Type
Healthcare
Locations
Centurion, South Africa

Latest Publications

  • Open Access

    Magnet induced small bowel volvulus in a paediatric patient: a case report

    by Tshepang Arthur Motsepe, Kasongo Mare‑Josee Kasakanga, Shaan Marthinus Maritz

    Ingestion of magnetic objects in children can cause life-threatening complications, such as small bowel perforation and peritonitis. Magnets are known to cause localised bowel ischaemia due to pressure necrosis that results in perforations and fistulae. However, the occurrence of small bowel volvulus, which carries more serious outcomes from the rotational mesenteric strangulation that leads to widespread bowel ischaemia and necrosis, is rarely reported. We present the case of a 4-year-old boy who developed an acute abdomen after swallowing magnetic pellets, which were discovered during laparotomy. Although magnet ingestion is a recognised cause of abdominal surgical emergencies, the risk of a volvulus underscores the need for a more urgent and decisive approach to obviate significant morbidity and mortality.


  • Open Access

    Defining and responding to the contextual drivers for implementation of antimicrobial stewardship in 14 neonatal units in South Africa

    by Dena Van Den Bergh, Esmita Charani, Angela Dramowski, Ama Sakoa Annor, Michelle Gijzelaar, Angeliki Messina, Andriette Van Jaarsveld, Debra A Goff, Pavel Prusakov, Liezl Balfour, et al.

    Background: Research on the contextual drivers of antimicrobial stewardship (AMS) programme interventions in neonatal units is limited. Methods: As part of a prospective mixed-methods multidisciplinary neonatal AMS (NeoAMS) interventional study in 14 South African hospitals, we applied a three-phased process to assess implementation barriers and contextual drivers experienced by participating health professionals. The study included: (Phase one; P1) a survey of pre-intervention barriers and enablers; (P2) written feedback during the study intervention phase; and (P3) semi-structured exit interviews. Results: Respondents to the P1 survey (n = 100) identified 15 barriers, 9 in the domain of personnel resources, including staffing, time and workload constraints. Other barriers related to limited access to antimicrobial use and surveillance trends, complexity of neonatal care, absence of multidisciplinary team (MDT) AMS and change resistance. For P2, written feedback during implementation (n = 42) confirmed that the MDT approach facilitated systems changes, including policy adaptations, process improvements, strengthened infection control practices, and expansion of AMS MDT roles. MDT benefits were described as aligned team purpose, improved communication, and knowledge sharing. Reported challenges included time to meet and building trust. In P3 interviews (n = 42), improved interpersonal communication, trust, personal growth and confidence building were cited as highlights of working in multidisciplinary AMS teams. Extending the MDT approach to other hospitals, training more health professionals in AMS and increasing management involvement were identified as priorities going forward. Conclusions: Understanding the organizational and interprofessional context for NeoAMS implementation enabled an MDT approach to develop and optimize neonatal AMS with potential for adoption in similar resource-constrained settings.


  • Open Access

    Commentary on the published position statement regarding the pathogenesis of fetal basal ganglia- thalamic hypoxic-ischaemic injury

    by J Anthony, J Smith, L Murray, G F Kirsten, G Gericke, Y Kara, V Davies, D Pearce, R Van Toorn, M M Lippert, et al.


  • Open Access

    New insertable cardiac monitors show high diagnostic yield and good safety profile in real-world clinical practice: results from the international prospective observational SMART Registry

    by Fabio Quartieri, Manyam Harish, Leonardo Calò, Iftikhar Ebrahim, Antonio Fusco, Stephen Mester, Filippo Cauti, Seung-Jung Park, Pietro Francia, Marco Giovagnoni, et al.

    Insertable cardiac monitors (ICMs) are indicated for long-term monitoring of unexplained syncope or palpitations, and for detection of bradycardia, ventricular tachycardia, and/or atrial fibrillation (AF). The aim of our study was to evaluate the safety and clinical value associated with a new generation ICM (Confirm Rx™, Abbott, Illinois, USA), featuring a new remote monitoring system based on smartphone patient applications. The SMART Registry is an international prospective observational study. The main endpoints were ICM safety (incidence of serious adverse device and procedure-related events (SADEs) at 1 month), ICM clinical value (incidence of device-detected true arrhythmias and of clinical diagnoses and interventions), and patient-reported experience measurements (PREMs). A total of 1400 subjects were enrolled. ICM indications included syncope (49.1%), AF (18.8%), unexplained palpitations (13.6%), risk of ventricular arrhythmia (6.6%), and cryptogenic stroke (6.0%). Freedom from SADEs at 1 month was 99.4% (95% Confidence Interval: 98.8–99.7%). In the 6-month monitoring period, the ICM detected true cardiac arrhythmias in 45.7% of patients and led to clinical interventions in a relevant proportion of patients; in particular, a pacemaker implant was performed after bradycardia detection in 8.9% of subjects who received an ICM for syncope and oral anticoagulation therapy was indicated after AF detection in 15.7% of subjects with cryptogenic stroke. PREMs showed that 78.2% of subjects were satisfied with the remote monitoring patient app. The evaluated ICM is associated with an excellent safety profile and high diagnostic yield. Patients reported positive experiences associated with the use of their smartphone for the device remote monitoring.


  • Open Access

    Safety and efficacy of inclisiran in South African patients at high cardiovascular risk: A subanalysis of the ORION phase III clinical trials

    by F Raal, M Abelson, S Blignaut, L Burgess, S Coetzer, I Ebrahim, A Gibbon, D Jansen van Rensburg, M Jaros, L Lombard, et al.

