Bracco (Italy)

Types
Company, FunderLocations
Milan, ItalyRelationships
Latest Publications
- Open Access
- 9 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (16) , 2514
Comparison of LC–MS/MS and CLIA Methods for Vitamin D Measurement in an Unselected Outpatient Cohort: Statistical Evaluation and Impact on Clinical Classification
Background: This study aimed to compare a chemiluminescence immunoassay (CLIA; Siemens Atellica IM 1600) with an automated liquid chromatography–tandem mass spectrometry (LC–MS/MS) analyser (Thermo Scientific Cascadion SM) for serum 25-hydroxyvitamin D [25(OH)D] measurement in unselected outpatients, and its impact on clinical classification. Methods: 25(OH)D was measured on 1064 paired serum samples (828 women, 236 men; age 3–111 years); both platforms participated in the Vitamin D Standardisation Program (VDSP). Agreement was assessed by the Wilcoxon signed-rank test, Passing–Bablok regression, Bland–Altman analysis on log-transformed values, Breusch–Pagan testing for heteroscedasticity, consistency-based intraclass correlation coefficient (ICC), Lin’s concordance correlation coefficient, and Cohen’s kappa with McNemar’s test on six- and two-category clinical classifications. Results: Methods differed significantly (). Passing–Bablok regression showed proportional bias (slope 1.33; 95% confidence interval [CI], 1.28–1.38; LC–MS/MS higher). Consistency ICC was 0.928 (95% CI, 0.919–0.936). Log-Bland–Altman bias was 35.5% (limits of agreement, % to %; heteroscedasticity, ). Cohen’s kappa was 0.32 unweighted and 0.72 weighted on six clinical categories, and 0.56 on a two-class scheme (McNemar ). In discordant pairs, CLIA classified deficiency 118-fold more often than LC–MS/MS. Conclusions: In our study, despite preserved rank ordering, a non-linear concentration-dependent bias and different limits of agreement caused systematic differences in the classification of vitamin D deficiency. Adoption of automated LC–MS/MS can substantially reclassify outpatients toward sufficiency, with implications for supplementation and laboratory harmonisation.- 9 August 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (16) , 2514
Open AccessComparison of LC–MS/MS and CLIA Methods for Vitamin D Measurement in an Unselected Outpatient Cohort: Statistical Evaluation and Impact on Clinical Classification
Background: This study aimed to compare a chemiluminescence immunoassay (CLIA; Siemens Atellica IM 1600) with an automated liquid chromatography–tandem mass spectrometry (LC–MS/MS) analyser (Thermo Scientific Cascadion SM) for serum 25-hydroxyvitamin D [25(OH)D] measurement in unselected outpatients, and its impact on clinical classification. Methods: 25(OH)D was measured on 1064 paired serum samples (828 women, 236 men; age 3–111 years); both platforms participated in the Vitamin D Standardisation Program (VDSP). Agreement was assessed by the Wilcoxon signed-rank test, Passing–Bablok regression, Bland–Altman analysis on log-transformed values, Breusch–Pagan testing for heteroscedasticity, consistency-based intraclass correlation coefficient (ICC), Lin’s concordance correlation coefficient, and Cohen’s kappa with McNemar’s test on six- and two-category clinical classifications. Results: Methods differed significantly (). Passing–Bablok regression showed proportional bias (slope 1.33; 95% confidence interval [CI], 1.28–1.38; LC–MS/MS higher). Consistency ICC was 0.928 (95% CI, 0.919–0.936). Log-Bland–Altman bias was 35.5% (limits of agreement, % to %; heteroscedasticity, ). Cohen’s kappa was 0.32 unweighted and 0.72 weighted on six clinical categories, and 0.56 on a two-class scheme (McNemar ). In discordant pairs, CLIA classified deficiency 118-fold more often than LC–MS/MS. Conclusions: In our study, despite preserved rank ordering, a non-linear concentration-dependent bias and different limits of agreement caused systematic differences in the classification of vitamin D deficiency. Adoption of automated LC–MS/MS can substantially reclassify outpatients toward sufficiency, with implications for supplementation and laboratory harmonisation. - Open Access
- 4 July 2026
- Published by Springer Nature in Neuroradiology
- Vol. 68 (9) , 3059-3069
Deep learning for contrast-enhanced MRI in pediatric brain imaging
