National Power Training Institute

Type
FacilityLocations
Faridabad, IndiaLatest Publications
- 22 April 2026
- Published by Dr. Yashwant Research Labs Pvt. Ltd. in International Journal of Drug Delivery Technology
- Vol. 16 (16s)
Enhancing Bearing Fault Diagnosis in Three-Phase Induction Motors Using Motor Current Signature Analysis
The detection and analysis of faults in the ball bearings of induction motors are crucial for ensuring the reliable operation of motors. This paper deals with the use of Motor Current Signature Analysis (MCSA) together with Harmonics Fast Fourier Transform (FFT) to identify bearing defects. During operation, the bearings of induction motors are subjected to dynamic forces, which account for their deterioration is one of the leading causes of motor breakdowns in industrial systems. This study used a three-phase, 440V, four-pole, 1500 RPM induction motor for experimental testing.; three different bearing fault conditions of dry bearing, insufficient lubrication, and ball-damaged bearing were introduced in the setup. The performance analysis of the motor is carried out under no-load and rated-load conditions, and comparisons are drawn between the healthy and faulty states. From the results, it can be observed that due to the development of bearing faults, certain important parameters like torque, mechanical power, electrical power, power factor, three-phase voltage and current are increased; whereas the motor speed and efficiency decreased. Further, harmonic analysis indicates an increased harmonic content, with significant harmonics up to the 21st order. Hence, from the obtained results, it is concluded that MCSA and harmonic analysis are powerful tools that can be employed for early diagnosis and detection of induction motor bearing failures.
- 22 April 2026
- Published by Dr. Yashwant Research Labs Pvt. Ltd. in International Journal of Drug Delivery Technology
- Vol. 16 (16s)
Enhancing Bearing Fault Diagnosis in Three-Phase Induction Motors Using Motor Current Signature Analysis
The detection and analysis of faults in the ball bearings of induction motors are crucial for ensuring the reliable operation of motors. This paper deals with the use of Motor Current Signature Analysis (MCSA) together with Harmonics Fast Fourier Transform (FFT) to identify bearing defects. During operation, the bearings of induction motors are subjected to dynamic forces, which account for their deterioration is one of the leading causes of motor breakdowns in industrial systems. This study used a three-phase, 440V, four-pole, 1500 RPM induction motor for experimental testing.; three different bearing fault conditions of dry bearing, insufficient lubrication, and ball-damaged bearing were introduced in the setup. The performance analysis of the motor is carried out under no-load and rated-load conditions, and comparisons are drawn between the healthy and faulty states. From the results, it can be observed that due to the development of bearing faults, certain important parameters like torque, mechanical power, electrical power, power factor, three-phase voltage and current are increased; whereas the motor speed and efficiency decreased. Further, harmonic analysis indicates an increased harmonic content, with significant harmonics up to the 21st order. Hence, from the obtained results, it is concluded that MCSA and harmonic analysis are powerful tools that can be employed for early diagnosis and detection of induction motor bearing failures.
- Open Access
- 1 January 2026
- Published by IJ Research Organization in JOURNAL OF EMERGING TRENDS AND NOVEL RESEARCH
- Vol. 4 (7) , a745-a766
Realigning Employer Branding and Human Capital in the Age of AI: A Dual Framework for Internal Marketing and Employee Retention
Realigning Employer Branding and Human Capital in the Age of AI: A Dual Framework for Internal Marketing and Employee Retention, UGC CARE Journal, UGC CARE Approved Journals, UGC CARE Journal List, UGC CARE Journal Impact Factor, UGC CARE Journal Publication Guidelines, UGC CARE Journal Call for Papers, UGC CARE Journal Review Process, UGC CARE Journal Ranking, UGC CARE Journal Author Guidelines, JOURNAL OF EMERGING TRENDS AND NOVEL RESEARCH, UGC CARE Journal Subscription
- 1 January 2026
- Published by IJ Research Organization in JOURNAL OF EMERGING TRENDS AND NOVEL RESEARCH
- Vol. 4 (7) , a745-a766
Open AccessRealigning Employer Branding and Human Capital in the Age of AI: A Dual Framework for Internal Marketing and Employee Retention
Realigning Employer Branding and Human Capital in the Age of AI: A Dual Framework for Internal Marketing and Employee Retention, UGC CARE Journal, UGC CARE Approved Journals, UGC CARE Journal List, UGC CARE Journal Impact Factor, UGC CARE Journal Publication Guidelines, UGC CARE Journal Call for Papers, UGC CARE Journal Review Process, UGC CARE Journal Ranking, UGC CARE Journal Author Guidelines, JOURNAL OF EMERGING TRENDS AND NOVEL RESEARCH, UGC CARE Journal Subscription
- 2 May 2025
