Types
Company, Funder
Locations
Eden Prairie, United States

Latest Publications

  • Open Access

    A Pilot Study of the Feasibility of In-Ear EEG for Long-Term Temporal Lobe Brain Wave Monitoring

    by Andy Ho Wing Chan, Ryan C. Emadi, Andy Lin, Mark J. Schroeder, Ravinderjit Singh, Riaz Shaik, Mary-Catherine George, Jack Gomberg, Onome Eka, Toni Kavanagh, et al.

    Background: Traditional scalp electroencephalography (EEG), though clinically validated, presents significant limitations, including lengthy setup, patient discomfort, and limited mobility. These factors hinder its utility for long-term ambulatory monitoring. In-ear EEG offers a promising alternative by leveraging the ear canal’s anatomical proximity to the temporal lobes and natural mechanical stability. To address this, we developed SeizEAR, a standardized, three-size in-ear EEG system using paste-based electrodes with cross-ear referencing. Methods: This pilot study evaluated SeizEAR devices featuring small, medium, and large earpieces with superior and inferior paste-based electrodes in each ear, configured in a cross-ear reference scheme. It included five healthy adults who underwent recording sessions of approximately three hours (2.4 to 3.3 h). Electrode impedance was monitored against the acquisition system’s threshold indicator, with simultaneous scalp EEG from T7/T8 electrodes serving as the reference. Participants rated comfort on a 0–5 Likert scale every 30 min. Results: In-ear recordings showed moderate, band-dependent correspondence with ipsilateral temporal scalp electrodes, strongest in the delta and alpha bands and weakest in beta, and correspondence was consistently higher against a geometrically matched T7–T8 bipolar derivation than against a single referenced electrode. In-ear alpha reactivity to eye closure was present but attenuated relative to scalp. Comfort ratings remained high over the final two hours of wear, with no reported adverse events. Conclusions: SeizEAR acquired in-ear EEG that corresponded moderately with temporal scalp EEG and was well-tolerated over multi-hour wear in healthy adults. These preliminary findings support further development of a standardized in-ear EEG system and require confirmation in an adequately powered sample.

  • Open Access

    An Intelligent Directionality System for Hearing Aids Incorporating Deep Neural Networks: Improving Speech Understanding While Preserving Spatial Awareness

    by Daniel Marquardt, Jinjun Xiao, Al Ganeshkumar, Jingjing Xu, Larissa Taylor, Martin McKinney, David A. Fabry, Achintya K. Bhowmik

    Background: Directionality algorithms are fundamental to modern hearing aids, enhancing speech perception in noisy environments by improving the signal-to-noise ratio. Conventional adaptive approaches rely on heuristic optimization criteria and often improve speech understanding from specific directions, typically the front, at the expense of spatial awareness. A deep neural network (DNN)-based directionality system was developed that dynamically optimizes spatial filtering through a data-driven framework capable of representing complex acoustic scenes. The system intelligently enhances target speech while preserving awareness of environmental sounds. Methods: The proposed DNN-based directionality system was evaluated against conventional directionality algorithms by assessing word recognition performance, perceived speech clarity, and listener preference across diverse acoustic scenarios. To complement subjective measures, an artificial intelligence (AI)-based objective intelligibility metric was additionally developed using automated speech-to-text analysis, enabling scalable and consistent benchmarking across devices. Results: Results across the behavioral and objective assessments indicate improved speech intelligibility outcomes together with maintained access to environmental sounds. Mean SRT50 improved by 1.4 dB relative to legacy directionality for target speech presented at 90° and by 4.7 dB relative to an omnidirectional pattern when frontal target speech was accompanied by a rear interfering talker. Spatial adaptation further improved environmental sound audibility in three out of four conditions and significantly improved the detection threshold for speech presented at 135° by 2.42 dB. Conclusions: These results show that the system can preserve speech originating away from the front while using acoustic context and spatial filtering to attenuate competing speech that interferes with a frontal conversation.

  • Open Access

    Effectiveness of deep neural networks in hearing aids for improving signal-to-noise ratio, speech recognition, and listener preference in background noise

    by Matthew B. Fitzgerald, Varsha Mysore Athreya, Majd Srour, Jwala P. Rejimon, Soumya Venkitakrishnan, Achintya K. Bhowmik, Robert K. Jackler, Kristen K. Steenerson, David A. Fabry

