Kobayasi Institute of Physical Research
Type
FacilityLocations
Tokyo, JapanLatest Publications
- 11 November 2026
- Published by Institute of Noise Control Engineering (INCE) in INTER-NOISE and NOISE-CON Congress and Conference Proceedings
- Vol. 274 (5) , 163-172
Research Study on the Acoustic Performance Associated with Deformation of metal noise insulation plate
NEXCO is studying the aging of noise barriers and the renewal criteria for the purpose of renewal planning. This report focuses on the metal noise insulation plates (metal panels), which are the main component for noise barriers, and studies the degradation of acoustic performance due to aging. 1) It was confirmed that the acoustic performance satisfies the initial performance standard even after 40 years if the appearance of the metal panel is relatively good. It was shown that the secular change in the acoustic performance of the metal panel can be evaluated by investigating the appearance and the like based on the maintenance inspection procedure prescribed by NEXCO 2). Furthermore, the extent of the damage was assumed, and the impact on acoustic performance was examined through indoor tests to determine at what level of damage replacement of the metal panels would be necessary. As a result, it was found that if the back plate of noise barrier is damaged to some extent, it could potentially affect acoustic performance. It was also confirmed that temporarily applying an aluminum tape to the damaged area can restore satisfactory acoustic performance.
- 11 November 2026
- Published by Institute of Noise Control Engineering (INCE) in INTER-NOISE and NOISE-CON Congress and Conference Proceedings
- Vol. 274 (5) , 163-172
Research Study on the Acoustic Performance Associated with Deformation of metal noise insulation plate
NEXCO is studying the aging of noise barriers and the renewal criteria for the purpose of renewal planning. This report focuses on the metal noise insulation plates (metal panels), which are the main component for noise barriers, and studies the degradation of acoustic performance due to aging. 1) It was confirmed that the acoustic performance satisfies the initial performance standard even after 40 years if the appearance of the metal panel is relatively good. It was shown that the secular change in the acoustic performance of the metal panel can be evaluated by investigating the appearance and the like based on the maintenance inspection procedure prescribed by NEXCO 2). Furthermore, the extent of the damage was assumed, and the impact on acoustic performance was examined through indoor tests to determine at what level of damage replacement of the metal panels would be necessary. As a result, it was found that if the back plate of noise barrier is damaged to some extent, it could potentially affect acoustic performance. It was also confirmed that temporarily applying an aluminum tape to the damaged area can restore satisfactory acoustic performance.
- Open Access
- 30 August 2026
- Published by Japan Audiological Society in AUDIOLOGY JAPAN
- Vol. 69 (4) , 168-175
A simplified method for measuring earplug sound attenuation using an audiometer
要旨: 騒音職場において, 耳栓は一般的な騒音対策であるが, 装着状態により遮音効果は大きく変動するため, 個人ごとの遮音効果を評価する必要がある。本研究では, 労働衛生の現場で使用されるオージオメータを用いた耳栓遮音効果測定法を提案し, その妥当性を JIS T 8161-1 に準拠した測定法 (基準法) との比較により検討した。健聴者16名にフォーム型耳栓および成形型耳栓の2種類をそれぞれ装着させ, 6周波数の遮音値を測定し, 基準法との差分を解析した。等価性検定 (TOST, ±6dB) の結果, 周波数別では 250Hz において等価性は確認されなかったが, 500Hz 以上では等価性が確認された。また, 全周波数における差分の平均については等価性が確認された。以上より, 本提案法は平均的な遮音効果の評価において基準法と同等の結果が得られ, 現場における耳栓の遮音効果を実用的に評価できる可能性が示唆された。
- 30 August 2026
- Published by Japan Audiological Society in AUDIOLOGY JAPAN
- Vol. 69 (4) , 168-175
Open AccessA simplified method for measuring earplug sound attenuation using an audiometer
要旨: 騒音職場において, 耳栓は一般的な騒音対策であるが, 装着状態により遮音効果は大きく変動するため, 個人ごとの遮音効果を評価する必要がある。本研究では, 労働衛生の現場で使用されるオージオメータを用いた耳栓遮音効果測定法を提案し, その妥当性を JIS T 8161-1 に準拠した測定法 (基準法) との比較により検討した。健聴者16名にフォーム型耳栓および成形型耳栓の2種類をそれぞれ装着させ, 6周波数の遮音値を測定し, 基準法との差分を解析した。等価性検定 (TOST, ±6dB) の結果, 周波数別では 250Hz において等価性は確認されなかったが, 500Hz 以上では等価性が確認された。また, 全周波数における差分の平均については等価性が確認された。以上より, 本提案法は平均的な遮音効果の評価において基準法と同等の結果が得られ, 現場における耳栓の遮音効果を実用的に評価できる可能性が示唆された。
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Sensitivity Change in the Electret Condenser Microphone with Long-Term Preservation
In electrostatic transducers, electrets may be applied either to the diaphragm or to the fixed electrode. This paper evaluates changes in the sensitivity frequency characteristics of diaphragm electret condenser microphone samples manufactured in 1976 using two different charging methods, namely electron beam and corona discharge. After fabrication, the samples are subjected to three types of accelerated aging tests: a high-temperature test (70°C for 1,000 h), a humidity test (60°C, 95% relative humidity), and a low-temperature test (−25°C for 1,000 h), and are then stored in a laboratory desiccator. The high reliability of the diaphragm electret condenser microphone is confirmed, with almost no sensitivity degradation observed after approximately 50 years of laboratory storage. Furthermore, analysis of the factors governing sensitivity changes reveals that the sensitivity remains nearly unchanged over this period because a decrease in diaphragm stiffness compensates for the deterioration of the electret surface potential. In the future, once the stiffness of the diaphragm becomes relatively stable, deterioration of the electret surface potential is expected to become the primary cause of the sensitivity degradation.
