Lonza (Germany)
Latest Publications
- 13 August 2020
- Published by American Association for Cancer Research (AACR) in Cancer Research
- Vol. 80 (16 Supplem) , 334
Abstract 334: Creation and analysis of advanced in vitro cancer models in the real architecture for 3D tissue (RAFT™) culture system
Conventional in vitro assays are based on cells grown on two-dimensional (2D) substrates, which are not representative of the true in vivo cell environment. In tissue environments, cells interact with neighboring cells and the extracellular matrix (ECM). Three-dimensional (3D) cell culture methods allow cells to grow in structures more resembling the in vivo environment. The RAFT™ 3D Culture System uses a collagen matrix at physiologically relevant concentrations. In the presented applications, cells from the colon cancer line HCT 116 and neutralized collagen are mixed and subsequently incubated at 37°C to allow the formation of a cell-seeded hydrogel. Specialized RAFT™ Absorbers are placed on top of the hydrogels. Those absorbers gently remove abundant medium, thus compacting the cell/collagen hydrogel prior futher culture. Additional cell types like fibroblasts, endothelial or epithelial cells may be added to allow the creation of more complex models. While 3D cultures more closely mimic the in vivo cell environment, it is often difficult to apply transient transfection methods to these dense, tissue-like structures. Here we give a guideline how to use the electroporation-based Nucleofector™ Technology for creating transiently transfected cells for further culture in the RAFT™ System. HCT 116 was harvested and transfected with pmaxGFP™ Vector in suspension using the 4D Nucleofector™ System X-Unit. Subsequently, cells were embedded in RAFT™ Cultures. Overall transfection efficiencies and cell viabilities were comparable between RAFT™ 3D Cultures and standard 2D cultures. Transfection efficiencies of more than 90% were observed in both formats. GFP expression was still detectable 4 days after transfection. Innovative gene-editing tools like CRISPR-Cas nuclease-based systems could be used to obtain more long-term transgene expression. Another challenge is the analysis of cells in dense, tissue-like structures compared to 2D monolayer culture. HCT 116 cells formed compact aggregate-like structures in RAFT™ 3D Cultures that resembled small tumors in vivo. Therefore, we developed a protocol for immunocytochemistry that allows effective antibody staining of HCT 116 containing RAFT™ Cultures. In addition, we will explain how to measure cell viability in RAFT™ Cultures with the ViaLight™ Plus Cell Proliferation and Cytotoxicity BioAssay. The ViaLight™ Assay is based on the bioluminescent detection of cellular ATP as a measure of cell viability. Only minor modifications of the standard 2D cell culture protocol are required for using the assay for RAFT™ Cultures. By elongating the lysis step of the Vialight™ Assay from 10 minutes to 30 minutes, a similar performance of the assay was observed for HCT 116 containing 2D and RAFT™ Cultures. In summary, we show how easily genetically modified in vitro 3D cancer models can be generated in the RAFT™ 3D Cell Culture System and how such models can be analyzed using standard methods like immunocytochemistry and the ViaLight™ Viability Assay. Citation Format: Sabine Schaepermeier, Theresa D'Souza, Aurita Menezes, Claudia Schwartz, Jenny Schroeder. Creation and analysis of advanced in vitro cancer models in the real architecture for 3D tissue (RAFT™) culture system [abstract]. In: Proceedings of the Annual Meeting of the American Association for Cancer Research 2020; 2020 Apr 27-28 and Jun 22-24. Philadelphia (PA): AACR; Cancer Res 2020;80(16 Suppl):Abstract nr 334.
