Clinique Jules Verne
Type
HealthcareLocations
Nantes, FranceLatest Publications
- Open Access
- 24 November 2026
- Published by Springer Nature in International Journal of Retina and Vitreous
Early switch versus late switch from anti-VEGF to dexamethasone implant for macular edema secondary to retinal vein occlusion: a retrospective cohort study
Background: The optimal timing of switching from anti-vascular endothelial growth factor (anti-VEGF) therapy to dexamethasone intravitreal implant (DEX-i) in retinal vein occlusion (RVO)-related macular edema remains uncertain. We compared observed outcomes after earlier and later switching. Methods: This single-center retrospective cohort comprised eyes with branch or central RVO treated between 2017 and 2026. Switching within six months of the first anti-VEGF injection defined the Early Switch group; switching after six months defined the Late Switch group. Eyes receiving DEX-i without previous anti-VEGF were included for descriptive context only. Longitudinal best-corrected visual acuity (BCVA), central retinal thickness (CRT), and cumulative injections were analyzed using exploratory mixed-effects models adjusted for RVO subtype and baseline ischemic status. Results: Of 755 patients screened, 65 were included (Early Switch, n = 14; Late Switch, n = 31; DEX-solo, n = 20). Before switching, the median number of anti-VEGF injections was 4 versus 11, respectively. BCVA trajectories did not differ significantly (group-by-time interaction, p = 0.399), whereas modeled CRT reduction was greater in the Early Switch group (between-group slope difference, 18.27 µm/year; 95% CI 1.97–34.57; p = 0.028). Over the first 12 months after DEX-i, injection counts were 1.92 ± 1.00 and 2.74 ± 1.33, respectively ( p = 0.0696). Conclusions: In this selected cohort, earlier switching was associated with a greater modeled decrease in CRT but no statistically detectable difference in BCVA trajectory. These exploratory associations do not establish clinical or causal superiority.
- 24 November 2026
- Published by Springer Nature in International Journal of Retina and Vitreous
Open AccessEarly switch versus late switch from anti-VEGF to dexamethasone implant for macular edema secondary to retinal vein occlusion: a retrospective cohort study
Background: The optimal timing of switching from anti-vascular endothelial growth factor (anti-VEGF) therapy to dexamethasone intravitreal implant (DEX-i) in retinal vein occlusion (RVO)-related macular edema remains uncertain. We compared observed outcomes after earlier and later switching. Methods: This single-center retrospective cohort comprised eyes with branch or central RVO treated between 2017 and 2026. Switching within six months of the first anti-VEGF injection defined the Early Switch group; switching after six months defined the Late Switch group. Eyes receiving DEX-i without previous anti-VEGF were included for descriptive context only. Longitudinal best-corrected visual acuity (BCVA), central retinal thickness (CRT), and cumulative injections were analyzed using exploratory mixed-effects models adjusted for RVO subtype and baseline ischemic status. Results: Of 755 patients screened, 65 were included (Early Switch, n = 14; Late Switch, n = 31; DEX-solo, n = 20). Before switching, the median number of anti-VEGF injections was 4 versus 11, respectively. BCVA trajectories did not differ significantly (group-by-time interaction, p = 0.399), whereas modeled CRT reduction was greater in the Early Switch group (between-group slope difference, 18.27 µm/year; 95% CI 1.97–34.57; p = 0.028). Over the first 12 months after DEX-i, injection counts were 1.92 ± 1.00 and 2.74 ± 1.33, respectively ( p = 0.0696). Conclusions: In this selected cohort, earlier switching was associated with a greater modeled decrease in CRT but no statistically detectable difference in BCVA trajectory. These exploratory associations do not establish clinical or causal superiority.
- Open Access
- 7 October 2026
- Published by Springer Nature in Antimicrobial Resistance & Infection Control
Assessment of infection prevention practices in office-based surgery: a multicentre regional audit
Background: Office-based surgery (OBS) is increasingly used due to organizational constraints and perceived benefits. However, data on infection prevention and control (IPC) practices in OBS settings remain limited. This study aimed to assess the conditions in which OBS are performed, focusing on IPC measures. Methods: A regional audit was conducted between July 2023 and January 2024. Healthcare facilities with at least one room dedicated to OBS were eligible. Four domains were assessed: architecture and organization, cleaning procedures, patient pathways, and professional practices. Data were collected during on-site visits by IPC professionals using standardized checklists based on direct observation and interviews. Individual and composite criteria were analysed. Results: Forty OBS rooms from 15 centres (two university hospitals, eight public hospitals, and five private clinics) were included. A total of 173 procedures from 17 specialties were identified, mainly ophthalmology (33%), Ear, Nose and Throat (27%), dermatology (20%), and urology (15%). Mechanical ventilation was used in 80% of rooms and operating room-like ventilation (ISO Class 8 or 7 cleanroom) in 20%. Protocols for surgical hand disinfection by the surgeon before each procedure was present in 33% of teams. IPC training was reported by 67% of teams; 56% were trained in skin preparation and 40% in circulator roles. Skin preparation was explained to patients in 72% of pathways and documented in 44%. Public facilities scored significantly higher than private facilities for ventilation, room equipment, and patient pathway criteria (all p < 0.01). Conclusion: OBS includes diverse procedures across varied settings and is performed by teams with heterogeneous awareness regarding IPC measures. Strengthening IPC training, standardization, and documentation could improve patient safety.