Purpose: A deep learning algorithm for contrast amplification in brain MRI, trained exclusively on adult data, was tested for cross-population generalization to pediatric patients, including subjects aged 0–2 years. Methods: A retrospective monocentric dataset (n = 22 cases) comprising pediatric patients (0–17 years old) diagnosed with various brain tumors was used to evaluate the algorithm, which takes T1-weighted pre- and standard post-contrast images as input and generates an output image with amplified contrast, further post-processed with an HDR algorithm. Quantitative comparisons between standard and amplified images were performed using contrast-to-noise ratio (CNR), contrast enhancement percentage (CEP), and lesion-to-background ratio (LBR). Three neuroradiologists performed qualitative assessment using a 4-point Likert scale, focusing on lesion contrast and delineation. Anatomical similarity was assessed using SSIM and log-Jacobian range. Statistical significance was evaluated using two-tailed paired t-tests. Results: Compared to standard-dose images, contrast-amplified images showed significantly higher values for CNR (+ 186.5%), LBR (+ 61.9%), and CEP (+ 110.4%). Qualitative assessments demonstrated comparable lesion visualization, with improvements observed in selected cases. Reader 1 preferred the contrast-amplified image in 12 of 22 cases (54.5%), reader 2 favored it in 18 of 22 cases (81.8%) and reader 3 in 13/22 cases (59.1%). One reader reported improved overall image quality (mean score: 3.95 vs. 3.73). The average SSIM between amplified and standard-dose images was 0.98, and any significant anatomical differences were highlighted by the log-Jacobian range ( p- value = 0.556). Conclusion: An algorithm for contrast amplification based on deep learning, trained with adult data, significantly enhances quantitative contrast metrics in images from pediatric patients. It is preferred over standard-dose images in the majority of cases when used for pediatric brain MRI, indicating its promising application for cross-population applicability.
- 4 July 2026
- Published by Springer Nature in Neuroradiology
- Vol. 68 (9) , 3059-3069
Open AccessDeep learning for contrast-enhanced MRI in pediatric brain imaging
Purpose: A deep learning algorithm for contrast amplification in brain MRI, trained exclusively on adult data, was tested for cross-population generalization to pediatric patients, including subjects aged 0–2 years. Methods: A retrospective monocentric dataset (n = 22 cases) comprising pediatric patients (0–17 years old) diagnosed with various brain tumors was used to evaluate the algorithm, which takes T1-weighted pre- and standard post-contrast images as input and generates an output image with amplified contrast, further post-processed with an HDR algorithm. Quantitative comparisons between standard and amplified images were performed using contrast-to-noise ratio (CNR), contrast enhancement percentage (CEP), and lesion-to-background ratio (LBR). Three neuroradiologists performed qualitative assessment using a 4-point Likert scale, focusing on lesion contrast and delineation. Anatomical similarity was assessed using SSIM and log-Jacobian range. Statistical significance was evaluated using two-tailed paired t-tests. Results: Compared to standard-dose images, contrast-amplified images showed significantly higher values for CNR (+ 186.5%), LBR (+ 61.9%), and CEP (+ 110.4%). Qualitative assessments demonstrated comparable lesion visualization, with improvements observed in selected cases. Reader 1 preferred the contrast-amplified image in 12 of 22 cases (54.5%), reader 2 favored it in 18 of 22 cases (81.8%) and reader 3 in 13/22 cases (59.1%). One reader reported improved overall image quality (mean score: 3.95 vs. 3.73). The average SSIM between amplified and standard-dose images was 0.98, and any significant anatomical differences were highlighted by the log-Jacobian range ( p- value = 0.556). Conclusion: An algorithm for contrast amplification based on deep learning, trained with adult data, significantly enhances quantitative contrast metrics in images from pediatric patients. It is preferred over standard-dose images in the majority of cases when used for pediatric brain MRI, indicating its promising application for cross-population applicability.