- 13 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Sensitivity Change in the Electret Condenser Microphone with Long-Term Preservation
In electrostatic transducers, electrets may be applied either to the diaphragm or to the fixed electrode. This paper evaluates changes in the sensitivity frequency characteristics of diaphragm electret condenser microphone samples manufactured in 1976 using two different charging methods, namely electron beam and corona discharge. After fabrication, the samples are subjected to three types of accelerated aging tests: a high-temperature test (70°C for 1,000 h), a humidity test (60°C, 95% relative humidity), and a low-temperature test (−25°C for 1,000 h), and are then stored in a laboratory desiccator. The high reliability of the diaphragm electret condenser microphone is confirmed, with almost no sensitivity degradation observed after approximately 50 years of laboratory storage. Furthermore, analysis of the factors governing sensitivity changes reveals that the sensitivity remains nearly unchanged over this period because a decrease in diaphragm stiffness compensates for the deterioration of the electret surface potential. In the future, once the stiffness of the diaphragm becomes relatively stable, deterioration of the electret surface potential is expected to become the primary cause of the sensitivity degradation.
- 7 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Surface Potential of a Carnauba Wax Electret 100 Years after Fabrication
Dr. Mototaro Eguchi first reported the fabrication of carnauba wax electrets in 1919. The 1924 prototype and documents on the manufacturing conditions were exhibited at Japan’s National Museum of Nature and Science. In 1969, Dr. Toshiaki Takamatsu of the RIKEN Institute conducted re-measurements and follow-up tests on the prototype. The same specimen, now preserved at Tsukuba Research Departments of National Museum of Nature and Science, was re-examined 100 years after its fabrication (in 2024) to assess temporal changes in its electret properties. The results confirmed that the charge density had decreased to approximately 1/12–1/18 of its original value, representing about a 20% decline compared with Takamatsu’s measurements recorded 55 years earlier.
- 7 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Surface Potential of a Carnauba Wax Electret 100 Years after Fabrication
Dr. Mototaro Eguchi first reported the fabrication of carnauba wax electrets in 1919. The 1924 prototype and documents on the manufacturing conditions were exhibited at Japan’s National Museum of Nature and Science. In 1969, Dr. Toshiaki Takamatsu of the RIKEN Institute conducted re-measurements and follow-up tests on the prototype. The same specimen, now preserved at Tsukuba Research Departments of National Museum of Nature and Science, was re-examined 100 years after its fabrication (in 2024) to assess temporal changes in its electret properties. The results confirmed that the charge density had decreased to approximately 1/12–1/18 of its original value, representing about a 20% decline compared with Takamatsu’s measurements recorded 55 years earlier.
- Open Access
- 10 March 2026
- Published by Wiley in Advanced Materials Technologies
- Vol. 11 (21)
Skin‐Like Tri‐Modal Sensors Based on Soft Piezoelectric and Ionic Composites
Human skin perceives complex external stimuli through the coordinated detection of temperature, static strain, and dynamic strain. However, current skin‐like multimodal sensors are typically limited to dual‐mode sensing or suffer from signal interference and excessive wirings. In this study, a soft, skin‐like tri‐modal sensor capable of independent and simultaneous detection of temperature, static strain, and dynamic strain is reported. The sensor consists of a single, skin‐inspired sensing layer of a soft, piezoelectric and ionic composite film that is sandwiched between stretchable electrodes. It uses distinct frequency‐domain responses: charge relaxation time for temperature, normalized capacitance for static strain, and piezoelectric charge output for dynamic strain—to fully decouple signals without the need for separate sensors. Practical demonstrations include simultaneous detection of skin temperature and pulse waves at the wrist, localized mapping of strain and temperature under shear stress, and texture recognition through dynamic force sensing. This work provides a compact and scalable platform for fully decoupled tri‐modal sensing, paving the way for intelligent prosthetics, on‐skin electronics, and interactive robotics.
