mm. The 4-mm model has a measurement range of 77 mN to 300 N, and the smallest model, which is one of the smallest force sensors suitable for practical implementation, has a measurement range of 9 mN to 20 N.
- 28 October 2025
- Published by Elsevier in Clinical Neurophysiology
- Vol. 181, 2111409
Magnetoneurography as a novel functional imaging technique for cervical myelopathy
- 28 October 2025
- Published by Elsevier in Clinical Neurophysiology
- Vol. 181, 2111409
Magnetoneurography as a novel functional imaging technique for cervical myelopathy
- 16 October 2025
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 43 (4) , 332-339
Visualization of Neural Activity in the Upper and Middle Lumbar Spine Using Magnetospinography After Lateral Femoral Cutaneous, Saphenous, and Femoral Nerve Stimulation
Purpose: Magnetospinography provides a noninvasive and detailed visualization of neural currents. We previously reported that magnetospinography can be used to evaluate neural function in the lower lumbar spine in response to tibial, peroneal, and sciatic nerve stimulation. However, evaluating the neural function of the upper and middle lumbar spine is often difficult due to lower current intensity. We aimed to visualize the neural activity of the upper and middle lumbar spine using new stimulation methods and assess the foraminal current. Methods: Neural magnetic fields in 10 healthy volunteers were recorded after stimulation of the lateral femoral cutaneous nerve, saphenous nerve, femoral nerve, and peroneal nerve. The conduction velocity and current intensity in the spinal canal and intervertebral foramen were calculated and compared for each type of nerve stimulation. Results: Magnetospinography visualized the evoked magnetic fields in the lumbar region after each nerve stimulation method in all volunteers. The current intensity in the upper lumbar spine was significantly greater after femoral nerve stimulation. Magnetospinography revealed that action current flowed mainly along the L2 nerve root after lateral femoral cutaneous nerve stimulation and the L4 nerve root after saphenous nerve stimulation. Conclusions: Using a new stimulation method, magnetospinography enabled the noninvasive visualization of neural currents in the upper and middle lumbar spine. Femoral nerve stimulation is suitable for evaluating the spinal canal of the upper lumbar spine, and lateral femoral cutaneous nerve and saphenous nerve stimulations are suitable for evaluating the upper and middle lumbar intervertebral foramina, respectively.
- 16 October 2025
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 43 (4) , 332-339
Visualization of Neural Activity in the Upper and Middle Lumbar Spine Using Magnetospinography After Lateral Femoral Cutaneous, Saphenous, and Femoral Nerve Stimulation
Purpose: Magnetospinography provides a noninvasive and detailed visualization of neural currents. We previously reported that magnetospinography can be used to evaluate neural function in the lower lumbar spine in response to tibial, peroneal, and sciatic nerve stimulation. However, evaluating the neural function of the upper and middle lumbar spine is often difficult due to lower current intensity. We aimed to visualize the neural activity of the upper and middle lumbar spine using new stimulation methods and assess the foraminal current. Methods: Neural magnetic fields in 10 healthy volunteers were recorded after stimulation of the lateral femoral cutaneous nerve, saphenous nerve, femoral nerve, and peroneal nerve. The conduction velocity and current intensity in the spinal canal and intervertebral foramen were calculated and compared for each type of nerve stimulation. Results: Magnetospinography visualized the evoked magnetic fields in the lumbar region after each nerve stimulation method in all volunteers. The current intensity in the upper lumbar spine was significantly greater after femoral nerve stimulation. Magnetospinography revealed that action current flowed mainly along the L2 nerve root after lateral femoral cutaneous nerve stimulation and the L4 nerve root after saphenous nerve stimulation. Conclusions: Using a new stimulation method, magnetospinography enabled the noninvasive visualization of neural currents in the upper and middle lumbar spine. Femoral nerve stimulation is suitable for evaluating the spinal canal of the upper lumbar spine, and lateral femoral cutaneous nerve and saphenous nerve stimulations are suitable for evaluating the upper and middle lumbar intervertebral foramina, respectively.
