Texan Eye
Type
HealthcareLocations
Austin, United StatesLatest Publications
- Open Access
- 1 August 2023
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 2219-2230
0.2% Betamethasone Sodium Phosphate: A Multicenter, Randomized, Double-Masked Study to Compare Its Ocular Safety, Tolerability, and Efficacy to Vehicle in Cataract Surgery Subjects
Purpose: To compare the preservative-free corticosteroid 0.2% betamethasone sodium phosphate BID (SURF-201) to vehicle BID in patients undergoing routine cataract surgery. Methods: Phase 2, multicenter, randomized (1:1 ratio), double-masked, vehicle-controlled, parallel-group study in patients scheduled for uncomplicated cataract surgery without the aid of a femtosecond laser. Subjects instilled topical medications for 16 days beginning the day before cataract surgery (Day − 1), 1 dose administered at least 1 hour prior to cataract surgery (on Day 0) and 1 dose on the evening after cataract surgery, and then 2 doses administered each day through Day 15; patients were re-evaluated on Days 22 and 32 to ensure no rebound inflammation. Primary outcome was the difference in the proportion of subjects with anterior chamber cell (ACC) grade 0 between the two groups at Day 15. Secondary outcomes included pain scores and overall safety. Results: There was a statistically significant difference (P=0.004) in the proportion of subjects in the SURF-201 treatment group with an ACC grade of 0 at Day 15 (n=22/39 [56.4%]) compared to subjects in the vehicle treatment group (n=9/43 [20.9%]). There was no statistically significant difference (P=0.528) in the proportion of subjects in the SURF-201 treatment group who had a visual analog scale pain score of 0 at Day 15 (n=35/38 [89.7%]) compared to subjects in the vehicle group (n=33/40 [82.5%]). A slightly higher incidence of adverse events occurred in subjects in the SURF-201 treatment group (n=27/40 [67.5%]) compared to the vehicle treatment group (n=23/43 [53.5%]). Conclusion: SURF-201 is an effective topical, preservative-free corticosteroid when dosed BID for the treatment of postoperative inflammation and prevention of pain in a post-cataract population.
- 1 August 2023
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 17, 2219-2230
Open Access0.2% Betamethasone Sodium Phosphate: A Multicenter, Randomized, Double-Masked Study to Compare Its Ocular Safety, Tolerability, and Efficacy to Vehicle in Cataract Surgery Subjects
Purpose: To compare the preservative-free corticosteroid 0.2% betamethasone sodium phosphate BID (SURF-201) to vehicle BID in patients undergoing routine cataract surgery. Methods: Phase 2, multicenter, randomized (1:1 ratio), double-masked, vehicle-controlled, parallel-group study in patients scheduled for uncomplicated cataract surgery without the aid of a femtosecond laser. Subjects instilled topical medications for 16 days beginning the day before cataract surgery (Day − 1), 1 dose administered at least 1 hour prior to cataract surgery (on Day 0) and 1 dose on the evening after cataract surgery, and then 2 doses administered each day through Day 15; patients were re-evaluated on Days 22 and 32 to ensure no rebound inflammation. Primary outcome was the difference in the proportion of subjects with anterior chamber cell (ACC) grade 0 between the two groups at Day 15. Secondary outcomes included pain scores and overall safety. Results: There was a statistically significant difference (P=0.004) in the proportion of subjects in the SURF-201 treatment group with an ACC grade of 0 at Day 15 (n=22/39 [56.4%]) compared to subjects in the vehicle treatment group (n=9/43 [20.9%]). There was no statistically significant difference (P=0.528) in the proportion of subjects in the SURF-201 treatment group who had a visual analog scale pain score of 0 at Day 15 (n=35/38 [89.7%]) compared to subjects in the vehicle group (n=33/40 [82.5%]). A slightly higher incidence of adverse events occurred in subjects in the SURF-201 treatment group (n=27/40 [67.5%]) compared to the vehicle treatment group (n=23/43 [53.5%]). Conclusion: SURF-201 is an effective topical, preservative-free corticosteroid when dosed BID for the treatment of postoperative inflammation and prevention of pain in a post-cataract population.