- 13 August 2020
- Published by American Association for Cancer Research (AACR) in Cancer Research
- Vol. 80 (16 Supplem) , 334
Abstract 334: Creation and analysis of advanced in vitro cancer models in the real architecture for 3D tissue (RAFT™) culture system
Conventional in vitro assays are based on cells grown on two-dimensional (2D) substrates, which are not representative of the true in vivo cell environment. In tissue environments, cells interact with neighboring cells and the extracellular matrix (ECM). Three-dimensional (3D) cell culture methods allow cells to grow in structures more resembling the in vivo environment. The RAFT™ 3D Culture System uses a collagen matrix at physiologically relevant concentrations. In the presented applications, cells from the colon cancer line HCT 116 and neutralized collagen are mixed and subsequently incubated at 37°C to allow the formation of a cell-seeded hydrogel. Specialized RAFT™ Absorbers are placed on top of the hydrogels. Those absorbers gently remove abundant medium, thus compacting the cell/collagen hydrogel prior futher culture. Additional cell types like fibroblasts, endothelial or epithelial cells may be added to allow the creation of more complex models. While 3D cultures more closely mimic the in vivo cell environment, it is often difficult to apply transient transfection methods to these dense, tissue-like structures. Here we give a guideline how to use the electroporation-based Nucleofector™ Technology for creating transiently transfected cells for further culture in the RAFT™ System. HCT 116 was harvested and transfected with pmaxGFP™ Vector in suspension using the 4D Nucleofector™ System X-Unit. Subsequently, cells were embedded in RAFT™ Cultures. Overall transfection efficiencies and cell viabilities were comparable between RAFT™ 3D Cultures and standard 2D cultures. Transfection efficiencies of more than 90% were observed in both formats. GFP expression was still detectable 4 days after transfection. Innovative gene-editing tools like CRISPR-Cas nuclease-based systems could be used to obtain more long-term transgene expression. Another challenge is the analysis of cells in dense, tissue-like structures compared to 2D monolayer culture. HCT 116 cells formed compact aggregate-like structures in RAFT™ 3D Cultures that resembled small tumors in vivo. Therefore, we developed a protocol for immunocytochemistry that allows effective antibody staining of HCT 116 containing RAFT™ Cultures. In addition, we will explain how to measure cell viability in RAFT™ Cultures with the ViaLight™ Plus Cell Proliferation and Cytotoxicity BioAssay. The ViaLight™ Assay is based on the bioluminescent detection of cellular ATP as a measure of cell viability. Only minor modifications of the standard 2D cell culture protocol are required for using the assay for RAFT™ Cultures. By elongating the lysis step of the Vialight™ Assay from 10 minutes to 30 minutes, a similar performance of the assay was observed for HCT 116 containing 2D and RAFT™ Cultures. In summary, we show how easily genetically modified in vitro 3D cancer models can be generated in the RAFT™ 3D Cell Culture System and how such models can be analyzed using standard methods like immunocytochemistry and the ViaLight™ Viability Assay. Citation Format: Sabine Schaepermeier, Theresa D'Souza, Aurita Menezes, Claudia Schwartz, Jenny Schroeder. Creation and analysis of advanced in vitro cancer models in the real architecture for 3D tissue (RAFT™) culture system [abstract]. In: Proceedings of the Annual Meeting of the American Association for Cancer Research 2020; 2020 Apr 27-28 and Jun 22-24. Philadelphia (PA): AACR; Cancer Res 2020;80(16 Suppl):Abstract nr 334.
- 12 September 2018
- Published by Elsevier in Toxicology Letters
- Vol. 295, S116
Primary human hepatocyte spheroid generation and performance in different culture systems
- 12 September 2018
- Published by Elsevier in Toxicology Letters
- Vol. 295, S116
Primary human hepatocyte spheroid generation and performance in different culture systems
- 1 September 2018
- Published by SAGE Publications in Applied In Vitro Toxicology
- Vol. 4 (3) , 232-237
A Novel In Vitro Liver Cell Culture Flow System Allowing Long-Term Metabolism and Hepatotoxicity Studies
Introduction: Hepatotoxicity is a concern when developing new pharmaceutical compounds. Animal models do not accurately predict toxicity in humans due to species differences, for example, in compound metabolism. In this study, we present an alternative in vitro model based on the culture of primary human hepatocytes (PHH) in the Quasi Vivo® QV900 Flow System.Materials and Methods: PHH were kept in sandwich culture in static and in perfused conditions. During 3 weeks of culture, viability and albumin content were quantified. Basal and induced cytochrome P450 (CYP) enzyme activity were assessed by luminescence assay and analysis of metabolite formation.Results: Good cell viability and sustained albumin production were observed in perfused culture. In comparison to nonperfused cultures, the basal activity of the drug metabolism enzymes CYP3A4, CYP1A2, and CYP2B6 was increased. Induced CYP3A4 activity was comparable between perfused and nonperfused cultures. Furthermore, the QV900 System allowed fewer medium changes as typically required in static cultures. This enables buildup of potential toxic metabolites that would otherwise not be detected when media are refreshed daily.Discussion: PHH can be cultured in the QV900 Flow System for 3 weeks with only two medium changes per week. Improved basal CYP activity was observed in comparison to static culture.Conclusion: We present a liver cell culture flow system that improves longer-term stability of drug metabolism enzymes in PHH and is therefore a more human-relevant in vitro model for repeat dosing of hepatotoxicants.