- 10 March 2026
- Published by Wiley in Advanced Materials Technologies
- Vol. 11 (21)
Open AccessSkin‐Like Tri‐Modal Sensors Based on Soft Piezoelectric and Ionic Composites
Human skin perceives complex external stimuli through the coordinated detection of temperature, static strain, and dynamic strain. However, current skin‐like multimodal sensors are typically limited to dual‐mode sensing or suffer from signal interference and excessive wirings. In this study, a soft, skin‐like tri‐modal sensor capable of independent and simultaneous detection of temperature, static strain, and dynamic strain is reported. The sensor consists of a single, skin‐inspired sensing layer of a soft, piezoelectric and ionic composite film that is sandwiched between stretchable electrodes. It uses distinct frequency‐domain responses: charge relaxation time for temperature, normalized capacitance for static strain, and piezoelectric charge output for dynamic strain—to fully decouple signals without the need for separate sensors. Practical demonstrations include simultaneous detection of skin temperature and pulse waves at the wrist, localized mapping of strain and temperature under shear stress, and texture recognition through dynamic force sensing. This work provides a compact and scalable platform for fully decoupled tri‐modal sensing, paving the way for intelligent prosthetics, on‐skin electronics, and interactive robotics.
- Open Access
- 1 March 2026
- Published by Acoustical Society of Japan in Acoustical Science and Technology
- Vol. 47 (2) , 184-187
Cartridge-type cellular polypropylene microphone with broadband sensitivity
A cellular polypropylene film metallized with gold electrodes is directly glued to the back plate of a commercially available condenser microphone cartridge whose metallic diaphragm is removed, composed of a microphone set with an existing pre-amplifier and power module. Lack of vibration resonance of the diaphragm makes it possible to widen frequency ranges in pressure sensitivity compared with those of commonly used condenser microphones. In fact, it has been experimentally verified that the prototyped microphone has good response to sound waves over the extremely wide range of frequencies from 200 Hz to 400 kHz and is highly acceptable to intense sound pressures of up to several tens of kilo-pascals.
- 1 March 2026
- Published by Acoustical Society of Japan in Acoustical Science and Technology
- Vol. 47 (2) , 184-187
Open AccessCartridge-type cellular polypropylene microphone with broadband sensitivity
A cellular polypropylene film metallized with gold electrodes is directly glued to the back plate of a commercially available condenser microphone cartridge whose metallic diaphragm is removed, composed of a microphone set with an existing pre-amplifier and power module. Lack of vibration resonance of the diaphragm makes it possible to widen frequency ranges in pressure sensitivity compared with those of commonly used condenser microphones. In fact, it has been experimentally verified that the prototyped microphone has good response to sound waves over the extremely wide range of frequencies from 200 Hz to 400 kHz and is highly acceptable to intense sound pressures of up to several tens of kilo-pascals.
- Open Access
- 19 December 2025
- Published by Elsevier in Intestinal Failure
- Vol. 9, 100344
Proof of principle study for the development of the world’s smallest long-term short bowel syndrome pig model using microminipigs
- 19 December 2025
- Published by Elsevier in Intestinal Failure
- Vol. 9, 100344
Open AccessProof of principle study for the development of the world’s smallest long-term short bowel syndrome pig model using microminipigs
- 22 October 2025
- Published by Institute of Noise Control Engineering (INCE) in INTER-NOISE and NOISE-CON Congress and Conference Proceedings
- Vol. 272 (2) , 2924-2932
Successive surveys of noise sensitivity (WNS-6B) in university students.
This research's research question is: Does noise sensitivity fluctuate? . As a first, preliminary attempt, we asked university students to answer questions about their noise sensitivity in class over the course of a week for two years from 2022. We used the WNS-6B questionnaire. As a result, we found that the noise sensitivity of university students fluctuates. In particular, we found that the fluctuation was large in the high-sensitivity group of students. At the same time, we conducted a survey using a questionnaire to measure the satisfaction of students' lives. We are examining the factors that cause fluctuations in noise sensitivity from various perspectives.
- 22 October 2025
- Published by Institute of Noise Control Engineering (INCE) in INTER-NOISE and NOISE-CON Congress and Conference Proceedings
- Vol. 272 (2) , 2924-2932
Successive surveys of noise sensitivity (WNS-6B) in university students.