- 7 October 2026
- Published by Springer Nature in Antimicrobial Resistance & Infection Control
Open AccessAssessment of infection prevention practices in office-based surgery: a multicentre regional audit
Background: Office-based surgery (OBS) is increasingly used due to organizational constraints and perceived benefits. However, data on infection prevention and control (IPC) practices in OBS settings remain limited. This study aimed to assess the conditions in which OBS are performed, focusing on IPC measures. Methods: A regional audit was conducted between July 2023 and January 2024. Healthcare facilities with at least one room dedicated to OBS were eligible. Four domains were assessed: architecture and organization, cleaning procedures, patient pathways, and professional practices. Data were collected during on-site visits by IPC professionals using standardized checklists based on direct observation and interviews. Individual and composite criteria were analysed. Results: Forty OBS rooms from 15 centres (two university hospitals, eight public hospitals, and five private clinics) were included. A total of 173 procedures from 17 specialties were identified, mainly ophthalmology (33%), Ear, Nose and Throat (27%), dermatology (20%), and urology (15%). Mechanical ventilation was used in 80% of rooms and operating room-like ventilation (ISO Class 8 or 7 cleanroom) in 20%. Protocols for surgical hand disinfection by the surgeon before each procedure was present in 33% of teams. IPC training was reported by 67% of teams; 56% were trained in skin preparation and 40% in circulator roles. Skin preparation was explained to patients in 72% of pathways and documented in 44%. Public facilities scored significantly higher than private facilities for ventilation, room equipment, and patient pathway criteria (all p < 0.01). Conclusion: OBS includes diverse procedures across varied settings and is performed by teams with heterogeneous awareness regarding IPC measures. Strengthening IPC training, standardization, and documentation could improve patient safety.
- Open Access
- 6 August 2026
- Published by Georg Thieme Verlag KG in Endoscopy International Open
Impact of teleconsultation before endoscopic submucosal dissection on quality of care and environmental sustainability: a French multicenter study
Introduction: The European Society of Gastrointestinal Endoscopy has highlighted the environmental impact of endoscopic practice and the need to reduce it. One of the major contributors is patient transportation, despite the availability of remote alternatives for pre-procedural consultations. The aim of this study was to compare face-to-face (FF) and virtual remote (VR) consultations prior to colorectal endoscopic submucosal dissection (ESD) in terms of effectiveness, safety, and carbon footprint. Methods: We used a prospective national database including consecutive colorectal ESD cases performed in France between July 2023 and September 2024. Pre-procedural consultations were conducted either FF or via VR consultation, according to patient preference and logistical feasibility. Procedure-related travel included diagnostic colonoscopy and/or local consultation, anesthesiology consultation (local or remote, excluding same-day combined visits), gastroenterology consultation at the referral center, and travel for the ESD procedure itself. Environmental impact was estimated based on the distance between the patient’s residence and the endoscopy unit, the mode of transportation, and validated conversion coefficients. Results: Between July 2023 and September 2024, 1,729 patients undergoing colorectal ESD were included; 1,451 (84%) underwent face-to-face (FF) and 278 (16%) virtual remote (VR) pre-procedural consultations. Baseline characteristics were comparable. En bloc, R0, and curative resection rates were similar between FF and VR groups (97% vs 95%, p=0.31; 92% vs 88%, p=0.13; 90% vs 90%, p=0.86), as were bleeding and perforation rates. The median cumulative travel distance was significantly lower in the VR group (180.0 km [IQR 261.0] vs 394.6 km [IQR 447.6], p<0.001). Median cumulative carbon footprint decreased from 89.4 to 31.9 CO₂-eq units (p<0.001), corresponding to a total saving of 51,106 CO₂-eq units. Conclusion: Colorectal ESD performed after VR consultation shows comparable effectiveness and safety to FF consultation, while significantly reducing the carbon footprint.