- Open Access
- 6 April 2022
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 31 (6) , 382-391
A Randomized, Controlled Comparison of NCX 470 (0.021%, 0.042%, and 0.065%) and Latanoprost 0.005% in Patients With Open-angle Glaucoma or Ocular Hypertension: The Dolomites Study
Précis: NCX 470 0.042% and 0.065% were statistically superior in intraocular pressure (IOP) lowering to latanoprost 0.005%, and NCX 470 0.021% was noninferior. All NCX 470 concentrations were safe and well tolerated. Purpose: The purpose of this study was to compare varying concentrations of NCX 470 (a nitric oxide–donating bimatoprost) to latanoprost in a dose-response safety and efficacy trial. Patients and Methods: Adult patients with bilateral open-angle glaucoma or ocular hypertension were randomized to NCX 470 0.021% (n=111), 0.042% (n=108), 0.065% (n=107), or latanoprost 0.005% (n=107) once daily in the evening. IOP was measured at 8:00 am, 10:00 am, and 4:00 pm at weeks 1, 2, and 4. The primary efficacy endpoint was the reduction from baseline in mean diurnal IOP at week 4. Secondary efficacy endpoints included reductions from baseline in mean diurnal IOP at weeks 1 and 2, and reductions from baseline in time-matched IOP at 8:00 am, 10:00 am, and 4:00 pm at weeks 1, 2, and 4. Adverse events were evaluated. Results: All concentrations of NCX 470 resulted in significant reductions of mean diurnal IOP. The 0.042% and 0.065% concentrations were statistically superior to latanoprost 0.005%, and 0.021% was noninferior to latanoprost for change from baseline in mean diurnal IOP at week 4. The 0.065% concentration was also superior to latanoprost by up to 1.4 mm Hg for reduction from baseline at 8:00 am, 10:00 am, and 4:00 pm at week 4. NCX 470 was safe and well tolerated; conjunctival hyperemia was the most frequently reported adverse event. Conclusions: NCX 470 demonstrated dose-dependent reductions in IOP. The 0.042% and 0.065% concentrations demonstrated significantly greater reductions from baseline in mean diurnal IOP than latanoprost 0.005% at week 4, suggesting that higher concentrations may show even greater efficacy.
- 6 April 2022
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 31 (6) , 382-391
Open AccessA Randomized, Controlled Comparison of NCX 470 (0.021%, 0.042%, and 0.065%) and Latanoprost 0.005% in Patients With Open-angle Glaucoma or Ocular Hypertension: The Dolomites Study
Précis: NCX 470 0.042% and 0.065% were statistically superior in intraocular pressure (IOP) lowering to latanoprost 0.005%, and NCX 470 0.021% was noninferior. All NCX 470 concentrations were safe and well tolerated. Purpose: The purpose of this study was to compare varying concentrations of NCX 470 (a nitric oxide–donating bimatoprost) to latanoprost in a dose-response safety and efficacy trial. Patients and Methods: Adult patients with bilateral open-angle glaucoma or ocular hypertension were randomized to NCX 470 0.021% (n=111), 0.042% (n=108), 0.065% (n=107), or latanoprost 0.005% (n=107) once daily in the evening. IOP was measured at 8:00 am, 10:00 am, and 4:00 pm at weeks 1, 2, and 4. The primary efficacy endpoint was the reduction from baseline in mean diurnal IOP at week 4. Secondary efficacy endpoints included reductions from baseline in mean diurnal IOP at weeks 1 and 2, and reductions from baseline in time-matched IOP at 8:00 am, 10:00 am, and 4:00 pm at weeks 1, 2, and 4. Adverse events were evaluated. Results: All concentrations of NCX 470 resulted in significant reductions of mean diurnal IOP. The 0.042% and 0.065% concentrations were statistically superior to latanoprost 0.005%, and 0.021% was noninferior to latanoprost for change from baseline in mean diurnal IOP at week 4. The 0.065% concentration was also superior to latanoprost by up to 1.4 mm Hg for reduction from baseline at 8:00 am, 10:00 am, and 4:00 pm at week 4. NCX 470 was safe and well tolerated; conjunctival hyperemia was the most frequently reported adverse event. Conclusions: NCX 470 demonstrated dose-dependent reductions in IOP. The 0.042% and 0.065% concentrations demonstrated significantly greater reductions from baseline in mean diurnal IOP than latanoprost 0.005% at week 4, suggesting that higher concentrations may show even greater efficacy.