- Published by Elsevier in ISA Transactions
- Vol. 162, 162-178
Impact analysis of capacitive energy storage integration on load frequency control performance of microgrids employing a new dual-stage controller
- 2 May 2025
- Published by Elsevier in ISA Transactions
- Vol. 162, 162-178
Impact analysis of capacitive energy storage integration on load frequency control performance of microgrids employing a new dual-stage controller
- Open Access
- 1 January 2025
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 15 (vol15i3) , 578-588
A Robust Dual Mode Tilt Derivative-Integral Derivative Controller for Frequency Control Considering Renewable Energy Sources and Electrical Vehicle
A Robust Dual Mode Tilt Derivative-Integral Derivative Controller for Frequency Control Considering Renewable Energy Sources and Electrical Vehicle
- 1 January 2025
- Published by International Journal of Renewable Energy Research in International Journal of Renewable Energy Research
- Vol. 15 (vol15i3) , 578-588
Open AccessA Robust Dual Mode Tilt Derivative-Integral Derivative Controller for Frequency Control Considering Renewable Energy Sources and Electrical Vehicle
A Robust Dual Mode Tilt Derivative-Integral Derivative Controller for Frequency Control Considering Renewable Energy Sources and Electrical Vehicle
- 13 September 2024
- Published by Taylor & Francis in International Journal of Modelling and Simulation
- Vol. 46 (4) , 1-18
Load frequency control performance enhancement of an electric vehicle integrated time-delay multi-microgrid system
- 13 September 2024
- Published by Taylor & Francis in International Journal of Modelling and Simulation
- Vol. 46 (4) , 1-18
Load frequency control performance enhancement of an electric vehicle integrated time-delay multi-microgrid system
- Open Access
- 1 February 2024
- Published by Association for Computing Machinery (ACM)
- p. 24-30
Multi-Objective Combined Economic Emission Dispatch using Modified Firefly Algorithm: A Case Study of India
Economic load dispatch is seen as an important strategy by system planners to improve the energy efficiency. This becomes particularly relevant when renewable energy based generation is integrated into the system. The optimal dispatch planning necessitates implementation of an efficient optimization technique. This paper proposes a novel modified-firefly algorithm (MFA) to address the Combined Economic Emission Dispatch (CEED) problem, in order to aid the integration of renewable energy resources (RES) into the grid optimally. The proposed MFA is based on the hybridization of butterfly algorithm with conventional firefly algorithm. The MFA is tested on five different test systems considering each source individually and then the combination of all the sources. As a case study, the data for solar irradiance and wind speed has been considered for east coast of India. The results are analyzed to show the effect of RES integration on emission dispatch and cost reduction of the system. Also, the effect of non-linear constraints is shown on IEEE 30-bus system. The efficacy of MFA is compared with conventional firefly algorithm (FA) in terms of search capability for global optima. The results demonstrate that MFA offers improved solutions as compared to conventional FA for all the five test cases. The results indicate a total cost saving of approximately 8% as compared to the conventional FA.
- 1 February 2024
- Published by Association for Computing Machinery (ACM)
- p. 24-30
Open AccessMulti-Objective Combined Economic Emission Dispatch using Modified Firefly Algorithm: A Case Study of India
Economic load dispatch is seen as an important strategy by system planners to improve the energy efficiency. This becomes particularly relevant when renewable energy based generation is integrated into the system. The optimal dispatch planning necessitates implementation of an efficient optimization technique. This paper proposes a novel modified-firefly algorithm (MFA) to address the Combined Economic Emission Dispatch (CEED) problem, in order to aid the integration of renewable energy resources (RES) into the grid optimally. The proposed MFA is based on the hybridization of butterfly algorithm with conventional firefly algorithm. The MFA is tested on five different test systems considering each source individually and then the combination of all the sources. As a case study, the data for solar irradiance and wind speed has been considered for east coast of India. The results are analyzed to show the effect of RES integration on emission dispatch and cost reduction of the system. Also, the effect of non-linear constraints is shown on IEEE 30-bus system. The efficacy of MFA is compared with conventional firefly algorithm (FA) in terms of search capability for global optima. The results demonstrate that MFA offers improved solutions as compared to conventional FA for all the five test cases. The results indicate a total cost saving of approximately 8% as compared to the conventional FA.
