Instituo CUF Porto
Type
HealthcareLocations
Matosinhos Municipality, PortugalLatest Publications
- Open Access
- 12 November 2026
- Published by European Respiratory Society (ERS) in ERJ Open Research
Validation of a new automated and privacy-preserving cough monitor
Background: Objective cough monitoring is increasingly important for chronic cough assessment and therapeutic evaluation, yet existing systems may be limited by privacy concerns, user burden, and challenges associated with prolonged real-world monitoring. Aim: To evaluate the diagnostic performance and acceptability of the C-mo System, a multimodal wearable cough monitor integrating abdominal electromyography (EMG) and EMG-triggered audio acquisition. Methods: In this multicentre prospective study ( NCT05989698 ), consecutive participants with cough underwent 24 h of ambulatory monitoring using the C-mo system. Cough detection performance was evaluated against a continuous audio reference standard using blinded annotation. Sensitivity, specificity and false-positive rate were calculated overall and across age, body mass index (BMI), cough frequency, and comorbidities subgroups. Acceptability was assessed using a study-specific questionnaire. Results: Fifty-four participants completed monitoring, contributing 1344 h of recordings. Mean monitoring duration was 24 h 54 min [24 h 50 min–24 h 58 min], with C-mo's EMG-based privacy mechanism limiting audio recording to 17.7% of the monitoring time. Sensitivity, specificity and false-positive rate were 93.81% (Q1 80.43, Q3 97.96), 99.97% (Q1 99.95, Q3 99.99) and 0.95 coughs/hour (Q1 0.47, Q3 1.71), respectively. Diagnostic performance remained consistently high across subgroups. Participants reported high levels of comfort, and acceptability, with favourable responses exceeding 80% across all questionnaire domains. Overall satisfaction was high, and most participants considered prolonged monitoring acceptable. Conclusion: The C-mo system demonstrated high diagnostic accuracy and acceptability during prolonged real-world monitoring. These findings support the feasibility of multimodal, privacy-conscious ambulatory cough monitoring and provide a foundation for future long-term applications.
- 12 November 2026
- Published by European Respiratory Society (ERS) in ERJ Open Research
Open AccessValidation of a new automated and privacy-preserving cough monitor
Background: Objective cough monitoring is increasingly important for chronic cough assessment and therapeutic evaluation, yet existing systems may be limited by privacy concerns, user burden, and challenges associated with prolonged real-world monitoring. Aim: To evaluate the diagnostic performance and acceptability of the C-mo System, a multimodal wearable cough monitor integrating abdominal electromyography (EMG) and EMG-triggered audio acquisition. Methods: In this multicentre prospective study ( NCT05989698 ), consecutive participants with cough underwent 24 h of ambulatory monitoring using the C-mo system. Cough detection performance was evaluated against a continuous audio reference standard using blinded annotation. Sensitivity, specificity and false-positive rate were calculated overall and across age, body mass index (BMI), cough frequency, and comorbidities subgroups. Acceptability was assessed using a study-specific questionnaire. Results: Fifty-four participants completed monitoring, contributing 1344 h of recordings. Mean monitoring duration was 24 h 54 min [24 h 50 min–24 h 58 min], with C-mo's EMG-based privacy mechanism limiting audio recording to 17.7% of the monitoring time. Sensitivity, specificity and false-positive rate were 93.81% (Q1 80.43, Q3 97.96), 99.97% (Q1 99.95, Q3 99.99) and 0.95 coughs/hour (Q1 0.47, Q3 1.71), respectively. Diagnostic performance remained consistently high across subgroups. Participants reported high levels of comfort, and acceptability, with favourable responses exceeding 80% across all questionnaire domains. Overall satisfaction was high, and most participants considered prolonged monitoring acceptable. Conclusion: The C-mo system demonstrated high diagnostic accuracy and acceptability during prolonged real-world monitoring. These findings support the feasibility of multimodal, privacy-conscious ambulatory cough monitoring and provide a foundation for future long-term applications.