- Open Access
- 3 April 2026
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 208, 111665
Identifying myocardial regions perfused by coronary arteries through detailed human microvasculature data
- 3 April 2026
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 208, 111665
Open AccessIdentifying myocardial regions perfused by coronary arteries through detailed human microvasculature data
- Open Access
- 23 March 2026
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 61 (12) , 832-841
Efficacy of a Novel Dimeric Macrocyclic Gadolinium Chelate With High Relaxivity in Preclinical Models of Neurological and Oncological Pathologies
Background: Gadolinium-based contrast agents (GBCAs) are crucial for enhancing MRI contrast, especially in neurological and oncological imaging. Achieving high relaxivity is a primary focus in contrast media research. Recently, digadoglucitol, the first dimeric macrocyclic gadolinium complex, was introduced, offering significantly higher relaxivity compared with first-generation commercial macrocyclic GBCAs. Purpose: This study assesses the performance of digadoglucitol in preclinical models of neurological and oncological diseases. It explores whether digadoglucitol provides comparable diagnostic efficacy at half the dose and superior contrast enhancement at the full standard dose compared with gadoterate meglumine and gadobutrol. Material and Methods: All animal experiments and preclinical procedures adhered to national and international regulations. The study involved models of glioma, meningioma, ischemia, and breast adenocarcinoma, for a total of 112 animals. Digadoglucitol was administered at doses of 0.1 mmol Gd/kg and 0.05 mmol Gd/kg, whereas gadoterate meglumine and gadobutrol were given at 0.1 mmol Gd/kg. MRI sessions assessed signal enhancement and contrast-to-noise ratio (CNR) before and after contrast-agent administration. Results: All pathologic models were accurately localized with consistent volumes across treatment groups. Tumour malignancy and ischemic lesions were confirmed by histologic analysis using standard haematoxylin-eosin staining and established pathologic criteria. Quantitative analysis revealed that both half and full doses of digadoglucitol produced significant signal enhancement and CNR in glioma, meningioma, ischemia, and breast models. The enhancement and CNR values were comparable (at half-dose) or exceeded (at full-dose) those achieved with gadoterate meglumine and gadobutrol. Statistical analysis confirmed the significance of these results. Conclusion: Digadoglucitol shows high diagnostic efficacy in preclinical models of neurological and oncological diseases. It delivers comparable effectiveness at half the dose and superior contrast enhancement at the full standard dose compared with established GBCAs. These preclinical findings suggest that digadoglucitol is a promising contrast agent to be considered for clinical translation, potentially allowing for reduced dosage while maintaining or improving diagnostic accuracy.
- 23 March 2026
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 61 (12) , 832-841
Open AccessEfficacy of a Novel Dimeric Macrocyclic Gadolinium Chelate With High Relaxivity in Preclinical Models of Neurological and Oncological Pathologies
Background: Gadolinium-based contrast agents (GBCAs) are crucial for enhancing MRI contrast, especially in neurological and oncological imaging. Achieving high relaxivity is a primary focus in contrast media research. Recently, digadoglucitol, the first dimeric macrocyclic gadolinium complex, was introduced, offering significantly higher relaxivity compared with first-generation commercial macrocyclic GBCAs. Purpose: This study assesses the performance of digadoglucitol in preclinical models of neurological and oncological diseases. It explores whether digadoglucitol provides comparable diagnostic efficacy at half the dose and superior contrast enhancement at the full standard dose compared with gadoterate meglumine and gadobutrol. Material and Methods: All animal experiments and preclinical procedures adhered to national and international regulations. The study involved models of glioma, meningioma, ischemia, and breast adenocarcinoma, for a total of 112 animals. Digadoglucitol was administered at doses of 0.1 mmol Gd/kg and 0.05 mmol Gd/kg, whereas gadoterate meglumine and gadobutrol were given at 0.1 mmol Gd/kg. MRI sessions assessed signal enhancement and contrast-to-noise ratio (CNR) before and after contrast-agent administration. Results: All pathologic models were accurately localized with consistent volumes across treatment groups. Tumour malignancy and ischemic lesions were confirmed by histologic analysis using standard haematoxylin-eosin staining and established pathologic criteria. Quantitative analysis revealed that both half and full doses of digadoglucitol produced significant signal enhancement and CNR in glioma, meningioma, ischemia, and breast models. The enhancement and CNR values were comparable (at half-dose) or exceeded (at full-dose) those achieved with gadoterate meglumine and gadobutrol. Statistical analysis confirmed the significance of these results. Conclusion: Digadoglucitol shows high diagnostic efficacy in preclinical models of neurological and oncological diseases. It delivers comparable effectiveness at half the dose and superior contrast enhancement at the full standard dose compared with established GBCAs. These preclinical findings suggest that digadoglucitol is a promising contrast agent to be considered for clinical translation, potentially allowing for reduced dosage while maintaining or improving diagnostic accuracy.