- 27 January 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 106 (4) , 1-19
Frequency regulation in a microgrid integrating redox flow battery by utilizing an optimal predictive control approach
- 27 January 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 106 (4) , 1-19
Frequency regulation in a microgrid integrating redox flow battery by utilizing an optimal predictive control approach
- Open Access
- 6 July 2023
- Published by Springer Nature in Research Square
Frequency regulation in a microgrid integrating redox flow battery by utilizing an optimal predictive control approach
When considering the frequency stability issues brought on by load shifts in a microgrid (µG) due to a significant integration of fluctuating renewable energy source (RES)-based generators and an inherent low inertia, energy storage units (ESUs) are unavoidable. The ESUs can immediately charge or discharge to make up for any shifts in load in the µG since they react more quickly. This research investigates how a redox flow battery unit (RFBU) impacts the dynamic responses of a standalone µG (SµG) in this respect. As the secondary controller, an optimal intelligent model predictive control (iMPC) approach is presented. The cyclical parthenogenesis algorithm (CPA) is implemented to improve the tuning parameter (τw) in the iMPC cost function to demonstrate an optimal performance of the recommended control approach. The effectiveness of the iMPC approach is contrasted with that of other well-known control approaches. The simulation findings clearly demonstrate the impact of RFBU integration in the SµG and the capability of the recommended iMPC approach in terms of improved dynamic responses and their transient characteristics. As a consequence , the peak value of the SµG dynamic response improves by 70.53%, and the settling time improves by 82.26%. The suggested control approach’s sensitivity to the SµG parametric uncertainties is also justified. The closed-loop stability of the suggested approach is also established. The effectiveness of the proposed iMPC approach and the impact of the RFBU integration are then confirmed by statistical analysis.
- 6 July 2023
- Published by Springer Nature in Research Square
Open AccessFrequency regulation in a microgrid integrating redox flow battery by utilizing an optimal predictive control approach
When considering the frequency stability issues brought on by load shifts in a microgrid (µG) due to a significant integration of fluctuating renewable energy source (RES)-based generators and an inherent low inertia, energy storage units (ESUs) are unavoidable. The ESUs can immediately charge or discharge to make up for any shifts in load in the µG since they react more quickly. This research investigates how a redox flow battery unit (RFBU) impacts the dynamic responses of a standalone µG (SµG) in this respect. As the secondary controller, an optimal intelligent model predictive control (iMPC) approach is presented. The cyclical parthenogenesis algorithm (CPA) is implemented to improve the tuning parameter (τw) in the iMPC cost function to demonstrate an optimal performance of the recommended control approach. The effectiveness of the iMPC approach is contrasted with that of other well-known control approaches. The simulation findings clearly demonstrate the impact of RFBU integration in the SµG and the capability of the recommended iMPC approach in terms of improved dynamic responses and their transient characteristics. As a consequence , the peak value of the SµG dynamic response improves by 70.53%, and the settling time improves by 82.26%. The suggested control approach’s sensitivity to the SµG parametric uncertainties is also justified. The closed-loop stability of the suggested approach is also established. The effectiveness of the proposed iMPC approach and the impact of the RFBU integration are then confirmed by statistical analysis.