    Introduction: Traditional approaches to improving speech perception in noise (SPIN) for hearing-aid users have centered on directional microphones and remote wireless technologies. Recent advances in artificial intelligence and machine learning offer new opportunities for enhancing the signal-to-noise ratio (SNR) through adaptive signal processing. In this study, we evaluated the efficacy of a novel deep neural network (DNN)-based algorithm, commercially implemented as Edge Mode™, in improving SPIN outcomes for individuals with sensorineural hearing loss beyond that of conventional environmental classification approaches.Methods: The algorithm was evaluated using (1) objective KEMAR-based performance in seven real-world scenarios, (2) aided and unaided speech-in-noise performance in 20 individuals with SNHL, and (3) real-world subjective ratings via ecological momentary assessment (EMA) in 20 individuals with SNHL.Results: Significant improvements in SPIN performance were observed on CNC+5, QuickSIN, and WIN, but not NST+5, likely due to the use of speech-shaped noise in the latter, suggesting the algorithm is optimized for multi-talker babble environments. SPIN gains were not predicted by unaided performance or degree of hearing loss, indicating individual variability in benefit, potentially due to differences in peripheral encoding or cognitive function. Furthermore, subjective EMA responses mirrored these improvements, supporting real-world utility.Discussion: These findings demonstrate that DNN-based signal processing can meaningfully enhance speech understanding in complex listening environments, underscoring the potential of AI-powered features in modern hearing aids and highlighting the need for more personalized fitting strategies.


  • Uniting Integration: Advancing RF Interconnect Technologies

    by Yali Zhang, Aditya Dave, Nikita Majabeen, Rashaunda Henderson, Bethanie Stadler, Rhonda R. Franklin

    Recently, advancing RF interconnect technologies for future 2.5D and 3D integration have been identified as an important game changer for energy efficient complex integrated circuit systems. Researchers are improving the performance of traditional interconnect technologies, such as wire bonds, and are exploring novel technologies as alternative interconnect solutions, such as stich chip and copper nanowire vias. Due to the high speed needs of 5G and 6G communication, interconnect operation needs to extend into the millimeter and sub-millimeter wave frequency range, which poses big challenges for designs with low loss and broad bandwidth. Herein, this review discusses and describes recent advances in interconnect technologies for wired and wireless RF applications. The research work is promising and shows a variety of methods to achieve low loss over a broad range of frequencies needed to truly enable design of energy efficient complex integrated circuit systems.


  • Use of Hearing Aids Embedded with Inertial Sensors and Artificial Intelligence to Identify Patients at Risk for Falling

    by Kristen K. Steenerson, Bryn Griswold, Donald P. Iii Keating, Majd Srour, Justin R. Burwinkel, Erin Isanhart, Yifei Ma, David A. Fabry, Achintya K. Bhowmik, Robert K. Jackler, et al.

    Objective: To compare fall risk scores of hearing aids embedded with inertial measurement units (IMU-HAs) and powered by artificial intelligence (AI) algorithms with scores by trained observers. Study Design: Prospective, double-blinded, observational study of fall risk scores between trained observers and those of IMU-HAs. Setting: Tertiary referral center. Patients: Two hundred fifty participants aged 55–100 years who were at risk for falls. Interventions: Fall risk was categorized using the Stopping Elderly Accidents, Deaths, and Injuries (STEADI) test battery consisting of the 4-Stage Balance, Timed Up and Go (TUG), and 30-Second Chair Stand tests. Performance was scored using bilateral IMU-HAs and compared to scores by clinicians blinded to the hearing aid measures. Main Outcome Measures: Fall risk categorizations based on 4-Stage Balance, Timed Up and Go (TUG), and 30-Second Chair Stand tests obtained from IMU-HAs and clinicians. Results: Interrater reliability was excellent across all clinicians. The 4-Stage Balance and TUG showed no statistically significant differences between clinician and HAs. However, the IMU-HAs failed to record a response in 12% of TUG trials. For the 30-Second Chair Stand test, there was a significant difference of nearly one stand count, which would have altered fall risk classification in 21% of participants. Conclusions: These results suggest that fall risk as determined by the STEADI tests was in most instances similar for IMU-HAs and trained observers; however, differences were observed in certain situations, suggesting improvements are needed in the algorithm to maximize accurate fall risk categorization.


