International Financial Cryptography Association
Type
OtherLocations
Amsterdam, NetherlandsLatest Publications
- 9 August 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (17) , 7036-7055
Is the PTW 60019 microDiamond a suitable candidate for small field reference dosimetry?
A systematic study of the PTW microDiamond (MD) output factors (OF) is reported, aimed at clarifying its response in small fields and investigating its suitability for small field reference dosimetry. Ten MDs were calibrated under 60 Co irradiation. OF measurements were performed in 6 MV photon beams by a CyberKnife M6, a Varian DHX and an Elekta Synergy linacs. Two PTW silicon diodes E (Si-D) were used for comparison. The results obtained by the MDs were evaluated in terms of absorbed dose to water determination in reference conditions and OF measurements, and compared to the results reported in the recent literature. To this purpose, the Monte Carlo (MC) beam-quality correction factor, k Q M D , was calculated for the MD, and the small field output correction factors, k Q c l i n , Q m s r f c l i n , f m s r , were calculated for both the MD and the Si-D by two different research groups. An empirical function was also derived, providing output correction factors within 0.5% from the MC values calculated for all of the three linacs. A high reproducibility of the dosimetric properties was observed among the ten MDs. The experimental k Q M D values are in agreement within 1% with the MC calculated ones. Output correction factors within +0.7% and −1.4% were obtained down to field sizes as narrow as 5 mm. The resulting MD and Si-D field factors are in agreement within 0.2% in the case of CyberKnife measurements and 1.6% in the other cases. This latter higher spread of the data was demonstrated to be due to a lower reproducibility of small beam sizes defined by jaws or multi leaf collimators. The results of the present study demonstrate the reproducibility of the MD response and provide a validation of the MC modelling of this device. In principle, accurate reference dosimetry is thus feasible by using the microDiamond dosimeter for field sizes down to 5 mm.
- 9 August 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (17) , 7036-7055
Is the PTW 60019 microDiamond a suitable candidate for small field reference dosimetry?
A systematic study of the PTW microDiamond (MD) output factors (OF) is reported, aimed at clarifying its response in small fields and investigating its suitability for small field reference dosimetry. Ten MDs were calibrated under 60 Co irradiation. OF measurements were performed in 6 MV photon beams by a CyberKnife M6, a Varian DHX and an Elekta Synergy linacs. Two PTW silicon diodes E (Si-D) were used for comparison. The results obtained by the MDs were evaluated in terms of absorbed dose to water determination in reference conditions and OF measurements, and compared to the results reported in the recent literature. To this purpose, the Monte Carlo (MC) beam-quality correction factor, k Q M D , was calculated for the MD, and the small field output correction factors, k Q c l i n , Q m s r f c l i n , f m s r , were calculated for both the MD and the Si-D by two different research groups. An empirical function was also derived, providing output correction factors within 0.5% from the MC values calculated for all of the three linacs. A high reproducibility of the dosimetric properties was observed among the ten MDs. The experimental k Q M D values are in agreement within 1% with the MC calculated ones. Output correction factors within +0.7% and −1.4% were obtained down to field sizes as narrow as 5 mm. The resulting MD and Si-D field factors are in agreement within 0.2% in the case of CyberKnife measurements and 1.6% in the other cases. This latter higher spread of the data was demonstrated to be due to a lower reproducibility of small beam sizes defined by jaws or multi leaf collimators. The results of the present study demonstrate the reproducibility of the MD response and provide a validation of the MC modelling of this device. In principle, accurate reference dosimetry is thus feasible by using the microDiamond dosimeter for field sizes down to 5 mm.
