  • New Generic Model of DFG-Based Wind Turbines for RMS-Type Simulation

    by Jens Fortmann, Stephan Engelhardt, Jorg Kretschmann, Christian Feltes, Istvan Erlich

    New requirements for the validation of simulation models based on measurements in many grid codes show that existing generic approaches for generator and converter models of doubly fed generator systems (DFG) may not be accurate enough. The authors show that by applying a detailed analysis of the generator equations and the converter control design, a reduction of the model complexity is possible while maintaining a high level of accuracy. The generator model presented in this paper allows an improved representation of the stationary and dynamic response of wind turbines equipped with DFG systems especially during grid faults and during voltage recovery. The model is designed to represent modern DFG systems independently of vendor specific hardware and software. The results of simulations are compared to measurements of a voltage dip involving wind turbines. The generator model has been proposed as extension to the WECC/IEEE generator models and has been accepted as reference for IEC TC88 working group 27 (standard IEC 61400-27-1) on modeling and model validation of wind turbines.


  • Improving the Reactive Power Capability of the DFIG-Based Wind Turbine During Operation Around the Synchronous Speed

    by Muhamad Zahim Sujod, Istvan Erlich, Stephan Engelhardt

    The doubly fed induction generator (DFIG) equipped with self-commutated insulated gate bipolar transistor (IGBT) voltage source converter (VSC) is one of the most popular topologies used in wind power systems. It has the ability to control active and reactive power independently. The reactive power capability is subject to several limitations which change with the operating point. Around synchronous operating point, a special attention is needed since the limitation of maximum junction temperature of the IGBTs cause a reduction on maximum permissible output current at the rotor side. This paper investigates the thermal behavior of the converter using semiconductor losses and thermal model based on the IGBT manufacturer datasheet. Different pulse-width modulation (PWM) types, including continuous and discontinuous types are applied and the results of reactive power capability are compared. Simulation results show that appropriate selection of PWM type is necessary at around synchronous speed to increase the maximum permissible rotor current as well as reactive power capability.


  • Capability and limitations of DFIG based wind turbines concerning negative sequence control

    by S. Engelhardt, J. Kretschmann, J. Fortmann, F. Shewarega, I. Erlich, T. Neumann

    Modern wind turbine systems based on doubly-fed induction generator (DFIG) technology offer negative sequence control capability during grid faults or unsymmetrical system operation. This paper deals especially with the effects of current and voltage limitation of a typically rated converter system design based on positive sequence control requirements. At first a short summary of the most common alternative negative sequence control objectives is given. Then the corresponding rotor side converter (RSC) control algorithms are described. This is followed by typical characteristics of current capabilities as well as voltage constraints. Finally detailed calculations regarding control possibilities and limitations in the positive and negative sequence are shown.


  • Wind turbine modeling, LVRT field test and certification

    by Jens Fortmann, Lijun Cai, Stephan Engelhardt, Jorg Kretschmann

    The need to validate wind turbine models for the use in grid integration studies is addressed in an increasing number of grid codes. In several countries (Spain, Australia, UK, Germany) requirements for simulation models are now required for the grid access of wind turbines. In Germany, triggered by the new renewable energy law (EEG), a guideline for validating electrical simulation models of wind turbines has been designed. The model validation approach chosen will be described. The aim of this validation approach is to quantify the error between measurement and simulation. This is necessary in order to give a reliable figure for the model uncertainty for the use of the model in studies. Results of FRT-measurements with balanced and unbalanced faults will be compared to the results of an RMS DFIG model. It can be shown that the validation approach can be applied with success both to balanced and unbalanced faults.


  • Negative sequence control of DFG based wind turbines

    by S. Engelhardt, J. Kretschmann, J. Fortmann, F. Shewarega, I. Erlich, C. Feltes

    The paper deals with the control of negative sequence voltages and currents in wind turbine systems caused by grid fault or unsymmetrical system operation. The ensuing stator and rotor currents lead to additional thermal stress. Moreover, the interaction between the different sequence components of the current and voltage in the stator as well as rotor cause oscillating torque leading to mechanical strain on the drive-train. A control approach for limiting or eliminating the negative sequence current and the resulting alternating torque is discussed. This is followed by the description and derivation of the rotor side converter (RSC) for the positive as well as negative sequence current controllers. The procedure is repeated for the grid side converter (GSC), and the limitations imposed on the controllers by practical operational considerations are explained. On the basis of simulation examples using representative wind turbine system data, the effectiveness of the proposed control methods has been demonstrated.


  • Reactive Power Capability of Wind Turbines Based on Doubly Fed Induction Generators

    by Stephan Engelhardt, Istvan Erlich, Christian Feltes, Jörg Kretschmann, Fekadu Shewarega

    With the increasing penetration of wind turbines (WTs) grid utilities require extended reactive power supply capability not only during voltage dips but also in steady-state operation. WTs with doubly fed induction generators (DFIG) are able to control active and reactive power independently. The reactive power capability is subject to several limitations resulting from the voltage, current, and speed, which change with the operating point. This paper discusses the steady-state reactive power loading capability of DFIG-based WTs by taking into account the most important physical phenomena restricting the reactive power supply of DFIG-based WT systems. The active-reactive power diagram is systematically derived by considering the typical power-speed relationship and converter loading limits. The authors discuss also some special operating modes limiting the reactive power capability together with aspects of modeling and control that give rise to these limitations.