- Open Access
- 1 February 2022
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 16, 401-409
Rotational Stability of the Clareon Monofocal Aspheric Hydrophobic Acrylic Intraocular Lens 6 Months After Implantation
Purpose: To determine the rotational stability of the Clareon® aspheric, monofocal, intraocular lens (IOL) up to 6 months after implantation. Methods: This prospective, single-arm clinical study evaluated rotational stability of the Clareon IOL in a subset of subjects (n=141, 6 sites) that participated in an investigational device exemption trial for the Clareon IOL. The Clareon model (SY60CL) used in this subset was a non-toric IOL with toric axis markings to measure IOL rotation. All subjects (adults aged ≥ 22 years who required cataract extraction by phacoemulsification) received the Clareon IOL unilaterally. The position of the toric markings was captured using dilated retro-illumination slit-lamp photography and ocular anatomical landmarks. Post-operative rotational stability was assessed by an independent reading center. IOL rotation was defined as the difference between IOL axis of orientation on the day of surgery (≤ 1 hour after surgery) and each post-operative visit. Post-operative IOL-based rotational stability was evaluated at day 0 (day of surgery), day 1, week 1, month 1, and month 6 post-operatively. Results: Compared with day 0, mean absolute IOL rotation was 1.85° on day 1 (n=127) and 2.27° at month 6 (n=124). Absolute IOL rotation ≤ 5° was observed in 95.3% of subjects on day 1 and 92.7% of subjects at month 6, compared with day 0. Between consecutive months 1 and 6 visits, mean absolute rotation was < 1°; 100% of subjects had < 10° rotation and 98.4% had ≤ 5°. The range of rotation on day 1 was 0° to 40.0° because of a subject with ocular trauma; when the trauma-outlier was removed, the mean absolute IOL rotation was 1.6° on day 1 (n=126) and 2.0° at month 6 (n=123). Conclusion: These results support the high rotational stability of the Clareon monofocal IOL and serve as reference of the rotational stability of Clareon toric IOLs.
- 1 February 2022
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 16, 401-409
Open AccessRotational Stability of the Clareon Monofocal Aspheric Hydrophobic Acrylic Intraocular Lens 6 Months After Implantation
Purpose: To determine the rotational stability of the Clareon® aspheric, monofocal, intraocular lens (IOL) up to 6 months after implantation. Methods: This prospective, single-arm clinical study evaluated rotational stability of the Clareon IOL in a subset of subjects (n=141, 6 sites) that participated in an investigational device exemption trial for the Clareon IOL. The Clareon model (SY60CL) used in this subset was a non-toric IOL with toric axis markings to measure IOL rotation. All subjects (adults aged ≥ 22 years who required cataract extraction by phacoemulsification) received the Clareon IOL unilaterally. The position of the toric markings was captured using dilated retro-illumination slit-lamp photography and ocular anatomical landmarks. Post-operative rotational stability was assessed by an independent reading center. IOL rotation was defined as the difference between IOL axis of orientation on the day of surgery (≤ 1 hour after surgery) and each post-operative visit. Post-operative IOL-based rotational stability was evaluated at day 0 (day of surgery), day 1, week 1, month 1, and month 6 post-operatively. Results: Compared with day 0, mean absolute IOL rotation was 1.85° on day 1 (n=127) and 2.27° at month 6 (n=124). Absolute IOL rotation ≤ 5° was observed in 95.3% of subjects on day 1 and 92.7% of subjects at month 6, compared with day 0. Between consecutive months 1 and 6 visits, mean absolute rotation was < 1°; 100% of subjects had < 10° rotation and 98.4% had ≤ 5°. The range of rotation on day 1 was 0° to 40.0° because of a subject with ocular trauma; when the trauma-outlier was removed, the mean absolute IOL rotation was 1.6° on day 1 (n=126) and 2.0° at month 6 (n=123). Conclusion: These results support the high rotational stability of the Clareon monofocal IOL and serve as reference of the rotational stability of Clareon toric IOLs.
