    Feasibility of Noninvasive Atrial and Ventricular Activation, Conduction-Velocity, and Site-of-Origin Mapping with Solid-State Magnetocardiography: A Preclinical Validation Study

    by Kelly A. Brennan, Sabyasachi Bandyopadhyay, Charles Sillett, Jennifer K. Lyons, Makoto Kameno, Yasushi Terazono, Prasanth Ganesan, Xichong Liu, Gentaro Ikeda, Hiroyuki Takashima, et al.

    Background: Characterizing cardiac activation by its site of origin, propagation, and conduction velocity underlies arrhythmia diagnosis and management, but invasive electrophysiology (EP) mapping requires vascular access, fluoroscopy, and sedation. Magnetocardiography (MCG) enables contactless mapping, and recent solid-state sensors remove the cost, cryogenic, and shielding barriers of legacy systems. We assessed the feasibility of a novel solid-state MCG system for noninvasive arrhythmia site-of-origin (SOO) localization and activation reconstruction, benchmarked against electrocardiographic imaging (ECGi). Methods: In nine swine implanted with right atrial and right ventricular pacing leads, we recorded MCG and ECGi simultaneously during atrial and ventricular pacing. Invasive epicardial contact EP mapping provided the activation-time reference and MRI-derived lead-tip location the SOO reference. Local activation time (LAT), conduction velocity (CV), and SOO were compared on a co-registered chamber mesh. SOO error was the Euclidean distance to the MRI lead tip; LAT and CV agreement with EP were quantified by Pearson r and compared using Wilcoxon signed-rank tests. Results: Across 17 datasets (8 atrial, 9 ventricular), median SOO error was lower for MCG than ECGi in the atrium (19.6 vs 31.2 mm; p=0.023) and ventricle (12.0 vs 26.1 mm; p=0.074). LAT agreement with EP was comparable between modalities and higher in the ventricle (MCG r=0.63; ECGi r=0.68) compared with the atrium (MCG r=0.40; ECGi r=0.53), each correlating with invasive EP mapping above chance. CV agreement was modest and numerically higher for MCG in the ventricle. Conclusions: Solid-state MCG was feasible for noninvasive site-of-origin localization and activation mapping, with accuracy comparable to ECGi, motivating larger prospective studies to define its clinical role in noninvasive mapping. Clinical Perspective: What Is Known: Invasive electrophysiology mapping is the reference standard for localizing the arrhythmia site of origin and characterizing cardiac activation, but it requires vascular access, fluoroscopy, and prolonged sedation within the electrophysiology laboratory. Existing noninvasive options have important limitations: electrocardiographic imaging depends on concomitant thoracic imaging, size-dependent vest fit, and torso-conductivity modeling, while legacy magnetocardiography has required costly cryogenic and magnetically shielded infrastructure. What the Study Adds: In a preclinical large-mammal model referenced to invasive electrophysiology and MRI, a novel contactless solid-state magnetocardiography system feasibly localized atrial and ventricular sites of origin and reconstructed activation without body-surface electrodes. Magnetocardiography localized the site of origin more accurately than ECGi in the atrium, and showed numerically lower localization error in the ventricle. Magnetocardiography displayed activation-time and conduction-velocity agreement with invasive electrophysiology comparable to electrocardiographic imaging in both chambers. Solid-state magnetocardiography may offer a scalable, noninvasive approach for preprocedural localization and complementary activation mapping, motivating larger prospective clinical validation.

  • 36‐4: Direct Retinal Projection by Meta‐Optic Mirror for Smart Glasses

    by Tomohito Mizuno, Tetsuya Shibata, Takeshi Nojiri, Takekazu Yamane, Yoji Nakamura, Shigeaki Tanaka, Yoichiro Tanaka, Takehiro Onomatsu, Kazushi Nishiyama, Tetsuya Mino, et al.

    Direct retinal projection (DRP) of focus‐free feature is a strong candidate for the realization of smart glasses, which provide an ultracompact, stylish, and ultralow power consumption display. However, the free‐form surface reflective mirror in front of the eyes for DRP is an obstacle to usability, and integration in lens is required. In this study, a meta‐optic mirror for a 1,280 × 720 resolution and diagonal FoV of 45° was successfully embedded in a lens. The structure was a trapezoidal pattern of Al 2 O 3 3 nm/Ag 40 nm/SiO 2 50 nm on a sapphire substrate. Given that DRP image can be observed regardless of eyesight, a meta‐optic mirror can be simply embedded in prescription lens without adding lens to see virtual image.

  • Open Access

    Demonstration of a subthreshold analog CMOS reservoir chip for temporal signal processing

    by Shimon Matsuno, Abe Yuki, Kota Ando, Kazuki Nakada, Eiji Suzuki, Keita Suda, Yukihiro Urakawa, Shin-Ichiro Mochizuki, Yukio Terasaki, Tomoyuki Sasaki, et al.

    We present a low-power analog CMOS reservoir computing chip that employs a simple ring topology for unidirectional nonlinear analog processing. Each node integrates a sample-and-hold circuit operating at 1 kHz, enabling compact and energy-efficient implementation in standard CMOS. The fabricated chip was evaluated on standard benchmarks, achieving a linear memory capacity of 13.4 and information processing capacities of 7.2 (second-order), 3.3 (third-order), and 1.2 (fourth-order). It also demonstrated competitive accuracy in both short- and long-term time-series forecasting tasks. Most notably, this performance was achieved with a power dissipation of only 20 μ W per core, highlighting the potential of analog CMOS reservoir computing for deployment in energy-constrained edge devices.


