Hokkaido Orthopedic Surgery Memorial Hospital
Type
HealthcareLocations
Sapporo, JapanLatest Publications
- Open Access
- 28 May 2026
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 31 (6) , 1235-1239
Incidence of periprosthetic femoral fracture after total hip arthroplasty using the exeter stem: A retrospective multicenter cohort study in Japan
- 28 May 2026
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 31 (6) , 1235-1239
Open AccessIncidence of periprosthetic femoral fracture after total hip arthroplasty using the exeter stem: A retrospective multicenter cohort study in Japan
- 28 December 2025
- Published by Elsevier in The Spine Journal
- Vol. 26 (4) , 685-692
Lower extremity deep sensory disturbance as a risk factor for postlaminoplasty kyphosis in patients with cervical ossification of the posterior longitudinal ligament
- 28 December 2025
- Published by Elsevier in The Spine Journal
- Vol. 26 (4) , 685-692
Lower extremity deep sensory disturbance as a risk factor for postlaminoplasty kyphosis in patients with cervical ossification of the posterior longitudinal ligament
- Open Access
- 13 September 2025
- Published by Elsevier in JPRAS Open
- Vol. 46, 216-229
Prophylactic versus reactive leech therapy for venous congestion after fingertip replantation: A retrospective comparative study and literature review
- 13 September 2025
- Published by Elsevier in JPRAS Open
- Vol. 46, 216-229
Open AccessProphylactic versus reactive leech therapy for venous congestion after fingertip replantation: A retrospective comparative study and literature review
- Open Access
- 4 June 2025
- Published by Springer Nature in European Spine Journal
- Vol. 34 (8) , 3304-3313
Accuracy of cervical pedicle screw placement using a patient-specific template guide system and risk factor analysis for screw perforation: CT-based evaluation of 437 screws
Purpose Cervical pedicle screws (CPS) inserted with template-guided systems (TGS) have a low perforation rate. However, only a few case studies have been reported, and the risk factors for perforation remain unknown. This study aimed to evaluate the accuracy of CPS placement using TGS in a large case series and analyze the risk factors for CPS perforation. Methods This was a retrospective clinical evaluation of prospectively enrolled patients. Eighty consecutive patients who underwent CPS insertion using TGS were included in the study. Overall, 437 CPS were inserted using TGS. Computed tomography was used to evaluate CPS positions and radiographic parameters of CPS and vertebrae. Furthermore, comparisons of patient background factors and radiographic parameters were performed between the perforated and non-perforated screw groups. Results A total of 413 (94.5%) screws were completely inside the pedicle, 22 (5.0%) screws deviated by < 2 mm, and 2 (0.5%) screws deviated by > 2 mm and < 4 mm. Therefore, 435 (99.5%) screws were considered clinically acceptable. The perforation rate was the highest in C4 (12.5%). No neurovascular injury was observed. In comparisons between the perforated screw group and the non-perforated screw group, low height, low weight, low BMI, female sex, fellow surgeon, and narrow pedicle were considered as risk factors for CPS perforation using TGS. Conclusion CPS placement using the TGS showed very high clinical accuracy. Body size, sex, surgeon’s experience, and pedicle width may affect the accuracy of CPS placement using TGS.