- 6 August 2026
- Published by Georg Thieme Verlag KG in Endoscopy International Open
Open AccessImpact of teleconsultation before endoscopic submucosal dissection on quality of care and environmental sustainability: a French multicenter study
Introduction: The European Society of Gastrointestinal Endoscopy has highlighted the environmental impact of endoscopic practice and the need to reduce it. One of the major contributors is patient transportation, despite the availability of remote alternatives for pre-procedural consultations. The aim of this study was to compare face-to-face (FF) and virtual remote (VR) consultations prior to colorectal endoscopic submucosal dissection (ESD) in terms of effectiveness, safety, and carbon footprint. Methods: We used a prospective national database including consecutive colorectal ESD cases performed in France between July 2023 and September 2024. Pre-procedural consultations were conducted either FF or via VR consultation, according to patient preference and logistical feasibility. Procedure-related travel included diagnostic colonoscopy and/or local consultation, anesthesiology consultation (local or remote, excluding same-day combined visits), gastroenterology consultation at the referral center, and travel for the ESD procedure itself. Environmental impact was estimated based on the distance between the patient’s residence and the endoscopy unit, the mode of transportation, and validated conversion coefficients. Results: Between July 2023 and September 2024, 1,729 patients undergoing colorectal ESD were included; 1,451 (84%) underwent face-to-face (FF) and 278 (16%) virtual remote (VR) pre-procedural consultations. Baseline characteristics were comparable. En bloc, R0, and curative resection rates were similar between FF and VR groups (97% vs 95%, p=0.31; 92% vs 88%, p=0.13; 90% vs 90%, p=0.86), as were bleeding and perforation rates. The median cumulative travel distance was significantly lower in the VR group (180.0 km [IQR 261.0] vs 394.6 km [IQR 447.6], p<0.001). Median cumulative carbon footprint decreased from 89.4 to 31.9 CO₂-eq units (p<0.001), corresponding to a total saving of 51,106 CO₂-eq units. Conclusion: Colorectal ESD performed after VR consultation shows comparable effectiveness and safety to FF consultation, while significantly reducing the carbon footprint.
- Open Access
- 1 August 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-11
Clinical Performance of an Isofocal Toric Intraocular Lens with Double C-Loop Haptics: A Multicenter Retrospective Study
Purpose: To evaluate clinical outcomes in eyes with pre-existing astigmatism undergoing cataract surgery or refractive lens exchange with the implantation of an isofocal optic-design toric intraocular lens (IOL) with double C-loop haptics. Method: This multicenter retrospective study comprised 100 eyes (65 patients) implanted with the Isopure Serenity toric IOL (BVI, Inc.) conducted across four sites. Postoperative evaluation at between 2 and 3 months included manifest refraction, monocular uncorrected and distance corrected visual acuity (UDVA and CDVA), monocular uncorrected and distance corrected intermediate visual acuity (UIVA and DCIVA, at 80 and 66 cm), monocular uncorrected and distance corrected near visual acuity (UNVA and DCNVA, at 40 cm), binocular defocus curve and rotational stability. Results: Manifest refraction spherical equivalent and refractive astigmatism were − 0.24± 0.41D and − 0.36± 0.36D, respectively. About 79% and 97% of eyes were within ± 0.50D and ± 1.00D, respectively, and 80% and 96% of eyes were ≤ 0.50D and ≤ 1.00D of refractive cylinder, respectively. At distance vision, the mean monocular CDVA was − 0.02± 0.06 logMAR and 92.93% of eyes showed a CDVA of ≥ 20/20. At intermediate vision, the mean monocular DCIVA values were 0.10± 0.07 and 0.17± 0.10 logMAR at 80 cm and 66 cm, respectively; and 96.92% and 88.33% of eyes showed a DCIVA of ≥ 20/32 at 80 cm and 66 cm, respectively. At near vision, the mean monocular DCNVA was 0.31± 0.08 logMAR and 75.44% of eyes showed a DCNVA of ≥ 20/40. The binocular depth of focus range was approximately 1.50D. The mean absolute IOL rotation was 2.73± 2.58 degrees with all eyes having a rotation of < 10 degrees. Conclusions: Eyes with pre-existing astigmatism implanted with the Isopure Serenity toric IOL showed good distance visual acuity and functional intermediate vision, with high refractive accuracy and good rotational stability following cataract and refractive lens exchange surgery.