- 1 February 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (4) , 1642-1643
Corrigendum: Monte Carlo simulated corrections for beam commissioning measurements with circular and MLC shaped fields on the CyberKnife M6 system: a study including diode, microchamber, point scintillator, and synthetic microdiamond detectors (2017 Phys. Med. Biol . 62 1076)
- 1 February 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (4) , 1642-1643
Corrigendum: Monte Carlo simulated corrections for beam commissioning measurements with circular and MLC shaped fields on the CyberKnife M6 system: a study including diode, microchamber, point scintillator, and synthetic microdiamond detectors (2017 Phys. Med. Biol . 62 1076)
- 7 August 2014
- Published by Springer Nature in The European Physical Journal B
- Vol. 87 (8) , 184
On stochastic spatial patterns and neuronal polarity
- 7 August 2014
- Published by Springer Nature in The European Physical Journal B
- Vol. 87 (8) , 184
On stochastic spatial patterns and neuronal polarity
- 23 January 2014
- Published by Springer Nature in The European Physical Journal Special Topics
- Vol. 223 (1) , 167-175
Sharp fronts in attracting-adatom monolayers
- 23 January 2014
- Published by Springer Nature in The European Physical Journal Special Topics
- Vol. 223 (1) , 167-175
Sharp fronts in attracting-adatom monolayers
- 18 July 2012
- Published by Springer Nature in LO SCALPELLO-OTODI Educational
- Vol. 26 (2) , 62-65
Navigazione preoperatoria con “planning” radiografico per protesi totale di ginocchio
- 18 July 2012
- Published by Springer Nature in LO SCALPELLO-OTODI Educational
- Vol. 26 (2) , 62-65
Navigazione preoperatoria con “planning” radiografico per protesi totale di ginocchio
- 13 July 2012
- Published by Springer Nature in Supportive Care in Cancer
- Vol. 21 (2) , 413-419
Cancer-related fatigue in Italian cancer patients: validation of the Italian version of the Brief Fatigue Inventory (BFI)
Cancer-related fatigue (CRF) is one of the most common symptoms experienced by cancer patients (CPs). The Brief Fatigue Inventory (BFI) is a reliable instrument to assess CRF in CPs. The aim of this study was to evaluate the psychometric properties of the Italian version of the BFI (BFI-I). The BFI-I was developed by using the forward–backward translation approach. The psychometric properties of the BFI-I were assessed in terms of acceptability, internal consistency, and validity. Outpatient CPs filled in BFI-I along with the Medical Outcome Study Quality of Life Short Form 36 (SF36). Demographic and health data were collected. The BFI-I had an overall Cronbach alpha for the nine items of 0.94. The inter-item mean correlation was 0.64, and coefficients ranged from 0.47 to 0.81 for the nine items. The results of the factor analysis suggested a 1-factor solution explaining 68 % of the variance, supporting the hypothesis of unidimensionality of the BFI-I. The BFI-I score was compared to SF36 subscales score to evaluate concurrent validity. An expected inverse correlation between the BFI-I and the vitality subscale of the SF36 was observed (r = −0.67, 95 % confidence interval −0.73 to −0.59). The correlation with the other subscales of the SF36 ranged between −0.56 and −0.13. Discriminant validity analysis showed the BFI-I mean score significantly increased with increasing Eastern Cooperative Oncology Group values (p < 0.001). BFI-I is a clinical instrument with satisfactory psychometric properties to assess CRF in Italian CPs.
- 13 July 2012
- Published by Springer Nature in Supportive Care in Cancer
- Vol. 21 (2) , 413-419
Cancer-related fatigue in Italian cancer patients: validation of the Italian version of the Brief Fatigue Inventory (BFI)
Cancer-related fatigue (CRF) is one of the most common symptoms experienced by cancer patients (CPs). The Brief Fatigue Inventory (BFI) is a reliable instrument to assess CRF in CPs. The aim of this study was to evaluate the psychometric properties of the Italian version of the BFI (BFI-I). The BFI-I was developed by using the forward–backward translation approach. The psychometric properties of the BFI-I were assessed in terms of acceptability, internal consistency, and validity. Outpatient CPs filled in BFI-I along with the Medical Outcome Study Quality of Life Short Form 36 (SF36). Demographic and health data were collected. The BFI-I had an overall Cronbach alpha for the nine items of 0.94. The inter-item mean correlation was 0.64, and coefficients ranged from 0.47 to 0.81 for the nine items. The results of the factor analysis suggested a 1-factor solution explaining 68 % of the variance, supporting the hypothesis of unidimensionality of the BFI-I. The BFI-I score was compared to SF36 subscales score to evaluate concurrent validity. An expected inverse correlation between the BFI-I and the vitality subscale of the SF36 was observed (r = −0.67, 95 % confidence interval −0.73 to −0.59). The correlation with the other subscales of the SF36 ranged between −0.56 and −0.13. Discriminant validity analysis showed the BFI-I mean score significantly increased with increasing Eastern Cooperative Oncology Group values (p < 0.001). BFI-I is a clinical instrument with satisfactory psychometric properties to assess CRF in Italian CPs.
- 13 May 2011
- Published by Springer Nature in Experimental Astronomy
- Vol. 34 (2) , 519-549
ORIGIN: metal creation and evolution from the cosmic dawn
- 13 May 2011
- Published by Springer Nature in Experimental Astronomy
- Vol. 34 (2) , 519-549
ORIGIN: metal creation and evolution from the cosmic dawn
- 25 February 2010
- Published by Springer Nature in Astrophysics and Space Science Proceedings
- p. 479
XMM–Newton Data Analysis with SAS Software Over GRID Technology
- 25 February 2010
- Published by Springer Nature in Astrophysics and Space Science Proceedings
- p. 479
XMM–Newton Data Analysis with SAS Software Over GRID Technology
- Open Access
- 1 September 2008
- Published by Springer Nature in The European Physical Journal C
- Vol. 57 (1-2) , 309-492
B, D and K decays
- 1 September 2008
- Published by Springer Nature in The European Physical Journal C
- Vol. 57 (1-2) , 309-492
Open AccessB, D and K decays