- Open Access
- 1 April 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 1647-1657
Effectiveness and Safety of the Clareon Monofocal Intraocular Lens: Outcomes from a 12-Month Single-Arm Clinical Study in a Large Sample
Purpose: This study assessed effectiveness and safety of the novel Clareon intraocular lens (IOL; model SY60CL; Alcon Vision LLC). Patients and Methods: This was a prospective, single-arm, unmasked clinical trial at 16 investigative clinical sites in the United States. Included were adults ≥ 22 years who required cataract extraction by phacoemulsification. Following phacoemulsification, 350 subjects received SY60CL IOL unilaterally; 342 completed the study. Monocular best corrected distance visual acuity (CDVA) and uncorrected distance visual acuity (UDVA) were evaluated. The primary effectiveness endpoint was the percentage of subjects with CDVA ≤ 0.3 logMAR at month 12. Safety was assessed by monitoring adverse events (AEs). Visual acuity and safety outcomes were compared with historical safety and performance endpoint (SPE) rates. Results: At 12 months post-implantation, 99.7% of subjects receiving the SY60CL IOL achieved monocular CDVA ≤ 0.3 logMAR (primary effectiveness endpoint; 1-sided 95% upper confidence limit >SPE rate); 99.7% and 86.8% of subjects achieved monocular CDVA of ≤ 0.34 (20/40 Snellen or better) and ≤ 0.04 logMAR (20/20 Snellen or better), respectively. At 12 months, > 95% of subjects achieved mean monocular UDVA ≤ 0.3 logMAR; 97.1% and 57.6% of subjects achieved monocular CDVA of ≤ 0.34 and ≤ 0.04 logMAR, respectively. Mean monocular CDVA and UDVA were − 0.05 and 0.04 logMAR, respectively. AEs were within SPE limits. The most common nonserious ocular AE was posterior capsule opacification (5.4%). Serious AEs were < 1%, and no serious ocular AEs were assessed as related to the device. There were no observations for IOL glistenings at 12 months. Conclusion: Results of this study supported effectiveness and safety of the SY60CL IOL. Visual acuity outcomes with the SY60CL IOL exceeded the SPE rates for monocular CDVA and AEs were within the limit of historic SPE rates. (Model number SY60WF is the Clareon lens approved by the FDA.)
- 1 April 2021
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 15, 1647-1657
Open AccessEffectiveness and Safety of the Clareon Monofocal Intraocular Lens: Outcomes from a 12-Month Single-Arm Clinical Study in a Large Sample
Purpose: This study assessed effectiveness and safety of the novel Clareon intraocular lens (IOL; model SY60CL; Alcon Vision LLC). Patients and Methods: This was a prospective, single-arm, unmasked clinical trial at 16 investigative clinical sites in the United States. Included were adults ≥ 22 years who required cataract extraction by phacoemulsification. Following phacoemulsification, 350 subjects received SY60CL IOL unilaterally; 342 completed the study. Monocular best corrected distance visual acuity (CDVA) and uncorrected distance visual acuity (UDVA) were evaluated. The primary effectiveness endpoint was the percentage of subjects with CDVA ≤ 0.3 logMAR at month 12. Safety was assessed by monitoring adverse events (AEs). Visual acuity and safety outcomes were compared with historical safety and performance endpoint (SPE) rates. Results: At 12 months post-implantation, 99.7% of subjects receiving the SY60CL IOL achieved monocular CDVA ≤ 0.3 logMAR (primary effectiveness endpoint; 1-sided 95% upper confidence limit >SPE rate); 99.7% and 86.8% of subjects achieved monocular CDVA of ≤ 0.34 (20/40 Snellen or better) and ≤ 0.04 logMAR (20/20 Snellen or better), respectively. At 12 months, > 95% of subjects achieved mean monocular UDVA ≤ 0.3 logMAR; 97.1% and 57.6% of subjects achieved monocular CDVA of ≤ 0.34 and ≤ 0.04 logMAR, respectively. Mean monocular CDVA and UDVA were − 0.05 and 0.04 logMAR, respectively. AEs were within SPE limits. The most common nonserious ocular AE was posterior capsule opacification (5.4%). Serious AEs were < 1%, and no serious ocular AEs were assessed as related to the device. There were no observations for IOL glistenings at 12 months. Conclusion: Results of this study supported effectiveness and safety of the SY60CL IOL. Visual acuity outcomes with the SY60CL IOL exceeded the SPE rates for monocular CDVA and AEs were within the limit of historic SPE rates. (Model number SY60WF is the Clareon lens approved by the FDA.)