- Open Access
- 26 February 2026
- Published by Royal Society of Chemistry (RSC) in Green Chemistry
- Vol. 28 (13) , 5701-5708
A combined microwave/continuous flow approach for the iodination of anilines and consecutive Mizoroki–Heck cross-coupling
We report a modular, microwave-assisted continuous-flow approach for the selective iodination of unprotected anilines for API synthesis, achieving control of regioselectivity, and over-halogenation, avoiding the need for a protecting group.
- 26 February 2026
- Published by Royal Society of Chemistry (RSC) in Green Chemistry
- Vol. 28 (13) , 5701-5708
Open AccessA combined microwave/continuous flow approach for the iodination of anilines and consecutive Mizoroki–Heck cross-coupling
We report a modular, microwave-assisted continuous-flow approach for the selective iodination of unprotected anilines for API synthesis, achieving control of regioselectivity, and over-halogenation, avoiding the need for a protecting group.
- Open Access
- 10 December 2025
- Published by Springer Nature in World Wide Web
- Vol. 29 (1) , 4
Exploring UNet-based models for prostate lesion segmentation from multi-sequence MRI (T2W, ADC, DWI)
Accurate delineation of lesions in prostate MRI is crucial for the diagnosis of prostate cancer. Manual segmentation is time-consuming, requires advanced medical expertise, and is subject to inter-operator variability. Automatic lesion segmentation therefore represents a valuable tool to support clinicians by reducing workload, minimizing observer bias, and enabling more consistent image analysis. In this work, we investigated the performance of four deep learning architectures for prostate lesion segmentation: nnU-Net, DenseUNet, SegResUNet, and U-Net. Unlike many existing studies that rely on publicly available data, we constructed a dedicated dataset to better capture real-world variability and challenges. The dataset, comprising T2-weighted (T2W), apparent diffusion coefficient (ADC), and diffusion-weighted imaging (DWI) sequences, was carefully annotated by medical experts to ensure high-quality labels. Training was performed using the full combination of these modalities. Two cohorts were considered based on lesion severity, as defined by PI-RADS (Prostate Imaging–Reporting and Data System) scores: one with only PI-RADS 4–5 lesions (151 patients), and another including PI-RADS 3 cases, totaling 209 patients. Evaluation was conducted both on a patient-by-patient basis and in a consolidated all-patient setting. In the patient-level analysis, nnU-Net achieved the highest Dice similarity coefficient (DSC) of 0.60 when trained on PI-RADS 4–5 lesions, while in the all-patient analysis, DenseUNet attained a DSC of 0.57 on the same dataset. These results are within the range reported in recent prostate lesion segmentation studies, and in some cases are comparable to or exceed those obtained with substantially larger datasets.
