Type
Company
Locations
Starnberg, Germany

Latest Publications

  • Open Access

    Nebulized hypertonic saline in infants with acute viral bronchiolitis: a systematic review and meta-analysis of 35 randomized clinical trials

    by Stephanie Thee, Susanne Sauerer, Andrew Bush, Rosina Ledermüller, Lefteris Teperikidis, Arshan Perera, Marcus A. Mall

    Background: Acute bronchiolitis is the leading cause of hospital admission in infants under 2 years. While management is primarily supportive, nebulized hypertonic saline (HS) has been proposed to improve mucociliary clearance, though clinical guidelines remain inconsistent. Objective: To evaluate the efficacy of nebulized HS compared with normal saline (NS) in infants with acute bronchiolitis. Methods: We conducted a systematic review and meta-analysis of randomized controlled trials (RCTs) in children aged ≤24 months with bronchiolitis. Eligible studies compared nebulized HS with NS and reported hospital admission, clinical symptom severity, or length of hospital stay (LOS). PubMed and the Cochrane Library were searched from inception to February 12, 2025. Risk of bias was assessed using the Cochrane RoB 2 tool. Random-effects meta-analyses were performed using relative risks (RRs), standardized mean differences (SMDs), and mean differences (MDs), with heterogeneity assessed using the I 2 statistic. Cumulative meta-analyses and sensitivity analyses were also conducted. Results: Thirty-five RCTs including 4723 infants were analyzed. Compared with NS, HS reduced hospital admission by 26% (RR 0.74, 95% CI 0.60–0.90), improved symptom severity at 24 h (SMD 0.48), 48 h (0.53), and 72 h (0.42), and shortened LOS (MD −0.44 days, 95% CI −0.68 to −0.21). Heterogeneity was substantial for symptom severity (I 2 =88.9% to 91.7%) and LOS (I 2 =80.3%) warranting cautious interpretation. Cumulative meta-analysis demonstrated early variability followed by stabilization of effect estimates over time. Conclusion: Nebulized HS provides consistent clinical benefit compared with NS in infants with bronchiolitis and supports reconsideration of its role in clinical practice.

  • Nocturnal digital cough monitoring in people with Primary Ciliary Dyskinesia and Cystic Fibrosis – First results of an international multi-centre observational study

    by S Thee, S Harnis, M Stahl, D Huscher, A M Dittrich, S Sutharsan, P R Burgel, D Downey, C Fuchs, M Mall

  • Open Access

    Effect of Nebulizer Breath-Guiding on Breathing Patterns and Lung Deposition

    by Benjamin Heine, Uwe Schuschnig, Jakob Richter, Andreas Liebl, Lea Botermann, Gesa Bräunlich, Nicolas Schwenck, Maximilian J. Grill, Michael Hahn

    Background: Efficient aerosol therapy depends on both device performance and inhalation technique. Breath-triggered vibrating mesh nebulizers reduce drug loss by generating aerosol only during inspiration but may prolong treatment. Guiding patients toward slow, deep breathing could improve lung deposition and shorten nebulization time, yet quantitative evidence, particularly across disease groups, remains limited. Objective: To assess how integrated breath-guiding features influence breathing behavior, lung deposition, and user perception in healthy adults and in patients with obstructive or restrictive lung disease. Methods: Sixty-four participants inhaled through three nebulizer configurations: a low-resistance reference (eFlow OS) and two versions of the eFlow Integrated featuring direction-dependent resistance and multimodal feedback, tested with or without a breath-guiding app. Flow signals from multiple breaths were analyzed to determine phase-averaged breathing parameters. Device effects were evaluated by ANOVA. Representative breathing patterns and unsteady aerosol characteristics were input to a validated whole-lung in silico model to estimate deposition. User experience was assessed by questionnaire. Results: Breath-guiding consistently altered inhalation behavior. Peak inspiratory flow decreased by ∼20%, the I/E ratio increased by >15%, and with the breath guide app, tidal volume (+40%) and breath duration (+47%) increased. These effects were similar across disease groups. In silico simulations showed improved delivery with guided inhalation: lung drug deposition rate increased by 3.7% and 15.5%, and alveolar deposited mass fraction rose by 66% and 76% versus the reference. The breath guide app further shifted deposition from extrathoracic to thoracic and alveolar regions and reduced exhalation losses (–14%). Most participants (88%) were satisfied or very satisfied, citing pleasant resistance and helpful app guidance. Conclusion: Breath-guiding features and digital coaching reliably promote slower, deeper breathing, leading to greater lung and alveolar deposition and shorter expected nebulization times. High user acceptance underscores the clinical potential of patient-centric, guided inhalation in optimizing aerosol therapy.