- 1 September 2018
- Published by SAGE Publications in Applied In Vitro Toxicology
- Vol. 4 (3) , 232-237
A Novel In Vitro Liver Cell Culture Flow System Allowing Long-Term Metabolism and Hepatotoxicity Studies
Introduction: Hepatotoxicity is a concern when developing new pharmaceutical compounds. Animal models do not accurately predict toxicity in humans due to species differences, for example, in compound metabolism. In this study, we present an alternative in vitro model based on the culture of primary human hepatocytes (PHH) in the Quasi Vivo® QV900 Flow System.Materials and Methods: PHH were kept in sandwich culture in static and in perfused conditions. During 3 weeks of culture, viability and albumin content were quantified. Basal and induced cytochrome P450 (CYP) enzyme activity were assessed by luminescence assay and analysis of metabolite formation.Results: Good cell viability and sustained albumin production were observed in perfused culture. In comparison to nonperfused cultures, the basal activity of the drug metabolism enzymes CYP3A4, CYP1A2, and CYP2B6 was increased. Induced CYP3A4 activity was comparable between perfused and nonperfused cultures. Furthermore, the QV900 System allowed fewer medium changes as typically required in static cultures. This enables buildup of potential toxic metabolites that would otherwise not be detected when media are refreshed daily.Discussion: PHH can be cultured in the QV900 Flow System for 3 weeks with only two medium changes per week. Improved basal CYP activity was observed in comparison to static culture.Conclusion: We present a liver cell culture flow system that improves longer-term stability of drug metabolism enzymes in PHH and is therefore a more human-relevant in vitro model for repeat dosing of hepatotoxicants.
- Open Access
- 1 July 2017
- Published by American Association for Cancer Research (AACR) in Cancer Research
- Vol. 77 (13_Supplem) , 822
Abstract 822: Simple and easy monitoring of tube formation and migration assays with the CytoSMARTTM Live Cell Imaging System
Movement of cells plays a critical role in the development of cancer. Analyzing the motility of cells in appropriate cell culture models is therefore an important tool for cancer researchers. Live cell imaging is particularly well suited to capture dynamic processes in cell culture. The CytoSMART™ Device is an easy-to-use, small and affordable live cell monitoring system suitable for the label-free analysis of cell motility within a standard cell culture incubator. Label-free approaches offer the benefit of cell analysis without potential cytotoxic or other side-effects of the used markers or dyes on the cells. This presentation shows the suitability of the CytoSMART™ Device for the analysis of different cancer-relevant assays. The formation of new blood vessels is required to ensure sufficient nutrient and oxygen supply and to allow solid tumors to grow beyond a certain size. This process can be mimicked in cell culture models in so-called tube formation assays. In this study, Human Umbilical Vein Endothelial Cells (HUVEC) were seeded on Engelbreth-Holm Swarm Sarcoma derived Basement Membrane Extract (BME). The resulting formation of endothelial tubes was monitored with the CytoSMART™ Device. Subsequently, the average length of the formed tubes as well as the number of closed tube circles was quantitatively determined. In addition, the impact of Suramin on tube formation was evaluated as an example for a tube formation inhibiting compound. The migration of cancer cells is also required for the growth and in particular the metastasis of tumors. In a first example, the closure of a so-called wound or scratch in a confluent monolayer of cancer cells was monitored with the CytoSMART™ Device. Determining the migration speed of the cells by measuring the speed of wound closure is a simple assay to determine the migration potential of cancer cells. Modifying the cancer cells, e.g. by knocking down specific genes with siRNA, can help to identify genes that play a role in cell migration. Compounds that are expected to reduce cell motility and therefore reduce the metastasis potential of cancer