- 1 August 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-11
Open AccessClinical Performance of an Isofocal Toric Intraocular Lens with Double C-Loop Haptics: A Multicenter Retrospective Study
Purpose: To evaluate clinical outcomes in eyes with pre-existing astigmatism undergoing cataract surgery or refractive lens exchange with the implantation of an isofocal optic-design toric intraocular lens (IOL) with double C-loop haptics. Method: This multicenter retrospective study comprised 100 eyes (65 patients) implanted with the Isopure Serenity toric IOL (BVI, Inc.) conducted across four sites. Postoperative evaluation at between 2 and 3 months included manifest refraction, monocular uncorrected and distance corrected visual acuity (UDVA and CDVA), monocular uncorrected and distance corrected intermediate visual acuity (UIVA and DCIVA, at 80 and 66 cm), monocular uncorrected and distance corrected near visual acuity (UNVA and DCNVA, at 40 cm), binocular defocus curve and rotational stability. Results: Manifest refraction spherical equivalent and refractive astigmatism were − 0.24± 0.41D and − 0.36± 0.36D, respectively. About 79% and 97% of eyes were within ± 0.50D and ± 1.00D, respectively, and 80% and 96% of eyes were ≤ 0.50D and ≤ 1.00D of refractive cylinder, respectively. At distance vision, the mean monocular CDVA was − 0.02± 0.06 logMAR and 92.93% of eyes showed a CDVA of ≥ 20/20. At intermediate vision, the mean monocular DCIVA values were 0.10± 0.07 and 0.17± 0.10 logMAR at 80 cm and 66 cm, respectively; and 96.92% and 88.33% of eyes showed a DCIVA of ≥ 20/32 at 80 cm and 66 cm, respectively. At near vision, the mean monocular DCNVA was 0.31± 0.08 logMAR and 75.44% of eyes showed a DCNVA of ≥ 20/40. The binocular depth of focus range was approximately 1.50D. The mean absolute IOL rotation was 2.73± 2.58 degrees with all eyes having a rotation of < 10 degrees. Conclusions: Eyes with pre-existing astigmatism implanted with the Isopure Serenity toric IOL showed good distance visual acuity and functional intermediate vision, with high refractive accuracy and good rotational stability following cataract and refractive lens exchange surgery.
- 5 June 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 03) , S358
Artificial Intelligence versus conventional scoring for assessing small bowel capsule endoscopy cleanliness in Crohn’s disease
Aims Evaluation of cleanliness in capsule endoscopy is essential to validate the exam. However, yet reliable evaluation of bowel cleanliness remains challenging. The validated KODA score provides robust assessment but is time-consuming and impractical in routine practice. We aimed to evaluate the performance of an AI-based tool (AXAROlite, Augmented Endoscopy) compared with the KODA score for assessing small bowel cleanliness in Crohn's disease (CD) patients. Methods This was a post-hoc analysis of a multicenter randomized controlled trial (NCT05117996) including 142 CD patients undergoing small bowel capsule endoscopy (SBCE) after either a standard PEG-based or simplified clear liquid preparation. All videos were evaluated for cleanliness using the KODA score by trained readers. The same videos were analyzed using the AI-based AXAROlite tool. Correlation, agreement, and diagnostic performance of AXAROlite were compared with the KODA score. Clinical factors influencing AI-assessed cleanliness were also investigated. Results Correlation between the KODA score and the AI-AXAROlite score was found strong for the whole SB (ρ=0.61; r2=0.35; p<0.001) and moderate to strong for each of the four quartiles analyzed: ρ=0.52; r2=0.24; p<0.001, ρ=0.56; r2=0.24; p<0.001, ρ=0.50; r2=0.21; p<0.001, ρ=0.62; r2=0.41; p<0.001 for the first, the second, the third and the fourth quartiles, respectively.When compared to the qualitative evaluation of the SB cleanliness i.e. good, fair or poor, both the KODA and the AXAROlite scores decreased similarly. The median [IQR] values of AXAROlite scores were respectively 75.0 [59.0-84.0], 56.0 [42.0-67.0] and 41.00 [25.75-59.75]. The differences were statistically significant between a good and a fair or poor cleanliness (p2.25 (AUROC=0.85, 95% CI 0.79–0.92), with an optimal threshold of 72% clean frames (sensitivity 86%, specificity 72%).In multivariate analysis, the activity of the disease and the SB transit time influenced negatively the AXAROlite score: β=-7.87 [-15.29; -0.44], p=0.0382 and β=-0.04 [-0.06; -0.01], p=0.0031 respectively. The behavior, the location of the disease, the endoscopic severity and the presence of an anastomosis, did not modify independently the AXAROlite SBscore. Conclusions AXAROlite provides a rapid, fully automated, and accurate evaluation of small bowel cleanliness in CD, comparable to the validated KODA score. Its integration into routine workflows may streamline reporting and reduce inter-observer variability. Article published online: 05 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 5 June 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 03) , S358
Artificial Intelligence versus conventional scoring for assessing small bowel capsule endoscopy cleanliness in Crohn’s disease