- Open Access
- 3 July 2025
- Published by Oxford University Press (OUP) in Brain Communications
- Vol. 7 (4)
Magnetomyographic evaluation of motor unit size that is robust to changes in distance to sensor
In clinical practice, motor unit (MU) size is evaluated using needle electromyography to diagnose the cause of muscle weakness, whether myogenic or neurogenic. However, needle electromyography is influenced by the conductance of the muscle tissue and the distance from the MU to the electrode. In contrast, the magnetic field generated by a skeletal muscle is not distorted by subcutaneous tissues because their magnetic permeability is considered equal to that of free space. Therefore, we hypothesized that MU amplitude can be measured via magnetic field recordings. We tested this hypothesis by recording MU activity in the abductor pollicis brevis muscle. We then evaluated the MU size difference between healthy individuals and patients with spinal muscular atrophy and spinal-bulbar muscular atrophy. Furthermore, we assessed whether our method could consistently evaluate the MU size regardless of the sensor-muscle distance. Myomagnetic fields of single MUs evoked by electrical stimulation of the median nerve were measured. We used a biomagnetometer equipped with 132-channel superconducting quantum interference device sensors orientated upwards and arrayed on a quasi-planar surface. We applied a spatial filtering method that can estimate the current distribution from the magnetic field even for a conductor with unknown configuration or conductivity distribution and that does not require an a priori assumption of how many source currents are present. We visualized the electrical activity of 12 MUs of the abductor pollicis brevis muscle from eight healthy individuals and of two MUs from two patients with spinal muscular atrophy and spinal-bulbar muscular atrophy. Four current patterns were identified in the MU electrical activity. In all MUs, current towards the innervation zone was observed just after the start of activities. We called this current ‘initial muscle-directing current’. At the same time, currents directed proximally and distally from the middle of the muscle were observed in most MUs. Initial muscle-directing current was more than 3 or 10 times larger in patients with spinal muscular atrophy and spinal-bulbar muscular atrophy than in healthy individuals. Initial muscle-directing current was estimated to weaken by 5.5% for every 5-mm increase in distance from the sensor array. Initial muscle-directing current is considered to reflect the activity near the neuromuscular junction and can be an index of MU size. The results confirmed our hypothesis that MU amplitude can be evaluated using magnetic measurements. This novel and non-invasive magnetomyography method can evaluate MU size with little influence of distance and has the potential to supersede needle electromyography.
- 3 July 2025
- Published by Oxford University Press (OUP) in Brain Communications
- Vol. 7 (4)
Open AccessMagnetomyographic evaluation of motor unit size that is robust to changes in distance to sensor
In clinical practice, motor unit (MU) size is evaluated using needle electromyography to diagnose the cause of muscle weakness, whether myogenic or neurogenic. However, needle electromyography is influenced by the conductance of the muscle tissue and the distance from the MU to the electrode. In contrast, the magnetic field generated by a skeletal muscle is not distorted by subcutaneous tissues because their magnetic permeability is considered equal to that of free space. Therefore, we hypothesized that MU amplitude can be measured via magnetic field recordings. We tested this hypothesis by recording MU activity in the abductor pollicis brevis muscle. We then evaluated the MU size difference between healthy individuals and patients with spinal muscular atrophy and spinal-bulbar muscular atrophy. Furthermore, we assessed whether our method could consistently evaluate the MU size regardless of the sensor-muscle distance. Myomagnetic fields of single MUs evoked by electrical stimulation of the median nerve were measured. We used a biomagnetometer equipped with 132-channel superconducting quantum interference device sensors orientated upwards and arrayed on a quasi-planar surface. We applied a spatial filtering method that can estimate the current distribution from the magnetic field even for a conductor with unknown configuration or conductivity distribution and that does not require an a priori assumption of how many source currents are present. We visualized the electrical activity of 12 MUs of the abductor pollicis brevis muscle from eight healthy individuals and of two MUs from two patients with spinal muscular atrophy and spinal-bulbar muscular atrophy. Four current patterns were identified in the MU electrical activity. In all MUs, current towards the innervation zone was observed just after the start of activities. We called this current ‘initial muscle-directing current’. At the same time, currents directed proximally and distally from the middle of the muscle were observed in most MUs. Initial muscle-directing current was more than 3 or 10 times larger in patients with spinal muscular atrophy and spinal-bulbar muscular atrophy than in healthy individuals. Initial muscle-directing current was estimated to weaken by 5.5% for every 5-mm increase in distance from the sensor array. Initial muscle-directing current is considered to reflect the activity near the neuromuscular junction and can be an index of MU size. The results confirmed our hypothesis that MU amplitude can be evaluated using magnetic measurements. This novel and non-invasive magnetomyography method can evaluate MU size with little influence of distance and has the potential to supersede needle electromyography.