cells can be easily tested. In a second example, the invasion of cancer cells into a three-dimensional (3D) matrix was analyzed. Tumor cells were embedded in a cancer-relevant matrix and their invasion into the 3D matrix was documented with the CytoSMART™ Device. While this type of model is slightly more difficult in set-up and analysis compared to simple scratch assays, it may reflect better the in vivo situation where solid tumors develop within three-dimensional tissues. The images captured with the CytoSMART™ System were quantitatively analyzed using appropriate software. Overall, the CytoSMART™ System is an easy-to-use, small and affordable live cell imaging system suitable for the label-free analysis of different cancer-relevant assays. Citation Format: Stefanie Buesch, Sabine Schaepermeier, Theresa D'Souza, Bodo Ortmann, Claudia Schwartz, Jenny Schroeder. Simple and easy monitoring of tube formation and migration assays with the CytoSMARTTM Live Cell Imaging System [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2017; 2017 Apr 1-5; Washington, DC. Philadelphia (PA): AACR; Cancer Res 2017;77(13 Suppl):Abstract nr 822. doi:10.1158/1538-7445.AM2017-822
- 1 July 2017
- Published by American Association for Cancer Research (AACR) in Cancer Research
- Vol. 77 (13_Supplem) , 822
Open AccessAbstract 822: Simple and easy monitoring of tube formation and migration assays with the CytoSMARTTM Live Cell Imaging System
Movement of cells plays a critical role in the development of cancer. Analyzing the motility of cells in appropriate cell culture models is therefore an important tool for cancer researchers. Live cell imaging is particularly well suited to capture dynamic processes in cell culture. The CytoSMART™ Device is an easy-to-use, small and affordable live cell monitoring system suitable for the label-free analysis of cell motility within a standard cell culture incubator. Label-free approaches offer the benefit of cell analysis without potential cytotoxic or other side-effects of the used markers or dyes on the cells. This presentation shows the suitability of the CytoSMART™ Device for the analysis of different cancer-relevant assays. The formation of new blood vessels is required to ensure sufficient nutrient and oxygen supply and to allow solid tumors to grow beyond a certain size. This process can be mimicked in cell culture models in so-called tube formation assays. In this study, Human Umbilical Vein Endothelial Cells (HUVEC) were seeded on Engelbreth-Holm Swarm Sarcoma derived Basement Membrane Extract (BME). The resulting formation of endothelial tubes was monitored with the CytoSMART™ Device. Subsequently, the average length of the formed tubes as well as the number of closed tube circles was quantitatively determined. In addition, the impact of Suramin on tube formation was evaluated as an example for a tube formation inhibiting compound. The migration of cancer cells is also required for the growth and in particular the metastasis of tumors. In a first example, the closure of a so-called wound or scratch in a confluent monolayer of cancer cells was monitored with the CytoSMART™ Device. Determining the migration speed of the cells by measuring the speed of wound closure is a simple assay to determine the migration potential of cancer cells. Modifying the cancer cells, e.g. by knocking down specific genes with siRNA, can help to identify genes that play a role in cell migration. Compounds that are expected to reduce cell motility and therefore reduce the metastasis potential of cancer cells can be easily tested. In a second example, the invasion of cancer cells into a three-dimensional (3D) matrix was analyzed. Tumor cells were embedded in a cancer-relevant matrix and their invasion into the 3D matrix was documented with the CytoSMART™ Device. While this type of model is slightly more difficult in set-up and analysis compared to simple scratch assays, it may reflect better the in vivo situation where solid tumors develop within three-dimensional tissues. The images captured with the CytoSMART™ System were quantitatively analyzed using appropriate software. Overall, the CytoSMART™ System is an easy-to-use, small and affordable live cell imaging system suitable for the label-free analysis of different cancer-relevant assays. Citation Format: Stefanie Buesch, Sabine Schaepermeier, Theresa D'Souza, Bodo Ortmann, Claudia Schwartz, Jenny Schroeder. Simple and easy monitoring of tube formation and migration assays with the CytoSMARTTM Live Cell Imaging System [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2017; 2017 Apr 1-5; Washington, DC. Philadelphia (PA): AACR; Cancer Res 2017;77(13 Suppl):Abstract nr 822. doi:10.1158/1538-7445.AM2017-822