    Background. Inclisiran significantly reduced low-density lipoprotein cholesterol (LDL-C) in individuals with heterozygous familial hypercholesterolaemia, established atherosclerotic cardiovascular disease (ASCVD) or ASCVD risk equivalents (type 2 diabetes, familial hypercholesterolaemia or a 10-year risk of a cardiovascular event ≥20%) in the ORION phase III clinical trials. Infrequent dosing at days 1, 90, 270 and 450 resulted in a mean LDL-C reduction of ~50%. A total of 298 participants from South Africa (SA) were enrolled. Local data are needed to support the use of inclisiran in the SA population, potentially addressing an unmet need for additional LDL-C-lowering therapies. Objectives. To analyse the ORION phase III trial data to assess the efficacy and safety of inclisiran in SA participants. Methods. ORION-9, 10 and 11 were randomised, double-blind, phase III trials. Participants were receiving maximally tolerated statins with or without other lipid-lowering therapies (excluding protein convertase subtilisin/kexin type 9 (PCSK9) inhibitors). Participants were randomised 1:1 to inclisiran sodium 300 mg/284 mg (free acid) or placebo administered at days 1, 90, 270 and 450. The co-primary endpoints were the LDL-C percentage change from baseline to day 510 and the time-averaged percentage change in LDL-C from baseline after day 90 up to day 540. Key secondary endpoints included the absolute change in LDL-C from baseline to day 510, the time-averaged absolute change from baseline after day 90 up to day 540, and changes in other lipids and lipoproteins. Results. The mean age of the participants was 58.6 years (56% male). The mean LDL-C level at baseline was 3.6 mmol/L. At day 510, inclisiran reduced LDL-C levels by 54.2% compared with placebo (95% confidence interval (CI) –61.3 - –47.2; p<0.0001). The corresponding time-averaged reduction in LDL-C was 52.8% (95% CI –57.9 - –47.8; p<0.0001). Treatment-emergent adverse events at the injection site were more common with inclisiran compared with placebo (10.1% v. 0.7%); however, all were mild or moderate in nature and none were persistent. Conclusion. Inclisiran, given in addition to maximally tolerated standard lipid-lowering therapy, is effective and safe and results in robust reductions in LDL-C in SA patients at high cardiovascular risk.


  • Open Access

    MRI findings in chronic exertional compartment syndrome of the forearm: Using signal intensity ratio as a diagnostic tool

    by Jacques Badenhorst, Mark Velleman, Audrey Jansen van Rensburg, Tanita Botha, Nikki van der Walt, Christa Janse van Rensburg

    Background: Chronic exertional compartment syndrome (CECS) of the forearm is a rare but important cause of morbidity amongst athletes involved in strenuous upper limb activities. The diagnosis remains challenging due to the absence of objective, reproducible diagnostic studies. Objectives: To assess and quantify signal intensity (SI) changes of involved muscles in patients with CECS of the forearm compared to healthy control subjects competing in similar sporting disciplines. Also, to objectively measure MRI SIs within muscle compartments when using a pre- and post-exercise regime and calculating a signal intensity ratio (SIR) between post- and pre-exercise studies. Method: The study retrospectively examined MRI scans of patients treated for CECS of the forearm and compared these to the MRI scans of asymptomatic high-level rowers. A specific, reproducible pre- and post-exercise MRI scanning protocol was utilised in both patient and control subjects between 2011 and 2020. Signal intensities were evaluated pre- and post-exercise in involved muscle groups and ratios were calculated. Results: A total of 86 SIs were measured (43 pre- and 43 post-exercise) in nine study participants (five patients and four controls). After post:pre-exercise comparisons, a statistically significant difference was found between control and patient groups (p = 0.0010). The extensor carpi radialis, flexor digitorum profundus and flexor digitorum superficialis muscles were most commonly involved. Conclusion: This study confirms that significant SI changes are apparent in patients with CECS of the forearm when making use of a standardised pre- and post-exercise MRI protocol. Furthermore, SIR may be used to accurately diagnose CECS of the forearm.

  • Open Access

    South African guidelines on the determination of death

    by Thomson D, I Joubert, K De Vasconcellos, F Paruk, S Mokogong, R Mathivha, M McCulloch, B Morrow, D Baker, B Roussouw, et al.

    Death is a medical occurrence that has social, legal, religious and cultural consequences requiring common clinical standards for its diagnosis and legal regulation. This document compiled by the Critical Care Society of Southern Africa outlines the core standards for determination of death in the hospital context. It aligns with the latest evidence-based research and international guidelines and is applicable to the South African context and legal system. The aim is to provide clear medical standards for healthcare providers to follow in the determination of death, thereby promoting safe practices and high-quality care through the use of uniform standards. Adherence to such guidelines will provide assurance to medical staff, patients, their families and the South African public that the determination of death is always undertaken with diligence, integrity, respect and compassion, and is in accordance with accepted medical standards and latest scientific evidence. The consensus guidelines were compiled using the AGREE II checklist with an 18-member expert panel participating in a three-round modified Delphi process. Checklists and advice sheets were created to assist with application of these guidelines in the clinical environment (https://criticalcare.org.za/resource/death-determination-checklists/). Key points • Brain death and circulatory death are the accepted terms for defining death in the hospital context. • Death determination is a clinical diagnosis which can be made with complete certainty provided that all preconditions are met. • The determination of death in children is held to the same standard as in adults but cannot be diagnosed in children <36 weeks’ corrected gestation. • Brain-death testing while on extra-corporeal membrane oxygenation is outlined. • Recommendations are given on handling family requests for accommodation and on consideration of the potential for organ donation. • The use of a checklist combined with a rigorous testing process, comprehensive documentation and adequate counselling of the family are core tenets of death determination. This is a standard of practice to which all clinicians should adhere in end-of-life care.