- Open Access
- 1 September 2019
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 2 (5) , 280-289
Once-Daily Netarsudil/Latanoprost Fixed-Dose Combination for Elevated Intraocular Pressure in the Randomized Phase 3 MERCURY-2 Study
- 1 September 2019
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 2 (5) , 280-289
Open AccessOnce-Daily Netarsudil/Latanoprost Fixed-Dose Combination for Elevated Intraocular Pressure in the Randomized Phase 3 MERCURY-2 Study
- Top Cited Papers
- 1 January 2019
- Published by Elsevier in Ophthalmology
- Vol. 126 (1) , 29-37
A Schlemm Canal Microstent for Intraocular Pressure Reduction in Primary Open-Angle Glaucoma and Cataract
- 1 January 2019
- Published by Elsevier in Ophthalmology
- Vol. 126 (1) , 29-37
Top Cited PapersA Schlemm Canal Microstent for Intraocular Pressure Reduction in Primary Open-Angle Glaucoma and Cataract
- Open Access
- 1 September 2018
- Published by Elsevier in American Journal of Ophthalmology Case Reports
- Vol. 11, 28-31
Tectonic corneal lamellar grafting for surgically-induced necrotizing scleritis after strabismus surgery: Case report & literature review
- 1 September 2018
- Published by Elsevier in American Journal of Ophthalmology Case Reports
- Vol. 11, 28-31
Open AccessTectonic corneal lamellar grafting for surgically-induced necrotizing scleritis after strabismus surgery: Case report & literature review
- 1 August 2018
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 192, 113-123
A Randomized, Controlled Phase I/II Study to Evaluate the Safety and Efficacy of MGV354 for Ocular Hypertension or Glaucoma
- 1 August 2018
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 192, 113-123
A Randomized, Controlled Phase I/II Study to Evaluate the Safety and Efficacy of MGV354 for Ocular Hypertension or Glaucoma
- Open Access
- 1 March 2017
- Published by Taylor & Francis in Patient Preference and Adherence
- Vol. ume 11, 487-494
Evaluating the patient experience after implantation of a 0.4 mg sustained release dexamethasone intracanalicular insert (DextenzaTM): results of a qualitative survey
Purpose: The purpose of this study is to evaluate the patient experience of sustained release dexamethasone intracanalicular insert (Dextenza™) following cataract surgery as part of a Phase III clinical trial program. Methods: This cross-sectional, qualitative evaluation involved individual interviews lasting approximately 45 minutes. Patients from four US investigational study sites who had previously received an insert were enrolled. There were no predesignated end points; this was a qualitative survey seeking a deeper understanding of patient experience. Results: Twenty-five patients were interviewed. Most patients (92%) reported the highest level of satisfaction grade with regard to overall product satisfaction. All patients described the insert as comfortable. Most patients (96%) described their overall experience with the insert as very convenient or extremely convenient. Twenty-two of 23 (96%) participants rated their experience with the insert as “very” or “extremely convenient”, compared to previous topical therapy, and 88% of patients stated that if they were to undergo cataract surgery again, they would request the insert. When asked if they would recommend the insert to family members or friends, 92% stated they would. The survey found that 84% of participants would be willing to pay more for the insert than for eye drop therapy. Conclusion: The dexamethasone insert was found by patients to be highly favorable with regard to overall satisfaction, convenience, and comfort. The insert was well received and largely preferred over topical therapy alternatives following surgery. More extensive evaluation of the patient experience is warranted, and future studies should help inform design of the next generation of sustained release drug delivery systems.
- 1 March 2017
- Published by Taylor & Francis in Patient Preference and Adherence
- Vol. ume 11, 487-494
Open AccessEvaluating the patient experience after implantation of a 0.4 mg sustained release dexamethasone intracanalicular insert (DextenzaTM): results of a qualitative survey
Purpose: The purpose of this study is to evaluate the patient experience of sustained release dexamethasone intracanalicular insert (Dextenza™) following cataract surgery as part of a Phase III clinical trial program. Methods: This cross-sectional, qualitative evaluation involved individual interviews lasting approximately 45 minutes. Patients from four US investigational study sites who had previously received an insert were enrolled. There were no predesignated end points; this was a qualitative survey seeking a deeper understanding of patient experience. Results: Twenty-five patients were interviewed. Most patients (92%) reported the highest level of satisfaction grade with regard to overall product satisfaction. All patients described the insert as comfortable. Most patients (96%) described their overall experience with the insert as very convenient or extremely convenient. Twenty-two of 23 (96%) participants rated their experience with the insert as “very” or “extremely convenient”, compared to previous topical therapy, and 88% of patients stated that if they were to undergo cataract surgery again, they would request the insert. When asked if they would recommend the insert to family members or friends, 92% stated they would. The survey found that 84% of participants would be willing to pay more for the insert than for eye drop therapy. Conclusion: The dexamethasone insert was found by patients to be highly favorable with regard to overall satisfaction, convenience, and comfort. The insert was well received and largely preferred over topical therapy alternatives following surgery. More extensive evaluation of the patient experience is warranted, and future studies should help inform design of the next generation of sustained release drug delivery systems.