- Open Access
Indoor Tanning in Europe: Temporal Trends, Sociodemographic Determinants from the Euromelanoma Campaign (2009–2018)
Background: In 2009, the International Agency for Research on Cancer (IARC) classified UV-emitting tanning devices as carcinogenic to humans (Group 1). This study aimed to describe ten-year trends in sunbed use prevalence across Europe and examine differences by country and sociodemographic and phenotypic characteristics. Methods: Euromelanoma survey data collected between 2009 and 2018 from 33 countries were analysed among individuals voluntarily attending free skin examinations. Annual sunbed use prevalence and 95% confidence intervals were estimated by country, with stratified analyses by gender, age, education level, and skin phototype. Associations with sunbed use were investigated using mixed-effects logistic regression models. Results: A total of 343,675 participants were included. Among Euromelanoma campaign participants, current sunbed use declined over the study period, declining from approximately 12.8% in 2009 to below 6% by 2018, despite year-to-year fluctuations. Women, adults aged 20–35 years and individuals with skin phototypes III–IV exhibited the highest odds of sunbed use (OR Female vs. Male = 3.01, 95%CI [2.91–3.12], OR 20–35 vs. >35 = 2.54, 95%CI [2.47–2.61], and OR Type III–IV vs. Type I–II = 1.52, 95%CI [1.47–1.56], respectively). Marked heterogeneity was observed across countries. Mixed-effects analyses showed a strong temporal decline that was significantly steeper among younger participants, particularly those aged 20–35 years, than among individuals older than 35 years. Conclusions: Indoor tanning prevalence declined across Europe between 2009 and 2018, during a period of evolving post-IARC regulatory and preventive measures. Persistent sociodemographic disparities and substantial between-country heterogeneity highlight the need for targeted, country-specific prevention strategies and continued monitoring of indoor tanning behaviors.
Open AccessIndoor Tanning in Europe: Temporal Trends, Sociodemographic Determinants from the Euromelanoma Campaign (2009–2018)
Background: In 2009, the International Agency for Research on Cancer (IARC) classified UV-emitting tanning devices as carcinogenic to humans (Group 1). This study aimed to describe ten-year trends in sunbed use prevalence across Europe and examine differences by country and sociodemographic and phenotypic characteristics. Methods: Euromelanoma survey data collected between 2009 and 2018 from 33 countries were analysed among individuals voluntarily attending free skin examinations. Annual sunbed use prevalence and 95% confidence intervals were estimated by country, with stratified analyses by gender, age, education level, and skin phototype. Associations with sunbed use were investigated using mixed-effects logistic regression models. Results: A total of 343,675 participants were included. Among Euromelanoma campaign participants, current sunbed use declined over the study period, declining from approximately 12.8% in 2009 to below 6% by 2018, despite year-to-year fluctuations. Women, adults aged 20–35 years and individuals with skin phototypes III–IV exhibited the highest odds of sunbed use (OR Female vs. Male = 3.01, 95%CI [2.91–3.12], OR 20–35 vs. >35 = 2.54, 95%CI [2.47–2.61], and OR Type III–IV vs. Type I–II = 1.52, 95%CI [1.47–1.56], respectively). Marked heterogeneity was observed across countries. Mixed-effects analyses showed a strong temporal decline that was significantly steeper among younger participants, particularly those aged 20–35 years, than among individuals older than 35 years. Conclusions: Indoor tanning prevalence declined across Europe between 2009 and 2018, during a period of evolving post-IARC regulatory and preventive measures. Persistent sociodemographic disparities and substantial between-country heterogeneity highlight the need for targeted, country-specific prevention strategies and continued monitoring of indoor tanning behaviors.
- Open Access
- 21 September 2026
- Published by Taylor & Francis in European Journal of General Practice
- Vol. 32 (1) , 2729221
Discrepancies in low-value practices across cardiovascular disease prevention guidelines. A narrative review
Low-value practices are interventions that do not provide health benefits due to lack of effectiveness or associated risks that outweigh the potential benefits. The purpose of this study is to demonstrate discrepancies across various cardiovascular prevention guidelines published by numerous institutions and organisations, and establish an objective overview of the current state of the art and formulate recommendations for general practitioners. A narrative review of clinical practice guidelines for CVD prevention published in English between January 2017 and December 2025 was conducted. Searches focused on major European, British, North American, and Australian scientific societies; only guidelines containing explicit recommendations on low-value or unnecessary practices were included. We identified the scientific evidence supporting these recommendations and searched for ongoing clinical trials - specifically in cases where recommendations were based on a single randomised trial, large non-randomised studies, retrospective data, or expert opinion. Guidelines show significant discrepancies regarding recommendations for low-value practices. These primarily relate to the evaluation of the coronary artery calcium (CAC) score, determination of lipoprotein(a) (Lp(a)), screening for abdominal aortic aneurysm (AAA), and the initiation of lipid-lowering treatment in older adults. Controversy and uncertainty were most evident when recommendations were based on non-randomised clinical trials or expert opinion. While some guidelines align, others exhibit clear discrepancies, illustrating the uncertainty of the scientific evidence and differing interpretations. Until robust evidence from high-quality clinical trials becomes available, clinicians should exercise caution regarding certain screening procedures and therapeutic interventions in CVD prevention within general practice.