Aims Evaluation of cleanliness in capsule endoscopy is essential to validate the exam. However, yet reliable evaluation of bowel cleanliness remains challenging. The validated KODA score provides robust assessment but is time-consuming and impractical in routine practice. We aimed to evaluate the performance of an AI-based tool (AXAROlite, Augmented Endoscopy) compared with the KODA score for assessing small bowel cleanliness in Crohn's disease (CD) patients. Methods This was a post-hoc analysis of a multicenter randomized controlled trial (NCT05117996) including 142 CD patients undergoing small bowel capsule endoscopy (SBCE) after either a standard PEG-based or simplified clear liquid preparation. All videos were evaluated for cleanliness using the KODA score by trained readers. The same videos were analyzed using the AI-based AXAROlite tool. Correlation, agreement, and diagnostic performance of AXAROlite were compared with the KODA score. Clinical factors influencing AI-assessed cleanliness were also investigated. Results Correlation between the KODA score and the AI-AXAROlite score was found strong for the whole SB (ρ=0.61; r2=0.35; p<0.001) and moderate to strong for each of the four quartiles analyzed: ρ=0.52; r2=0.24; p<0.001, ρ=0.56; r2=0.24; p<0.001, ρ=0.50; r2=0.21; p<0.001, ρ=0.62; r2=0.41; p<0.001 for the first, the second, the third and the fourth quartiles, respectively.When compared to the qualitative evaluation of the SB cleanliness i.e. good, fair or poor, both the KODA and the AXAROlite scores decreased similarly. The median [IQR] values of AXAROlite scores were respectively 75.0 [59.0-84.0], 56.0 [42.0-67.0] and 41.00 [25.75-59.75]. The differences were statistically significant between a good and a fair or poor cleanliness (p2.25 (AUROC=0.85, 95% CI 0.79–0.92), with an optimal threshold of 72% clean frames (sensitivity 86%, specificity 72%).In multivariate analysis, the activity of the disease and the SB transit time influenced negatively the AXAROlite score: β=-7.87 [-15.29; -0.44], p=0.0382 and β=-0.04 [-0.06; -0.01], p=0.0031 respectively. The behavior, the location of the disease, the endoscopic severity and the presence of an anastomosis, did not modify independently the AXAROlite SBscore. Conclusions AXAROlite provides a rapid, fully automated, and accurate evaluation of small bowel cleanliness in CD, comparable to the validated KODA score. Its integration into routine workflows may streamline reporting and reduce inter-observer variability. Article published online: 05 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 5 June 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 03) , S84-S85
Impact of Gravity on the Outcomes of Colo-Rectal Endoscopic Submucosal Dissection in the Era of Traction Strategies: Results from a Large Prospective Multicenter Cohort
Aims Endoscopic submucosal dissection (ESD) with traction is increasingly used to facilitate En Bloc resection of large superficial colorectal tumors, but the impact of gravity on procedural outcomes in this context remains unclear. This study aimed to assess the influence of gravity orientation on traction-assisted colorectal ESD performance and safety [1] [2] [3] [4]. Methods Within a large international, multicenter, prospective cohort (22 centers), we included all patients who underwent traction-assisted colorectal ESD between July 2023 and May 2025. Lesions were classified by gravity (favorable, intermediate, unfavorable) based on luminal fluid distribution. The primary endpoint was dissection speed; secondary endpoints included R0 and En Bloc resection, perforation, bleeding, and intra-procedural position changes. Multivariable regression models were adjusted for lesion size, fibrosis, location, and operator expertise ([Table 1]). Results Among 3,738 procedures, 1,555 met inclusion criteria. Groups were comparable in lesion and operator characteristics. Mean dissection speed was 36.4 mm²/min with unfavorable gravity versus 38.6 mm²/min with favorable/intermediate gravity. Adjusted analysis confirmed non-inferiority of dissection speed in the unfavorable group (β=–0.10; 95% CI –0.15 to –0.06; p=0.007), with similar R0 (91.1% vs 91.1%) and En Bloc (97.9% vs 98.7%) resection rates. Perforation (8.0% vs 6.5%) and delayed bleeding (5.2% vs 5.7%) rates were comparable. Position changes were more frequent with unfavorable gravity (OR=3.85; p<0.001). Subgroup analysis based on the use of the underwater strategy revealed an interesting pattern: when the underwater approach was applied, resection speed tended to be higher in the unfavorable-gravity group. In contrast, in the absence of the underwater technique, there was a trend toward a slightly slower resection speed in the favorable/intermediate-gravity group. Conclusions In conclusion, when ESD is performed with traction assistance, the lesion’s position relative to gravity does not significantly affect procedural efficacy or complication rates. These findings suggest that routine consideration of gravity orientation may be less critical in such settings, potentially contributing to procedural simplification. Moreover, to our knowledge, this is the first study to evaluate the influence of gravity on the performance of combined traction and underwater strategies. Our results support prioritizing this combined approach for lesions located in unfavorable-gravity positions. Article published online: 05 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 5 June 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 03) , S84-S85
Impact of Gravity on the Outcomes of Colo-Rectal Endoscopic Submucosal Dissection in the Era of Traction Strategies: Results from a Large Prospective Multicenter Cohort