- 15 July 2016
- Published by American Association for Cancer Research (AACR) in Cancer Research
- Vol. 76 (14_Supplem) , 607
Abstract 607: Analyzing cell viability in 3-D tissue models with the ViaLight™ plus cell proliferation and cytotoxicity bioassay
Conventional in vitro assays are based on cells grown on two-dimensional (2D) substrates, which are not representative of the true in vivo cell environment. In tissue environments, cells interact with neighboring cells and the extracellular matrix (ECM). Three-dimensional (3D) cell culture methods allow cells to grow in structures more resembling the in vivo environment. Cells can develop cell-cell and cell-ECM interactions in 3D. The RAFT™ 3D Culture System uses a collagen matrix at physiologically relevant concentrations. Cells and neutralized collagen are mixed and subsequently incubated at 37°C to allow the formation of a cell-seeded hydrogel. Specialized RAFT™ Absorbers are placed on top of the hydrogels. The RAFT™ Absorbers gently remove abundant medium, thus compacting the cell/collagen hydrogel. Additional epithelial or endothelial cells may be added as overlays on top to study co-cultures or more complex cultures. Another commonly used 3D cell culture model is spheroids. Spheroids are compact aggregates of cells that are generated without the addition of exogenous ECM – e.g. in so-called ultra-low attachment (ULA) plates or by the hanging-drop method. While 3D cultures more accurately mimic the in vivo cell environment, it might be difficult to analyze cells in 3D due to the dense, tissue-like structure of these cultures compared to 2D cell monolayers. This presentation explains how to measure cell viability in both RAFT™ 3D cell cultures and in spheroid cultures with the ViaLight™ Plus Cell Proliferation and Cytotoxicity BioAssay. The ViaLight™ Assay is based on the bioluminescent detection of cellular ATP as a measure of cell viability. Only minor modifications of the standard two-step protocol that is used for 2D cell cultures are required for using the assay for 96-well and 24-well RAFT™ 3D cell cultures as well as for spheroid cultures in 96-well ULA plates. Two different cell types were used in this study: Normal Human Dermal Fibroblasts (NHDFneo) and the colon cancer cell line HCT-116. Both cell types efficiently form spheroids in ULA plates. Also in RAFT™ 3D cultures HCT-116 cells build compact aggregate-like structures, whereas NHDFneo grow in as individual cells interspersed in the collagen scaffold. By elongating the first step of the Vialight™ Assay, the lysis step, from 10 minutes to 30 minutes, a linear performance of the assay for cell numbers of up to 96,000 cells in the 96-well format and 480,000 cells in the 24-well format could be obtained for RAFT™ cultures. For spheroid cultures an extension of the lysis time to 60 minutes was required to obtain efficient lysis of spheroids with a diameter of up to 400μm, as confirmed by CalceinAM and propidium iodide staining. In summary this presentation shows that analyzing cells in 3D cultures can easily and routinely be done by slightly adjusting standard 2D cell culture assays like the ViaLight™ Assay. Citation Format: Stefanie Buesch, John Langer, Sabine Schaepermeier, Lubna Hussain, Jeffrey Bergeron, Volker Vogel, Jenny Schroeder. Analyzing cell viability in 3-D tissue models with the ViaLight™ plus cell proliferation and cytotoxicity bioassay. [abstract]. In: Proceedings of the 107th Annual Meeting of the American Association for Cancer Research; 2016 Apr 16-20; New Orleans, LA. Philadelphia (PA): AACR; Cancer Res 2016;76(14 Suppl):Abstract nr 607.