- 10 December 2025
- Published by Springer Nature in World Wide Web
- Vol. 29 (1) , 4
Open AccessExploring UNet-based models for prostate lesion segmentation from multi-sequence MRI (T2W, ADC, DWI)
Accurate delineation of lesions in prostate MRI is crucial for the diagnosis of prostate cancer. Manual segmentation is time-consuming, requires advanced medical expertise, and is subject to inter-operator variability. Automatic lesion segmentation therefore represents a valuable tool to support clinicians by reducing workload, minimizing observer bias, and enabling more consistent image analysis. In this work, we investigated the performance of four deep learning architectures for prostate lesion segmentation: nnU-Net, DenseUNet, SegResUNet, and U-Net. Unlike many existing studies that rely on publicly available data, we constructed a dedicated dataset to better capture real-world variability and challenges. The dataset, comprising T2-weighted (T2W), apparent diffusion coefficient (ADC), and diffusion-weighted imaging (DWI) sequences, was carefully annotated by medical experts to ensure high-quality labels. Training was performed using the full combination of these modalities. Two cohorts were considered based on lesion severity, as defined by PI-RADS (Prostate Imaging–Reporting and Data System) scores: one with only PI-RADS 4–5 lesions (151 patients), and another including PI-RADS 3 cases, totaling 209 patients. Evaluation was conducted both on a patient-by-patient basis and in a consolidated all-patient setting. In the patient-level analysis, nnU-Net achieved the highest Dice similarity coefficient (DSC) of 0.60 when trained on PI-RADS 4–5 lesions, while in the all-patient analysis, DenseUNet attained a DSC of 0.57 on the same dataset. These results are within the range reported in recent prostate lesion segmentation studies, and in some cases are comparable to or exceed those obtained with substantially larger datasets.
- Open Access
- 9 December 2025
- Published by Royal Society of Chemistry (RSC) in RSC Mechanochemistry
- Vol. 3 (2) , 144-160
Flow-through mechanochemical synthesis by reactive extrusion
Transition metal-catalyse cross-couplings, nucleophilic substitutions, amidations, oxidations, reductions and condensation processes.
- 9 December 2025
- Published by Royal Society of Chemistry (RSC) in RSC Mechanochemistry
- Vol. 3 (2) , 144-160
Open AccessFlow-through mechanochemical synthesis by reactive extrusion
Transition metal-catalyse cross-couplings, nucleophilic substitutions, amidations, oxidations, reductions and condensation processes.
- 25 October 2025
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 55 (2) , 207-216
Detection of dental restorations and prosthesis devices in panoramic dental X-ray using fast region-based convolutional neural network
Objectives: This study aimed to develop and evaluate an artificial intelligence (AI) framework for detecting dental restorations and prosthesis devices on panoramic radiographs (PRs). Detecting these elements is essential for enhancing automated reporting, improving the accuracy of dental assessments, and reducing manual examination time. Methods: A fast region-based convolutional neural network (Fast R-CNN) was trained using 186 PRs for the training set and 42 for validation. The model’s performance was assessed on an external test dataset of 1133 PRs. Seven dental restorations and prosthesis devices were targeted: appliance, bridge, endodontic filling, crown filling, implant, retainer, and single crown. Precision, recall, and F1-score were calculated for each element to measure detection accuracy. Results: The AI framework achieved high performance across all categories, with precision, recall, and F1-scores as follows: appliance (0.79, 0.96, 0.87), bridge (0.91, 0.86, 0.89), endodontic filling (0.98, 0.98, 0.98), crown filling (0.95, 0.95, 0.95), implant (0.99, 0.97, 0.98), retainer (0.98, 0.98, 0.98), and single crown (0.94, 0.96, 0.95). The system processes one panoramic image in under 30 seconds. Conclusions: The AI framework demonstrated high recall and efficiency in detecting dental prosthesis and other dental restorations on PRs. Its application could significantly streamline dental diagnostics and automated reporting, enhancing both the speed and accuracy of dental assessments. Advances in knowledge: This study highlights the potential of AI in automating the detection of multiple dental restorations and prosthesis on PRs, offering a valuable tool for dental professionals to improve diagnostic workflows.