- 21 September 2026
- Published by Taylor & Francis in European Journal of General Practice
- Vol. 32 (1) , 2729221
Open AccessDiscrepancies in low-value practices across cardiovascular disease prevention guidelines. A narrative review
Low-value practices are interventions that do not provide health benefits due to lack of effectiveness or associated risks that outweigh the potential benefits. The purpose of this study is to demonstrate discrepancies across various cardiovascular prevention guidelines published by numerous institutions and organisations, and establish an objective overview of the current state of the art and formulate recommendations for general practitioners. A narrative review of clinical practice guidelines for CVD prevention published in English between January 2017 and December 2025 was conducted. Searches focused on major European, British, North American, and Australian scientific societies; only guidelines containing explicit recommendations on low-value or unnecessary practices were included. We identified the scientific evidence supporting these recommendations and searched for ongoing clinical trials - specifically in cases where recommendations were based on a single randomised trial, large non-randomised studies, retrospective data, or expert opinion. Guidelines show significant discrepancies regarding recommendations for low-value practices. These primarily relate to the evaluation of the coronary artery calcium (CAC) score, determination of lipoprotein(a) (Lp(a)), screening for abdominal aortic aneurysm (AAA), and the initiation of lipid-lowering treatment in older adults. Controversy and uncertainty were most evident when recommendations were based on non-randomised clinical trials or expert opinion. While some guidelines align, others exhibit clear discrepancies, illustrating the uncertainty of the scientific evidence and differing interpretations. Until robust evidence from high-quality clinical trials becomes available, clinicians should exercise caution regarding certain screening procedures and therapeutic interventions in CVD prevention within general practice.
- 5 September 2026
- Published by European Respiratory Society (ERS)
- Vol. 68 (suppl 70) , PA5865
Validation of a new automated and privacy-preserving cough monitor
Cough monitoring is increasingly used in clinical trials, but existing tools rely on continuous audio recording, raising privacy concerns. C-mo is a cough monitor that detects cough events without continuous sound recording. This study aimed to evaluate whether the cough monitor C-mo can accurately detect cough events in real-world use. A prospective observational study was conducted with people with cough (NCT05989698). Characterization data (age, body mass index [BMI] and primary disease group) were collected, and participants used C-mo for 24h. C-mo is worn on the abdomen and only activates its microphone when cough-related muscle activity is detected in EMG signals. In this validation study, continuous audio was also recorded as a reference. The gold-standard was established by majority vote from ≥2 physicians who reviewed the audio recordings and annotated the cough events. Cough detection performance was assessed by comparing C-mo’s cough timestamps with the gold standard, using sensitivity and specificity. Performance was examined across age, cough rate, primary disease groups, and BMI (Figure 1). Fifty-four participants (median age 52 years [IQR 40–64]) were included. C-mo achieved a median sensitivity of 95.0% (IQR 87.2–98.5%) and specificity of 99.9% (IQR 99.9–99.9%) compared with the gold standard. There were no significant differences across age groups, cough rates, BMI or diseases. C-mo showed accurate cough detection across a diverse patient population monitored in real-world use.