Aims Endoscopic submucosal dissection (ESD) with traction is increasingly used to facilitate En Bloc resection of large superficial colorectal tumors, but the impact of gravity on procedural outcomes in this context remains unclear. This study aimed to assess the influence of gravity orientation on traction-assisted colorectal ESD performance and safety [1] [2] [3] [4]. Methods Within a large international, multicenter, prospective cohort (22 centers), we included all patients who underwent traction-assisted colorectal ESD between July 2023 and May 2025. Lesions were classified by gravity (favorable, intermediate, unfavorable) based on luminal fluid distribution. The primary endpoint was dissection speed; secondary endpoints included R0 and En Bloc resection, perforation, bleeding, and intra-procedural position changes. Multivariable regression models were adjusted for lesion size, fibrosis, location, and operator expertise ([Table 1]). Results Among 3,738 procedures, 1,555 met inclusion criteria. Groups were comparable in lesion and operator characteristics. Mean dissection speed was 36.4 mm²/min with unfavorable gravity versus 38.6 mm²/min with favorable/intermediate gravity. Adjusted analysis confirmed non-inferiority of dissection speed in the unfavorable group (β=–0.10; 95% CI –0.15 to –0.06; p=0.007), with similar R0 (91.1% vs 91.1%) and En Bloc (97.9% vs 98.7%) resection rates. Perforation (8.0% vs 6.5%) and delayed bleeding (5.2% vs 5.7%) rates were comparable. Position changes were more frequent with unfavorable gravity (OR=3.85; p<0.001). Subgroup analysis based on the use of the underwater strategy revealed an interesting pattern: when the underwater approach was applied, resection speed tended to be higher in the unfavorable-gravity group. In contrast, in the absence of the underwater technique, there was a trend toward a slightly slower resection speed in the favorable/intermediate-gravity group. Conclusions In conclusion, when ESD is performed with traction assistance, the lesion’s position relative to gravity does not significantly affect procedural efficacy or complication rates. These findings suggest that routine consideration of gravity orientation may be less critical in such settings, potentially contributing to procedural simplification. Moreover, to our knowledge, this is the first study to evaluate the influence of gravity on the performance of combined traction and underwater strategies. Our results support prioritizing this combined approach for lesions located in unfavorable-gravity positions. Article published online: 05 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 5 June 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 03) , S48
Clinical impact and environmental footprint of diagnostic endoscopic dissection versus first line surgery for colorectal lesions harboring focal deep invasive pattern
Aims Endoscopic submucosal dissection (ESD) can achieve curative resection for T1 colorectal cancers fulfilling low-risk histological criteria. However, optical diagnosis does not always accurately predict submucosal invasion depth, and lesions with focal deep invasive patterns (FDIP) are often referred directly to surgery. A first-line diagnostic ESD strategy, performing en bloc resection in these lesions to obtain definitive histopathology before deciding on surgery, may represent a safe and cost-effective alternative. This study compared the clinical, environmental, and economic impact of diagnostic ESD versus upfront surgery for FDIP lesions [1] [2] [3] [4] [5] [6]. Methods This prospective multicenter study included patients with colorectal FDIP lesions (Connect IIC+/III, Kudo Vn or Sano IIIb;1000 µm invasion without other risk factors). Independent predictors of curative resection were identified by multivariable logistic regression. Carbon footprint (CO₂e) and economic analyses were based on life-cycle data for ESD, surgery, and hospitalization. Results Between January 2024 and May 2025, 190 patients (16 centers) underwent diagnostic ESD. Curative resection was achieved in 43% (n=86) of cases. In 16% (n=31) of cases the resection was considered at intermediate (expanded curative resection), and after multidisciplinary discussion only 6 patients underwent surgery. Seventy-three per cent (n=73) were considered at high risk (non-curative resection) and surgery was recommended. Overall, 107 patients (56%) avoided surgery and continued with endoscopic surveillance. CONNECT III classification (OR 0.42, 95% CI 0.18–0.98) and presence of retraction sign (OR 0.48, 95% CI 0.23–0.99) were independent negative predictors of curative resection. Compared with systematic upfront surgery, the diagnostic ESD strategy resulted in lower carbon emissions (222.2 vs 240.2 kg CO₂e per patient), reduced hospital stay (0.98 vs 3.5 days), and lower overall cost (€7,930 vs €12,960 per patient). Conclusions A diagnostic ESD-first strategy for FDIP colorectal lesions enables definitive staging while reducing the need for surgery, environmental impact, and healthcare costs, supporting its use as a sustainable alternative to upfront surgery in selected patients. Article published online: 05 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 5 June 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 03) , S48
Clinical impact and environmental footprint of diagnostic endoscopic dissection versus first line surgery for colorectal lesions harboring focal deep invasive pattern