- 15 July 2016
- Published by American Association for Cancer Research (AACR) in Cancer Research
- Vol. 76 (14_Supplem) , 607
Abstract 607: Analyzing cell viability in 3-D tissue models with the ViaLight™ plus cell proliferation and cytotoxicity bioassay
Conventional in vitro assays are based on cells grown on two-dimensional (2D) substrates, which are not representative of the true in vivo cell environment. In tissue environments, cells interact with neighboring cells and the extracellular matrix (ECM). Three-dimensional (3D) cell culture methods allow cells to grow in structures more resembling the in vivo environment. Cells can develop cell-cell and cell-ECM interactions in 3D. The RAFT™ 3D Culture System uses a collagen matrix at physiologically relevant concentrations. Cells and neutralized collagen are mixed and subsequently incubated at 37°C to allow the formation of a cell-seeded hydrogel. Specialized RAFT™ Absorbers are placed on top of the hydrogels. The RAFT™ Absorbers gently remove abundant medium, thus compacting the cell/collagen hydrogel. Additional epithelial or endothelial cells may be added as overlays on top to study co-cultures or more complex cultures. Another commonly used 3D cell culture model is spheroids. Spheroids are compact aggregates of cells that are generated without the addition of exogenous ECM – e.g. in so-called ultra-low attachment (ULA) plates or by the hanging-drop method. While 3D cultures more accurately mimic the in vivo cell environment, it might be difficult to analyze cells in 3D due to the dense, tissue-like structure of these cultures compared to 2D cell monolayers. This presentation explains how to measure cell viability in both RAFT™ 3D cell cultures and in spheroid cultures with the ViaLight™ Plus Cell Proliferation and Cytotoxicity BioAssay. The ViaLight™ Assay is based on the bioluminescent detection of cellular ATP as a measure of cell viability. Only minor modifications of the standard two-step protocol that is used for 2D cell cultures are required for using the assay for 96-well and 24-well RAFT™ 3D cell cultures as well as for spheroid cultures in 96-well ULA plates. Two different cell types were used in this study: Normal Human Dermal Fibroblasts (NHDFneo) and the colon cancer cell line HCT-116. Both cell types efficiently form spheroids in ULA plates. Also in RAFT™ 3D cultures HCT-116 cells build compact aggregate-like structures, whereas NHDFneo grow in as individual cells interspersed in the collagen scaffold. By elongating the first step of the Vialight™ Assay, the lysis step, from 10 minutes to 30 minutes, a linear performance of the assay for cell numbers of up to 96,000 cells in the 96-well format and 480,000 cells in the 24-well format could be obtained for RAFT™ cultures. For spheroid cultures an extension of the lysis time to 60 minutes was required to obtain efficient lysis of spheroids with a diameter of up to 400μm, as confirmed by CalceinAM and propidium iodide staining. In summary this presentation shows that analyzing cells in 3D cultures can easily and routinely be done by slightly adjusting standard 2D cell culture assays like the ViaLight™ Assay. Citation Format: Stefanie Buesch, John Langer, Sabine Schaepermeier, Lubna Hussain, Jeffrey Bergeron, Volker Vogel, Jenny Schroeder. Analyzing cell viability in 3-D tissue models with the ViaLight™ plus cell proliferation and cytotoxicity bioassay. [abstract]. In: Proceedings of the 107th Annual Meeting of the American Association for Cancer Research; 2016 Apr 16-20; New Orleans, LA. Philadelphia (PA): AACR; Cancer Res 2016;76(14 Suppl):Abstract nr 607.
- 17 February 2014
- Published by Wiley in Engineering in Life Sciences
- Vol. 14 (3) , 292-303
Scale‐up of adipose tissue‐derived mesenchymal stem cell production in stirred single‐use bioreactors under low‐serum conditions
Suspension cultures, in which human mesenchymal stem cells are cultivated on microcarriers in scalable single‐use stirred bioreactor types, have been shown to be a promising alternative to planar flask cultures. However, stirred single‐use bioreactors were originally developed for production processes with robust, permanent cell lines. Human mesenchymal stem cells are adherent primary cells and thus expanding them in such bioreactor systems imposes more stringent requirements on bioreactor systems. For low‐serum conditions (5%) and different types of stirred single‐use bioreactors, a suspension criteria‐based approach for expanding human adipose tissue‐derived mesenchymal stem cells (hASCs) from milliliter to pilot scale was successfully developed. For process scale‐up, experimental and numerical investigations were performed to (i) predict optimum impeller speeds, (ii) determine the main engineering parameters (local shear stress, turbulent dissipation rate, Kolmogorov microscale), and (iii) verify suspension criteria NS1 and NS1u for rapid process transfer from 100 mL to 2 L and 35 L cultures. Using optimized medium‐microcarrier combinations as well as NS1 and NS1u as scale‐up factors, total hASC quantities between 3 × 107 (100 mL scale) and 1 × 1010 (35 L scale) were obtained. The cell quantities obtained are the highest reported to date for scalable single‐use bioreactors under low‐serum conditions.