- 5 September 2026
- Published by European Respiratory Society (ERS)
- Vol. 68 (suppl 70) , PA5865
Validation of a new automated and privacy-preserving cough monitor
Cough monitoring is increasingly used in clinical trials, but existing tools rely on continuous audio recording, raising privacy concerns. C-mo is a cough monitor that detects cough events without continuous sound recording. This study aimed to evaluate whether the cough monitor C-mo can accurately detect cough events in real-world use. A prospective observational study was conducted with people with cough (NCT05989698). Characterization data (age, body mass index [BMI] and primary disease group) were collected, and participants used C-mo for 24h. C-mo is worn on the abdomen and only activates its microphone when cough-related muscle activity is detected in EMG signals. In this validation study, continuous audio was also recorded as a reference. The gold-standard was established by majority vote from ≥2 physicians who reviewed the audio recordings and annotated the cough events. Cough detection performance was assessed by comparing C-mo’s cough timestamps with the gold standard, using sensitivity and specificity. Performance was examined across age, cough rate, primary disease groups, and BMI (Figure 1). Fifty-four participants (median age 52 years [IQR 40–64]) were included. C-mo achieved a median sensitivity of 95.0% (IQR 87.2–98.5%) and specificity of 99.9% (IQR 99.9–99.9%) compared with the gold standard. There were no significant differences across age groups, cough rates, BMI or diseases. C-mo showed accurate cough detection across a diverse patient population monitored in real-world use.
- 18 August 2026
- Published by Elsevier in Radiography
- Vol. 32 (6) , 103537
Comparison of Gonadal Dose Estimation Using Treatment Planning Systems and Monte Carlo Methods in Pelvic Radiotherapy
- 18 August 2026
- Published by Elsevier in Radiography
- Vol. 32 (6) , 103537
Comparison of Gonadal Dose Estimation Using Treatment Planning Systems and Monte Carlo Methods in Pelvic Radiotherapy
- 17 July 2026
- Published by European Respiratory Society (ERS)
- Vol. 12 (suppl 20) , TP116
Impact of non-patient coughs on the reliability of cough monitoring
Automated audio-based cough monitors cannot distinguish cough source, potentially compromising measurement reliability in presence of coughs from others. Whether alternative detection approaches are robust to non-patient coughs is unclear. This study assessed the impact of non-patient coughs on cough monitoring and evaluated the robustness of an electromyography (EMG)-based cough monitor (C-mo). This was a post-hoc analysis of a prospective validation (NCT05989698). People with cough wore C-mo for 24h during daily life, with continuous audio recorded as reference. Cough events were annotated by ≥2 independent physicians. All cough events were first annotated regardless of source, after which non-patient coughs were identified using contextual audio. EMG signals were used when cough source attribution was unclear. For each participant, cough frequency was calculated including all coughs (patient + non-patient) and patient coughs only. Overestimation was quantified as the difference between these values. Robustness was assessed as the percentage of non-patient coughs filtered out by C-mo. Fifty-four participants (median 52y; IQR 40–64) were included. Including non-patient coughs resulted in a mean overestimation of cough frequency of 43% (3.5 coughs/hour), with contamination ranging from 0% to 457%. C-mo filtered-out 98% of the non-patient coughs. Figure 1 shows an example from a patient. Non-patient coughs substantially affected cough measurement reliability. C-mo showed high robustness to this source of noise.
- 17 July 2026
- Published by European Respiratory Society (ERS)
- Vol. 12 (suppl 20) , TP116
Impact of non-patient coughs on the reliability of cough monitoring
Automated audio-based cough monitors cannot distinguish cough source, potentially compromising measurement reliability in presence of coughs from others. Whether alternative detection approaches are robust to non-patient coughs is unclear. This study assessed the impact of non-patient coughs on cough monitoring and evaluated the robustness of an electromyography (EMG)-based cough monitor (C-mo). This was a post-hoc analysis of a prospective validation (NCT05989698). People with cough wore C-mo for 24h during daily life, with continuous audio recorded as reference. Cough events were annotated by ≥2 independent physicians. All cough events were first annotated regardless of source, after which non-patient coughs were identified using contextual audio. EMG signals were used when cough source attribution was unclear. For each participant, cough frequency was calculated including all coughs (patient + non-patient) and patient coughs only. Overestimation was quantified as the difference between these values. Robustness was assessed as the percentage of non-patient coughs filtered out by C-mo. Fifty-four participants (median 52y; IQR 40–64) were included. Including non-patient coughs resulted in a mean overestimation of cough frequency of 43% (3.5 coughs/hour), with contamination ranging from 0% to 457%. C-mo filtered-out 98% of the non-patient coughs. Figure 1 shows an example from a patient. Non-patient coughs substantially affected cough measurement reliability. C-mo showed high robustness to this source of noise.