Aims Endoscopic submucosal dissection (ESD) can achieve curative resection for T1 colorectal cancers fulfilling low-risk histological criteria. However, optical diagnosis does not always accurately predict submucosal invasion depth, and lesions with focal deep invasive patterns (FDIP) are often referred directly to surgery. A first-line diagnostic ESD strategy, performing en bloc resection in these lesions to obtain definitive histopathology before deciding on surgery, may represent a safe and cost-effective alternative. This study compared the clinical, environmental, and economic impact of diagnostic ESD versus upfront surgery for FDIP lesions [1] [2] [3] [4] [5] [6]. Methods This prospective multicenter study included patients with colorectal FDIP lesions (Connect IIC+/III, Kudo Vn or Sano IIIb;1000 µm invasion without other risk factors). Independent predictors of curative resection were identified by multivariable logistic regression. Carbon footprint (CO₂e) and economic analyses were based on life-cycle data for ESD, surgery, and hospitalization. Results Between January 2024 and May 2025, 190 patients (16 centers) underwent diagnostic ESD. Curative resection was achieved in 43% (n=86) of cases. In 16% (n=31) of cases the resection was considered at intermediate (expanded curative resection), and after multidisciplinary discussion only 6 patients underwent surgery. Seventy-three per cent (n=73) were considered at high risk (non-curative resection) and surgery was recommended. Overall, 107 patients (56%) avoided surgery and continued with endoscopic surveillance. CONNECT III classification (OR 0.42, 95% CI 0.18–0.98) and presence of retraction sign (OR 0.48, 95% CI 0.23–0.99) were independent negative predictors of curative resection. Compared with systematic upfront surgery, the diagnostic ESD strategy resulted in lower carbon emissions (222.2 vs 240.2 kg CO₂e per patient), reduced hospital stay (0.98 vs 3.5 days), and lower overall cost (€7,930 vs €12,960 per patient). Conclusions A diagnostic ESD-first strategy for FDIP colorectal lesions enables definitive staging while reducing the need for surgery, environmental impact, and healthcare costs, supporting its use as a sustainable alternative to upfront surgery in selected patients. Article published online: 05 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 12 May 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (07) , 753-765
Outcomes of perforation after colorectal endoscopic submucosal dissection in a large prospective multicenter cohort
Background Endoscopic submucosal dissection (ESD) offers better oncological outcomes and lower recurrence rates, but is limited in colorectal use owing to concerns about adverse events, especially perforation. This study aimed to explore the clinical burden and risk factors for perforation in a Western cohort. Methods Analysis of intraprocedural and delayed perforations from a prospective cohort study including 3770 colorectal ESDs performed at one Belgian and 12 French centers between September 2019 and September 2022. Results Intraprocedural perforation (n = 314; 8.3 %) or delayed perforation (n = 22; 0.6 %) occurred in 336/3770 procedures (8.9 %). Conservative management was effective for 308/336 perforations (91.7 %), especially for intraprocedural perforations (n = 304 /314; 96.8 %). Delayed perforation frequently required emergent surgery (n = 18/22; 81.8 %). Multivariable analysis identified factors associated with intraprocedural perforation, including previous resection (odds ratio [OR] 1.9, 95%CI 1.3 to 2.7), lesion size ≥ 50 mm (OR 1.5, 95%CI 1.2 to 1.9), poor maneuvrability (OR 2.0, 95%CI 1.4 to 2.5) and severe fibrosis (OR 4.4, 95%CI 3.2 to 6.1). Proximal colonic location and severe fibrosis were associated with increased risk of delayed perforation. A perforation ≥ 5 mm (OR 8.9, 95 %CI 1.0 to 76.5) and fever (OR 9.5, 95 %CI 2.4 to 38.0) or abdominal pain (OR 26.6, 95 %CI 3.3 to 213.8) were associated with surgery after intraprocedural perforation (univariable analysis). No deaths were directly linked to perforation, but one death occurred due to delayed bleeding. Conclusions ESD-related perforations are often manageable conservatively, with surgery being rare; however, delayed perforations remain challenging and often require surgery. Patients should be informed of both the benefits and risks.
- 12 May 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (07) , 753-765
Outcomes of perforation after colorectal endoscopic submucosal dissection in a large prospective multicenter cohort
Background Endoscopic submucosal dissection (ESD) offers better oncological outcomes and lower recurrence rates, but is limited in colorectal use owing to concerns about adverse events, especially perforation. This study aimed to explore the clinical burden and risk factors for perforation in a Western cohort. Methods Analysis of intraprocedural and delayed perforations from a prospective cohort study including 3770 colorectal ESDs performed at one Belgian and 12 French centers between September 2019 and September 2022. Results Intraprocedural perforation (n = 314; 8.3 %) or delayed perforation (n = 22; 0.6 %) occurred in 336/3770 procedures (8.9 %). Conservative management was effective for 308/336 perforations (91.7 %), especially for intraprocedural perforations (n = 304 /314; 96.8 %). Delayed perforation frequently required emergent surgery (n = 18/22; 81.8 %). Multivariable analysis identified factors associated with intraprocedural perforation, including previous resection (odds ratio [OR] 1.9, 95%CI 1.3 to 2.7), lesion size ≥ 50 mm (OR 1.5, 95%CI 1.2 to 1.9), poor maneuvrability (OR 2.0, 95%CI 1.4 to 2.5) and severe fibrosis (OR 4.4, 95%CI 3.2 to 6.1). Proximal colonic location and severe fibrosis were associated with increased risk of delayed perforation. A perforation ≥ 5 mm (OR 8.9, 95 %CI 1.0 to 76.5) and fever (OR 9.5, 95 %CI 2.4 to 38.0) or abdominal pain (OR 26.6, 95 %CI 3.3 to 213.8) were associated with surgery after intraprocedural perforation (univariable analysis). No deaths were directly linked to perforation, but one death occurred due to delayed bleeding. Conclusions ESD-related perforations are often manageable conservatively, with surgery being rare; however, delayed perforations remain challenging and often require surgery. Patients should be informed of both the benefits and risks.