- Open Access
A Smart Microgrid System with Artificial Intelligence for Power-Sharing and Power Quality Improvement
The widespread popularity of renewable and sustainable sources of energy such as solar and wind calls for the integration of renewable energy sources into electrical power grids for sustainable development. Microgrids minimize power quality issues in the main grid by linking with an active filter and furnishing reactive power compensation, harmonic mitigation, and load balancing at the point of common coupling. The reliability issues faced by standalone DC microgrids can be managed by interlinking microgrids with a power grid. An artificial intelligence-based Icos control algorithm for power sharing and power quality improvement in smart microgrid systems is proposed here to render grid-integrated power systems more intelligent. The proposed controller considers various uncertainties caused by load variations, state of charge of the battery of microgrids, and power tariff based on the availability of power in microgrids. This paper presents a detailed analysis of the integration of wind and solar microgrids with the grid for dynamic power flow management in order to improve the power quality and to reduce the burden, thereby strengthening the central grid. A smart grid system with multiple smart microgrids coupled with a renewable energy source with tariff control and judicious power flow management was simulated for power-sharing and power quality improvement. A hardware prototype of the artificial intelligence-based Icos control algorithm with nonlinear load was also implemented successfully. Furthermore, the economic viability was investigated to ensure the feasibility of the smart microgrid system with the proposed controller design for power flow management and power quality improvement.Open AccessA Smart Microgrid System with Artificial Intelligence for Power-Sharing and Power Quality Improvement
The widespread popularity of renewable and sustainable sources of energy such as solar and wind calls for the integration of renewable energy sources into electrical power grids for sustainable development. Microgrids minimize power quality issues in the main grid by linking with an active filter and furnishing reactive power compensation, harmonic mitigation, and load balancing at the point of common coupling. The reliability issues faced by standalone DC microgrids can be managed by interlinking microgrids with a power grid. An artificial intelligence-based Icos control algorithm for power sharing and power quality improvement in smart microgrid systems is proposed here to render grid-integrated power systems more intelligent. The proposed controller considers various uncertainties caused by load variations, state of charge of the battery of microgrids, and power tariff based on the availability of power in microgrids. This paper presents a detailed analysis of the integration of wind and solar microgrids with the grid for dynamic power flow management in order to improve the power quality and to reduce the burden, thereby strengthening the central grid. A smart grid system with multiple smart microgrids coupled with a renewable energy source with tariff control and judicious power flow management was simulated for power-sharing and power quality improvement. A hardware prototype of the artificial intelligence-based Icos control algorithm with nonlinear load was also implemented successfully. Furthermore, the economic viability was investigated to ensure the feasibility of the smart microgrid system with the proposed controller design for power flow management and power quality improvement. - Open Access
- 30 May 2022
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 3,p. 63-70
A novel load shedding methodology to mitigate voltage instability in power system
Aim. A novel technique for detecting imminent voltage instability is proposed in this paper, accompanied by a novel load shedding approach to protect the system from voltage instability. Methodology. The proposed methodology utilizes the computation of nodal reactive power loss to voltage sensitivities with load increments in the system. Originality. The nodal reactive power loss to voltage sensitivity is a novel computation and is explored to detect the likelihood of voltage instability in this work. Results. If the system is experiencing an unprecedented load growth and if all the measures reach their limits, then load shedding is the last resort to safeguard the system against instability. The sudden change in nodal reactive power loss to voltage sensitivities is utilized to devise the quantity of load to be cut in the system. Practical value. The time-based simulations performed in New England 39 bus test system (NE-39 bus), the simulated results show that nodal reactive power loss to voltage sensitivities can be used as a trusted indicator for early diagnosing of menacing voltage instability and the timely implementation of load shedding developed from nodal reactive power loss to voltage sensitivities on the system ensures voltage stability.
- 30 May 2022
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 3,p. 63-70
Open AccessA novel load shedding methodology to mitigate voltage instability in power system
Aim. A novel technique for detecting imminent voltage instability is proposed in this paper, accompanied by a novel load shedding approach to protect the system from voltage instability. Methodology. The proposed methodology utilizes the computation of nodal reactive power loss to voltage sensitivities with load increments in the system. Originality. The nodal reactive power loss to voltage sensitivity is a novel computation and is explored to detect the likelihood of voltage instability in this work. Results. If the system is experiencing an unprecedented load growth and if all the measures reach their limits, then load shedding is the last resort to safeguard the system against instability. The sudden change in nodal reactive power loss to voltage sensitivities is utilized to devise the quantity of load to be cut in the system. Practical value. The time-based simulations performed in New England 39 bus test system (NE-39 bus), the simulated results show that nodal reactive power loss to voltage sensitivities can be used as a trusted indicator for early diagnosing of menacing voltage instability and the timely implementation of load shedding developed from nodal reactive power loss to voltage sensitivities on the system ensures voltage stability.