  • A60-18 Performance and Acceptance of a Pediatric Valved Holding Chamber Mask Under Clinically Realistic Application Conditions

    by L Cambridge, Y Burmeister, A Winzen

    Rationale: The efficacy of valved holding chambers (VHC) with masks critically depends on achieving an effective mask-to-face seal, which is influenced by mask design and the applied force. Insufficient pressure can increase leakage and reduce inhaled doses, potentially compromising therapeutic effectiveness. While regulatory standards specify an application pressure of 16N for in-vitro testing, real-world use typically involves ∼4N, which is more comfortable and better tolerated by children. This study evaluated leakage and aerosol performance under clinically realistic pressures alongside a caregiver questionnaire assessing mask comfort, usability, and acceptance of the new design. Methods: Two pediatric face models from the Liam (Louis Infant Anatomical Model) family, Liam Baby (9 months) and Liam Infant (2-3 years) were used to evaluate three commercially available VHC face masks with their respective chambers. Models replicate pediatric facial geometry and soft-tissue compliance based on 3D scans of real children. Mask-face leakage and aerosol delivery of budesonide were measured at 4N contact force using a validated test setup. An electronic questionnaire was administered to caregivers of pediatric patients prescribed a VHC to assess mask usability, seal perception, comfort, and acceptance. Results: Among baby-sized masks, Vortex’s minimal leakage (2.2%±0.17, mean±SD) from better seal integrity corresponded to the highest respirable dose of budesonide (34.36 ± 5.4), while OptiChamber Diamond and AeroChamber masks exhibited higher leakage (17.4%±4.1,35.9%±1.8) and lower respirable doses respectively (11.30 ± 1.5, 0.01 ± 0.01). For child-sized masks, Vortex showed the lowest leakage (1.3%±0.5) and consistent drug delivery (31.66 ± 3.5). Despite moderate leakage, OptiChamber and AeroChamber (8.4%±4.8,10.6%±1.7) delivered adequate doses of budesonide (27.45 ± 5.2, 22.97 ± 4.7). Preliminary analysis of the caregiver questionnaire (n = 30) indicates high satisfaction with the mask. Most reported it was comfortable, sealed effectively with minimal pressure, with 96% reporting overall acceptance by their child. Conclusions: Facemask leakage can substantially reduce the effectiveness of drug delivery in pediatric patients using VHCs. Testing under clinically realistic 4N application forces showed that mask performance can differ markedly. The Vortex pediatric masks achieved effective sealing and drug delivery under representative use conditions. Preliminary caregiver feedback indicates 96% acceptance with favorable usability, underscoring the importance of evaluating both technical performance and real-world comfort in pediatric aerosol delivery systems. This abstract is funded by: PARI GmbH

  • Open Access

    Understanding Nebulizer Utilization by Patients and Healthcare Providers: A COPD Foundation Nebulizer Consortium Survey Study

    by Kathryn Melamed, Sergio Martinez, Lisa Cambridge, David Christiani, Jie Li, Jill Ohar, Rajiv Dhand, M Drummond, Arzu Ari, Lewis Radonovich Jr, et al.