- 28 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (3) , 2614-2621
Reinforcement Learning of Flexible Policies for Symbolic Instructions With Adjustable Mapping Specifications
Symbolic task representation is a powerful tool for encoding human instructions and domain knowledge. Such instructions guide robots to accomplish diverse objectives and meet constraints through reinforcement learning (RL). Most existing methods are based on fixed mappings from environmental states to symbols. However, in inspection tasks, where equipment conditions must be evaluated from multiple perspectives to avoid errors of oversight, robots must fulfill the same symbol from different states. To help robots respond to flexible symbol mapping, we propose representing symbols and their mapping specifications separately within an RL policy. This approach imposes on RL policy to learn combinations of symbolic instructions and mapping specifications, requiring an efficient learning framework. To cope with this issue, we introduce an approach for learning flexible policies called Symbolic Instructions with Adjustable Mapping Specifications (SIAMS). This paper represents symbolic instructions using linear temporal logic (LTL), a formal language that can be easily integrated into RL. Our method addresses the diversified completion patterns of instructions by (1) a specification-aware state modulation, which embeds differences in mapping specifications in state features, and (2) a symbol-number-based task curriculum, which gradually provides tasks according to the learning's progress. Evaluations in 3D simulations with discrete and continuous action spaces demonstrate that our method outperforms context-aware multi-task RL comparisons.
- 28 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (3) , 2614-2621
Reinforcement Learning of Flexible Policies for Symbolic Instructions With Adjustable Mapping Specifications
Symbolic task representation is a powerful tool for encoding human instructions and domain knowledge. Such instructions guide robots to accomplish diverse objectives and meet constraints through reinforcement learning (RL). Most existing methods are based on fixed mappings from environmental states to symbols. However, in inspection tasks, where equipment conditions must be evaluated from multiple perspectives to avoid errors of oversight, robots must fulfill the same symbol from different states. To help robots respond to flexible symbol mapping, we propose representing symbols and their mapping specifications separately within an RL policy. This approach imposes on RL policy to learn combinations of symbolic instructions and mapping specifications, requiring an efficient learning framework. To cope with this issue, we introduce an approach for learning flexible policies called Symbolic Instructions with Adjustable Mapping Specifications (SIAMS). This paper represents symbolic instructions using linear temporal logic (LTL), a formal language that can be easily integrated into RL. Our method addresses the diversified completion patterns of instructions by (1) a specification-aware state modulation, which embeds differences in mapping specifications in state features, and (2) a symbol-number-based task curriculum, which gradually provides tasks according to the learning's progress. Evaluations in 3D simulations with discrete and continuous action spaces demonstrate that our method outperforms context-aware multi-task RL comparisons.
- 14 September 2024
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 64 (suppl 68) , OA4557
Intratracheal therapy using nintedanib amorphous particles in murine pulmonary fibrosis
Introduction: Nintedanib, an oral medicine for human progressive pulmonary fibrosis, still has several issues of concern, such as systemic adverse events (AEs) of liver dysfunction/diarrhea and low bioavailability. Aims and objectives: Inhalable nintedanib directly targeting the fibrotic lung is expected to prove more effective and tolerable than oral nintedanib. We thus investigated whether intratracheal (IT) nintedanib could attenuate the change in bleomycin-induced murine pulmonary fibrosis at relatively low doses compared to intraperitoneal (IP) nintedanib. Methods: Inhalable nintedanib was developed using fine droplet drying (FDD) technology (Ricoh Company, Ltd., Tokyo, Japan). FDD-nintedanib formed amorphous spherical solid dispersion particles 1–5 µm in size, showing over 10-times higher solubility compared to the original nintedanib crystals. In mouse experiments, IT or IP FDD-nintedanib solution was administered 48 h before bleomycin administration (day 1). The effect was evaluated by pulmonary function test (PFT), histological change, and amount of lung collagen on day 21. Results: Compared to mice pretreated with IP FDD-nintedanib even with the highest dose (120 µg/mouse) in a bleomycin-induced pulmonary fibrosis model, mice pretreated with IT FDD-nintedanib showed significant attenuation of: 1) PFT declines in compliance and static compliance in a dose-dependent manner (20–120 µg/mouse); 2) fibrinous exudation and cell proliferation; and 3) lung collagen content. No apparent AEs were seen. Conclusions: FDD-nintedanib IT significantly attenuated PFT declines, histological damage, and amount of lung collagen, with no apparent systemic/local AEs in a murine pulmonary fibrosis model.