- 12 May 2026
Outcomes of perforation after colorectal endoscopic submucosal dissection in a large prospective multicenter cohort.
BACKGROUND : Endoscopic submucosal dissection (ESD) offers better oncological outcomes and lower recurrence rates, but is limited in colorectal use owing to concerns about adverse events, especially perforation. This study aimed to explore the clinical burden and risk factors for perforation in a Western cohort. METHODS : Analysis of intraprocedural and delayed perforations from a prospective cohort study including 3770 colorectal ESDs performed at one Belgian and 12 French centers between September 2019 and September 2022. RESULTS: Intraprocedural perforation (n = 314; 8.3 %) or delayed perforation (n = 22; 0.6 %) occurred in 336/3770 procedures (8.9 %). Conservative management was effective for 308/336 perforations (91.7 %), especially for intraprocedural perforations (n = 304 /314; 96.8 %). Delayed perforation frequently required emergent surgery (n = 18/22; 81.8 %). Multivariable analysis identified factors associated with intraprocedural perforation, including previous resection (odds ratio [OR] 1.9, 95%CI 1.3 to 2.7), lesion size ≥ 50 mm (OR 1.5, 95%CI 1.2 to 1.9), poor maneuvrability (OR 2.0, 95%CI 1.4 to 2.5) and severe fibrosis (OR 4.4, 95%CI 3.2 to 6.1). Proximal colonic location and severe fibrosis were associated with increased risk of delayed perforation. A perforation ≥ 5 mm (OR 8.9, 95 %CI 1.0 to 76.5) and fever (OR 9.5, 95 %CI 2.4 to 38.0) or abdominal pain (OR 26.6, 95 %CI 3.3 to 213.8) were associated with surgery after intraprocedural perforation (univariable analysis). No deaths were directly linked to perforation, but one death occurred due to delayed bleeding. CONCLUSIONS: ESD-related perforations are often manageable conservatively, with surgery being rare; however, delayed perforations remain challenging and often require surgery. Patients should be informed of both the benefits and risks.
- 12 May 2026
Outcomes of perforation after colorectal endoscopic submucosal dissection in a large prospective multicenter cohort.
BACKGROUND : Endoscopic submucosal dissection (ESD) offers better oncological outcomes and lower recurrence rates, but is limited in colorectal use owing to concerns about adverse events, especially perforation. This study aimed to explore the clinical burden and risk factors for perforation in a Western cohort. METHODS : Analysis of intraprocedural and delayed perforations from a prospective cohort study including 3770 colorectal ESDs performed at one Belgian and 12 French centers between September 2019 and September 2022. RESULTS: Intraprocedural perforation (n = 314; 8.3 %) or delayed perforation (n = 22; 0.6 %) occurred in 336/3770 procedures (8.9 %). Conservative management was effective for 308/336 perforations (91.7 %), especially for intraprocedural perforations (n = 304 /314; 96.8 %). Delayed perforation frequently required emergent surgery (n = 18/22; 81.8 %). Multivariable analysis identified factors associated with intraprocedural perforation, including previous resection (odds ratio [OR] 1.9, 95%CI 1.3 to 2.7), lesion size ≥ 50 mm (OR 1.5, 95%CI 1.2 to 1.9), poor maneuvrability (OR 2.0, 95%CI 1.4 to 2.5) and severe fibrosis (OR 4.4, 95%CI 3.2 to 6.1). Proximal colonic location and severe fibrosis were associated with increased risk of delayed perforation. A perforation ≥ 5 mm (OR 8.9, 95 %CI 1.0 to 76.5) and fever (OR 9.5, 95 %CI 2.4 to 38.0) or abdominal pain (OR 26.6, 95 %CI 3.3 to 213.8) were associated with surgery after intraprocedural perforation (univariable analysis). No deaths were directly linked to perforation, but one death occurred due to delayed bleeding. CONCLUSIONS: ESD-related perforations are often manageable conservatively, with surgery being rare; however, delayed perforations remain challenging and often require surgery. Patients should be informed of both the benefits and risks.