- 4 June 2025
- Published by Springer Nature in European Spine Journal
- Vol. 34 (8) , 3304-3313
Open AccessAccuracy of cervical pedicle screw placement using a patient-specific template guide system and risk factor analysis for screw perforation: CT-based evaluation of 437 screws
Purpose Cervical pedicle screws (CPS) inserted with template-guided systems (TGS) have a low perforation rate. However, only a few case studies have been reported, and the risk factors for perforation remain unknown. This study aimed to evaluate the accuracy of CPS placement using TGS in a large case series and analyze the risk factors for CPS perforation. Methods This was a retrospective clinical evaluation of prospectively enrolled patients. Eighty consecutive patients who underwent CPS insertion using TGS were included in the study. Overall, 437 CPS were inserted using TGS. Computed tomography was used to evaluate CPS positions and radiographic parameters of CPS and vertebrae. Furthermore, comparisons of patient background factors and radiographic parameters were performed between the perforated and non-perforated screw groups. Results A total of 413 (94.5%) screws were completely inside the pedicle, 22 (5.0%) screws deviated by < 2 mm, and 2 (0.5%) screws deviated by > 2 mm and < 4 mm. Therefore, 435 (99.5%) screws were considered clinically acceptable. The perforation rate was the highest in C4 (12.5%). No neurovascular injury was observed. In comparisons between the perforated screw group and the non-perforated screw group, low height, low weight, low BMI, female sex, fellow surgeon, and narrow pedicle were considered as risk factors for CPS perforation using TGS. Conclusion CPS placement using the TGS showed very high clinical accuracy. Body size, sex, surgeon’s experience, and pedicle width may affect the accuracy of CPS placement using TGS.
- 26 September 2024
- Published by Elsevier in The Spine Journal
- Vol. 25 (1) , 80-90
Adipokine dysregulation as an underlying pathology for diffuse ectopic ossification of spinal posterior longitudinal ligament in patients with obesity
- 26 September 2024
- Published by Elsevier in The Spine Journal
- Vol. 25 (1) , 80-90
Adipokine dysregulation as an underlying pathology for diffuse ectopic ossification of spinal posterior longitudinal ligament in patients with obesity
- Open Access
- 1 September 2024
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 10 (3) , 468-478
Real-world clinical accuracy of long cortical bone trajectory screw placement using a patient-specific template guide
Background: Cortical bone trajectory (CBT) screws can be very reliable anchors if inserted precisely anterior to the vertebral body; however, their trajectory is narrow, and malpositioning of the screw is not rare, especially for surgeons who are not familiar with the CBT screw. Patient-specific template guides are a solution to this problem; however, their accuracy and usefulness in clinical settings remain unclear. The aim of the present study was to evaluate the accuracy of long CBT placement using a patient-specific screw-guide system. Methods: This research involved a retrospective clinical evaluation of patients who had been enrolled prospectively. One hundred consecutive patients who underwent posterior lumbar spinal fusion using the guide system performed by three experienced spine surgeons were included. Initially, the placement of the CBT screws was mapped out in three dimensions utilizing simulation software. Prior to the surgery, a specific screw guide was designed for each vertebra. Using these guides, a total of 412 screws were placed. To assess any perforation of the pedicle and to compare the discrepancies between the intended and the actual positions of the screws, postoperative computed tomography (CT) scans were utilized. Results: Overall, 382 screws (92.7%) were fully inside the pedicle (L2–5) and there was no incidence of neurovascular injuries. The mean depth of the screw in the vertebral body (% depth) was 60.9%±8.1% and the mean % depth deviation between planned screws and actual screw was 9.6%±7.1% in total. In all vertebrae, the mean % depth was approximately 10% smaller for the actual screws than the planned screws. The mean sagittal and transverse angular deviations between the planned screws and actual screws were 2.30±1.87° and 1.89±1.26°, respectively. Overall, deviation in the sagittal angle tended to be cranial. Conclusions: We demonstrated that a patient-specific screw guide is useful for supporting precise long CBT screw insertion into the lumbar spine in a clinical setting. This patient-specific template guide could be a potential solution to accurately insert long CBT screws and reduce complications, even for surgeons who are not experienced in the CBT technique.