- 14 September 2024
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 64 (suppl 68) , OA4557
Intratracheal therapy using nintedanib amorphous particles in murine pulmonary fibrosis
Introduction: Nintedanib, an oral medicine for human progressive pulmonary fibrosis, still has several issues of concern, such as systemic adverse events (AEs) of liver dysfunction/diarrhea and low bioavailability. Aims and objectives: Inhalable nintedanib directly targeting the fibrotic lung is expected to prove more effective and tolerable than oral nintedanib. We thus investigated whether intratracheal (IT) nintedanib could attenuate the change in bleomycin-induced murine pulmonary fibrosis at relatively low doses compared to intraperitoneal (IP) nintedanib. Methods: Inhalable nintedanib was developed using fine droplet drying (FDD) technology (Ricoh Company, Ltd., Tokyo, Japan). FDD-nintedanib formed amorphous spherical solid dispersion particles 1–5 µm in size, showing over 10-times higher solubility compared to the original nintedanib crystals. In mouse experiments, IT or IP FDD-nintedanib solution was administered 48 h before bleomycin administration (day 1). The effect was evaluated by pulmonary function test (PFT), histological change, and amount of lung collagen on day 21. Results: Compared to mice pretreated with IP FDD-nintedanib even with the highest dose (120 µg/mouse) in a bleomycin-induced pulmonary fibrosis model, mice pretreated with IT FDD-nintedanib showed significant attenuation of: 1) PFT declines in compliance and static compliance in a dose-dependent manner (20–120 µg/mouse); 2) fibrinous exudation and cell proliferation; and 3) lung collagen content. No apparent AEs were seen. Conclusions: FDD-nintedanib IT significantly attenuated PFT declines, histological damage, and amount of lung collagen, with no apparent systemic/local AEs in a murine pulmonary fibrosis model.
- Open Access
- 15 June 2024
- Published by Wiley in Cancer Science
- Vol. 115 (8) , 2686-2700
Alternative magnetic field exposure suppresses tumor growth via metabolic reprogramming
Application of physical forces, ranging from ultrasound to electric fields, is recommended in various clinical practice guidelines, including those for treating cancers and bone fractures. However, the mechanistic details of such treatments are often inadequately understood, primarily due to the absence of comprehensive study models. In this study, we demonstrate that an alternating magnetic field (AMF) inherently possesses a direct anti‐cancer effect by enhancing oxidative phosphorylation (OXPHOS) and thereby inducing metabolic reprogramming. We observed that the proliferation of human glioblastoma multiforme (GBM) cells (U87 and LN229) was inhibited upon exposure to AMF within a specific narrow frequency range, including around 227 kHz. In contrast, this exposure did not affect normal human astrocytes (NHA). Additionally, in mouse models implanted with human GBM cells in the brain, daily exposure to AMF for 30 min over 21 days significantly suppressed tumor growth and prolonged overall survival. This effect was associated with heightened reactive oxygen species (ROS) production and increased manganese superoxide dismutase (MnSOD) expression. The anti‐cancer efficacy of AMF was diminished by either a mitochondrial complex IV inhibitor or a ROS scavenger. Along with these observations, there was a decrease in the extracellular acidification rate (ECAR) and an increase in the oxygen consumption rate (OCR). This suggests that AMF‐induced metabolic reprogramming occurs in GBM cells but not in normal cells. Our results suggest that AMF exposure may offer a straightforward strategy to inhibit cancer cell growth by leveraging oxidative stress through metabolic reprogramming.
- 15 June 2024
- Published by Wiley in Cancer Science
- Vol. 115 (8) , 2686-2700
Open AccessAlternative magnetic field exposure suppresses tumor growth via metabolic reprogramming
Application of physical forces, ranging from ultrasound to electric fields, is recommended in various clinical practice guidelines, including those for treating cancers and bone fractures. However, the mechanistic details of such treatments are often inadequately understood, primarily due to the absence of comprehensive study models. In this study, we demonstrate that an alternating magnetic field (AMF) inherently possesses a direct anti‐cancer effect by enhancing oxidative phosphorylation (OXPHOS) and thereby inducing metabolic reprogramming. We observed that the proliferation of human glioblastoma multiforme (GBM) cells (U87 and LN229) was inhibited upon exposure to AMF within a specific narrow frequency range, including around 227 kHz. In contrast, this exposure did not affect normal human astrocytes (NHA). Additionally, in mouse models implanted with human GBM cells in the brain, daily exposure to AMF for 30 min over 21 days significantly suppressed tumor growth and prolonged overall survival. This effect was associated with heightened reactive oxygen species (ROS) production and increased manganese superoxide dismutase (MnSOD) expression. The anti‐cancer efficacy of AMF was diminished by either a mitochondrial complex IV inhibitor or a ROS scavenger. Along with these observations, there was a decrease in the extracellular acidification rate (ECAR) and an increase in the oxygen consumption rate (OCR). This suggests that AMF‐induced metabolic reprogramming occurs in GBM cells but not in normal cells. Our results suggest that AMF exposure may offer a straightforward strategy to inhibit cancer cell growth by leveraging oxidative stress through metabolic reprogramming.