  • Synthesis of Silica-Coated Iron (Fe@SiO x ) Particles with High Stability and Fast Magnetic Responsiveness

    by Eka Lutfi Septiani, Nobuhiro Okuda, Tomoyuki Hirano, Kiet Le Anh Cao, Hang Thi Nguyet Le, Hiroyuki Matsumoto, Takashi Ogi


  • Open Access

    Induction of large in-plane uniaxial magnetic anisotropy for Co–Fe–B–Pt thin films by magnetic field annealing

    by Takumi Yamazaki, Yugo Ishitani, Katsuyuki Nakada, Tomoyuki Sasaki, Yasushi Endo, Koki Takanashi, Takeshi Seki

    We report the induction of large in-plane uniaxial magnetic anisotropy for the CoFeB-based thin films by post-annealing under the magnetic field application. The comprehensive study reveals the influence of CoFeB composition and Pt addition to CoFeB on the induced magnetic anisotropy by magnetic field annealing. The addition of Pt to a CoFeB film significantly enhances the effect of magnetic field annealing, and as a result, the CoFeB–Pt films exhibit the in-plane uniaxial magnetic anisotropy energies that are one order of magnitude larger than the pristine CoFeB films. In order to understand the mechanism of magnetic anisotropy induction by post-annealing, we carried out the magnetostriction measurement for the CoFeB-based thin films. The correlation between the induced magnetic anisotropy and magnetoelastic properties is discussed.


  • Formation of two distinct magnetic fixed parts and a domain-wall layer etched from a continuous film for bottom-pinned-type spin-memristors

    by Shogo Yamada, Toshiki Gushi, Shinto Ichikawa, Tatsuo Shibata, Tomoyuki Sasaki

    Spin-memristors are promising candidates for use as artificial synapses in analog neuromorphic devices, owing to their conductance response, nonvolatility, high speed, and high endurance. These properties offer significant potential for realizing low-power-consumption artificial-intelligence systems. This study employed Ar-ion etching to fabricate two distinct fixed magnetic parts with opposing magnetization directions, along with a domain-wall (DW) layer, from a continuous synthetic antiferromagnetic film. Consequently, single-DW formation was achieved through a simple magnetic-field operation, together with current-induced DW motion. These findings highlight the potential of bottom-pinned spin-memristors to simplify the fabrication process for practical applications.

  • An EMI Filter for a Wide-Bandgap Traction Inverter: From the SPICE Model to its Characterization

    by Maurizio Tranchero, Paolo Santero, Christian Paulwitz, Stefan Weber

    Designing and optimizing an electromagnetic interference filter for a traction inverter can be a very time-consuming activity, due to the complexity of the task and the fact that it is typically addressed at the end of the inverter development, when the first samples are validated in the anechoic chamber. This paper proposes a simplified modeling approach aimed at anticipating the filter design and sizing in the early phase of the inverter design, making the full development more integrated. The designed filter is then characterized using the VNA and finally its effectiveness is tested by performing compliance tests in an anechoic chamber.


  • Growth and properties of epitaxial (Bi, K)TiO3-Bi(Mg, Ti)O3-BiFeO3 piezoelectric films prepared by using a PLD method

    by Junpei Morishita, Shintaro Yoshimura, Hiroyuki Ono, Yusuke Sato

    Epitaxial films of (1.0 − x)((Bi0.5, K0.5)TiO3-Bi(Mg0.5, Ti0.5)O3)-xBiFeO3 (BKT-BMT-BFO) on silicon substrates were fabricated by using a pulsed laser deposition method, and their structures and piezoelectric properties were evaluated. The epitaxial relationship was (100) 〈100〉BKT-BMT-BFO//(100) 〈100〉Pt//(100) 〈100〉yttria-stabilized ZrO2//(100) 〈001〉Si. The BKT-BMT-BFO film with x = 0.5 exhibited a tetragonal structure with a large lattice anisotropic parameter (c/a), reaching a maximum value of 1.095 on LaNiO3 buffer layer, due to a substrate-induced epitaxial strain and tetragonal BiFeO3. It showed high ferroelectricity with remanent polarization (P r) even reaching 90 μC cm−2. The transverse piezoelectric coefficient (|e 31,f |) and figure of merit (e 31, f 2/(ε 0 ε r)) of the BKT-BMT-BFO films were up to 7.4 C cm−2 and 60.7 GPa, respectively.


  • Open Access

    Recording of Cardiac Excitation Using a Novel Magnetocardiography System with Magnetoresistive Sensors Outside a Magnetic Shielded Room

    by Leo Yaga, Miki Amemiya, Yu Natsume, Tomohiko Shibuya, Tetsuo Sasano

    Magnetocardiography (MCG) provides a non-invasive, contactless technique for evaluating the magnetic fields generated by cardiac electrical activity, offering unique spatial insights into cardiac electrophysiology. However, conventional MCG systems depend on superconducting quantum interference devices that require cryogenic cooling and magnetic shielded environments, posing considerable impediments to widespread clinical adoption. In this study, we present a novel MCG system utilizing a high-sensitivity, wide-dynamic-range magnetoresistive sensor array operating at room temperature. To mitigate environmental interference, identical sensors were deployed as reference channels, enabling adaptive noise cancellation (ANC) without the need for traditional magnetic shielding. MCG recordings were obtained from 40 healthy participants, with signals processed using ANC, R-peak-synchronized averaging, and Bayesian spatial signal separation. This approach enabled the reliable detection of key cardiac components, including P, QRS, and T waves, from the unshielded MCG recordings. Our findings underscore the feasibility of a cost-effective, portable MCG system suitable for clinical settings, presenting new opportunities for noninvasive cardiac diagnostics and monitoring.