    Rationale: Inhaled medications are the mainstay of chronic obstructive pulmonary disease (COPD) management. While consensus guidelines for pharmacological management in COPD are well-established, few guidelines exist regarding inhaled medication delivery systems. The COPD Foundation Nebulizer Consortium conducted a cross-sectional survey of patients with COPD and healthcare providers to understand their perceptions and utilization of nebulized medications. Methods: An online survey was conducted from February 7 through April 9, 2024. Patients completed a 42-question survey, including demographic information, tobacco use, symptoms severity, and the role of nebulizers in their treatment. Healthcare providers responded to a 17-question survey about their clinical experience with nebulized medications. Results: We analyzed responses from 347 patients and 39 healthcare providers. Among patients, 76.4% (265/347) were ≥ 65 years old, 72.0% (250/347) were female, 93.4% (324/347) were white, 90.5% (314/347) had a current or former smoking history, 77.6% (263/339) reported at least one exacerbation in the past year, and 70.8% (240/339) used some form of supplemental oxygen. Nebulizer use was reported by 84.1% (292/347) of patients. Among nebulizer users, 94.5% (276/292) used short-acting while only 22.3% (65/292) used long-acting nebulized medications. Patients reported that hand-held inhaler devices were easier to use (69.8%, 171/245), but nebulized therapy led to better symptom control (64.9%, 159/245) and had lower copays (67.8%, 166/245). Among prescribers surveyed, most (82.1%, 32/39) believed nebulizers were preferable for patients experiencing exacerbations. Impediments to wider use of nebulizers included difficulties with insurance coverage (69.2%, 27/39), cost (53.8%, 21/39), and lack of combination nebulized drugs (46.2%, 18/39). Two-thirds of providers thought that nebulizers were underused. Conclusion: We demonstrate that while patients and providers both perceive nebulizers as preferred in clinical management of COPD, there is discordance between patient and provider perception of nebulizer use on the basis of cost and feasibility of use.


  • Open Access

    Pediatric Valved Holding Chamber Facemask Leakage at Clinically Relevant Application Forces

    by Yvonne Burmeister, Andrea Winzen

    Effective aerosol therapy in pediatric populations, particularly among children under 4 years of age, reveals unique clinical challenges. The use of pressurized metered-dose inhalers combined with valved holding chambers (VHCs) and facemasks is a widely endorsed method for delivering inhaled medications in this population, as recommended by national and international respiratory guidelines (Nationale VersorgungsLeitlinie Asthma V5.0, Global Strategy for Asthma Management and Prevention 2025). However, the efficacy of this system critically depends on the integrity of the facemask seal, which is influenced by mask design and the applied force during administration (Häselbarth J et al., Acta Paediatr. 2020; 109(3): 565–572). A poor seal resulting from mask-to-face leakage or an ill-fitting mask can substantially reduce pulmonary aerosol deposition and cause discomfort, further compromising therapeutic effectiveness (Nikander K et al. J Aerosol Med Pulm Drug Deliv. 2014; 27 Suppl1: S4–S23). While regulatory standards for in vitro performance testing prescribe a relatively high, fixed application force of 16 N (equivalent to a weight of 1.6 kg) to ensure a tight facemask seal (US PharmacopeiaSpacers and Valved Holding Chambers Used with Inhalation Aerosols—Characterization Tests), such conditions do not reflect clinical reality. In real-world settings, caregivers generally apply significantly lower forces when holding the mask to a child’s face. Data indicate that children aged 1–4 years typically tolerate application forces closer to 4 N, which corresponds to a weight of approximately 408 g (Minh KT et al., J Aerosol Med Pulm Drug Deliv. 2014; 27 Suppl 1:S55–S62). This discrepancy raises concerns regarding the clinical significance of laboratory-based performance assessments for pediatric inhalation masks and underscores the potential for facemask leakage under practical conditions. To address these issues, the present study aimed to compare the leakage performance of six commercially available pediatric VHC facemask systems designed for use in infants and young children. Seal integrity was evaluated across a broad range of applied forces, including both clinically relevant and regulatory-recommended levels. By aligning testing conditions more closely with real-world clinical scenarios, this study seeks to generate data that more accurately inform clinical practice as well as future pediatric face mask design. Received: 02 August 2025 Accepted after revision: 05 November 2025 Article published online: 12 December 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany


  • Open Access

    Inhalative polyclonal immunoglobulin G for the prevention of respiratory infections: A comprehensive in vitro assessment

    by Rebecca Rittersberger, Caroline Covini, Shruthi Kalgudde, Pramod Kumar, Franziska Voß, Janik Martin, Franziska Magdalena Deuter, Gabriel Koslowski, Annabelle Dabbars, Sophia Salcher, et al.


  • Open Access

    Symptom control and medication adherence in Japanese pediatric and adolescent asthma: A large-scale web-based cross-sectional survey

    by Shigemi Yoshihara, Toshiko Itazawa, Taiji Nakano, Daisuke Hayashi, Takumi Takizawa, Arshan Perera, Yoshiyuki Yamada

  • Understanding Nebulizer Utilization in Clinical Practice: A COPD Foundation Nebulizer Consortium Survey Study

    by K. Melamed, L. Cambridge, D.C. Christiani, J. Li, J.A. Ohar, R. Dhand, M.B. Drummond, A. Ari, L.J. Radonovich, D.P. Tashkin, et al.

    RATIONALE: Inhaled medications are the mainstay of chronic obstructive pulmonary disease (COPD) management. While consensus guidelines for pharmacological management in COPD are well-established, few guidelines exist regarding inhaled medication delivery systems. The COPD Foundation Nebulizer Consortium conducted a cross-sectional survey of patients with COPD and healthcare providers to better understand their perception of nebulizers and assess nebulizer utilization in clinical practice. METHODS: An online survey was conducted from February 7 through April 9, 2024 among patients and healthcare providers from the COPD Foundation's online patient platform, newsletters, and social media channels. Patients completed a 42-question survey, including demographic information, smoking history, lung disease history, symptom and exacerbation history, and the role of nebulizers in their treatment. Providers responded to 17 questions about their treatment experience with nebulizers, nebulized medications, and other delivery devices. RESULTS: We analyzed 578 responses (462 from patients and 116 from healthcare providers). Of the patient respondents, 95% (433/454) reported a diagnosis of COPD, 75% (344/454) were ≥65 years old, 72% (263/364) female, 93% (341/364) white, and 91% (331/364) had current or former smoking history. Regarding disease activity, 78% (277/356) reported at least one exacerbation in the past year and 70% (250/356) used some form of supplemental oxygen. Nebulizer use was reported by 40% (143/356) on a scheduled basis, 45% (161/356) as needed, and 15% (52/356) reported not using a nebulizer at all. Most patients used short-acting therapy and 23% (61/264) used long-acting nebulized medications. While respondents reported that hand-held inhaler devices were easier to use (70%, 178/254), patients reported that nebulized therapy in comparison had lower copay (68%, 172/254) and better COPD symptom control (65%, 165/254). Of the providers surveyed, 79% (33/42) were pulmonologists and about half (51%, 58/113) prescribe nebulizers. Common reported barriers to prescribing nebulizers were insurance coverage (64%, 27/42), cost (48%, 20/42), and lack of availability of combination drugs for nebulization (43%, 18/42), and two-thirds of providers (28/42) thought that nebulizers were underused. Most prescribers (81%, 34/42) believed nebulizers are preferable for patients experiencing exacerbations. CONCLUSION: Nebulized medications are widely used for COPD, and both patients and providers believe that nebulizers offer superior symptom control compared to hand-held inhaler devices. Simultaneously, most providers believed nebulizers are underutilized, nearly half did not prescribe them, and when prescribed, it was rarely for administration of long-acting medication. There is discordance between patient and provider perception of nebulizer efficacy and nebulizer use in clinical management of COPD.