- 1 September 2024
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 10 (3) , 468-478
Open AccessReal-world clinical accuracy of long cortical bone trajectory screw placement using a patient-specific template guide
Background: Cortical bone trajectory (CBT) screws can be very reliable anchors if inserted precisely anterior to the vertebral body; however, their trajectory is narrow, and malpositioning of the screw is not rare, especially for surgeons who are not familiar with the CBT screw. Patient-specific template guides are a solution to this problem; however, their accuracy and usefulness in clinical settings remain unclear. The aim of the present study was to evaluate the accuracy of long CBT placement using a patient-specific screw-guide system. Methods: This research involved a retrospective clinical evaluation of patients who had been enrolled prospectively. One hundred consecutive patients who underwent posterior lumbar spinal fusion using the guide system performed by three experienced spine surgeons were included. Initially, the placement of the CBT screws was mapped out in three dimensions utilizing simulation software. Prior to the surgery, a specific screw guide was designed for each vertebra. Using these guides, a total of 412 screws were placed. To assess any perforation of the pedicle and to compare the discrepancies between the intended and the actual positions of the screws, postoperative computed tomography (CT) scans were utilized. Results: Overall, 382 screws (92.7%) were fully inside the pedicle (L2–5) and there was no incidence of neurovascular injuries. The mean depth of the screw in the vertebral body (% depth) was 60.9%±8.1% and the mean % depth deviation between planned screws and actual screw was 9.6%±7.1% in total. In all vertebrae, the mean % depth was approximately 10% smaller for the actual screws than the planned screws. The mean sagittal and transverse angular deviations between the planned screws and actual screws were 2.30±1.87° and 1.89±1.26°, respectively. Overall, deviation in the sagittal angle tended to be cranial. Conclusions: We demonstrated that a patient-specific screw guide is useful for supporting precise long CBT screw insertion into the lumbar spine in a clinical setting. This patient-specific template guide could be a potential solution to accurately insert long CBT screws and reduce complications, even for surgeons who are not experienced in the CBT technique.
- Open Access
- 12 June 2024
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 30 (2) , 346-351
Four stem fractures in a 12-year follow-up study of 9,135 patients with Exeter hip stems at seven teaching facilities in Japan
- 12 June 2024
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 30 (2) , 346-351
Open AccessFour stem fractures in a 12-year follow-up study of 9,135 patients with Exeter hip stems at seven teaching facilities in Japan
- Open Access
- 1 June 2024
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 34 (6) , 2949-2955
Multi-center study of use of the Exeter stem in Japan: a 10-year follow-up report
Purpose: Since the introduction of the Exeter stem for clinical use in Japan in 1996, the number of stems used has continued to rise owing to its favorable results. We investigated the outcomes of patients who had previously undergone total hip arthroplasty with the Exeter stem in Japan with a 10-year + follow-up period. Methods: This retrospective cohort study used clinical and radiographic data of 682 cases of primary total hip arthroplasty performed using the Exeter stem. Results: The mean postoperative follow-up period was 13.3 years. Femoral-side revision was required in 14 hips, with no cases of aseptic stem loosening-associated revision observed. Kaplan–Meier survival analysis predicted 97.3% 15-year survival when revision for any reason was used as the endpoint. Conclusion: The obtained findings suggested the excellent long-term stability of the Exeter stem for primary total hip arthroplasty in Japan.
- 1 June 2024
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 34 (6) , 2949-2955
Open AccessMulti-center study of use of the Exeter stem in Japan: a 10-year follow-up report
Purpose: Since the introduction of the Exeter stem for clinical use in Japan in 1996, the number of stems used has continued to rise owing to its favorable results. We investigated the outcomes of patients who had previously undergone total hip arthroplasty with the Exeter stem in Japan with a 10-year + follow-up period. Methods: This retrospective cohort study used clinical and radiographic data of 682 cases of primary total hip arthroplasty performed using the Exeter stem. Results: The mean postoperative follow-up period was 13.3 years. Femoral-side revision was required in 14 hips, with no cases of aseptic stem loosening-associated revision observed. Kaplan–Meier survival analysis predicted 97.3% 15-year survival when revision for any reason was used as the endpoint. Conclusion: The obtained findings suggested the excellent long-term stability of the Exeter stem for primary total hip arthroplasty in Japan.
- 9 April 2024
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 50 (5) , 574-580
Clinical Outcomes of Total Wrist Arthroplasty in Patients With Rheumatoid Arthritis: Minimum 10-Year Follow-Up Study
- 9 April 2024
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 50 (5) , 574-580
Clinical Outcomes of Total Wrist Arthroplasty in Patients With Rheumatoid Arthritis: Minimum 10-Year Follow-Up Study