- 17 July 2026
- Published by European Respiratory Society (ERS)
- Vol. 12 (suppl 20) , OP10
Validation of a new automated and privacy-preserving cough monitor
Cough monitoring is increasingly used in clinical trials, but existing tools rely on continuous audio recording, raising privacy concerns. C-mo is a cough monitor that detects cough events without continuous sound recording. This study aimed to evaluate whether the cough monitor C-mo can accurately detect cough events in real-world use. A prospective observational study was conducted with people with cough (NCT05989698). Characterization data (age, body mass index [BMI] and primary disease group) were collected, and participants used C-mo for 24h. C-mo is worn on the abdomen and only activates its microphone when cough-related muscle activity is detected in EMG signals. In this validation study, continuous audio was also recorded as a reference. The gold-standard was established by majority vote from ≥2 physicians who reviewed the audio recordings and annotated the cough events. Cough detection performance was assessed by comparing C-mo’s cough timestamps with the gold standard, using sensitivity and specificity. Performance was examined across age, cough rate, primary disease groups, and BMI (Figure 1). Fifty-four participants (median age 52 years [IQR 40–64]) were included. C-mo achieved a median sensitivity of 95.0% (IQR 87.2–98.5%) and specificity of 99.9% (IQR 99.9–99.9%) compared with the gold standard. There were no significant differences across age groups, cough rates, BMI or diseases. C-mo showed accurate cough detection across a diverse patient population monitored in real-world use.
- 17 July 2026
- Published by European Respiratory Society (ERS)
- Vol. 12 (suppl 20) , OP10
Validation of a new automated and privacy-preserving cough monitor
Cough monitoring is increasingly used in clinical trials, but existing tools rely on continuous audio recording, raising privacy concerns. C-mo is a cough monitor that detects cough events without continuous sound recording. This study aimed to evaluate whether the cough monitor C-mo can accurately detect cough events in real-world use. A prospective observational study was conducted with people with cough (NCT05989698). Characterization data (age, body mass index [BMI] and primary disease group) were collected, and participants used C-mo for 24h. C-mo is worn on the abdomen and only activates its microphone when cough-related muscle activity is detected in EMG signals. In this validation study, continuous audio was also recorded as a reference. The gold-standard was established by majority vote from ≥2 physicians who reviewed the audio recordings and annotated the cough events. Cough detection performance was assessed by comparing C-mo’s cough timestamps with the gold standard, using sensitivity and specificity. Performance was examined across age, cough rate, primary disease groups, and BMI (Figure 1). Fifty-four participants (median age 52 years [IQR 40–64]) were included. C-mo achieved a median sensitivity of 95.0% (IQR 87.2–98.5%) and specificity of 99.9% (IQR 99.9–99.9%) compared with the gold standard. There were no significant differences across age groups, cough rates, BMI or diseases. C-mo showed accurate cough detection across a diverse patient population monitored in real-world use.
- Open Access
- 30 January 2026
- Published by Elsevier in Revista Portuguesa de Cardiologia
- Vol. 45 (3) , 169-170
Response to the Letter to the Editor – Integrating natriuretic peptide screening in diabetic patients: Practical insights from a neurosurgical perspective
- 30 January 2026
- Published by Elsevier in Revista Portuguesa de Cardiologia
- Vol. 45 (3) , 169-170
Open AccessResponse to the Letter to the Editor – Integrating natriuretic peptide screening in diabetic patients: Practical insights from a neurosurgical perspective
- Open Access
- 28 November 2025
- Published by Elsevier in Revista Portuguesa de Cardiologia
- Vol. 45 (2) , 51-64
Lipid-lowering therapy and LDL cholesterol control among high- and very high-risk patients in Portugal: An analysis of the SANTORINI study
- 28 November 2025
- Published by Elsevier in Revista Portuguesa de Cardiologia
- Vol. 45 (2) , 51-64
Open AccessLipid-lowering therapy and LDL cholesterol control among high- and very high-risk patients in Portugal: An analysis of the SANTORINI study
- 11 October 2025
- Published by Elsevier in Journal of the American Academy of Dermatology
- Vol. 94 (2) , 652-653
Modern definitions of periungual pigmentation (Hutchinson sign): Results of an expert opinion consensus conference
- 11 October 2025
- Published by Elsevier in Journal of the American Academy of Dermatology
- Vol. 94 (2) , 652-653
Modern definitions of periungual pigmentation (Hutchinson sign): Results of an expert opinion consensus conference