This research's research question is: Does noise sensitivity fluctuate? . As a first, preliminary attempt, we asked university students to answer questions about their noise sensitivity in class over the course of a week for two years from 2022. We used the WNS-6B questionnaire. As a result, we found that the noise sensitivity of university students fluctuates. In particular, we found that the fluctuation was large in the high-sensitivity group of students. At the same time, we conducted a survey using a questionnaire to measure the satisfaction of students' lives. We are examining the factors that cause fluctuations in noise sensitivity from various perspectives.
- 22 October 2025
- Published by Institute of Noise Control Engineering (INCE) in INTER-NOISE and NOISE-CON Congress and Conference Proceedings
- Vol. 272 (4) , 955-962
Simple identification method of wind noise using wind speed difference generated inside wind screen
We devised a method for monitoring low-frequency sound which can identify wind noise and estimate the direction of the sound source. It is well known that measuring low-frequency sound outdoors can be difficult, as wind noise may interfere with the data. Therefore, we developed two different identification methods and produced prototypes to verify their performance. In the first method, we placed two microphones in a two-stage cylindrical wind screen with different diameters. This device can automatically identify wind noise by using the differences in wind speed within the wind screen. However, since this device consists of only two microphones, it cannot identify the direction of the sound source. In the other method, we placed three microphones in a single-stage cylindrical wind screen. This device can not only identify wind noise but also estimate the direction of the sound source. In this report, we introduce the mechanisms of both methods and present examples of actual monitoring measurements.
- 22 October 2025
- Published by Institute of Noise Control Engineering (INCE) in INTER-NOISE and NOISE-CON Congress and Conference Proceedings
- Vol. 272 (4) , 955-962
Simple identification method of wind noise using wind speed difference generated inside wind screen
We devised a method for monitoring low-frequency sound which can identify wind noise and estimate the direction of the sound source. It is well known that measuring low-frequency sound outdoors can be difficult, as wind noise may interfere with the data. Therefore, we developed two different identification methods and produced prototypes to verify their performance. In the first method, we placed two microphones in a two-stage cylindrical wind screen with different diameters. This device can automatically identify wind noise by using the differences in wind speed within the wind screen. However, since this device consists of only two microphones, it cannot identify the direction of the sound source. In the other method, we placed three microphones in a single-stage cylindrical wind screen. This device can not only identify wind noise but also estimate the direction of the sound source. In this report, we introduce the mechanisms of both methods and present examples of actual monitoring measurements.
- 22 October 2025
- Published by Institute of Noise Control Engineering (INCE) in INTER-NOISE and NOISE-CON Congress and Conference Proceedings
- Vol. 272 (4) , 963-970
Experimental study on outdoor sound propagation over rice fields
In rice fields, which cover large areas in Japan, the ground condition changes with the season depending on the cultivation condition. To investigate the variation in sound propagation characteristics in rice fields, a series of sound propagation experiments were carried out in a flat rice field area in different seasons. The impulse responses were measured at receiving points arranged in two opposing directions along the straight line in a range of 600 m from sound sources. The acoustic property of the ground surface was evaluated by estimating the effective flow resistivity of the ground by curve fitting between the excess attenuation characteristics determined from the measured impulse responses at short distant receiving points and the calculation results applying Miki's impedance model. It was estimated to be about 20,000 kPa s/m2 in the condition immediately after rice planting and less than 300 kPa s/m2 after rice harvesting, and it was confirmed that the acoustic property greatly changed by the season. It was also confirmed that excess attenuation at distant points varies by more than 20 dB at the same propagation distance by the difference in the sound propagation direction even in the same season due to wind effects.
- 22 October 2025
- Published by Institute of Noise Control Engineering (INCE) in INTER-NOISE and NOISE-CON Congress and Conference Proceedings
- Vol. 272 (4) , 963-970
Experimental study on outdoor sound propagation over rice fields
In rice fields, which cover large areas in Japan, the ground condition changes with the season depending on the cultivation condition. To investigate the variation in sound propagation characteristics in rice fields, a series of sound propagation experiments were carried out in a flat rice field area in different seasons. The impulse responses were measured at receiving points arranged in two opposing directions along the straight line in a range of 600 m from sound sources. The acoustic property of the ground surface was evaluated by estimating the effective flow resistivity of the ground by curve fitting between the excess attenuation characteristics determined from the measured impulse responses at short distant receiving points and the calculation results applying Miki's impedance model. It was estimated to be about 20,000 kPa s/m2 in the condition immediately after rice planting and less than 300 kPa s/m2 after rice harvesting, and it was confirmed that the acoustic property greatly changed by the season. It was also confirmed that excess attenuation at distant points varies by more than 20 dB at the same propagation distance by the difference in the sound propagation direction even in the same season due to wind effects.