  • Open Access

    Toward Alleviating the Stigma of Hearing Aids: A Review

    by Edward Madara, Achintya K. Bhowmik

    Despite the significant advancements in hearing aid technology, their adoption rates remain low, with stigma continuing to be a major barrier for many. This review aims to assess the origins and current state of hearing aid stigma, as well as explore potential strategies for alleviating it. This review examines the societal perceptions, psychological impacts, and recent technological advancements that can influence hearing aid adoption and reduce stigma. Methods: A narrative-focused review of the literature from peer-reviewed journals and reputable sources was conducted, analyzing papers on hearing aid stigma, adoption rates, and technological solutions. The research works were categorized based on their focus on the drivers and alleviation strategies for the stigma of hearing aids. Results: This review identifies stigma as a complex, multifaceted issue driven primarily by ageism, disability perception, and the association of hearing aids with aging and incapability. Despite technological improvements, the studies surveyed listed stigma as a major factor in non-adoption. Technological advancements such as artificial intelligence in sound processing, multifunctional features, and innovative design have shown potential in reducing stigma and improving user experience. Conclusions: Alleviating the stigma of hearing aids requires a multi-pronged approach, combining improvements in technology with changes in societal perceptions. Multifunctional devices including both health and communications functions, advanced signal processing, and esthetic improvements can drive their adoption, but broader public health awareness and education are also essential to changing societal attitudes and fostering greater acceptance of hearing aids.


  • Top Cited Papers

    Virtual and augmented reality: Human sensory‐perceptual requirements and trends for immersive spatial computing experiences

    by Achintya K. Bhowmik

    Building on several decades of research and development, the recent progress in virtual reality (VR) and augmented reality (AR) devices with spatial computing technologies marks a significant leap in human–computer interaction, with applications ranging from entertainment and education to e‐commerce and healthcare. Advances in these technologies promise immersive experiences by simulating and augmenting the real world with computer‐generated digital content. The core objective of the VR and AR systems is to create convincing human sensory perceptions, thereby creating immersive and interactive experiences that bridge the gap between virtual and physical realities. However, achieving true immersion remains a goal, and it necessitates a comprehensive understanding of the neuroscience of human multisensory perception and accurate technical implementations to create a consistency between natural and synthetic sensory cues. This paper reviews the human sensory‐perceptual requirements vital for achieving such immersion, examines the current status and challenges, and discusses potential future advancements.


  • COVID-19 Hospitalization Trends in Rural Versus Urban Areas in the United States

    by Yi Zhu, Caitlin Carroll, Khoa Vu, Soumya Sen, Archelle Georgiou, Pinar Karaca-Mandic

    Since the summer of 2020, the rate of coronavirus cases in the United States has been higher in rural areas than in urban areas, raising concerns that patients with coronavirus disease 2019 (COVID-19) will overwhelm under-resourced rural hospitals. Using data from the University of Minnesota COVID-19 Hospitalization Tracking Project and the U.S. Department of Health and Human Services, we document disparities in COVID-19 hospitalization rates between rural and urban areas. We show that rural-urban differences in COVID-19 admission rates were minimal in the summer of 2020 but began to diverge in fall 2020. Rural areas had statistically higher hospitalization rates from September 2020 through early 2021, after which rural-urban admission rates re-converged. The insights in this article are relevant to policymakers as they consider the adequacy of hospital resources across rural and urban areas during the COVID-19 pandemic.


  • Open Access

    Association of Large Financial Incentives With COVID-19 Vaccination Uptake Among Employees of a Large Private Company

    by Archelle Georgiou, Jessica Chang, Pinar Karaca-Mandic

    Without a federal mandate,1 motivating employees to receive COVID-19 vaccination is a challenge. For influenza vaccination, Nowalk et al2 found that a small ($5) financial incentive increased uptake by 3.4 percentage points in a workplace-based program. However, financial incentives to increase COVID-19 vaccination uptake have mixed outcomes. Campos-Mercade et al3 found that a moderate ($24) cash incentive increased COVID-19 vaccine uptake by 4.2 percentage points, whereas Wong et al4 found that $25 was associated with slower decline of vaccination uptake. Acharya and Dhakal5 found that large but uncertain incentives (lottery programs) across 11 states had mixed success.


  • Open Access

    Individualized Hear-through For Acoustic Transparency Using PCA-Based Sound Pressure Estimation At The Eardrum

    by Wenyu Jin, Tim Schoof, Henning Schepker

    The hear-through functionality on hearing devices, which allows hearing equivalent to the open-ear while providing the possibility to modify the sound pressure at the eardrum in a desired manner, has drawn great attention from researchers in recent years. To this end, the output of the device is processed by means of an equalization filter, such that the transfer function between external sound sources and the eardrum is equivalent for the open-ear and the aided condition with the device in the ear. To achieve an ideal performance, the equalization filter design assumes the exact knowledge of all the relevant acoustic transfer functions. A particular challenge is the transfer function between the hearing device receiver and the eardrum, which is difficult to obtain in practice as it requires additional probe-tube measurements. In this work, we address this issue by proposing an individualized hear-through equalization filter design that leverages the measurement of the so-called secondary path to predict the sound pressure at the eardrum. Experimental results using real-ear measured transfer functions confirm that the proposed method achieves a good sound quality compared to the open-ear while outperforming filter designs that do not leverage the proposed estimator.