- 25 October 2025
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 55 (2) , 207-216
Detection of dental restorations and prosthesis devices in panoramic dental X-ray using fast region-based convolutional neural network
Objectives: This study aimed to develop and evaluate an artificial intelligence (AI) framework for detecting dental restorations and prosthesis devices on panoramic radiographs (PRs). Detecting these elements is essential for enhancing automated reporting, improving the accuracy of dental assessments, and reducing manual examination time. Methods: A fast region-based convolutional neural network (Fast R-CNN) was trained using 186 PRs for the training set and 42 for validation. The model’s performance was assessed on an external test dataset of 1133 PRs. Seven dental restorations and prosthesis devices were targeted: appliance, bridge, endodontic filling, crown filling, implant, retainer, and single crown. Precision, recall, and F1-score were calculated for each element to measure detection accuracy. Results: The AI framework achieved high performance across all categories, with precision, recall, and F1-scores as follows: appliance (0.79, 0.96, 0.87), bridge (0.91, 0.86, 0.89), endodontic filling (0.98, 0.98, 0.98), crown filling (0.95, 0.95, 0.95), implant (0.99, 0.97, 0.98), retainer (0.98, 0.98, 0.98), and single crown (0.94, 0.96, 0.95). The system processes one panoramic image in under 30 seconds. Conclusions: The AI framework demonstrated high recall and efficiency in detecting dental prosthesis and other dental restorations on PRs. Its application could significantly streamline dental diagnostics and automated reporting, enhancing both the speed and accuracy of dental assessments. Advances in knowledge: This study highlights the potential of AI in automating the detection of multiple dental restorations and prosthesis on PRs, offering a valuable tool for dental professionals to improve diagnostic workflows.
- 19 May 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (6) , e70062
Exploring the Limitations of Virtual Contrast Prediction in Brain Tumor Imaging: A Study of Generalization Across Tumor Types and Patient Populations
Accurate and timely diagnosis of brain tumors is critical for patient management and treatment planning. Magnetic resonance imaging (MRI) is a widely used modality for brain tumor detection and characterization, often aided by the administration of gadolinium‐based contrast agents (GBCAs) to improve tumor visualization. Recently, deep learning models have shown remarkable success in predicting contrast‐enhancement in medical images, thereby reducing the need of GBCAs and potentially minimizing patient discomfort and risks. In this paper, we present a study aimed at investigating the generalization capabilities of a neural network trained to predict full contrast in brain tumor images from noncontrast MRI scans. While initial results exhibited promising performance on a specific tumor type at a certain stage using a specific dataset, our attempts to extend this success to other tumor types and diverse patient populations yielded unexpected challenges and limitations. Through a rigorous analysis of the factor contributing to these negative results, we aim to shed light on the complexities associated with generalizing contrast enhancement prediction in medical brain tumor imaging, offering valuable insights for future research and clinical applications.
- 19 May 2025
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (6) , e70062
Exploring the Limitations of Virtual Contrast Prediction in Brain Tumor Imaging: A Study of Generalization Across Tumor Types and Patient Populations
Accurate and timely diagnosis of brain tumors is critical for patient management and treatment planning. Magnetic resonance imaging (MRI) is a widely used modality for brain tumor detection and characterization, often aided by the administration of gadolinium‐based contrast agents (GBCAs) to improve tumor visualization. Recently, deep learning models have shown remarkable success in predicting contrast‐enhancement in medical images, thereby reducing the need of GBCAs and potentially minimizing patient discomfort and risks. In this paper, we present a study aimed at investigating the generalization capabilities of a neural network trained to predict full contrast in brain tumor images from noncontrast MRI scans. While initial results exhibited promising performance on a specific tumor type at a certain stage using a specific dataset, our attempts to extend this success to other tumor types and diverse patient populations yielded unexpected challenges and limitations. Through a rigorous analysis of the factor contributing to these negative results, we aim to shed light on the complexities associated with generalizing contrast enhancement prediction in medical brain tumor imaging, offering valuable insights for future research and clinical applications.
- 8 May 2025
- Published by Clinical and Experimental Rheumatology in Clinical and Experimental Rheumatology
- Vol. 43 (5) , 822-828
Artificial intelligence software in biomedical imaging: a pharmaceutical perspective on radiology and contrast-enhanced ultrasound applications
Special Article; Authors: G. Valbusa, A. Fringuello Mingo, S. Colombo Serra
- 8 May 2025
- Published by Clinical and Experimental Rheumatology in Clinical and Experimental Rheumatology
- Vol. 43 (5) , 822-828
Artificial intelligence software in biomedical imaging: a pharmaceutical perspective on radiology and contrast-enhanced ultrasound applications
Special Article; Authors: G. Valbusa, A. Fringuello Mingo, S. Colombo Serra