- 17 February 2014
- Published by Wiley in Engineering in Life Sciences
- Vol. 14 (3) , 292-303
Scale‐up of adipose tissue‐derived mesenchymal stem cell production in stirred single‐use bioreactors under low‐serum conditions
Suspension cultures, in which human mesenchymal stem cells are cultivated on microcarriers in scalable single‐use stirred bioreactor types, have been shown to be a promising alternative to planar flask cultures. However, stirred single‐use bioreactors were originally developed for production processes with robust, permanent cell lines. Human mesenchymal stem cells are adherent primary cells and thus expanding them in such bioreactor systems imposes more stringent requirements on bioreactor systems. For low‐serum conditions (5%) and different types of stirred single‐use bioreactors, a suspension criteria‐based approach for expanding human adipose tissue‐derived mesenchymal stem cells (hASCs) from milliliter to pilot scale was successfully developed. For process scale‐up, experimental and numerical investigations were performed to (i) predict optimum impeller speeds, (ii) determine the main engineering parameters (local shear stress, turbulent dissipation rate, Kolmogorov microscale), and (iii) verify suspension criteria NS1 and NS1u for rapid process transfer from 100 mL to 2 L and 35 L cultures. Using optimized medium‐microcarrier combinations as well as NS1 and NS1u as scale‐up factors, total hASC quantities between 3 × 107 (100 mL scale) and 1 × 1010 (35 L scale) were obtained. The cell quantities obtained are the highest reported to date for scalable single‐use bioreactors under low‐serum conditions.
- Open Access
- 4 December 2013
- Published by Springer Nature in BMC Proceedings
- Vol. 7 (S6) , P2
Expansion of mesenchymal adipose-tissue derived stem cells in a stirred single-use bioreactor under low-serum conditions
- 4 December 2013
- Published by Springer Nature in BMC Proceedings
- Vol. 7 (S6) , P2
Open AccessExpansion of mesenchymal adipose-tissue derived stem cells in a stirred single-use bioreactor under low-serum conditions
- 10 August 2013
- Published by Springer Nature
- Vol. 138, 61-97
Therapeutic Human Cells: Manufacture for Cell Therapy/Regenerative Medicine
Human primary cells (e.g. adult stem cells) as well as differentiated cells, including those of the immune system, have been found to be therapeutically useful and free of ethical concerns. Several products have received market authorization and numerous promising clinical trials are underway. We believe that such primary therapeutic cells will dominate the market for cell therapy applications for the foreseeable future. Consequently, production of such cellular products warrants attention and needs to be a fully controlled pharmaceutical process. Thus, where possible, such production should change from manufacture towards a truly scalable industrialized process for both allogeneic and autologous products. Here, we discuss manufacturing aspects of both autogeneic and allogeneic products, review the field, and provide historical context.
- 10 August 2013
- Published by Springer Nature
- Vol. 138, 61-97
Therapeutic Human Cells: Manufacture for Cell Therapy/Regenerative Medicine
Human primary cells (e.g. adult stem cells) as well as differentiated cells, including those of the immune system, have been found to be therapeutically useful and free of ethical concerns. Several products have received market authorization and numerous promising clinical trials are underway. We believe that such primary therapeutic cells will dominate the market for cell therapy applications for the foreseeable future. Consequently, production of such cellular products warrants attention and needs to be a fully controlled pharmaceutical process. Thus, where possible, such production should change from manufacture towards a truly scalable industrialized process for both allogeneic and autologous products. Here, we discuss manufacturing aspects of both autogeneic and allogeneic products, review the field, and provide historical context.
- 15 April 2013
- Published by American Association for Cancer Research (AACR)
- Vol. 74, 3485
Abstract 1142: Systematic review and meta-analysis of immunohistochemical diagnostic markers for pancreatic ductal adenocarcinoma.
Cell lines isolated from tumors are an important tool to study cancer in vitro. They can be used for drug development as well as for understanding the basic mechanisms underlying cancer. Transfection of cancer cell lines with different molecules like plasmid DNA, siRNA or mRNA is often an integral part for this kind of research.
- 15 April 2013
- Published by American Association for Cancer Research (AACR)
- Vol. 74, 3485
Abstract 1142: Systematic review and meta-analysis of immunohistochemical diagnostic markers for pancreatic ductal adenocarcinoma.
Cell lines isolated from tumors are an important tool to study cancer in vitro. They can be used for drug development as well as for understanding the basic mechanisms underlying cancer. Transfection of cancer cell lines with different molecules like plasmid DNA, siRNA or mRNA is often an integral part for this kind of research.